Satel ART-200 is a wireless radiator thermostat that allows you to control the room temperature in a more energy-efficient way. With the ART-200, you can set and adjust the temperature remotely using the ABAX 2 two-way wireless system. It features three operating modes, a boost heat function for fast heating, anti-scale and open window detection, anti-freeze protection, child lock, and thermostat status overview. You can also choose between an internal or external temperature sensor.

Satel ART-200 is a wireless radiator thermostat that allows you to control the room temperature in a more energy-efficient way. With the ART-200, you can set and adjust the temperature remotely using the ABAX 2 two-way wireless system. It features three operating modes, a boost heat function for fast heating, anti-scale and open window detection, anti-freeze protection, child lock, and thermostat status overview. You can also choose between an internal or external temperature sensor.

Wireless radiator thermostat
ART-200
Firmware version 1.00
art-200_en 12/22
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.pl
EN
IMPORTANT
The device should be installed by qualified personnel.
Prior to installation, please read carefully this manual.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
The rating plate of the device is located on the enclosure base.
The device meets the requirements of the applicable EU directives.
The device is designed for indoor installation.
The device must not be disposed of with other municipal waste. It should be disposed
of in accordance with the existing rules for environment protection (the device was
placed on the market after 13 August 2005).
The device meets the technical regulations of the Eurasian Customs Union.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us:
https://support.satel.pl
Hereby, SATEL sp. z o.o. declares that the radio equipment type ART-200 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.satel.pl/ce
The following symbols may be used in this manual:
- note,
- caution.
CONTENTS
1 Features .............................................................................................................................. 2
2 Description ........................................................................................................................... 2
LCD display ................................................................................................................... 3
Keys .............................................................................................................................. 4
Radio communication .................................................................................................... 5
Energy saving mode (ECO) .......................................................................................... 5
Battery status control ..................................................................................................... 5
Operating modes ........................................................................................................... 5
Thermostat calibration ................................................................................................... 5
Thermostat adaptation .................................................................................................. 5
Fast heating function (Boost Heat) ................................................................................ 6
Anti-scale protection ...................................................................................................... 6
Open window detection ................................................................................................. 6
Anti-freeze protection .................................................................................................... 6
Temperature measurement correction .......................................................................... 6
Child lock ....................................................................................................................... 6
3 Installation ........................................................................................................................... 6
3.1 Installation on M30x1.5 mm valve ................................................................................. 8
3.2 Installation on Danfoss RA valve ................................................................................... 8
4 Configuring the thermostat ................................................................................................ 10
4.1 Remote configuration .................................................................................................. 10
4.2 Configuration using the keys ....................................................................................... 10
Enter the operating mode menu .................................................................................. 10
Change the operating mode ........................................................................................ 10
Edit the operating mode settings ................................................................................. 10
Exit the operating mode menu .................................................................................... 11
Enter the advanced settings menu .............................................................................. 11
Edit the advanced settings .......................................................................................... 11
Exit the advanced settings menu................................................................................. 12
5 Start the Boost Heat function ............................................................................................. 12
6 Thermostat status overview ............................................................................................... 12
7 Disabling the keys ............................................................................................................. 13
8 Specifications .................................................................................................................... 13
2 ART-200 SATEL
The ART-200 radiator thermostat is used to control the room temperature in a more
energy-efficient way. The thermostat allows you to control the radiator valve remotely and
manually. It is designed to work within the ABAX 2 two-way wireless system. It is supported
by:
ACU-220 / ACU-280 controller with firmware version 6.06 (or newer),
ARU-200 repeater.
The thermostat is not supported by the ACU-220 / ACU-280 controller connected to
a VERSA series control panel.
The thermostat motor makes sounds when the thermostat is controlling the radiator
valve.
1 Features
Installation on valves with the M30x1.5mm threaded connection.
Temperature adjustment in the range from 5°C to 30°C.
3 operating modes.
Remote setting of the “Comfort temperature” or “Economy temperature” mode.
Remote temperature setting for the Comfort temperature” and Economy temperature”
modes.
Choice between two temperature sensor types:
internal,
external (ABAX 2 system’s temperature sensor).
Boost Heat function for fast heating.
Anti-scale function.
Open window detection.
Anti-freeze protection.
Child Lock.
Thermostat status overview.
LCD display for easier control and configuration.
Battery charge level indicator.
Encrypted two-way radio communication in the 868 MHz frequency band (AES standard).
Transmission channel diversity 4 channels for automatic selection of the one that will
enable transmission without interference with other signals in the 868 MHz frequency
band.
Device firmware updated remotely.
“ECO” option for longer battery life.
Battery status control.
Included elements:
adapter for mounting on a Danfoss RA valve,
reducer ring for easier installation on valves with smaller diameter.
2 Description
The ART-200 thermostat occupies one position on the list of wireless devices.
SATEL ART-200 3
union nut.
LCD display.
keys to control and configure the thermostat (see: “Configuring the thermostat”).
LCD display
The symbols and messages shown on the display will help you control and configure the
thermostat. When the thermostat is at work, the display shows temperature registered by the
sensor (Fig. 2). See Fig. 3 for all symbols that can be displayed. See Table 1. for all possible
messages.
Explanation of the symbols on Fig. 2 and 3:
Comfort temperature” operating mode.
Economy temperature” operating mode.
open window detection enabled.
operating mode configured and switched remotely or manually.
operating mode configured and switched manually.
temperature displayed in degrees Celsius.
temperature registered by the sensor is displayed.
temperature set for the selected operating mode is displayed.
valve position is displayed, where: 0% valve fully closed, 100% valve fully open.
low batteries (battery voltage lower than 2.3 V).
Message
Explanation
Action to be taken
Thermostat ready for calibration to
be started.
Press or to start the
calibration.
Thermostat keys are disabled.
Press + to enable the
keys (if the keys were disabled
remotely, they can only be enabled
remotely).
4 ART-200 SATEL
Message
Explanation
Thermostat adaptation in progress.
Anti-freeze protection is enabled
(temperature dropped below 5°C).
Trouble with changing the valve
position.
Incorrect operating range of the
thermostat (calibration failure).
Low battery valve control disabled
to protect against complete battery
discharge.
Table 1.
The events labelled as F01, F02 and F03 will be indicated in the ABAX 2 system as no
communication with the thermostat.
Keys
The keys are used to control and configure the thermostat.
Key
Function
short press enter the operating mode menu / change the operating mode
/ switch between items in the advanced settings menu / switch between
thermostat status information / exit the edit mode and save changes
2 short presses enter / exit the thermostat status overview
long press enter or exit the advanced settings menu / exit the edit mode
without saving changes / disable the Boost Heat function
enter the operating mode menu / edit the operating mode / value down
(short press in steps, press and hold stepless)
enter the operating mode menu / edit the operating mode / start the
function / value up (short press in steps, press and hold stepless)
+
start the Boost Heat function
+
enable / disable the keys
Table 2.
SATEL ART-200 5
Radio communication
The thermostat connects to the controller at regular time intervals to provide information
about its state (periodical communication). Additional communication takes place when the
ART-200 thermostat is sending to the controller the settings adjusted manually.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable the “ECO” option in the device. When
the “ECO” option is enabled, the periodical communication takes place every 3 minutes.
This will prolong the battery life.
Battery status control
When the battery voltage is below 2.3 V, information about low battery will be sent during
each transmission and the symbol will be flashing on the display. When the voltage drops
below 2.1 V, the thermostat will disable the valve control in order to protect the battery from
complete discharge. The message F03 will be displayed and the valve will be 25% open.
Operating modes
Comfort temperature thermostat is to maintain room temperature at a comfortable level.
This mode can be enabled remotely or manually.
Economy temperature thermostat is to maintain room temperature at an energy-efficient
level (e.g. when household members are at work or asleep at night). This mode can be
enabled remotely or manually.
Manual setting of the valve position / temperature radiator valve is set in a given
position / thermostat is to maintain the set temperature. This mode can be enabled
remotely or manually but the valve position / temperature can only be set manually.
The “Manual setting of the valve position / temperature” can be enabled remotely if the
controller is connected to a SATEL alarm control panel. If the operating mode has
been enabled remotely, the thermostat can only be controlled manually. Remote
control is possible only after the mode is disabled remotely.
Thermostat calibration
When calibrating, the thermostat adjusts its actuator stroke to the radiator valve stroke.
During calibration, the thermostat operating range is defined (the valve end positions, where:
0% = valve fully closed, 100% = valve fully open). The thermostat must be calibrated after it
is installed on the valve and each time after batteries are replaced. The CAL message will be
displayed when calibration is required.
Thermostat adaptation
After it is started, the thermostat will find the optimal valve position to reach and maintain the
set temperature in the room. When the valve is open insufficiently, the room takes too long to
heat up. When the valve is open too much, the room heats up fast but the temperature
continues to rise beyond the set value and the room is too hot. The adaptation is repeated
whenever the thermostat detects that the conditions in the room have changed in a way that
can affect its operation. When the adaptation is in progress, the ADPT message and the
temperature will be displayed alternately.
You can disable the adaptation function (see: Edit the advanced settingsp. 11). When this
function is disabled, the temperature will be regulated using the thermostat manufacturer
settings.
6 ART-200 SATEL
Boost Heat
If the room temperature is too low and uncomfortable, you can enable the Boost Heat
function to heat the room faster. The valve will then be fully open for a set time (by default: 15
minutes). The remaining time of the Boost Heat function will be displayed.
You can turn off the function yourself (see: “Keysp. 4). If you do, the preset operating mode
will be enabled.
The Boost Heat function has the highest priority. When it is enabled, other functions
and settings are ignored.
Anti-scale protection
Scale can build up inside the valve when it remains unused for a long time. To prevent it,
the thermostat will fully open the valve once every two weeks.
Open window detection
The thermostat can detect a sudden drop in temperature, e.g. caused by open window.
The radiator valve will then be closed for a set time (by default: 30 minutes) or until the
thermostat detects a rise in temperature. The symbol will be flashing when the valve is
closed as a result of open window detection.
You can restore the thermostat to the normal operating mode manually (see: “Edit the
advanced settings” p. 11).
Anti-freeze protection
When temperature drops below 5°C, the thermostat will open the valve to prevent the
radiator from freezing. The valve will remain open until the thermostat operating mode is
changed or temperature rises to 8°C. When the anti-freeze protection is activated, the A-FR
message will be displayed alternately with temperature registered by the sensor (labelled as
). When the protection is activated, this information is sent to the controller during
periodical communication.
Temperature measurement correction
The thermostat can correct the temperature information provided by the internal sensor.
The correction can be made in the range of ±3,5°C.
Child lock
You can disable the thermostat keys to prevent the settings from being accidentally changed
(e.g. by children at play). The keys can be disabled manually or remotely. You cannot enable
the keys manually if they have been disabled remotely. The LOC message will be displayed
for 20 seconds after disabling the keys and each time any key is pressed. If you enable the
keys, information about the currently selected operating mode will be displayed.
3 Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly. Do not
crush the battery, cut it or expose it to high temperatures (throw it into the fire,
put it in the oven, etc.).
Do not expose the battery to very low pressure due to the risk of battery
explosion or leakage of flammable liquid or gas.
SATEL ART-200 7
Be particularly careful during installation and replacement of the battery.
The manufacturer is not liable for the consequences of incorrect installation of
the battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
The device is designed for indoor installation. When in use, the ART-200 thermostat must be
located within the radio range of the ABAX 2 controller. Thick walls, metal partitions, etc. will
reduce the range of the radio signal. Use the ARF-200 tester to check the level of radio
signal. Place the tester close to the valve on which you want to install the thermostat. If the
radio signal level indicated by the tester is higher than 40%, you can install the thermostat
there.
The thermostat is fitted for radiator valves with the M30 x 1.5 mm threaded connection. It is
compatible with most radiator valves on the market. In order to install the thermostat on the
Danfoss RA valve, use the supplied adapter.
You do not need any special tools to install the thermostat. Disconnecting the heating
system is not required.
1. Use your fingers to press down the symbols on both sides of the battery cover (gray
element on Fig. 4). Pull to remove the cover.
2. Install two 1,5 V LR6 AA alkaline batteries (they are not supplied with the thermostat).
When the batteries are installed, the CAL message will be displayed. The actuator rod will
be completely withheld inside the thermostat cover so that it is possible to install the
thermostat on the valve.
3. Add the thermostat to the wireless system (see the ABAX 2 controller manual). For that,
you need the thermostat serial number. You will find it on a sticker inside the battery
cover.
4. Replace the battery cover.
5. Install the thermostat on the valve (see: “Installation on M30x1.5 mm valve” or Installation
on Danfoss RA valve”). If the actuator rod (labelled as on Fig. 7) is not completely
withheld inside the thermostat cover, remove the batteries before installation, insert them
back and wait until the rod hides inside the cover.
Before you remove the old thermostatic head, make sure to turn it several times from
minimum to maximum position and back. Unscrew the old thermostat when it is in the
maximum position. When the thermostat is removed, the valve pin should be fully
extended.
8 ART-200 SATEL
6. Press or . Calibration will begin. Information about the currently selected
operating mode of the thermostat will be displayed (by default: Comfort temperature”).
When calibration is in progress, you can configure the thermostat settings (see:
Configuring the thermostat”).
3.1 Installation on M30x1.5 mm valve
1. Place the thermostat on the valve (Fig. 5). Adjust the thermostat position so that the user
can easily access the keys and the LCD display.
2. Tighten the thermostat on the valve using the union nut (Fig. 6). Do it by hand.
3. If the thermostat is seated loosely on the valve, use the reducer ring. Unscrew the
thermostat, place the reducer ring inside its flange (Fig. 7), then repeat points 1 and 2.
3.2 Installation on Danfoss RA valve
1. Fasten the adapter on the valve.
1.1. Place the adapter on the valve (Fig. 8).
1.2. Bend open the adapter clamp with a screwdriver and press the adapter against the
valve flange (Fig. 9). The valve flange is labelled as on Fig. 9. Make sure the
bumps inside the adapter ( on Fig. 9) line up with the notches on the valve body
( on Fig. 9).
1.3. Fasten the adapter clamp with a screw (Fig. 10).
Be careful not to pinch your fingers with the adapter clamp.
SATEL ART-200 9
2. Place the thermostat on the valve (Fig. 11). Adjust the thermostat position so that the user
can easily access the keys and the LCD display.
3. Tighten the thermostat on the adapter using the union nut (Fig. 12). Do it by hand.
4. If the thermostat is seated loosely on the valve, use the reducer ring. Unscrew the
thermostat, place the reducer ring inside its flange (Fig. 7), then repeat points 2 and 3.
10 ART-200 SATEL
4 Configuring the thermostat
4.1 Remote configuration
To find out how to configure the thermostat, please refer to the ABAX 2 controller manual.
4.2 Configuration using the keys
Enter the operating mode menu
Press any key. Information about the current operating mode of the thermostat will be
displayed (see: Table 3). Depending on the operating mode, the information may include
temperature in degrees Celsius or valve position in percentage.
Change the operating mode
Each press of the key will change the operating mode to the next one. The operating
modes are arranged in sequence presented in Table 3. Keep pressing the key until you
select the desired operating mode.
Operating mode
Comfort temperature (T2)
Economy temperature (T1)
Manual setting of the valve position / temperature
Table 3.
Edit the operating mode settings
1. Enter the operating mode menu.
2. Use the key to select the operating mode whose settings you want to edit.
SATEL ART-200 11
3. Press or to start editing. The displayed value (temperature / valve position)
will start flashing.
4. Use or to set the temperature / valve position. When editing the “Manual
setting of the valve position / temperature” mode, if you want to set the temperature, keep
pressing the key until the valve position (percentage) switches to temperature (degrees).
5. Press to save the changes made (to quit, press and hold ).
Exit the operating mode menu
Wait about 20 seconds. The thermostat will exit the operating mode menu. The temperature
registered by the sensor will be displayed (labelled as ).
Any changes made in the settings will only be saved after the thermostat exits the
operating mode menu. If you remove the batteries before 20 seconds pass since your
last activity in the operating mode menu, the changes will not be saved.
Enter the advanced settings menu
1. Press any key to enter the operating mode menu.
2. Press and hold . The first available function will be displayed.
Edit the advanced settings
1. Enter the advanced settings menu.
2. Use the key to select the function you want to start. The functions are arranged in
sequence presented in Table 4.
3. Press to start the function. The current setting will be displayed.
4. Use and to change the settings.
5. Press to save the changes made (to quit, press and hold ). You will return to
the list of functions.
Function
Description
ESC AER
Restoring normal thermostat operation after open window
detection
This function is available when the valve is closed as a result of open
window detection.
Start the function and press to restore the thermostat to the
normal operating mode or press to exit the function.
BOOST
Duration of the Boost Heat function
You can program from 1 to 240 minutes.
By default: 15 minutes.
12 ART-200 SATEL
AER
Valve closing time after open window detection
You can program from 0 to 60 minutes (0 open window detection
disabled).
By default: 30.
PI ADAPT
Thermostat adaptation
You can select ON (function enabled) or OFF (function disabled).
By default: ON.
FACT RES
Restoring default settings
Start the function and press to restore default settings or press
to quit.
Table 4.
Exit the advanced settings menu
Press and hold . Information about the currently selected operating mode will be
displayed.
If you take no action for 20 seconds, the thermostat will exit the menu automatically.
Temperature registered by the sensor will be displayed (labelled as ).
5 Starting the Boost Heat function
Press and simultaneously. Information about the remaining time of the function
will be displayed (e.g. B030 30 minutes). When the time runs out, the selected operating
mode will be resumed.
If you press and simultaneously when the function is running, the countdown will
be restarted.
If you want to turn off the function, press and hold .
6 Thermostat status overview
1. Enter the operating mode menu. Information about the currently selected operating mode
will be displayed.
2. Press 2 times. Information about temperature registered by the sensor will be
displayed.
3. Press to go to the next item. The items are displayed in sequence presented in
Table 5 (temperature is next after thermostat serial number).
SATEL ART-200 13
Available thermostat status information
Temperature registered by the sensor (Pv).
Current valve position, where: 0% valve fully closed, 100% valve fully open.
Current battery voltage (accuracy up to 0.01 V).
Current adaptation status:
ADAPT PREP adaptation was never started,
ADAPT IP adaptation in progress,
ADAPT END adaptation concluded,
ADAPT OFF adaptation disabled (temperature will be regulated using the thermostat
manufacturer settings).
Thermostat serial number.
Table 5.
4. Press 2 times to exit the overview. Information about the currently selected
operating mode will be displayed.
If you take no action for 20 seconds, the thermostat will exit the function automatically.
Temperature registered by the sensor will be displayed (labelled as ).
7 Disabling the keys
Press the and keys simultaneously to disable / enable the keys.
8 Specifications
Operating frequency band ................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) .......................................................... up to 1000 m
Batteries ......................................................................................................... 2 x 1.5 V LR6 AA
Battery life expectancy .......................................................................................... up to 2 years
Temperature measurement range ....................................................................... -10°C...+50°C
Temperature measurement accuracy ............................................................................. ±0.1°C
Temperature adjustment range ................................................................................. 5°C...30°C
Temperature adjustment accuracy ................................................................................. ±0,5°C
Standby current consumption ........................................................................................... 98 µA
Maximum current consumption ........................................................................................ 80 mA
Operating temperature range ............................................................................... -10°C...+55°C
Maximum humidity .......................................................................................................... 93
±
3%
Enclosure dimensions .................................................................................... 55 x 102 x 61 mm
Weight ............................................................................................................................... 136 g
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Satel ART-200 Installation guide

Category
Thermostats
Type
Installation guide

Satel ART-200 is a wireless radiator thermostat that allows you to control the room temperature in a more energy-efficient way. With the ART-200, you can set and adjust the temperature remotely using the ABAX 2 two-way wireless system. It features three operating modes, a boost heat function for fast heating, anti-scale and open window detection, anti-freeze protection, child lock, and thermostat status overview. You can also choose between an internal or external temperature sensor.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI