125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
Product Manual:
WP-08 Series
Axial Ventilator
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04 Page 3
Table of Contents
Section Description Page #
1.0...................................... Safety..........................................................4
1.1........................... Safety Alert Symbol
1.2........................... General Safety Information
2.0...................................... Introduction & Product Information........ 6
2.1 ...........................Axial Ventilator Speci cations & Applications
3.0......................................Con guration & Assembly........................ 7
3.1...........................Parts Diagram & List
3.2...........................Wiring Diagram
4.0...................................... Product Operation..................................... 9
4.1 ...........................Product Description & Capabilities
4.2 ...........................Product Set-Up & Operation
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
Page 4
The following section will address the safety precautions which must be adhered to when working with confined Space
Ventilation equipment such as the WP-08 Series Axial Ventilator. Any user must familiarize themselves
with the information in this section before utilizing the equipment.
SIGNAL WORDS:
Note the use of the signal words DANGER, WARNING and CAUTION with the safety messages. The appropriate signal
word for each message has been selected using the following guidelines:
DANGER- Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. This
signal word is to be limited to the most extreme situations or for hidden or unseen hazards.
WARNING- Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury and
includes obvious and hidden hazards. It may also be used to alert against unsafe practices.
CAUTION- Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It
may also be used to alert against unsafe practices.
You are responsible for the safe operation of your WP-08 Series Axial Ventilator. You must ensure that anyone who
will operate or work around the equipment be familiar with confined space ventilation procedures. This manual will take
you step-by-step through the workings and capabilities of the WP-08 Series Axial Ventilator and alert you to all good
safety and operating practices while using the system.
Remember, you are the key to safety. Good safety practices not only protect you but also the people around you. Make
these practices a working part of your safety program. Be certain that everyone operating in or around a con ned space
is familiar with the procedures recommended and follows safety precautions. Remember, most accidents can be pre-
vented. Do not risk injury or death by ignoring good safety practices.
The most important safety device on this equipment is a safe operator. It is the operator’s responsibility to read
and understand all safety and operating instructions in the manual and to follow them. Most accidents can be
avoided.
A person must understand the operation of this equipment and be trained in it’s usage before operating the
equipment. An untrained operator exposes himself and others to possible serious injury or death.
Do not modify the equipment in any way. Unauthorized modi cation may impair the function and/or safety and
could affect the life of the equipment.
Think SAFETY! Work SAFELY!
1.0 - Safety
1.1 - Safety Alert Symbol
SAFETY ALERT SYMBOL
This Safety Alert symbol means ATTENTION! BECOME ALERT! YOUR SAFETY
IS INVOLVED!
The Safety Alert symbol identi es important safety messages on your Conned
Space Product and in the manual. When you see this symbol, be alert to the
possibility of personal injury or death. Follow the instruction in the safety message.
Why is this symbol important to you?
3 BIG Reasons: Accidents Disable and Kill.
Accidents Cost You Money.
Accidents Can Be Avoided.
!
READ AND SAVE THESE INSTRUCTIONS
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04 Page 5
1.2 - General Safety Information
!! WARNING ! - To reduce the risk of re or electric shock, DO NOT use this fan with any solid-
state speed control device.
! WARNING ! - DO NOT use this fan to exhaust ammable vapors.
! CAUTION ! - Be sure that the ventilator is disconnected from the power source before per-
forming any maintenance or repair work on the ventilator.
! CAUTION ! - Check all power cords for cuts, frayed ends, or brittle insulation. Refer to the
parts list for replacement cord part number.
! CAUTION ! - The user must ensure that the ventilator is located where it cannot fall into water
inadvertently and that the cord or plug connections are not routed through water.
Safety Precautions:
It is necessary to follow these safety precautions, each time, prior to using the product.
The Safety Precautions are not limited to, but must include the following items;
Do not use the ventilator for anything other than its intended use.1.
Do not wear loose clothing that can become entangled in operating machinery. Do not operate the ventilator2. without inlet or outlet screen guards in place.
Do not place ngers or any other object through inlet or outlet screens.3.
Always operate the ventilator from a properly grounded GFCI-protected receptacle.4.
Never handle energized power cords with wet hands.5.
Never let cord or plug connections lay in water. Locate the ventilator so that it cannot fall into water inadvertently.6.
Never use cords with frayed , cut, or brittle insulation. Check the cord for sound connections to the ground fault7. interrupter receptacle.
Never use the WP-08 Series ventilator in an explosive environment.8.
Ensure that toxic fumes are not blown into the con ned space.9.
Unattended use of equipment is not recommended.10.
Press the TEST button (then RESET button) every month to assure that the ground-fault circuit-interrupter is in11. proper operation.
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
Page 6
2.1 - Axial Ventilator Speci cations & Applications
2.0 - Introduction & Product Information
Congratulations on your choice of a WP-08 Series Axial Ventilator to compliment your con ned space ventilation
operation. This equipment has been designed and manufactured to exceed con ned space require-ments and
regulations in order to meet the needs of the discriminating user for operation by personnel working in and around a
con ned space.
Safe, ef cient and trouble-free operation and maintenance of the system requires that anyone who will be operating,
maintaining, or inspecting the equipment, read, understand and follow all the operation, safety, maintenance, and
inspec-tion instructions contained within this manual. This manual covers the WP-08 Series Axial Ventilator. Use the
Table of Contents as a guide to nd speci c information.
Keep this manual handy for frequent reference and to pass on to new operators.
This product is a part of a system for con ned space
ventilation operations. The user must read, understand
and follow the instructions contained in this manual
before using this equipment. Failure to follow these
instructions could result in serious injury or death.
Speci cations
Introduction:
Used to exhaust moisture laden air and to introduce drier outdoor air and used to push or pull air-positive or nega-
tive air displacement with great force
Axial fans can also be used as ventilators, circulators and simply as fans
Perfect for exhausting fumes, marine industry and ventilating con ned spaces, spot cooling and perimeter crawl
spaces
Made of high-density Polyethylene and designed to take on the toughest of jobs to ensure many years of satis ed
use
Applications:
It is suitable for tunnel, basement, ship building, electric soldering and waste gas exhaust out Perfect for air circulation, carpet and oor drying and spot cooling Can easily be stacked during use, transportation and storage Large fan blades generates greater air ow for increased ef ciencyOff-center handle for rugged professional use and easier lifting and handling High density polymer housing for durability
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04 Page 7
3.0 - Con guration & Assembly
Upon initial receipt of the WP-08 Series Axial Ventilator, inspect the packaging for any evidence that the product may
have been damaged in shipment. While unpacking the product, inspect all of the components for damage. If damage
to any of the components is discovered, Alert the shipping carrier immediately of the damage to the shipment.
Refer to the following parts breakdown diagram and the accompanying parts list (Figure #3.1) for information and iden-
ti cation purposes. The parts list table displays applicable part numbers, descriptions, and quantity per assembly.
3.1 Parts Diagram & List
Figure 3.1: #WP-08 Series Axial Ventilator
Parts Diagram & Parts List
ITEM DESCRIPTION QUANTITY
1 SCREW 10
2 WASHER 10
3 WIRE GRILL - FRONT 1
4 WIRE GRILL - REAR 1
5 NUT 1
6 FLAT WASHER 1
7 FAN BLADE 1
8 BLADE BACKING WASHER 1
9AC MOTOR1
10 MOTOR MOUNT 1
11 VENTILATOR HOUSING 1
12 RIVET 4
13 RUBBER FOOT 4
14 TYPE SJTW - SUPPLY CORD, TERMINATED IN A 3-WIRE GFCI DEVICE 1
15 CAPACITOR 1
16 STRAIN RELIEF - WATERTIGHT 2
17 ACCESS PANEL 1
18 SELF TAPPING SCREW 4
19 LABEL - SPECIFICATIONS/DATA SHEET 1
12
4
14
9
19 11 10 7 65321
15
17
18
13
12
8
16
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
Page 8
3.2 Wiring Diagram
Shown below in Figure 3.2, is a wiring diagram of the motor and the cordset.
Figure 3.2: WP-08 Series
Wiring Diagram
GFCI DEVICE
(BLK 1)
(BLK 2)(GREY)
(BROWN)
(WHT)
(GRN) (YLW/GRN)
(BLU)
MOTOR
CAPACITOR
VENTILATOR HOUSING
(BLK)
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04 Page 9
4.0 - Product Operation
The WP-08 Series Axial Ventilator is built from a high density polyethylene housing, which has a high resistance to
chemicals and extreme temperatures. The internal components are made from alloy steel, aluminum, and/or
composite materials. The WP-08 Series Axial Ventilator is specically designed for confined space applications. All
speci cations, instructions, and procedures provided within this manual or upon Specication Documents are based
upon and only valid for usage with accessories.
4.1 - Product Description & Capabilities
The following section will address the capabilities and the general operation of the WP-08 Series Axial Ventilator. The
instructions contained within this section should be adhered to each and every time the product is used. Any person
tasked with installing or operating the piece of equipment should be familiar with these procedures.
Materials & Construction
• Main Structure: - Polyethylene Housing
• Hardware - Plated Steel
Features:
Low Maintenance
Speci cally designed to provide a completely por-
table source of fresh air
Model Speci cations & Performance
Voltage: 115VAC, 60 Hz
Amperage: 2.6
Pole: 2P
Horse Power: 1/3 (.248kw)
Free Air: 844 cfm
One 90° Bend 458 cfm
Two 90° Bends 295 cfm
Axial Ventilator
Power: Electric
Width: 13.13 in (33.35 cm)
Length: 13.25 in (33.66 cm)
Height: 14.17 in (36.0 cm)
Weight: 16.80 lbs (7.62 kg)
Figure #4.1: WP-08 Series
Axial Ventilator
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
Page 10
Prior to Operation, the WP-08 Series Axial Ventilator should be con gured and prepared according to the following
guidelines.
1. Pre-Operation Inspection:
It is necessary to perform a visual inspection, each time, prior to using the product. If deciencies are found, remove
the product from service and contact a repairer. The following checklist coupled with Figure #4.2a should be used as
a guide to determine whether the equipment is in good operating condition prior to usage. Equipment that is not in
good condition can endanger the safety of those working around it.
The Pre-Operation Visual Inspection is not limited to, but must include the following items;
a. Check the ventilator inlet and outlet guard screens for obstructions.
b. Remove any objects around the immediate area that could be drawn into the ventilator intake.
c. The cordset is properly attached to the ventilator.
d. The rubber feet are attached.
4.2 - Product Set-Up & Operation
Figure #4.2a: WP-08 Series Axial Ventilator
Pre-Operation Inspection Points
Rubber Feet
Outlet Guard
Inlet Guard
TYPE SJTW - Supply cord, Terminated in a 3-wire
GFCI device
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04 Page 11
2. Setup of WP-08 Series Axial Ventilator:
Choose a location where installation will provide suitable proximity to the work area yet minimize obstructions during
use. Once a location is chosen;
a. Ventilator should be placed 1.5 meters upwind where possible, from the con ned space, and have its inlet pointed
into the wind. This will reduce the chance of contamination being blown into the con ned space.
(Refer to Fig. #4.2b)
b. Plug the ventilator power cord into a properly grounded and rated receptacle.
c. Extend and place the ventilator hose as required.
d. When ventilator operation is no longer required, unplug the power cord. Coil and store the power cord in the opening
of the molded handle, or wrap the cord around the molded legs.
4.2 - Product Set-Up & Operation (continued)
Important Notes:
During con ned space entry operations, it should not be assumed that the ventilator will maintain the air inside the con ned space at a safe condition. When the ventilator is in use, the air inside the con ned space
should be monitored continuously for the presence of poisonous gases and/or toxic fumes.
Ensure that the ventilator provides positive air ow the entire time during usage. The Axial Ventilator can be used with an accessory alarm that alerts the entrants when & if positive ventilation is lost.
The Axial Ventilator can also be used in conjunction with a WP-08 Series Hose & Canister that connects to the Ventilator and has storage built-in for the hose.
Conned Space
1.5 m
Ventilation Hose
Ventilator
Air Flow
Figure #4.2b
125966-001 - Product Manual, WP-08 Series Axial Ventilator - Revision 03 - 2014-08-04
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Onedry HEFA0600 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI