E-Mon 62-0384 Split-Core Current Sensors User manual

Type
User manual

This manual is also suitable for

E-Mon E-Mon 62-0384 Split-Core Current Sensors enable precise monitoring of electrical current in various applications. Designed for use with E-Mon D-Mon meters, these sensors feature a split-core design for easy installation around existing conductors. They provide accurate readings for a wide range of amperages, from 25 to 3200 amps, and can be used for single-phase or three-phase systems. The current sensors extend the capabilities of E-Mon meters, allowing for versatile monitoring of electrical usage in residential, commercial, or industrial settings.

E-Mon E-Mon 62-0384 Split-Core Current Sensors enable precise monitoring of electrical current in various applications. Designed for use with E-Mon D-Mon meters, these sensors feature a split-core design for easy installation around existing conductors. They provide accurate readings for a wide range of amperages, from 25 to 3200 amps, and can be used for single-phase or three-phase systems. The current sensors extend the capabilities of E-Mon meters, allowing for versatile monitoring of electrical usage in residential, commercial, or industrial settings.

62-0384-02
INSTALLATION INSTRUCTIONS
Split-Core
Current Sensors
E-Mon
1985 Douglas Drive North
Golden Valley, MN 55422
www.emon.com
62-0384_B.fm Page 1 Monday, November 10, 2014 11:03 AM
SPLIT-CORE CURRENT SENSORS
62-0384—02 2
CURRENT SENSOR ASSEMBLY
STEP 1: For each phase being monitored, you will
need one two-piece current sensor assembly. (A
three-phase meter will require three (3) current
sensor assemblies.) Open the two-piece current
sensor assembly by releasing the nylon clamp
using a flathead screwdriver.
Fig. 1. 25-200 Amp Interior Dim: 1"x 6/16”.
STEP 2: Using a flathead screwdriver, press the
tab on the nylon clamp to open the current sensor
assembly.
Fig. 2. 800-1600 Amp Interior Dim: 3.375"x 6".
STEP 3: Reassemble current sensor assembly
around the conductor(s) to be monitored. Be sure
that the current sensor halves marked “Load” are
both facing the load side of the conductor being
monitored. The colored arrow will be on the source
side of the conductor being monitored and MUST
be pointed in a clockwise direction around the
conductor being monitored. Tighten nylon clamp to
complete assembly. Using a flathead screwdriver,
press the tab on the nylon clamp to open the
current sensor assembly
Fig. 3. The arrow on the current sensor assembly should point clockwise.
IMPORTANT
When looking from the source side of the conductor(s) being monitored, you
should see the arrow on the current sensor assembly, and the arrow should
be pointing clockwise around the conductor(s) being monitored.
If the arrow is not on the source side, inaccurate readings may result.
Source
Load
62-0384_B.fm Page 2 Monday, November 10, 2014 11:03 AM
SPLIT-CORE CURRENT SENSORS
3 62-0384—02
All current sensors are split-core type. (Solid-core option available; specify when
ordering.) All current sensors shipped in complete sets of three (3).
The above split-core current sensors are supplied with E-Mon D-Mon® Class 1000,
2000, 2100, 3000, 4000 and 4100 meters.
Current sensors can be installed up to 2000 feet away from meter (500 feet for Class
3000 meters). Leads supplied are 3' in length and can be extended up to 2000 feet
using low voltage #14-22 AWG wire. (stranded/twisted not required) See local
electrical codes for proper sizing. (Continued on next page)
Model Numbers
Model # Amperage Interior Dim.
CS25 25 amp 7/8” x 1 1/2”
CS50 50 amp 7/8” x 1 1/2”
CS100 100 amp 7/8” x 1 1/2”
CS200 200 amp 7/8” x 1 1/2”
CS400 400 amp 1 1/2” x 2 3/4”
CS800 800 amp 3 1/4” x 4 1/2”
CS1600 1600 amp 3 1/4” x 4 1/2”
CS3200 3200 amp 5 7/16” x 7 7/8”
25-200 Amp
Interior Dim: 1 1/2” x 2 3/4
Exterior Dim: 4 3/8” H x 3 3/4” W x 1 3/8” D
400 Amp
Interior Dim: 7/8” x 1 1/2”
Exterior Dim: 3 1/8” H x 3 3/4” W x 1 3/8” D
Interior Dim: 3 1/4” x 4 1/2” Exterior Dim: 5
3/4” H x 5 3/8” W 1 3/8” D
Interior Dim: 5 7/16” x 7 7/8” Exterior
Dim: 9 1/4” H x 7 7/8” W x 1 3/8” D
800-1600 Amp 3200 Amp
62-0384_B.fm Page 3 Monday, November 10, 2014 11:03 AM
SPLIT-CORE CURRENT SENSORS
E-Mon
1985 Douglas Drive North
Golden Valley, MN 55422
www.emon.com
® U.S. Registered Trademark
© 2014 E-Mon
62-0384—02 M.S. Rev. 11-14
Printed in United States
By using this E-Mon literature, you agree that E-Mon will have no liability for any damages
arising out of your use or modification to, the literature. You will defend and indemnify E-Mon,
its affiliates and subsidiaries, from and against any liability, cost, or damages, including
attorneys’ fees, arising out of, or resulting from, any modification to the literature by you.
When paralleling current sensors, the meter reading must be multiplied by the number
of sets of current sensors in parallel.
Solid-core current sensors available in 100 & 200 amp configuration.
Specify when ordering.
62-0384_B.fm Page 4 Monday, November 10, 2014 11:03 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

E-Mon 62-0384 Split-Core Current Sensors User manual

Type
User manual
This manual is also suitable for

E-Mon E-Mon 62-0384 Split-Core Current Sensors enable precise monitoring of electrical current in various applications. Designed for use with E-Mon D-Mon meters, these sensors feature a split-core design for easy installation around existing conductors. They provide accurate readings for a wide range of amperages, from 25 to 3200 amps, and can be used for single-phase or three-phase systems. The current sensors extend the capabilities of E-Mon meters, allowing for versatile monitoring of electrical usage in residential, commercial, or industrial settings.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI