TFA 30.5047.54 User manual

Type
User manual

This manual is also suitable for

1514
EXACTO – Digital thermo-hygrometer
EXACTO – Digital thermo-hygrometer
Thank you for choosing this instrument from TFA.
1. Before you use this product
Please make sure you read the instruction manual care-
fully.
Following and respecting the instructions in your manual
will prevent damage to your instrument and loss of your
statutory rights arising from defects due to incorrect use.
We shall not be liable for any damage occurring as a
result of non following of these instructions. Likewise, we
take no responsibility for any incorrect readings or for
any consequences resulting from them.
Please take particular note of the safety advice!
Please keep this instruction manual safe for future refer-
ence.
2. Live healthier by controlling the temperature and
humidity
Checking indoor temperature and humidity can help to
achieve a comfortable and healthy living environment and
may even save you money on heating costs.
Ideally, the indoor temperature should be between 18°C -
22°C and the relative humidity between 40 - 60%.
3. For your safety
This product is exclusively intended for the range of applica-
tion described above. It should only be used as described
within these instructions.
Unauthorized repairs, alterations or changes to the product
are prohibited.
Caution!
Risk of injury:
Keep this instrument and the batteries out of reach of children.
Batteries contain harmful acids and may be hazardous if
swallowed. If a battery is swallowed, this can lead to serious
internal burns and death within two hours. If you suspect a
battery could have been swallowed or otherwise caught in
the body, seek medical help immediately.
Batteries must not be thrown into a fire, short-circuited,
taken apart or recharged. Risk of explosion!
Low batteries should be changed as soon as possible to pre-
vent damage caused by leaking. Never use a combination of
old and new batteries together, nor batteries of different
types.
Wear chemical-resistant protective gloves and safety glasses
when handling leaking batteries.
TFA_No. 30.5047_Anleitung 24.05.2018 16:15 Uhr Seite 8
1716
EXACTO – Digital thermo-hygrometer
EXACTO – Digital thermo-hygrometer
Important information on product safety!
Do not expose the device to extreme temperatures, vibra-
tions or shocks.
Protect it from moisture.
Only suitable for indoor use.
4. Elements
A: Display (Fig. 1):
A 1: Humidity
A 2: Humidity trend arrow
A 3: Max/min values humidity
A 4: Comfort level indicator
A 5: Temperature
A 6: Temperature trend arrow
A 7: Max/min values temperature
B: Buttons (Fig. 2+3):
B 1: UP button B 2: DOWN button
B 3: SET button B 4: °C/°F button
B 5: LIGHT sensor button
C: Housing (Fig. 2):
C 1: Mounting hole
C 2: Magnet
C 3: Stand (fold out)
C 4: Battery compartment
5. Getting started
Remove the protective film from the display.
Open the battery compartment.
Insert two new 1,5 V AAA batteries, polarity as illustrated.
On the display appear the measured temperature and
humidity.
Close the battery compartment again.
6. Temperature display
Press and hold the °C/°F button using a pin to change
between °C (Celsius) or °F (Fahrenheit) as temperature unit.
7. Trend indicator
The trend arrows indicate whether the values for tempera-
ture and humidity are currently increasing, steady or
decreasing.
8. Comfort level
A marking appears on the display to indicate the comfort
level.
TFA_No. 30.5047_Anleitung 24.05.2018 16:15 Uhr Seite 9
1918
EXACTO – Digital thermo-hygrometer
EXACTO – Digital thermo-hygrometer
9. Maximum and minimum values
There are two memory modes for highest and lowest values.
Press the UP or DOWN button in normal mode to enter the
automatic (24hrs) or manual (all-time) reset mode of the
maximum-minimum values.
All-time mode: As soon as the station is active the maxi-
mum and minimum values will be stored.
24hrs mode: The maximum and minimum values will be
reset every 24 hours (from the moment of activation).
9.1 Manual reset
Hold UP button in the respective mode to clear the recorded
high reading.
Hold DOWN button in the respective mode to clear the
recorded low reading.
10. Backlight
Press the LIGHT sensor button or any button to temporarily
activate the backlight.
11. Positioning and mounting of the device
The device can be placed onto any flat surface with the stand
or wall mounted at a chosen location with the mounting hole,
both found at the back of the unit.
Use the magnets at the back of the device for placement on
metal surfaces.
12. Care and maintenance
Clean the device with a soft damp cloth. Do not use solvents
or scouring agents.
Remove the batteries if the device will not be used for an
extended period of time.
Keep the device in a dry place.
12.1 Battery replacement
Change the batteries when the battery symbol appears on the
display.
13. Troubleshooting
Problem Solution
No display Ensure the batteries' polarity
are correct
Change the batteries
Incorrect indication Change the batteries
Use the calibration function
TFA_No. 30.5047_Anleitung 24.05.2018 16:15 Uhr Seite 10
2120
EXACTO – Digital thermo-hygrometer
EXACTO – Digital thermo-hygrometer
14. Calibration function
The thermo-hygrometer allows the user to calibrate the dis-
play of temperature and humidity measurements with an
external, better reference source. The user can make adjust-
ments to the temperature and humidity displays within the
measuring range.
When replacing batteries the calibrated values are deleted
automatically.
15. Calibration of the humidity and temperature display
Press and hold the SET button for 5 seconds.
The display of the humidity flashes.
Press the UP or DOWN button to correct the display of the
humidity.
CALIBRATED appears on the display.
Press SET button shortly to confirm it.
The temperature display flashes.
Press the UP or DOWN button to correct the display of the
temperature.
CALIBRATED appears on the display.
Press SET button shortly to confirm it.
16. Waste disposal
This product has been manufactured using high-grade materials
and components which can be recycled and reused.
Never dispose of empty batteries and recharge-
able batteries with ordinary household waste.
As a consumer, you are required by law to take
them to your retail store or to an appropriate col-
lection site depending on national or local regu-
lations in order to protect the environment
The symbols for the contained heavy metals are:
Cd = cadmium, Hg = mercury, Pb = lead
This product is labelled in accordance with the
EU Waste Electrical and Electronic Equipment
Directive (WEEE).
Please do not dispose of this product in ordinary
household waste. As a consumer, you are
required to take end-of-life devices to a designat-
ed collection point for the disposal of electrical
and electronic equipment, in order to ensure
environmentally-compatible disposal.
17. Specifications
Temperature range indoor -20 °C… 70°C (-4 °F …158 °F)
Humidity range 1 … 99%
Temperature accuracy ±1°C
TFA_No. 30.5047_Anleitung 24.05.2018 16:15 Uhr Seite 11
2322
EXACTO – Digital thermo-hygrometer
EXACTO – Thermo-hygromètre digital
Temperature resolution 1°C
Humidity accuracy ±3 % at 35 …75 %,
otherwise ±5 %
Humidity resolution 1 %
Power consumption: Batteries 2 x 1,5 V AAA
(not included)
Dimensions 74 x 26 (48) x 90 mm
Weight 106 g (device only)
TFA Dostmann GmbH & Co. KG,
Zum Ottersberg 12, D-97877 Wertheim, Germany
No part of this manual may be reproduced without written consent of TFA
Dostmann. The technical data are correct at the time of going to print and
may change without prior notice.
The latest technical data and information about your product can be found
by entering the product number on our homepage.
www.tfa-dostmann.de 05/18
Nous vous remercions d'avoir choisi l'appareil de la société
TFA.
1. Avant d'utiliser votre appareil
Veuillez lire attentivement le mode d'emploi.
En respectant ce mode d'emploi, vous éviterez d'endom-
mager votre appareil et de perdre vos droits légaux en
cas de défaut si celui-ci résulte d’une utilisation non-
conforme.
Nous n'assumons aucune responsabilité pour des dom-
mages qui auraient été causés par le non-respect du pré-
sent mode d'emploi. De même, nous n’assumons aucune
responsabilité pour des relevés incorrects et les consé-
quences qu’ils pourraient engendrer.
Suivez bien toutes les consignes de sécurité !
Conservez soigneusement le mode d'emploi !
2. Vivre en meilleure santé en contrôlant la tempéra-
ture et l'humidité
Idéal pour le contrôle de la température et de l'humidité
ambiantes et d'un climat intérieur sain, il économise égale-
ment les coûts de chauffage.
Idéalement, la température interne devrait être de 18 °C -
22 °C et l'humidité relative de 40 - 60%.
TFA_No. 30.5047_Anleitung 24.05.2018 16:15 Uhr Seite 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

TFA 30.5047.54 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI