5
1.4. Technical parameters:
- electrical parameters (tab.3)
- mechanical parameters (tab.4)
- operation safety (tab.5)
- operation parameters (tab.6)
Electrical parameters (tab. 3).
Supply voltage 230V/AC (-15%/+10%)
Supply frequency 50Hz (47÷53Hz)
PSU power P 21W max.
Current consumption 0,16 A max. (2,5 A „ cold boot”)
Output voltage 11,0V÷13,8Vdc – buffer operation
10,0V÷13,8Vdc – battery assisted operation
Output voltage setting, escalation and keeping
time
60ms/40ms/10ms @ Inom., Uac=min.
Voltage setting range
11,5 V÷14,0 V
Voltage adjustment range
± 1%
Ripple voltage
30mV p-p max.
Output current
1,5 A max.
Current consumption by PSU systems
25 mA max.
Battery charging current
200mA max. (@7Ah, U bat.=10,0V) (± 5%)
SCP short-circuit protection
200% ÷ 250% of supply power – limitation of current and/or fuse
failure in the battery circuit (fuse-element replacement required)
OLP overload protection
110% ÷ 150% (@25ºC÷55ºC) of power supply – current limitation
with the PTC automatic fuse, manual restart (the fault requires
the disconnection of the DC output circuit)
SCP short-circuit protection in the battery circuit
and reverse polarity protection
2A- current limitation, F2 fuse (failure requires replacement of the
fuse-element)
Overvoltage protection OVP U>22V varistor, automatically recovered
Excessive discharge protection UVP U<10,0 V (± 5%) – disconnection of (-BAT) battery
Technical outputs:
- COM, NC, NO output indicating the fault to the
AC supply
-
R-relay type, 1A@ 30Vdc/50Vac max.
Time lag about 5s/140s/1040s/2h20m30s (+/-1%)
Normal status: activated COM-NO,
Failure status: activated COM-NC
Optical indication: power-supply
- AC diode indicating the AC supply status
- LB diode indicating the battery charging
process
- AUX diode indicating DC supply status at the
power-supply output
Optical indication: power-supply front panel
- AC diode indicating the AC supply status
- AUX diode indicating DC supply status at the
power-supply output
- red, normal status, permanently illuminated,
failure: no illumination
- red, illuminated with light with intensity depending on battery
charging current
- green, normal status, permanently illuminated,
failure: no illumination
- red, normal status, permanently illuminated,
failure: no illumination
- green, normal status, permanently illuminated,
failure: no illumination
F1 fuse
F2 fuse
F 2A/250V
T 250 mA/ 250V
Mechanical parameters (tab.5)
Casing dimensions 185 x 100 x 102 (WxHxD) [mm] (+/- 2)
Fixation On DIN rail TH35
Battery space 1,2h/12V (SLA) max. (casing of 7Ah/DIN – AWO417 battery)
Net/gross weight 1,7/1,8 kg
Casing color RAL 9003
Closing Cheese screw x 2 (at the front)
Connectors Power-supply: Φ0,63-2,50 (AWG 22-10)
Outputs: Ф0,41÷1,63 (AWG 26-14)
BAT battery outputs: 6,3F-2,5, 30cm
TAMPER output: wires, 30cm
Notes The casing is distant from the assembly surface so that cables can be installed