Eaton Velos Operating instructions

Type
Operating instructions
Installation and Operation Manual
Velos Exit Sign
D
G:
G:
Y:
Y:
OK
TEST
G Y
CBA
230VAC
Table of Contents
Installation - Maintenance
General Information
1. Safety information
2. Scope of Operation
3. General product information
4. Disposal / Recycling
Installation & Operating instructions
5. Step by step mounting instructions
6. Mains Operation
7. Emergency Operation
8 Autotest Operation
9. Dimensions
10. Order codes
SAFETY INSTRUCTIONS
Ÿ The device shall only be used for its intended purpose and in undamaged and
awless condition
Ÿ Only genuine Eaton spare parts may be used for replacement and repair
Ÿ Observe the national safety rules and regulations to prevent accidents as well as
the safety instructions included in these instruction leaet
.......................................................................... 4
.......................................................................... 4
.......................................................................... 4
.......................................................................... 5
.......................................................................... 6
.......................................................................... 6
.......................................................................... 5
.......................................................................... 3
.......................................................................... 5
.......................................................................... 7
230VAC
.......................................................................... 4
3
Velos Exit Sign 1-05-246E - Installation & Operation manual www.eaton.com
DK
SLO
HR
VC
EE
LT
Velos Exit Sign - Installation / Maintenance
Norsk
A) Batteri tilknyttet – lader.
B) Lader ikke. Service kreves
C) Batteriet må skiftes når påstemplet
nøddriftid ikke oppnås. Utføres av
kompetent personell.
D) Selvtest indikasjon
NO
Velos Exit Sign - General Information
1. Safety Information
Observe the national safety rules and regulations to
prevent accidents as well as the safety instructions
included in these instruction leaet.
2. Scope of Operation
The Velos family of emergency lights is designed and
equipped with technical solutions that make it suitable
for a wide range of applications. A complete range of
accessories such as the recessed base for false ceiling
installations, lateral and back base as well as suspension
options allow for a variety of mounting positions.
With the choices of many ISO and EURO exit signs
and other custom emergency signs, the Velos LED
range is appropriate for emergency signaling
requirements in multiple of places such as ofces,
restaurants, hotels, hospitals and general
commercial applications
Velos front view
3. General Product Information
Light Source:
24 LED stripe source with
a lifetime of more than
60.000 hours.
Materials:
Base and reector unit in
PC, PMMA.
Operation:
Maintained, slave and
CBS models available.
Autonomy from 1h up to
3h.
Adjustable brightness
function to 66% in mains
operation.
Functional test button.
Telecommand and
Inhibition operation.
Self contained Autotest
models available.
Installation:
Ceiling, wall, recessed,
suspended through ropes
or metal pipes and lateral
installation.
No special tools required.
Applications:
Schools, universities,
public administration,
commercial environments.
Hotels, restaurants,
meeting
rooms, ofces, shops,
cinemas, theaters,
museums.
Areas with large heights
and long distance view
requirements.
4
0%
12h
IP20
0
+40 C
0
+5 C
1h 100%
12h
24h charge for
optimal operation
recyclable parts complying
with WEEE directive
designed for indoor use
temperature range
0 0
+5 C to +40 C
class II
Velos Exit Sign 1-05-246E - Installation & Operation manual www.eaton.com
4. Disposal / Recycling
When disposing of faulty equipment, observe the valid
regulations for recycling and disposal. Plastic parts are
marked with the appropriate symbols.
The light sources of Velos Exit Signs are not
replaceable. When a light source reaches its end of life
the whole sign shall be replaced.
260,00mm
1,5-2,5
Velos Exit Sign - Installation & Operating instructions
5. Step by step Mounting Instructions
EX500
B+ A-
A- B+
1-2,5
S2
L
N
L1
S1
L
N
L1
S1 L1
7. Emergency Operation
Telecommand wiring
SWITCH
A- B+
1-2,5
Inhibition wiring
6. Mains Operation
Maintained operation
ECO operation
Max = 50mA (100%)
Eco = 33mA (66%)
5
Velos Exit Sign 1-05-246E - Installation & Operation manual www.eaton.com
1
2
3a
4a
3b
4b
9. Dimensions
dimensions - PSU
69mm
292mm
50mm
292mm27mm 27mm
346mm
69mm
50mm
69mm
224mm
346mm
30 meters
distance view
40 meters
distance view
69mm346mm
324mm
dimensions - Emergency signs
6
TLU500
B+ A-
- + - +
+ -
1-2,5
8. Autotest Operation
Telecommand operation
Autotest indications
G Y
G:
G:
Y:
Y:
OK
TEST
Functional test, every week
Duration test, every 10 weeks
EX500
B+ A-
Manual test
Velos Exit Sign - Installation & Operating instructions
Velos Exit Sign 1-05-246E - Installation & Operation manual www.eaton.com
Velos exit sign consist of 2 parts, the PSU unit and
the Emergency sign. In order to make your choice you
need to add 2 lines in your ordering for both parts of Velos.
PSUs
Velos PSU 1,5h NiCD
Velos PSU 3h NiCD
Velos PSU MAINS with V-CG-S2
Velos PSU Mains
Velos PSU 1h NiMH Autotest
Velos PSU 3h NiMH Autotest
Order code
Description
O-ESC
O-ESC-3H
O-ES-CG-S
O-ESMAINS
O-ESM-AT
O-ESM-AT-3H
Accessories
O-ESA-RB
O-ESA-FLEX
O-ESA-RSA
O-ESA-PS30
O-ESA-LMB
O-ESA-BMB
VeLos Recessed Base
VeLos Wall FLEXI Joint
VeLos Rope Suspension adjustable 150cm
VeLos Pipe Suspension 48cm
Velos Lateral Mounting Base
Velos Back Mounting Base
Order code
Description
Emergency Signs
Velos pictogram EURO LEFT/RIGHT 30m
Velos pictogram EURO DOWN/BLANK 30m
Velos pictogram EURO DOWN/DOWN 30m
Velos pictogram EURO UP/BLANK 30m
Velos pictogram EURO UP/UP 30m
Velos pictogram EURO Lateral to Room
Velos pictogram EURO Lateral to Wall
Velos pictogram ISO LEFT/RIGHT 30m
Velos pictogram ISO DOWN/BLANK 30m
Velos pictogram ISO DOWN/DOWN 30m
Velos pictogram ISO UP/BLANK 30m
Velos pictogram ISO UP/UP 30m
Velos pictogram ISO Lateral to Room
Velos pictogram ISO Lateral to Wall
Velos pictogram Russian Exit 30m
Velos pictogram ISO LEFT/RIGHT 40m
Order code
Description
O-ESP-ELR
O-ESP-ED
O-ESP-EDD
O-ESP-EU
O-ESP-EUU
O-ESP-E2R
O-ESP-E2W
O-ESP-ILR
O-ESP-ID
O-ESP-IDD
O-ESP-IU
O-ESP-IUU
O-ESP-I2R
O-ESP-I2W
O-ESP-RUS
O-ESP40-ILR
Velos pictogram ISO DOWN/DOWN
40m
VeLos Pictogram ISO UP/BLANK 40m
VeLos Pictogram ISO UP/UP 40m
VeLos Pictogram ISO DOWN/BLANK
40m
Velos Hydrant pictogram 30m
Velos Fire hose down 30m
Velos Fire hose & extinguisher 30m
Velos pictogram Wheel ISO LEFT/RIGHT
30m
Velos pictogram Wheel ISO
DOWN/DOWN 30m
Velos pictogram Wheel ISO LEFT/RIGHT
40m
Velos pictogram Wheel ISO
DOWN/DOWN 40m
Order code
Description
O-ESP40-IDD
O-ESP40-IU
O-ESP40-IUU
O-ESP40-ID
O-ESP-H
O-ESP-FHD
O-ESP-FH-EXT
O-ESP-WIRL
O-ESP-WIDD
O-ESP40-WILR
O-ESP40-WIDD
7
Emergency sign
of Velos
(order separately)
PSU unit of
Velos
(order separately)
10. Order codes
A variety of pictograms are available for Velos Exit Sign.
Please contact your local sales representative for
additional information in regards to the layouts available.
WYJSCIE
EWAKUACYJNE
Velos Exit Sign 1-05-246E - Installation & Operation manual www.eaton.com
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Cooper Univel S.A.
Thessalonikis 88
60134 Katerini, Greece
© 2015 Eaton
All Rights Reserved
Printed in EU
Publication No. 1-05-246E
September 2015
Eaton Industries Manufacturing
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges, Switzerland
Eaton.eu
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Eaton Velos Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI