10
TROUBLESHOOTING
SYMPTOM
Fans/Light Turn On
and Off Unexpectedly
SOLUTION
This is caused by
interference, change the
code frequency from the
transmitter, and follow
the instructions from
Section 5 again to
operate your transmitter
and fan.
SYMPTOM
Fan Sounds Noisy
SOLUTION
Allow a 24-hour "break in" period.
Most noises associated with a
new fan will go away during this
time.
Make sure the screws that attach
the fan blade holder to the motor
hub is tight.
Make sure outlet box is secured
to building structure, if
necessary use the wood screws
provided to further secure
outlet box to joist.
Make sure hanger bracket is
secure to the outlet box, screws
are tight.
SYMPTOM
Fan will not start
SOLUTION
Check to make sure the wall switch is
turned on.
Check circuit fuses or breakers.
Caution! Make sure the power is turned
off before performing the following steps.
Remove canopy and check wire
connections.
Check wall control transmitter connections
(if applicable).
Note: Fan must be installed at a maximum
distance of 40 feet from the transmitting
unit for proper signal transmission
between the transmitting unit and the
fan's receiving unit.
SYMPTOM
Fan Wobble
SOLUTION
NOTE: All blade sets are grouped by
weight. Because wood and plastic
blades vary in density, the fan may
wobble even though blades are
matched.
Make sure outlet box is secured to
building structure, if necessary use the
wood screws provided to further secure
outlet box to joist.
Make sure hanger bracket is secure to the
outlet box, screws are tight.
If a Balancing kit is provided follow the
instructions included with the balancing
kit to help correct any excessive wobble.