Unbranded H5HK009Q-01, 9KW, 1-Stage, 240 VAC, 3-Phase Product information

Type
Product information
WIRING DIAGRAM
H5HK009Q-01
NOTES:
1. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same
gauge size and temperture rating.
2. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details.
3. Use copper conductors with minimum temperature rating of 60C for supply connections.
9KW, 1-Stage, 240 VAC, 3-Phase Electric Heater Kit
Legend
Field Wiring
Factory Wiring:
Low Voltage
High Voltage
710098A (Replaces 7100980)
3/00
¢710098;¤
L1
L2
L3
UNIT TERMINAL
BLOCK
GND
PLUG HOUSING, 6 PIN
SEQUENCER
PLUG HOUSING, 3 PIN
L1 T1
L2
L3
T2
T3
CONTACTOR
LIMITLIMIT
BK W/WH
BK W/WH
RD W/BK
RD W/BK
YE W/BK
YE W/BK
BK W/WH
RD W/BK
YE W/BK
WHITE
BLACK
WHITE
BLACK
WHITEWHITE
BLACK
WHITE
GRAY
RED
RED
1
2
3
4
5
6
M1 M2
M3 M4
12
12
1 2 3
1 2 3
CAP HOUSING, 3 PIN