Intermec ScanPlus S Series Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Intermec ScanPlus S Series Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
P/N 0-360049-02
ScanPlus S Series
Installation Manual
2 ScanPlus S Series - Installation Manual
This manual is compatible with EasySet System - spssen.cmd - 980610
This manual contains full setup information for all ScanPlus S Series scanners. When installing the scanner, make sure that
the host system is turned off before you connect the cables. Basic setup procedure: 1. Plug in your product. 2. Select the
terminal / cash register used in your application (section 3). 3. Select the symbologies you need (section 5). 4. Test your
setup (appendix D). The mark (*) = default already set by step 2.
The ScanPlus S/ST is a Class 2 Laser Scanner. Fix the laser warning labels onto the product if they are not already present.
CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM.
Regularity Statements
This product complies with directives 89/336/EEC and 73/23/EEC for :
Emission Immunity Low voltage
EN50081-1 (1992) EN50082-1 (1992) EN60742 (1995)
EN55022 (1995) Class B EN61000-4-2 (1995)
EN61000-3-2 (1995) EN61000-4-3 (1996)
EN61000-3-35 (1995) EN61000-4-4 (1998)
USA: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CANADA: This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
AUSTRALIA-NEW ZEALAND: This equipment has been tested and found to conform to the directives
concerning Class B digital devices, prescribed by the Australian and New-Zealander standard AS/NZS 3548
defined by the Spectrum Management Agency.
The information contained in this manual is for informational purposes only and is subject to change without notice. No part of
this leaflet may be copied or reproduced in any manner without the prior written permission of Intermec Technologies
Corporation.
ScanPlus products are covered by patents issued or pending in the USA and other countries.
© Intermec Technologies Corporation All Rights Reserved
North America / Asia Pacific / Latin America
6001 36th Avenue West
PO Box 4280
Everett WA 98203-9280
Tel : +1 425 348 2600
Fax : +1 425 348 2833
Europe / Middle East / Africa
Sovereign House
Vastern Road
Reading RG1 8BT
England
Tel : +44 118 987 9420
Fax : +44 118 987 9416
Internet :
http ://www.intermec.com
email :
Contents
ScanPlus S Series - Installation Manual 3
Contents
1. Using EasySet ..............................................................................................9
online setup with special download cable 0-605032-00..........................10
online setup with RS-232 cable 0-364032-00 ........................................11
2. Reset all parameters...................................................................................13
3. Terminal / cash register used in your application ..........................................15
keyboard wedge...................................................................................17
IBM PC AT and compatible........................................................18
DEC VT 220, 320, 420...............................................................19
RS-232................................................................................................20
laser emulation.....................................................................................22
wand emulation....................................................................................23
IBM 46xx cash registers .......................................................................25
OCIA cash registers.............................................................................26
4. Data transmission settings...........................................................................27
keyboard wedge...................................................................................28
preamble...................................................................................28
symbology identifier...................................................................29
postamble .................................................................................33
special keys interpretation (Code 39) .........................................35
special keys transmission ..........................................................38
inter-character delay..................................................................39
inter-message delay..................................................................40
end-of-transmission keyboard character status...........................41
RS-232................................................................................................42
baud rate...................................................................................42
data bits....................................................................................43
parity.........................................................................................43
stop bits....................................................................................44
Contents
4 ScanPlus S Series - Installation Manual
hardware/software protocols timeout.......................................... 44
ENQ ......................................................................................... 45
ACK.......................................................................................... 45
NAK.......................................................................................... 46
XON / XOFF software protocol................................................... 47
RTS / CTS hardware protocol.................................................... 48
preamble................................................................................... 49
preamble / postamble................................................................ 49
symbology identifier................................................................... 50
postamble................................................................................. 54
LRC (longitudinal redundancy check)......................................... 55
inter-character delay.................................................................. 55
inter-message delay.................................................................. 56
laser emulation .................................................................................... 58
transmitted symbology type....................................................... 58
margin size ............................................................................... 58
logical signal state during transmission ...................................... 59
logical signal state outside transmission..................................... 59
inter-message delay.................................................................. 59
wand emulation.................................................................................... 61
transmitted symbology type....................................................... 61
margin size ............................................................................... 61
logical signal state during transmission ...................................... 62
logical signal state outside transmission..................................... 62
pulse duration........................................................................... 62
inter-message delay.................................................................. 64
IBM 46xx cash registers....................................................................... 65
inter-message delay.................................................................. 65
OCIA cash registers............................................................................. 66
inter-character delay.................................................................. 66
inter-message delay.................................................................. 67
Contents
ScanPlus S Series - Installation Manual 5
5. Symbologies...............................................................................................69
Codabar...............................................................................................70
start/stop...................................................................................70
CLSI library system ...................................................................71
check digit (AIM recommendation).............................................71
barcode length ..........................................................................72
Code 39...............................................................................................74
format .......................................................................................74
start/stop...................................................................................78
check digit.................................................................................79
barcode length ..........................................................................81
Code 93...............................................................................................82
barcode length ..........................................................................82
Code 128 / EAN 128 ............................................................................84
EAN 128 identifier......................................................................84
CIP 128 French pharmaceutical codes.......................................85
FNC1 separator character (EAN 128 norms) ..............................85
barcode length ..........................................................................86
Interleaved 2 of 5 .................................................................................87
check digit.................................................................................87
barcode length ..........................................................................88
Matrix 2 of 5.........................................................................................90
barcode length ..........................................................................90
MSI Code.............................................................................................92
check digit.................................................................................92
barcode length ..........................................................................93
Plessey Code.......................................................................................94
check digit.................................................................................94
barcode length ..........................................................................95
Standard 2 of 5 ....................................................................................96
format .......................................................................................96
Contents
6 ScanPlus S Series - Installation Manual
check digit mod 10.................................................................... 96
barcode length.......................................................................... 97
UPC / EAN .......................................................................................... 99
add-on digits............................................................................100
check digit................................................................................101
UPC number system................................................................102
re-encoding UPC-A, UPC-E, EAN-8..........................................103
6. Operating settings......................................................................................105
trigger activation .................................................................................106
trigger operating scenarios .......................................................107
standard mode.........................................................................109
standard mode with aiming beam..............................................110
energy saver mode...................................................................110
trigger read duration.................................................................111
flashing mode.....................................................................................112
data decoding security ........................................................................113
predefined security levels.........................................................113
consecutive same read data validation......................................114
timeout between identical consecutive codes ............................114
timeout between different consecutive codes.............................115
beeps / green indicator LED................................................................116
volume.....................................................................................116
note (tone frequency) ...............................................................116
power-up beeps / power-up LED...............................................117
good read beeps......................................................................117
good read LED.........................................................................119
7. Configuration modes and utilities................................................................121
RS-232 slave mode.............................................................................124
temporary configuration mode.............................................................126
A. ASCII character codes...............................................................................127
Contents
ScanPlus S Series - Installation Manual 7
B. Additional preamble / postamble characters—Keyboard wedge.................. 143
C. Number codes.......................................................................................... 149
D. Test codes................................................................................................151
Index ............................................................................................................ 153
Contents
8 ScanPlus S Series - Installation Manual
1. Using EasySet
ScanPlus S Series - Installation Manual 9
1. Using EasySet
- offline setup
1. select your Intermec product in EasySet ("Select reader" icon over the product image)
2. double-click the setup commands in EasySet to send them to the setup sheet
3. print out the setup sheet and read the configuration codes
- online setup : which cable ?
- products with cable P/N x-xx5xxx-xx require the special download cable configuration kit
for full online setup (if you use RS-232 cable 0-364032-00 with these products, for certain
data transmission settings you must connect your normal product cable and read the codes
from the setup sheet !!!)
- all other products can use RS-232 cable 0-364032-00 for online setup (see the separate
instructions in this section) or special download cable 0-605032-00 provided in the special
download cable kit (includes power supply for cable and cd-rom)
special download cable kit P/N
Europe 0 - 9 0 0 0 2 9 - 0 2
North America 0 - 9 0 0 0 2 9 - 0 3
UK 0 - 9 0 0 0 2 9 - 0 4
1. Using EasySet
10 ScanPlus S Series - Installation Manual
online setup with special download cable 0-605032-00
special download cable 0-605032-00
- online setup with special download cable 0-605032-00 :
1. connect the special download cable to the serial port of your PC
2. connect the power supply to the special download cable and provide electrical power
3. select your Intermec product in EasySet ("Select reader" icon over the product image)
4. disconnect your product cable from your product
5. connect your product cable to the special download cable (necessary to ensure full interface
compatibility !!!)
6. connect your product to the special download cable
7. open the "Configure communication PC/Reader" dialog box in the "Reader" menu
8. select the COM serial port your product is connected to and select no parity, 8 data bits,
19200 bauds
9. select the "Send to reader" checkbox under the commands window
10. double-click on the setup commands to send them directly to your product (they are also
sent to the setup sheet)
11. connect your product cable to your product when you have finished online setup
1. Using EasySet online setup with RS-232 cable 0-364032-00
ScanPlus S Series - Installation Manual 11
online setup with RS-232 cable 0-364032-00
RS-232 direct cable 0-364032-00
- online setup with RS-232 cable 0-364032-00 :
1. connect the RS-232 cable to your product if it is not already connected
2. connect the RS-232 cable to the serial port of your PC
3. connect the power supply to the RS-232 cable and provide electrical power
4. select your Intermec product in EasySet ("Select reader" icon over the product image)
5. read the "RS-232 online setup mode" code (send it to the setup sheet and print it out, or
read it from the Getting Started Guide you received with your product)
6. open the "Configure communication PC/Reader" dialog box in the "Reader" menu
7. select the COM serial port your product is connected to and select no parity, 8 data bits,
19200 bauds
8. select the "Send to reader" checkbox under the commands window
9. double-click on the setup commands to send them directly to your product (they are also
sent to the setup sheet)
10. connect your normal product cable to your product (if applicable) when you have finished
online setup
1. Using EasySet online setup with RS-232 cable 0-364032-00
12 ScanPlus S Series - Installation Manual
RS-232 online setup mode
\41\4A\0F\29\60
- only necessary for setup with RS-232 cable 0-364032-00
- double-click the command to send it to the setup sheet
- follow the procedure for online setup with RS-232 cable 0-364032-00
2. Reset all parameters
ScanPlus S Series - Installation Manual 13
2. Reset all parameters
- global reset of all parameter settings - useful for a first-time setup or for a fresh start with a new
application
- default settings are indicated by (*)
reset factory defaults
\46\42\60
- resets all configuration parameters to their default values and cancels
the terminal / cash register selection
- after a global reset, you must select the terminal / cash register used in
your application (>> next section) and customize your setup
parameters if required
2. Reset all parameters
14 ScanPlus S Series - Installation Manual
3. Terminal / cash register used in your application
ScanPlus S Series - Installation Manual 15
3. Terminal / cash register used in your
application
- necessary for transmission to your terminal / cash register !!!
- look for your system configuration in the terminal / cash register lists in this section or use the
terminal selector
- the number of green LED flashes at power-up indicates the cable / interface configuration of
your product
- green LED always on = no terminal / cash register selected
- energy saver trigger models : if the trigger is activated, you will have to press the trigger to see
the power-up flashes
terminal selector:
- this option only available with EasySet
- use the terminal selector if you don't find your system configuration in
the terminal / cash register lists
interface number selector: [range: 100-20000]
\41\4A\60
- enter a number string and scan End Selection
(Appendix C)
- for special host system configurations
3. Terminal / cash register used in your application
16 ScanPlus S Series - Installation Manual
null interface
\41\4A\00\60
- cancels the current interface settings (useful for
test purposes if you want to read bar codes but
do not want to transmit the data)
- green LED always on = no terminal / cash
register selected
- reselect your terminal / cash register and
customize your data transmission settings (if
required) to return to normal operation
3. Terminal / cash register used in your application keyboard wedge
ScanPlus S Series - Installation Manual 17
keyboard wedge
- connection between a keyboard and the host system
- data is transmitted in keyboard emulation mode
- 7 green LED flashes at power-up
- switch off the host system before you connect the cables and optional power supply !
( )
( )
DIN/mini-DIN adaptor cable
(standard wedge)
standard wedge cable 0-364037-00
DEC VT 220/320/420 cable 0-364037-02
Wyse cable 0-365036-00
"short" MicroBar cables
0-601xxx-xx
CMM-compatible wedge cable 0-364037-03
( )
3. Terminal / cash register used in your application keyboard wedge
18 ScanPlus S Series - Installation Manual
IBM PC AT and compatible
QWERTY English
\41\4A\03\08\60
AZERTY French
\41\4A\03\09\60
QWERTZ German
\41\4A\03\0C\60
QWERTY Swedish / Finnish
\41\4A\03\0D\60
QWERTY Italian
\41\4A\03\0E\60
QWERTY Norwegian
\41\4A\03\0F\60
QWERTY Danish
\41\4A\03\10\60
QWERTY Spanish
\41\4A\03\11\60
QWERTZ Swiss / French
\41\4A\1F\24\60
3. Terminal / cash register used in your application keyboard wedge
ScanPlus S Series - Installation Manual 19
DEC VT 220, 320, 420
QWERTY PC type
\41\4A\06\1A\60
AZERTY PC type
\41\4A\06\1B\60
QWERTZ PC type
\41\4A\06\1E\60
QWERTY PC type Swedish / Finnish
\41\4A\06\1F\60
3. Terminal / cash register used in your application RS-232
20 ScanPlus S Series - Installation Manual
RS-232
- RS-232 C - 2 green LED flashes at power-up
- RS-232 TTL - 4 green LED flashes at power-up
- switch off the host system before you connect the cables and power supply !
RS-232 direct cable 0-364032-00
dual RS-232 cable 0-364032-01
DCE DTE
/