Generac 15kW RD01523GDAE User manual

  • Hello! I am an AI chatbot trained to assist you with the Generac 15kW RD01523GDAE User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4 3 2 1
4 3 1
A
B
A
B
2424 [95.4] OVERALL LENGTH
182
[7.2]
1449
[57.0]
OVERALL
HEIGHT
888 [35.0]
OVERALL WIDTH
758 [29.8]
DOOR TYP
173 [6.8]
618 [24.3]
998 [39.3]
CENTER OF GRAVITY
SEE NOTE 5
1625 [64.0]
343
[13.5]
TITLE
INSTALL CPL PROT D3.4L EXT
ISSUE DATE:
SIZE CAGE NO DWG NO
0K6968
REV
B
A
SCALE
0.050
WT-KG SEE ABOVESHEET
1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2
REV
A
WINDCHILL VERSION
A.1
SERVICE ITEM 3.4L
OIL FILL CAP RIGHT SIDE
OIL DIP STICK RIGHT SIDE
OIL FILTER RIGHT SIDE
OIL DRAIN HOSE RIGHT SIDE
RADIATOR DRAIN HOSE LEFT SIDE
AIR CLEANER ELEMENT RIGHT SIDE
MUFFLER FRONT
FAN BELT EITHER SIDE
BATTERY LEFT SIDE
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN (STEEL ENCL)
997 [2197]
WITH WOODEN SHIPPING SKID
1042 [2297]
REFERENCE OWNERS MANUAL FOR PERIODIC
REPLACEMENT PART LISTINGS.
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2718
(107") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSRE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O.
9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
RIGHT SIDE VIEW
REAR VIEW
LEFT SIDE VIEW
RADIATOR/EXHAUST
DISCHARGE AIR
LIFT-OFF DOOR PROVIDES ACCESS TO:
FUEL FILL, FUEL LEVEL GAUGE,
NORMAL VENT, INNER TANK
EMERGENCY VENT, OUTER TANK
EMERGENCY VENT, OPTIONAL
90% ALARM ASSEMBLY,
OPTIONAL 5 GALLON SPILL
BOX
OPEN PUNCHED LOUVERS TYPICAL
ON BOTH SIDES OF
FUEL TANK VENTILATION
DUCT TO PROVIDE ADEQUATE
CROSS-FLOW OF AIR VENTILATION
EXHAUST MUFFLER ENCLOSED WITHIN
GENERATOR ENCLOSURE
REAR TANK COVER
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL PANEL
ACCESS, BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
REAR ENCLOSURE COVER
PANEL
SEE NOTE 4
FUEL TANK
VENTILATION DUCT
LIFTING PROVISIONS (4 PLACES)
SEE NOTES 5, 9, AND CENTER
OF GRAVITY DIMENSIONS
VICE ACTION LATCH,
ONE PER DOOR, LIFT-OFF
DOORS ON FRONT, RIGHT, AND LEFT SIDES
TOP VIEW
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
INTERNAL DIVIDER PANEL
SEPARATES FUEL TANK VENTILATION
DUCT FROM THE ENGINE,
ALTERNATOR AND EXHAUST SYSTEM
REMOVE PANEL TO
ALLOW TANK VENTS
TO TERMINATE OUTSIDE
OF THE GENERATOR
ENCLOSURE (CHECK LOCAL
AND STATE CODE FOR
APPLICABILITY)
4 3 2 1
4 3 1
A
B
A
B
660 [26.0]
101 [4.0]
351 [13.8]
2226 [87.6]
121 [4.8]
196 [7.7]
STUB-UP
AREA
786 [30.9]
STUB-UP
AREA
51
[2.0]
38
[1.5]
125
[4.9]
110 [4.3] TYP
690 [27.2] TYP
1216 [47.9] TYP
1769 [69.6] TYP
2322 [91.4] TYP
394 [15.5]
888 [35.0]
19
[.7]
851 [33.5] TYP
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL CPL PROT D3.4L EXT
ISSUE DATE:
SIZE CAGE NO DWG NO
0K6968
REV
B
A
SCALE
0.075
WT-KG SEE ABOVESHEET
2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2
REV
A
WINDCHILL VERSION
A.1
FUEL TANK
TOTAL CAPACITY 233 [61]
USABLE CAPACITY 209 [55]
DIMENSIONS:
CAPACITY:
LITER [GALLONS]
MM [INCH]
THIS TANK IS LISTED TO UL142 AND ULC/ORD C142.18
REMOVABLE
STUB-UP COVER
OUTER TANK EMERGENCY VENT
(2" NPT FEMALE)
INNER TANK NORMAL VENT
(2" NPT FEMALE)
INNER TANK EMERGENCY VENT
(2" NPT FEMALE)
FUEL LEVEL
GAUGE/SENDER
FUEL FILL
(2" NPT FEMALE)
FUEL RETURN
FUEL SUPPLY
CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER
CONNECTION OPENING
HIGH AND LOW VOLTAGE
STUB-UP AREA
OUTER TANK LEAK DETECTOR
CUSTOMER OPTION
(2" FEMALE NPT)
16.7 [.66] MOUNTING HOLES
(10 PLACES)
/