Jade JCR-1 User manual

  • Hello! I am an AI chatbot trained to assist you with the Jade JCR-1 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
WWW.JADERANGE.COM
CHINESE RANGE
TITAN CHINESE RANGE
MODEL NO. DESCRIPTION
o
jcr-1 one hole chinese range
o
jcr-2 two hole chinese range
o
jcr-3 three hole chinese range
o
jcr-4 four hole chinese range
o
jcr-5 five hole chinese range
o
jcr-6 six hole chinese range
STANDARD FEATURES
Heavy gauge stainless steel front, sides, interior angle
structuring, plate shelf, top, sides & pipe legs
Range top 12 gauge stainless steel angle iron and reinforced
with 10 gauge steel burner chamber
Heavy gauge steel body structure
Each burner individually controlled—each hole has individual
main “shut-offvalve
Heavy-duty stainless steel pipe legs with adjustable feet for
leveling
Stainless steel tubular rack provided for holding wok covers
Top-cooling water flow is controlled by independent valve—
water flows through perforated stainless steel tube running
the length of the appliance, beneath 14 gauge stainless steel
front plate shelf
Gas inlet and water drain location are available (by
specification) at either end on rear of appliance
Appropriate size wok, cover and drip pan for each hole
Stainless steel drip pan for each hole
One faucet kit for every two holes
Spice tray
1-1/4" gas regulator
form #jt0550 ©2008 jade range, llc
JCR-4 (four 20
" holes)
TM
®
TITAN
DRAIN PIPE 2"
(SPECIFY LEFT OR RIGHT)
1 1/4" GAS
DRIP PANS
1/2" WATER
CONN.
40" [1016]
10 1/2" [267]
20" [508]
30 1/2" [775]
62 3/4" [1594]
1 1/2" [38]
10" [254]
2" [51]
2 1/2" [64]
16" [406]
14 3/4" [375]
4 1/2" [114]
30" [762]
3" [76]
24" [610]
LENGTH
CONNECTION
(SPECIFY LEFT OR RIGHT)
CUSTOM CHINESE RANGE FORMULA
To calculate width of range, add 1" to each hole plus width of hole; add
4" for each side; add 6" between each hole.
Example: For JCR-2 (one 14" hole and one 16" hole), calculate
4 + (14 + 1) + 6 + (16 + 1) + 4 = 46" overall width
PLEASE SPECIFY WHEN ORDERING
Hole Size(s)
3-ring o or Jet Burners o
Gas Inlet: Right o Left o
Water Drain: Right o Left o
Manual o or Swing on Faucet o
Ring burners or jet burners to 100,000 BTU/hr. each
H
H
Standard hole diameters are: 12", 14", 16", 18", 20", 22" & 24".
Depth is 42" when 24" hole is specified.
JADE RANGE, LLC., A MIDDLEBY COMPANY • 2650 Orbiter Street • Brea, CA 92821 • PHONE: 800-884-5233 FAX: 714-961-2550
Note: In line with their policy to continually improve products, Jade reserves the right to change materials and specifications without notice. printed in usa
/