Installation
10 3A4676H
Choosing an Installation
Location
• Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
• Refer to the mounting hole layouts provided in
the Mounting Pattern section of this manual,
page 45. No other installation configuration
should be used.
• Use designated mounting holes and provided
configurations only.
• Use the three fasteners (included) to secure the
G3 to the mounting surface.
• Some installations may require an additional
reservoir support bracket. See Table below for
bracket information
• In high vibration environments, additional isola-
tion at mounting point is necessary.
• AC pumps are not recommended when high
vibration or shock is present.
System Configuration and
Wiring
Grounding
If the product is permanently connected:
• it must be installed by a qualified electrician or ser-
viceman.
• it must be connected to a grounded, permanent
wiring system.
If an attachment plug is required in the end use
application:
• it must be rated for the product electrical specifica-
tions.
• it must be an approved, 3-wire grounding type
attachment plug.
• it must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
• when repair or replacement of the power cord or
plug is required, do not connect the grounding wire
to either flat blade terminal.
AUTOMATIC SYSTEM ACTIVATION HAZARD
The G3 system is equipped with an automatic timer
that activates the pump lubrication system. Unex-
pected activation of the system could occur and
result in serious injury, including skin injection and
amputation.
Before you install or remove the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
Part No Description
571159 Reservoir bracket and strap
125910 L-Bracket for pump
127665 USP to G-Series mounting bracket
132187 Isolator mounting kit
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or
static sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Improper installation of the grounding conductor
may result in a risk of electric shock. This product
must be installed by a qualified electrician in compli-
ance with all state and local codes and regulations.