JENN-AIR
®
DETAILED PLANNING DIMENSIONS
4 of 4
8613AdZw915
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
OPENING/CLEARANCE DIMENSIONS
e e
B
D
e
e
A
3
4
" (1.9
cm) Side
3
4
" (1.9
cm) Side
2" (5.1 cm)
Top Cleat*
E
C
A
E
B
F
F
ee
ee
E
5
/
8
" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
F
Side Cleat*
1
3
/8" (3.5 cm)
Side Cleat*
E
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
1
1
2
" (3.8 cm)
Platform*
D
C
11
/16" (1.7 cm)
Side Cleat*
Power Supply Location
A
B
5
/8" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
A
B
9
/16" (1.4 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
e e
B
D
e
e
A
3
4
" (1.9
cm) Side
3
4
" (1.9
cm) Side
2" (5.1 cm)
Top Cleat*
E
C
A
E
B
F
F
ee
ee
E
5
/8" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
F
Side Cleat*
1
3
/8" (3.5 cm)
Side Cleat*
E
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
1
1
2
" (3.8 cm)
Platform*
D
C
11
/16" (1.7 cm)
Side Cleat*
Power Supply Location
A
B
5
/8" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
A
B
9
/16" (1.4 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
FRONT VIEW SIDE VIEW
27" COMBINATION MICROWAVE/WALL OVEN – FLUSH INSTALLATION
JMW2427D – 27" x 43
3
⁄4" x 24
3
⁄8" (depth without handles)
MODEL # JMW2427D
in cm
A
Width of flush inset cutout
(min.)
27
1
⁄4 69.2
B
Width of opening (min.) 25
7
⁄8 65.7
C
Height of flush inset cutout
(min.)
44
5
⁄16 112.5
D
Height of opening
(recommended)
43
11
⁄16 110.9
E
Bottom of cutout to floor
4
5
⁄8-
19
1
⁄4
11.7-
48.9
F
Depth of cutout (min.) 25 63.5
e
Recommended junction box location
ELECTRICAL REQUIREMENTS
240 volt, 40-amp fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6 cm)
maximum below the support surface. Drill a 1" (2.5 cm) minimum
diameter hole in the right rear or left rear corner of the support
surface for access to the junction box.
FLUSH INSTALLATION REQUIREMENTS
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a
1
⁄4" (0.6 cm) reveal on the top,
a
1
⁄4" (0.6 cm) reveal on the sides and a
1
⁄8" (0.3 cm) reveal on
the bottom of the wall oven.
The front face of the cleats and spacers will be visible and
should be treated as a finished surface.
BACK VIEW
e e
B
D
e
e
A
3
4
" (1.9
cm) Side
3
4
" (1.9
cm) Side
2" (5.1 cm)
Top Cleat*
E
C
A
E
B
F
F
ee
ee
E
5
/8" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
F
Side Cleat*
1
3
/8" (3.5 cm)
Side Cleat*
E
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
1
1
2
" (3.8 cm)
Platform*
D
C
11
/16" (1.7 cm)
Side Cleat*
Power Supply Location
A
B
5
/8" (1.6 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
A
B
9
/16" (1.4 cm)
Top Cleat*
11
/16" (1.7 cm)
Side Cleat*
1
/2" x 2" (1.3 x 5.1 cm)
Spacer (entire depth
of cutout)
D
C
11
/16" (1.7 cm)
Side Cleat*
TOP VIEW
* Cleats and spacers must be recessed 1
3
⁄8" (3.5 cm) from the front of the cabinet.
A
D
G
E
H
B C
F
I
J
K
A
M
N
O
P
L L
C
H
A
B
J
K
F
G
I
Power Supply
Location