Perrot Hydra M W Vac Operating instructions

Type
Operating instructions

This manual is also suitable for

Perrot Hydra M W Vac is a pop-up sprinkler with a part- or full-circle irrigation pattern. It is suitable for both residential and commercial use, and can be used to water lawns, gardens, and other landscaped areas. The sprinkler is made of durable materials and is designed to withstand the elements, making it a reliable choice for outdoor irrigation.

Here are some of the features and benefits of the Perrot Hydra M W Vac:

  • Adjustable irrigation sector: The sprinkler can be set to water a specific sector, from 0 to 360 degrees. This allows you to customize the irrigation pattern to your specific needs.

Perrot Hydra M W Vac is a pop-up sprinkler with a part- or full-circle irrigation pattern. It is suitable for both residential and commercial use, and can be used to water lawns, gardens, and other landscaped areas. The sprinkler is made of durable materials and is designed to withstand the elements, making it a reliable choice for outdoor irrigation.

Here are some of the features and benefits of the Perrot Hydra M W Vac:

  • Adjustable irrigation sector: The sprinkler can be set to water a specific sector, from 0 to 360 degrees. This allows you to customize the irrigation pattern to your specific needs.
TDP062e.doc Rev.02.06.2014 Page1/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
OperatingManual
PopupSprinkler
HydraM(W)VAC
PERROT
TDP062e.doc Rev.02.06.2014 Page2/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Contents
1 SAFETY...................................................................................................................................................3
1.1 HOWINSTRUCTIONSAREMARKEDINTHISMANUAL.............................................................................................3
1.2 HAZARDSOFIGNORINGSAFETYINSTRUCTIONS...................................................................................................3
2 DESCRIPTION.........................................................................................................................................4
3 INSTALLATION.......................................................................................................................................5
4 SPECIALTOOLS.......................................................................................................................................5
5 COMMISSIONING/PREPARINGFORWINTER.........................................................................................6
5.1 COMMISSIONING.........................................................................................................................................6
5.2 PREPARINGFORWINTER................................................................................................................................7
6 SETTINGIRRIGATIONSECTOR.................................................................................................................7
7 REPLACINGTHENOZZLE.......................................................................................................................10
7.1 ADJUSTINGTHEINLETNOZZLE .......................................................................................................................12
7.2 FITTINGTHESPRINKLERINSERT......................................................................................................................13
8 VALVEINSERTREMOVAL/INSTALLATION............................................................................................14
8.1 TAKINGOUTTHEVALVE...............................................................................................................................14
8.2 TAKINGOUTTHECOARSEFILTERONLYIFSEENTOBEDIRTY..............................................................................15
8.3 FITTINGCOARSEFILTER................................................................................................................................16
8.4 FITTINGTHEVALVE.....................................................................................................................................16
8.5 FITTINGTHESPRINKLERINSERT......................................................................................................................17
9 CONTROLUNITREMOVAL/INSTALLATION..........................................................................................18
9.1 TAKINGOUTTHECONTROLUNIT....................................................................................................................18
9.2 FITTINGTHECONTROLUNIT..........................................................................................................................19
10 REMOVAL/FITTINGOFMANUALOPENINGANDPRESSUREREGULATINGINSERTS...........................19
10.1 REMOVALOFMANUALOPENINGANDPRESSUREREGULATINGINSERTS..................................................................19
10.2 FITTINGMANUALOPENINGANDPRESSUREREGULATINGINSERTS.........................................................................20
11 MAINTENANCE.................................................................................................................................20
12 TROUBLESHOOTING.........................................................................................................................21
12.1 MALFUNCTIONS.........................................................................................................................................21
TDP062e.doc Rev.02.06.2014 Page3/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
1 Safety
Thisoperating&safetymanualcontainsfundamentaladvicetobeheededduring
installationandoperation.Itisthereforeimperativethatthefitterandrelevant
engineer/operatorreadthismanualthoroughlypriortocommissioningandoperation.
Pleasefollowboththegeneralsafetyinstructions specifiedinthis‘safety’sectionandthe
specificsafetywarningsincludedinothersections.
1.1 Howinstructionsaremarkedinthismanual
Safetyinstructionsthat,ifignored,could endanger human life or limbaremarkedwiththe
general"danger"symbol:
"Warning"isprintednexttoinstructionsthat,ifignored,couldbehazardoustothesprinkler
anditsoperation.

1.2 Hazardsofignoringsafetyinstructions
Failing to heed the safety instructions may result in danger to life and limb, harm to the
environmentand/ordamagetothedevice.Failingtoheedthesafetyinstructionsmaylead
tothelossofanyrighttoclaim
compensation.
TDP062e.doc Rev.02.06.2014 Page4/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
2 Description
Viewfromabove
Leftstop
position
adjuster
screw
Rightstop
position
adjuster
screw
Plugfordecoder
control
Directionof
nozzleopening
Pressure
regulatorscrew
Manualopening
Housingcover
Guidehousing
Protectivehousing
S
idevie
w
Guidegrooveforlid
dismantling
TDP062e.doc Rev.02.06.2014 Page5/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
3 Installation
Thoroughlyflushthepipelinebeforeinstallingthesprinkler
SealconnectingthreadwithTeflontape.
Note: Partcirclesprinklersmustbesetupinsuchawaythatthe mark
 isalignedinastraightlinefromtheleftsideoftheirrigationsector.
4 Specialtools
KeyforcoarsefilterHydraM+S Disassemblyofcoarsefilter
RT14930
Retainerforsprinklerhead
HydraL/M/S
Changingnozzle
RT14031
FlushingequipmentHydraM Flushingpipes
RT14934
Wrenchforchangingnozzles Changingnozzles
ZB98276
Retainingringlifter Disassemblyofvalve
RT17839
Retainingringcollet Assemblyofvalve
RT17844
Alignment
Leftsideofirrigationsector
TDP062e.doc Rev.02.06.2014 Page6/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
5 Commissioning/Preparingforwinter
5.1 Commissioning
a) Checkelectricalfunction:
Beforeopeningwatersupplytothesprinkler,activatecoilviathecontrolmodule.
Thesoundofa‘click’onthecoilletsyoudetermineifthesprinkler’selectrical
functionisworkingcorrectly(theclickiscausedbytherotorbeingactivated).
b) Makesurethat‘Manualopening’issettoAUTO(turnscrewfor‘Manualopening’
roundtotheleftasfarasitwillgo).
Onthissetting,wheneveritisnotswitchedonthesprinklerisguaranteedtoclose
followingthesupplyofwater.
c) Slowlyopenwatersupplytothevalveuntiloperatingpressureispresent.The
sprinklermaybrieflyopenbutshouldthencloseautomaticallyafternomorethan30
seconds.
d) Oncethewatersupplyisopenandthemaximumoperatingpressurehasbeen
reached,checksprinklerandconnectionforleaks.
e) Checksprinklerisworkingflawlessly:
Opensprinklerusing‘Manualopening’byturningthescrewfor‘Manualopening’to
thepositionbetweenAUTOandOFF(approx.1revolution).Sprinklerheadrisesand
beginstorotate.
  Donotstandfacingthenozzleopening!
Setdesiredoutputpressurebyturningthe‘Pressureregulatorscrew’totheright()
asfarasitwillgo(minimumpressure).Theoutputpressureisnowsetto
approximately3bar.Ifyouturnthe‘Pressureregulatorscrew’onecomplete
revolutiontotheleft(+),theoutputpressurewillgoupby1bar.
f) Close‘Manualopening’andputintheAUTOposition(seepoint5b).
Sprinklershouldstopthethroughflowofwaterwithin30seconds.
g) Performstepse)andf)againrepeatedlyuntilthisfunctionsareflawlessly.
h) Checkagainthatthesprinklerisworkingcorrectlybystartingitelectricallyfromthe
controlmodule.
TDP062e.doc Rev.02.06.2014 Page7/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
5.2 Preparingforwinter
Beforetheonsetofanywinterfrosts,thesprinklerneedstobeemptied.Todothis,a
powerfulcompressorneedstobeattachedtothepipelinenetwork.Thenopenthe
valveonthesprinklerandkeepitopensuntilnothingbutaircomesoutofthenozzle.
Electricallyactivatethesolenoidseveraltimessothatanyresidualwaterispushed
outofthecoilcavity.
Duringwintertimeitisrecommendedtoactivatethesolenoidforabout1minute2
timesperweek.
Thismodeldoesnothaveadischargevalveandcantherefore
notbe
emptiedthetraditionalwaybygravity.
6 Settingirrigationsector
(Partcirclesprinklersonly)
Settheleftsidestoppositionusing:
Leftstoppositioncanbeadjustedby+/‐90°

Note:
Onecompleterevolutionofthe
adjusterscrewadjuststhesector
stoppositionby60°
TDP062e.doc Rev.02.06.2014 Page8/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Setrightsidestoppositionusing:
Rightstoppositioncan
besettoawateringsectorof30°to330°.

Note: Thesprinklerhasafactorysettingof180°
TDP062e.doc Rev.02.06.2014 Page9/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Note: Inordertospeedupthesettingoftheirrigationsector,thesprinklerheadcan
bemanuallyturnedforwardwiththerotatingdirection..
DONOTTURNBACK!

Rightstop
position
thefactorysettingof
therightsectorstopis
accordingthissketch
Leftstopposition
TDP062e.doc Rev.02.06.2014 Page10/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
7 Replacingthenozzle
Ensuresprinklerisnotunderpressure.
Usingabigscrewdriver,unclipthelid
Usingascrewdriver,removewhiteretainingring.
 
Pullsprinklerinsertoutofthehousing
Pushdowntheflangeandsecuretheheadwiththeretainer

Retainingring
Retainingring
Guidegroovefor
liddismantling
TDP062e.doc Rev.02.06.2014 Page11/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Takeoffsprinklerheadcoverbyleveringthecoverupatthenotchusingasmall
screwdriver.
Rotatenozzletotheleftusingpliersandthenpullout.
Optionallythesprinklercanbeassembledwithatailnozzle.Thisnozzlecanbe
refittedor/andalsoclosedwithacorrespondingplug.
PutOringoverthenewnozzle

and,reversingtheprocedure,reinstallinthesprinklerhead.
Fitcoverintosprinklerhead’ssnapinconnectionbyfirstpushingitasfarasitwillgo
againstthesideoppositethenozzleandthensnappingitcompletelyintoplaceon
thenozzleside.

ORing
Nozzle
TDP062e.doc Rev.02.06.2014 Page12/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
7.1 Adjustingtheinletnozzle
Therecommendedrotationalspeedismaintainedbycorrectlyadjustingtheinletnozzle.
Adjustasfollows:
Takeoffinletnozzleandfiltertogetherbyusingascrewdrivertoleveruptheinlet
nozzleatthenotch.
Snapinletnozzlebackontothesprinklermodulesothattheelongatedribispointing
tothenozzlediameterbeingused.


Note: Ifyouwantahigherrotationalspeed,theribmustbepointingtoasmaller
diameterthanthatofthenozzleactuallybeingused.
View
f
romabove
Inletnozzle
Turbine
Sprinkler
insert
Rib
Rib
Strainer
Inletnozzle
White
forHydraXS4
Black
forHydraS+HydraXS
5+
6
Red forHydraM
TDP062e.doc Rev.02.06.2014 Page13/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
7.2 Fittingthesprinklerinsert
FitOringontoflangeandlightlygreaseforeasierassembly.
Fitsprinklermoduleinsidehousing.
Ensurecorrectalignment.


 
Pushflangedownasfarasitwillgo.
Fitretainingring.
Retainingringmustbefullyinsertedintotheslot.
Unclipsnapfitlidfromthehousing.
Checksprinklerisworkingproperlyasperpoint’s5b5f.
Guideribs
Guidehousing
Sprinkler
insert
TDP062e.doc Rev.02.06.2014 Page14/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
8 Valveinsertremoval/installation
Ensuresprinklerisnotunderpressure.
Usingabigscrewdriver,unclipthelid
Usingascrewdriver,removewhiteretainingring
Pullsprinklerinsertoutofthehousing
8.1 Takingoutthevalve
Takeoffretainingringbyhelpofretainingringlifter(seechapter4).
Screwvalvelifter/coarsefilterwrenchontovalveinsert’sstudsandmanually
tighten.
Pulloutvalveinsertcompletewithvalvelifterandunscrew.Valveinsertisnowheld
onhollowscrewbyOringonly.
Retainingring
Hollowscrew
Retainingring
TDP062e.doc Rev.02.06.2014 Page15/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
8.2 Takingoutthecoarsefilteronlyifseentobedirty
Insertvalvelifter/coarsefilterwrenchintothefilter’sslots,turnandpullout.
Insertflushingequipmentandfixwithretainingring.
Flushsprinkler/pipesthoroughly
TDP062e.doc Rev.02.06.2014 Page16/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
8.3 Fittingcoarsefilter
Takeoffflushingequipment.
EnsurethatthreadandOringareclean.
LightlysmearOringwithacidfreegrease.
Putcoarsefilterinplaceandmanuallytightenusingcoarsefilterwrench.
8.4 Fittingthevalve
Beforefittingthevalve,checkthevalveinsertespeciallyaroundthevalve
seatforanydirtordamage!
Screwcleanedornewvalveinsertontothevalvelifteragainandfitintothesprinkler
housing.
Ensureitisfittedinthecorrectposition!


Hollowscrew Entryfor
hollowscrew
TDP062e.doc Rev.02.06.2014 Page17/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Insertretainingringbyhelpofretainingringcollet(seechapter4).
Retainingringmustbefullyinsertedintotheslots!


8.5 Fittingthesprinklerinsert
FitOringontoflangeandlightlygreaseforeasierassembly.
Installsprinklerinsertinsidehousing.
Ensureitisfittedcorrectlyaligned!
 
Guiderib
Guidehousing
Sprinkler
insert
Retainingring
TDP062e.doc Rev.02.06.2014 Page18/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
Pushflangedownasfarasitwillgo.
Fitretainingring.
Retainingringmustbefullyinsertedintotheslot.
Clipinsnapfitlid.
Checksprinklerisworkingproperlyasperpoints5b‐5e.
9 Controlunitremoval/installation
Ensuresprinklerisnotunderpressure.
9.1 Takingoutthecontrolunit
Usingabigscrewdriver,unclipthelid
Unclipcontrolunitfromprotectivecasingandliftup.
Twistoutcoil.
Whenreplacingthecontrolunit,cutoffthehosesascloseaspossibletotheunit’s
nozzle.
Controlunit
Sprinkler
TDP062e.doc Rev.02.06.2014 Page19/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
9.2 Fittingthecontrolunit
Whenbuyingareplacement,thecontrolunitissuppliedwithplugandsocket
connections.Pushhosesintopluginnozzlesasfarastheywillgoandensurethatthe
mountingringspringsback.
Pleaseensurethatthehosesarefittedinthecorrectposition.Otherwise
thesprinklerwillnotwork.
Screwincoil.
Clipcontrolunitintoprotectivecasing.
Usingabigscrewdriver,clipoffthesnapfitlid.
Checksprinklerisworkingproperlyasperpoints5b5f.
10 Removal/fittingofmanualopeningand
pressureregulatinginserts
Ensuresprinklerisnotunderpressure.
10.1 Removalofmanualopeningandpressureregulatinginserts
Usingabigscrewdriver,unclipthesnapfitlidfromthehousing.
Unclipcontrolunitfromprotectivecasingandliftup.
UsinganSW19flatspanner,twistout
manualopeningandpressureregulator
screws.
Coil
Controlunit
TDP062e.doc Rev.02.06.2014 Page20/21
PerrotREGNERBAUCALWGmbHIndustriestraße1929/D75382Althengstett/Germany
Phone:004970511620/Fax:00497051162–133
Email: [email protected]/EmailTechnicalDepartment:[email protected]
10.2 Fittingmanualopeningandpressureregulatinginserts
SetmanualopeningtoAutoandpressureregulatorintotheminus()position(turn
totheleftasfarasitwillgo)andscrewinusinganSW19flatspanner.
Clipcontrolunitintoprotectivecasing.
Unclipthesnapfitlidfromthehousing.
Checksprinklerisworkingproperlyasperpoints5b5f.
Setmanualopening/pressureregulatorscrewstodesiredposition.
11 Maintenance
Cutsprinklerhousingfreeofanyovergrowinggrass.Itmakessensetodothiswork
withthecutofftoolbeforestartingupthesysteminspring.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Perrot Hydra M W Vac Operating instructions

Type
Operating instructions
This manual is also suitable for

Perrot Hydra M W Vac is a pop-up sprinkler with a part- or full-circle irrigation pattern. It is suitable for both residential and commercial use, and can be used to water lawns, gardens, and other landscaped areas. The sprinkler is made of durable materials and is designed to withstand the elements, making it a reliable choice for outdoor irrigation.

Here are some of the features and benefits of the Perrot Hydra M W Vac:

  • Adjustable irrigation sector: The sprinkler can be set to water a specific sector, from 0 to 360 degrees. This allows you to customize the irrigation pattern to your specific needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI