STIEBEL ELTRON RTF-Z Operation Instruction

Type
Operation Instruction

STIEBEL ELTRON RTF-Z is a digital controller that enables individual control of heating mats with four operating programs: frost protection, off-peak temperature, comfort temperature, and timer program. It features a self-learning function that automatically sets the start time in the timer program to achieve the desired comfort temperature. The timer program allows for up to three time segments per day, with switching times that can be individually set.

STIEBEL ELTRON RTF-Z is a digital controller that enables individual control of heating mats with four operating programs: frost protection, off-peak temperature, comfort temperature, and timer program. It features a self-learning function that automatically sets the start time in the timer program to achieve the desired comfort temperature. The timer program allows for up to three time segments per day, with switching times that can be individually set.

M
+
OK
6
93 15 21
S1
Mo - Fr
Sa - Su
S1
E1
E1
S2
S3
E2
E3
E1
E2
S1
S2
P1
P2
P3
12 18 24
time
comfort temperature
otherwise Off-peak temperature
programs
6
00
6
00
12
00
9
00
9
00
14
00
16
00
17
00
23
00
23
00
23
00
7
00
1 2 3 4 5 6
6 12 18 24
0
7
P
2
S
1
P
2
.
5
1. Operating instructions for the user and the qualified installer
The installation and use of electrical appliances
must be carried out with due caution in
order to avoid the risk of fire, electric shock
or injury. The equipment must only be used as
described in these instructions. Any use out-
side of the manufacturer recommendations
could lead to damage, fire, shock or injury.
Before using the appliance the instructions
should be read in their entirety and all
appropriate handling of the equipment must
be observed.
These instructions should be kept
safely and passed on to any future
owner.
In the event of any repair work, hand them
to the qualified installer for his attention.
Unit description
The RTF-Z digital controller enables individu-
al control of the heating mats. There are four
operating programmes.
When connected to the mains electrical supply
the controller switches on and regulates the
floor heating to a preset temperature. The
„heating operating symbol “ is displayed.
After setting the time the controller auto-
matically switches to the timer programme.
By means of the self learning function of the
RTF Z, the start-time will be set directly into
the timer-program, from which the comfort
temperature will be achieved. Due to this, the
start of the heating-time will be before the
adjusted starting time.
The self-learning-function is activated by the
factory, if wished it can be deactivated within
the adjustment mode.
Switching ON & OFF
To switch off, press the
M button and hold
for 3 seconds, the display will then show OFF.
1 Mode - select an operating mode or
function by repeated pressing
2 Reset - restore the factory setting.
Briefly depress the flush-fitting push-
button with a non-conductive blunt object.
3 Increase the set value
4 Decrease the set value
5 Confirm the set value
6 Display
1 2 3 4 5 6
8966.02
8967.01
Functions
Heating operating
Time
P
Program selection
Timer programs
P1 = Program 1
P2 = Program 2
P3 = Program 3
Operating modes
7 Frost protection
Off-peak temperature
Comfort temperaure
Timer program
Days of the week
1-5 = Monday - Friday
6+7 = Saturday + Sunday
Start / end time in the timer program
S1 = 1st start time E1 = 1st end time
S2 = 2nd start time E2 = 2nd end time
S3 = 3rd start time E3 = 3rd end time
Value indicator
Setpoint floor temperature
(Guide figure, e.g. 2.5 = approx.
25 °C) or time
Time segments of timer
Comfort temperature
Off-peak temperature
Factory settings
Timer program switching times
Floor temperatures of operating modes
Frost protection 1.0
=
^ approx. 10
Guide figure °C
Off-peak temperature 1.8
=
^ approx. 18
Comfort temperature 2.5
=
^ approx. 25
Temperature setting limits
Max. Floor temperature 4.0
=
^ approx. 40
Min. Floor temperature 1.0
=
^ approx. 10
Displays
RTF-Z
Controller for Under-floor Heating Systems
Operation and installation instructions
185582
5 21 225 01
To switch on again press and hold the
M
button for 3 seconds. The controller will
switch on again to its most recent setting.
In the off position frost protection is
not provided.
Safety instructions
Do not operate the appliance
in rooms which present fire or explosion
risks as a result of chemicals, dust, gases
or fumes;
in the immediate vicinity of pipes or
containers which- carry or contain
combustible or potentially explosive
substances.
If a part of the appliance is damaged or has
fallen down or it was already defect/
malfanctioning, it may no be taken in to
operation.
287798
2
1.3 Operating modes
1.4 Changing the timer program
To call up the desired operating mode, press push-button M until the respective symbol appears in the display.
The switching times of the timer program can be adapted to the prevailing wishes of the user.
Allocating the daily program
A program must be allocated to each day of
the week, there is no day which doesn’t have
a program allocation. To remove a day from a
program, the day in question must be
allocated to another program.
Press push-button
M until the
P
, Pr 1
(Program 1) symbol and the days
allocated to the program are displayed;
1
6 12 18 24
0
P
2 3 4 5
Switch between the programs (Pr 2, Pr 3,
Pr 1, . . .) using the
+ push-button;
6
6 12 18 24
0
7
P
Press the
push-button, to display the days
not allocated to the selected program, in
flashing mode;
1
6 12 18 24
0
P
2 3 4 5 6
Press the OK push-button to add the
selected day to the selected program, or
switch to the next as yet unallocated day
using the
push-button;
Repeat steps as described, until all days
have been allocated as desired;
Press push-button
M to terminate the
process – the display changes to the frost
protection symbol.
Program switching times
Press push-button M until the symbol
is displayed;
1.3.1 Frost protection 7
Non-changeable setpoint value (dispaly 1.0),
which is activated at a floor temperature of
approx. 10 °C. All displays except the frost
protection symbol are extinguished after
approx. 20 seconds.
1
6 12 18 24
0
1.3.2 Off-peak temperature
Reduced value in comparison to the comfort
temperature, e. g. during the night-time hours.
1
6 12 18 24
0
1
.
8
Press the + or
push-button to change
the setpoint value. Confirm by pressing the
OK push-button, otherwise the previously
set value will be restored after 20 seconds.
1.3.3 Comfort temperature
Here, the preferred floor temperature during
the main period of use is set. In this
operating mode, the thermostat maintains
the set value by intermittent operation of the
floor temperature heating.
1
6 12 18 24
0
2
.
5
Press the
+ or
push-button to change
the setpoint value. Confirm by pressing the
OK push-button, otherwise the previously
set value will be restored after 20 seconds.
1.3.4 Timer program
With the built-in timer, each weekday is
allocated to a time program for automatic
changeover between comfort and off-peak
temperature. Three time programs are
available with a specified number of switching
operations during the day, the switching times
of which can be individually set:
Program 1 (P1): 2 switching operations
Program 2 (P2): 1 switching operation
Program 3 (P3): 3 switching operations
The following switching times are set at the
factory for each week (changing between
comfort and off-peak temperature):
6
3 9 15 21
Mo
P 1
S1 E1 S2 E2
S1 E1 S2 E2
S1 E1 S2 E2
S1 E1 S2 E2
S1 E1 S2 E2
E1
E1
S1
S1
P 2
We
Fr
1
3
5
Tu
Th
Sa
Su
2
4
6
7
12 18 24
time
Comfort temperature
day of the week
6
00
7
00
23
00
9
00
16
00
23
00
or
1.1 First start-up
After connecting to the mains supply, the following displays appear:
for approx. 5 seconds . . . . . . then alternately probe defective or not connected
1.2 First-setting the time and day of the week
Press push-buttom
M until the function symbol is displayed.
Hour Push-
button
+
or
Minutes
Push-
button
Day of the week
+
or
Push-
button
OK OK
OK
+
or
6 12 18 24
0
2
.
5
6 12 18 24
0
00
:
00
1 2 3 4 5 6
6 12 18 24
0
7
8
8
8
8
P
88
:
88
00
:
00
00
:
00
1
After selecting the timer program, the
thermostat automatically switches to the
program set on the current day of the week.
1
6 12 18 24
0
P
1
S
1
2
.
5
Party function
Short-term change to the setpoint tempera-
ture within the timer program up until the
next switching time.
1
6 12 18 24
0
P
1
1
.
8
Press
+
or
push-button to make a
short-term temperature change;
1
6 12 18 24
0
P
1
2
.
2
Press OK push-button to confirm. The timer
switching program now adopts the change
temperature until the next switching time.
Sensor short-circuit
3
Select the frost protection 7 operating
mode;
1
6 12 18 24
0
Simultaneously press M and OK for 3
seconds, until „Just“ is displayed;
Display setting
Press the + or
push-button to select
the type of display
S = setpoint value
U = time
SuU = setpoint value and time
alternating every 5 seconds;
Press the OK push-button to confirm and
switch to the next adjustment setting.
Maximum floor temperature
40 °c
Press the + or
push-button to set the
maximum adjustable floor temperature;
Press the OK push-button to confirm and
switch to the next adjsutment setting.
Minimum floor temperature
Press the + or
push-button to set the
minimum adjustable floor temperature
(difference between the minimum and
maximum floor temperatures at least
5 °C, if this figure is fallen short of the
maximum value is automatically adjusted);
The minimum floor temperature
does not have any affect on the
„Frost protection“ operating mode.
Press the OK push-button to confirm and
switch to the next adjsutment setting.
Self learning function
If the self learning function is activated, the
RTF-Z switches the floor heating
automatically on in such a manner so that a
moderate comfortable temperature is
reached already at the adjusted starting
times.
Press push-button + or
, in order to
activate the self learning function (Indication
„1“) or deactivate (Indication „0“).
If the self learning function is deactivated,
the adjusted starting times in the clock
program mean the beginning of the
heating time;
Press the OK push-button to return to
the display setting or press push-button
M to terminate the adjustment mode.
1.5 Adjustment (can only be set in frost protection mode)
Individual settings of operating parameters, which remain stored even in the event of a power failure.
1
6 12 18 24
0
P
1
S
1
2
.
5
Press the OK push-button to switch to
the programming mode, and select the
switching program to the changed using
the
+ or
push-button;
6 12 18 24
0
Press the OK push-button to switch to
the 1st start time (S1) of the selected
program;
6 12 18 24
0
P
1
S
1
06
.
00
Press the + or
push-button to set the
start time (15 minute steps);
Press the OK push-button to switch to the
1st end time (E1) of the selected program;
6 12 18 24
0
P
1
E
1
09
.
00
Press the + or
push-button to set the
end time (15 minute steps);
Press the OK push-button to switch to
the 2nd start time (S2) of the selected
program;
Repeat steps as described, until all start
and end times have been allocated as
desired,
Press push-button
M to terminate the
setting program and to return to the
timer program.
1.6 Change of settings the time and day of the week, while unit is active
Press push-buttom M until the function symbol is displayed.
Hour
+ or
Minutes Push-
button
Day of the week
+ or
Push-
button
OK OK OK
+ or
08
:
43
43
:
08
1
2. Installation instructions for the qualified installer
The installation (electrical work) and
commissioning as well as maintenance of this
appliance must be carried out only by an
approved qualified installer in accordance
with these instructions.
Only remove the packaging at the place of
installation and take care to ensure that no
accessories remain behind in the packaging
material.
2.1 Instructions and
regulations
The appliance must not:
Be operated in areas which are subject
to the risk of fire or explosion due to
chemicals, dust, gases or vapours;
Be operated in the immediate vicinity of
pipes or containers which carry or
contain combustible or potentially explo-
sive substances.
All electrical connection and installation work
must be carried out in accordance with the
VDE regulations (0100), the regulations of
the competent water and electricity supply
companies as well as the appropriate national
and regional regulations.
Follow the data printed on the bottom of
the controller. The stated voltage must be in
accordance with the mains voltage.
If the heating unit is installed in rooms with
a bath and/or a shower, the range of
protection according to the I.E.E. Regulati-
+ or
Push-
button
Push-
button
M
+
OK
8968.01
28,5
81,5
85
44,5
8970.02
7
9
8
8969.02
47
F F
LH
L
N
Elektronik
RTF-Z
L
N
FT...
Great Britain
Exclusive Distributor:
Applied Energy Products Ltd.
Morley Way GB-Peterborough PE2 9JJ
CAP 185582/34118/4/8145 · ALRE · These instructions are subject to alteration notice!
ons- in conformity with the information on
the unit rating plate - must be taken into
account.
The unit is to be fitted in such a way that
switching and control devices cannot be
touched by anyone in the bath or under
the shower.
If the sensor probe is damaged, short-
circuited or not connected, the heating
system will be switched off.
2.1 Installing the
temperature probe
Prior to fitting the top covering of the floor, the
temperature probe is to be let into an empty
tube flush with the surface in the foundation
flooring (for example the screed flooring);
see operating and installation instructions for
temperature controlled floor mat.
In the case of a fault live electricity
can be present in the controller or
sensor lead.
2.2 Installing the thermostat
The thermostat is to be inserted into a
standard commercial UP switch box for unit
diameters of 55 mm.
The thermostat is to be inserted as follows:
Pull off the complete changeable frame (7,
8), to do this grasp the switch frame at the
top and bottom;
Carry out the electrical connection in
accordance with the connection diagram
and as follows:
t The sensor probes are connected to
the 2 terminals marked „F“.
t The incoming mains electricity should
be connected as follows:
Live to „L“
Neutral to „N“
Earth to Earth terminal on backbox
t The heating mat/s connections should
be as follows:
Live to „L“
Neutral to „N“
Earth to Earth terminal on backbox
Length of temperature probe (DIN 44574) 4 m
Switching capacity ~ 16(2) A 230 V
Type RTF-Z
Range of adjustment ca. 10 ºC . . . 40 ºC
Protection class ΙΙ, acc. this manual
Switching difference 1 K
H x W x D 85 x 81,5 x 44,5 mm
Protection mode IP 30 (after mounting)
Power reserve 4 days, after 1h of operation
Sensor characteristics value
Temperature R [kOhm] U [V]
20 °C 2,43 2,22
10 °C 3,66 2,49
40 °C 1,15 1,63
30 °C 1,65 1,92
50 °C 0,82 1,35
Approvals see rating plate
4. Guarantee
3. Environment and
recycling
Recycling of obselete appliances
Appliances with this label must not
be disposed off with the general
waste. They must be collected
separately and disposed off according to local
regulations.
For guarantee please refer to the respective
terms and conditions of supply for your
country.
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified installer.
The company does not accept liability for
failure of any goods supplied which are not
installed in accordance with the
manufacturer's instructions.
Insert the thermostat (9) into the switch
box and screw together;
Replace the casing cover (7) and, if
appropriate, the switch frame (8) in addition.
The installation and operating
instructions for the floor heating unit,
to which the room thermostat should be
connected, has to be observed.
2.3 Hand-over
Explain the functions of the appliance to the
user. In particular, draw his or her attention
to the safety instructions. Hand over the
operating and installation instructions.
08709-000420 Fax 01733-319610
E-Mail sales@applied-energy.com
Internet www.applied-energy.com
Great Britain
Stiebel Eltron UK Ltd.
Unit 12 Stadium Court
Stadium Road
Bromborough
Wirral CH62 3QP
Email: info@stiebel-eltron.co.uk
www.stiebel-eltron.co.uk
A 287798-35136-8434
B 185582-35136-8434-M
Great Britain
Stiebel Eltron UK Ltd.
Unit 12 Stadium Court
Stadium Road
Bromborough
Wirral CH62 3QP
www.stiebel-eltron.co.uk
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

STIEBEL ELTRON RTF-Z Operation Instruction

Type
Operation Instruction

STIEBEL ELTRON RTF-Z is a digital controller that enables individual control of heating mats with four operating programs: frost protection, off-peak temperature, comfort temperature, and timer program. It features a self-learning function that automatically sets the start time in the timer program to achieve the desired comfort temperature. The timer program allows for up to three time segments per day, with switching times that can be individually set.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI