Hewlett Packard Enterprise H8B50A Datasheet

Category
Power distribution units (PDUs)
Type
Datasheet

This manual is also suitable for

QuickSpecs
HP Managed Power Distribution Units (maPDU)
Overview
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 1
HP Managed Power Distribution Units (maPDU)
Looking for a power distribution unit that meets the demands of high temperature operating environments and provides
monitoring and switching capabilities?
The HP Managed Power Distribution Unit (maPDU) provides both local and remote power management for your IT racks. An
advanced LCD screen provides local monitoring and alert indications, while remote access and configuration are available through
secure Web, SNMP, CLI, or Telnet interfaces. Remote outlet monitoring offers ±1% billing grade accuracy while remote switching
capabilities support power on/off functionality to remotely reboot equipment or restrict outlet usage. The maPDU features a low-
profile, single-piece design that provides multiple mounting options with ease of access to rear devices for maintenance. It is
compatible with all HP 11000 G2 and Intelligent Series racks, as well as with many non-HP racks using standard button and
keyhole mounting. Multiple options are available supporting vertical/0U configurations with both single and 3-phase models.
Managed PDU, Half Height Model (H8B49A shown)
Managed PDU, Full Height Model (H8B50A & H8B51A shown)
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Overview
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 2
Managed PDU, Full Height Model (H8B53A shown)
Managed PDU, Full Height Model (H8B55A & H8B56A shown)
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Models
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 3
HP Managed Power
Distribution Units
(maPDU)
Half Height Models
HP 3.6kVA 200-240 Volt Detachable C20 Input (7xC13/1xC19) WW Managed PDU
H8B49A
Full Height Models
HP 2.8kVA 120 Volt L5-30 Input (24x NEMA 5-20) NA/JP Managed PDU
H8B48A
HP 4.9kVA 208 Volt L6-30 Input (20xC13/4xC19) NA/JP Managed PDU
H8B50A
HP 7.3kVA 200-240 Volt IEC309 32A Input (20xC13/4xC19) INTL Managed PDU
H8B51A
HP 8.6kVA 208 Volt L15-30 3 Phase Input (18xC13/6xC19) NA/JP Managed PDU
H8B52A
HP 8.6kVA 208 Volt L21-30 3 Phase Input (20xC13/3xC19/1x NEMA 5-20) NA/JP Managed
PDU
H8B53A
HP 11kVA 400 Volt IEC309 16A 3 Phase Input (21xC13/3xC19) INTL Managed PDU
H8B54A
HP 14.4kVA 208V CS8365C 3 Phase Input (12xC13/12xC19) NA/JP Managed PDU
H8B55A
HP 17.3kVA 208V IEC309 48A 3 Phase Input (12xC13/12xC19) NA/JP Managed PDU
H8B56A
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Standard Features
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 4
Key Features
and Benefits
Local and remote power distribution management with billing grade accuracy
An advanced LCD screen on HP Managed Power Distribution Units (maPDU) provides local
monitoring and alert indications.
Remotely access and configure each maPDU through secure Web, SNMP, CLI, or Telnet
Interfaces with the ability to daisy-chain up to four units to share the same network connection
and IP address.
Remote outlet monitoring within ±1% billing grade accuracy.
Remote outlet switching provides power on/off capabilities to remotely reboot equipment or
restrict outlet usage.
Supports both Local and LDAP security with multiple access levels to provide enhanced
security.
Flexible, simple installation and maintenance
The HP Managed Power Distribution Unit features a low-profile, single-piece design supporting
multiple mounting options and ease of access to rear devices for maintenance.
Each maPDU can be installed on either side of the rack with outlets facing the back of the rack
for easy access and improved clearance.
Install maPDU units side by side on both sides of the rack with the outlets facing in towards the
center of the rack for high density configurations.
Provides integrated power cord retention on all IEC receptacles that work with standard power
cords.
Add an optional environmental sensor which can measure air temperature and humidity in the
front or rear of the rack, sending alerts over the network based on user-defined thresholds.
Compatible With a Wide Range of HP and Non-HP Rack Solutions
HP Managed Power Distribution Units are designed to provide complete compatibility with HP
11000 G2 and Intelligent Series racks.
The maPDU is also compatible with a wide range of non-HP racks using standard button and
keyhole mounting.
Designed for vertical/0U rack configurations offering both half and full-height form factors.
Support for a wide range of load capacities, from 2.8kVA to 17.3kVA, with both single and three-
phase models.
Billing Grade
Accuracy
All HP Managed Power Distribution Units (maPDU) meet IEC 62053-21, Class 1 standards for ±1% or
better accuracy in power monitoring of:
Amperage
Voltage
Wattage
Kilowatts per hour
Accurate outlet and load segment power monitoring improves circuit utilization and provide information
that can help balance power throughout the data center to maximize efficiency and cooling.
Remote Access
Support
Easy to use CLI and web interfaces
Local and LDAP security with multiple access levels
HTTP, HTTPS, Telnet/SSH protocols
IPv4 and IPv6 compatible
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Standard Features
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 5
SNMPv1 and SNMPv3 compatible
Email alert notifications
User settable alert thresholds
Event logs
Flexible Installation
The HP Managed Power Distribution Units (maPDU) are available in two form factors supporting a variety
of vertical/0U rack configurations. All HP Managed Power Distribution Units (maPDU) can be mounted to
stay completely out of the critical rear maintenance path needed to service IT equipment in the rack. All
vertical models use industry standard button and keyhole mounting for simple drop in installation in HP
11000 G2 and Intelligent Series racks, as well as many non-HP racks.
Mount vertically on either side in the rear of the rack using industry standard button and keyhole
mounting.
Standard mounting faces the outlet towards the rear of the rack. This configuration fully
prevents interference in the maintenance zone between rear RETMA rails.
Using the optional configuration of facing the outlets into the rack, multiple PDUs can be
mounted on one side of the rack for higher power density.
NOTE: Facing the outlets into the rack will interfere with the lower few rack U spaces of the rear
maintenance zone due to breakers on the PDUs.
maPDU Form Factors
Half Height PDU
o Designed to fit in 22U and taller racks
o Up to 4 Half Height PDUs can be mounted on one side of a 42U or 47U rack using the
optional inward facing configuration.
Full Height PDUs
o Designed for 42U and taller racks.
NOTE: When mounted in the standard rear facing configuration only 1 Full Height PDU can be mounted
per side of the rack. Up to 2 Half Height PDUs can be mounted per side in the standard rear facing
configuration in a 42U or taller rack.
Environmental
monitoring
An optional environmental sensor attaches to the HP Managed Power Distribution Units (maPDU) and can
measure air temperature and humidity in the front or rear of the rack. The environmental sensor will
send alerts over the network based on user defined thresholds.
Warranty
HP Managed Power Distribution Units (maPDU) are backed by a limited 3-year warranty.
HP Managed Power Distribution Units (maPDU) automatically assume the Care Pack coverage level of any
covered ProLiant server in the same rack.
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Service and Support
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 6
HP Care Pack Services
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours,
7 days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response
times range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Related Options
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 7
HP Environmental
Sensor
HP Environmental Sensor for Remote Monitored PDUs
E2D53A
Hot installable and hot swappable
User selectable alarm thresholds
Measure temperature from 32˚F to 158˚F (0˚C to 70˚C) with an accuracy of
±3.6˚F (±2˚C)
Measures relative humidity from 10% to 90% with an accuracy of ±5%
Supports normally open and normally closed contact devices
NOTE: The HP Environmental Sensor comes with a 6 foot RJ45-RJ45 cable and can be
mounted in various locations within the rack using the supplied Velcro strips or
mounting screw. RJ45 cables up to 30 feet (9.1m) long may be used.
NOTE: One environmental sensor may be installed per HP Managed PDU
HP Country specific
C19 PDU Inlet Cords
(required for H8B49A )
HP C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord
AF593A
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord
AF592A
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord
AF584A
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord
AF582A
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord
AF583A
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord
AF577A
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord
AF581A
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord
AF576A
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord
AF580A
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord
AF579A
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord
359615-031
HP 240 VAC 4.5M Unterminated End NA Power Cord
E7806A
NOTE: Please refer to the HP ProLiant Power Cables web page for more information on
power cable/cord part numbers and descriptions.
HP Jumper Cables
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord
A0K03A
HP C13 - C14 WW 250V 10Amp 0.7m Jumper Cord
142257-B28
HP C13 - C14 WW 250V 10Amp 1.4m Jumper Cord
142257-006
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord
A0K04A
HP C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord
142257-007
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord
A0K02A
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord
AF573A
HP C13 - C14 WW 250V 10Amp 2.5m Jumper Cord
142257-002
HP C13 - C14 WW 250V 10Amp 3.0m Jumper Cord
142257-003
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord
A0K06A
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
AF590A
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord
AF575A
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord
AF574A
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord
295633-B22
HP 200-250V 10A C15 to C14 .76m Jumper Cable
E7807A
NOTE: Please refer to the HP ProLiant Power Cables web page for more information on
power cable/cord part numbers and descriptions.
HP Mounting Brackets
HP Vertical PDU 10K G2 Mounting Kit
NOTE: Allows HP Basic and Managed Power Distribution Units (maPDU) vertical models
to be mounted in HP 10000 G2 series racks and in the HP V142 rack. This bracket is not
needed for mounting in the HP 11000G2 or Intelligent Series racks. PDUs may interfere
H6L32A
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Related Options
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 8
with the rear maintenance zone when using these brackets.
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Technical Specifications
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 9
Model Selection Matrix - HP Managed Power Distribution Units (maPDU)
Half Height Vertical Models
Model
Part
Number
Input
Voltage
Current
(Maximum)
Load
Capacity
Input Connection
Output
Circuit
Breaker
Outlet
Connections
3.6kVA PDU
H8B49A
100-240V
16A
3680VA
@ 230V
Detachable cord with
IEC 320-C20 inlet
N/A
7 x IEC C13
1 x IEC C19
NOTE: Model H8B49A includes an IEC320-C20 power inlet and does not include an inlet power cord. Customers may choose
from multiple HP country specific C19 PDU inlet cords that are listed in the “Related Options” section of this quickspec.
Full Height Vertical Models
Model
Part
Number
Input
Voltage
Current
(Maximum)
Load
Capacity
Input Connection
Output
Circuit
Breaker
Outlet
Connections
2.8kVA PDU
H8B48A
100-127V
24A
2880VA
@ 120V
10ft(3m) cord with
NEMA L5-30P
2 x 20A
24 x NEMA 5-20R
4.9kVA PDU
H8B50A
200-240V
24A
4992VA
@ 208V
10ft(3m) cord with
NEMA L6-30P
2 x 20A
20 x IEC C13
4 x IEC C19
7.3kVA PDU
H8B51A
200-240V
32A
7360
@ 230V
10ft(3m) cord with
IEC 60309 32A 3-wire
2 x 16A
20 x IEC C13
4 x IEC C19
8.6kVA PDU
H8B52A
200-240V
3 Phase
Delta
24A
8646VA
@ 208V
10ft(3m) cord with
NEMA L15-30P
3 x 20A
18 x IEC C13
6 x IEC C19
8.6kVA PDU
H8B53A
120/208V
3 Phase WYE
24A
8646VA
@ 208V
10ft(3m) cord with
NEMA L21-30P
3 x 20A
20 x IEC C13
3 x IEC C19
1 x NEMA 5-20R
11kVA PDU
H8B54A
200-240/
346-415V
3 Phase WYE
16A
11040VA
@ 230V
10ft(3m) cord with
IEC 60309 16A 5-wire
N/A
21 x IEC C13
3 x IEC C19
14.4kVA PDU
H8B55A
200-240V
3 Phase
Delta
40A
14410VA
@ 208V
10ft(3m) cord with
CS8365C 50A 4-wire
6 x 20A
12 x IEC C13
12 x IEC C19
17.3kVA PDU
H8B56A
200-240V
3 Phase
Delta
48A
17292VA @
208V
10ft(3m) cord with
IEC 60309 60A 4-wire
Watertight
6 x 20A
12 x IEC C13
12 x IEC C19
NOTE: Please refer to the HP ProLiant Power Cables web page for more information on power cable/cord part numbers and
descriptions.
Disclaimer: HP makes no recommendations regarding power connector manufactures. Please consult a licensed
professional to determine the best connector or receptacle for your specific needs.
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Technical Specifications
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 10
Operational Temperature (NA and NA/JPN models)
32° to 140° F (0° to 60° C)
Operating Temperature (INTL and WW models)
32° to 131° F (0° to 55° C) with an 8A maximum load/outlet
32° to 113° F (0° to 45° C) with outlet fully loaded
Operating Relative Humidity (%)
10% to 90%
Operating Elevation
0 to 10,000 ft (0 to 3048 m)
Storage Temperature
-4° to 140° F (-20° to 60° C)
Storage Relative Humidity (%)
5% to 95%
Storage Elevation
0 to 30,000 ft (0 to 9144 m)
Input Plug Length (attached cord units)
120 inches (304.8 cm)
Conformance Standards
NA/JPN models: UL or CSA, CB Test + FCC, ICES, VCCI
INTL models: CE, TUV, KC, EAC, +KCC, ACMA, Ukraine
WW Models: UL or CSA, CB Test + CE, TUV, EAC, FCC, ICES, KCC, KC, VCCI,
ACMA, Ukraine
Mechanical Dimensions (WxHxD) - Half Height model
(H8B49A)
2.05 x 35.5 x 2.09 in (5.2 x 90.2 x 5.3 cm)
Mechanical Dimensions (WxHxD) - Full Height models
(H8B50A/H8B51A/H8B53A/H8B54A)
2.05 x 66.5 x 2.09 in (5.2 x 168.9 x 5.3 cm)
Mechanical Dimensions (WxHxD) - Full Height models
(H8B48A/H8B52A/H8B55A/H8B56A)
2.05 x 66.5 x 2.56 in (5.2 x 168.9 x 6.5 cm)
Unit Weight
H8B48A: 11.55 lbs (5.24 kg); H8B49A: 4.06 lbs (1.84 kg);
H8B50A: 11.75 lbs (5.33 kg); H8B51A: 10.85 lbs (4.92 kg);
H8B52A: 13.74 lbs (6.23 kg); H8B53A: 13.23 lbs (6.00 kg)
H8B54A: 10.14 lbs (4.60 kg); H8B55A: 21.91 lbs (9.94 kg);
H8B56A: 23.08 lbs (10.47kg)
Kit Contents - All Managed PDUs
All models ship with:
Mounting buttons or hardware
Tie wraps for cable retention
6ft RJ45-RJ45 communications cable
6ft RJ45-DB9 Serial cable
Documentation
Environment-friendly
Products and Approach
End-of-life
Management and
Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and
recycling programs in many geographic areas. For trade-in information,
please go to: http://www.hp.com/go/green. To recycle your product,
please go to: http://www.hp.com/go/green or contact your nearest HP
sales office. Products returned to HP will be recycled, recovered or
disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment
facilities. This information (product disassembly instructions) is posted on
the Hewlett Packard web site at: http://www.hp.com/go/green. These
instructions may be used by recyclers and other WEEE treatment facilities
QuickSpecs
HP Managed Power Distribution Units (maPDU)
Technical Specifications
c04376673 DA 15069 Worldwide Version 1 September 29, 2014
Page 11
as well as HP OEM customers who integrate and re-sell HP equipment.
© Copyright 2014 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products
and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or
editorial errors or omissions contained herein.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Hewlett Packard Enterprise H8B50A Datasheet

Category
Power distribution units (PDUs)
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI