Blood pressure monitor
Instruction manual ....................2
ESPANOL
Tensiómetro
Manual de instrucciones ........20
Model BM 35
Item # 708884
Modelo BM 35
Número de artículo # 708884
READ THIS MANUAL COMPLETELY AND
CAREFULLY BEFORE USING THIS PRODUCT
Keep this manual in a safe location for future reference
LEA TODO ESTE MANUAL CON ATENCIÓN ANTES
DE USAR ESTE PRODUCTO
Conserve este manual en un lugar seguro
para consultarlo en el futuro
2
ENGLISH
IMPORTANT SAFETY NOTES
Signs and symbols
The following signs appear in the Safety Section (pages 2, 3, 4, 5)
and in this manual on pages 8, 9, 10, 12, 13, 15, 17.
READ THIS ENTIRE MANUAL, THE SAFETY SECTION AND ALL
INSTRUCTIONS AND WARNINGS COMPLETELY AND CARE-
FULLY BEFORE USING THIS PRODUCT. FOLLOW ALL SAFETY
INSTRUCTIONS AND WARNINGS TO AVOID HAZARDOUS SITU-
ATIONS AND TO MAKE CORRECT USE OF THIS PRODUCT.
WARNING:
•
Consultyourphysicianbeforestartingtomeasureyourblood
pressure.
•
Readandunderstandallinstructionsandwarningsbeforeusing
thisdevice.
•
Likeanyoscillometricbloodpressuremeasurementdevices,
certainmedicalconditionscanaffectthemeasurementac-
curacy,amongothers:
–disorderofthecardiacrhythm
–verylowbloodpressure
–patientsinshock
–patientswithverylowbloodperfusion
–diabetes
–vesselanomalies
–peoplewithelectricalimplants,suchasacardiacpace-
maker
–womenwhoarepregnant.
Duetotheirconditiontheoscillometricmeasurementmethod
canproduceincorrectreadings.Thisrepresentsariskforyour
health,sincevaluesmaybeinterpretedincorrectly.Alwayscon-
sultyourphysiciantodeterminewhatwillbesuitableforyou.
•
NevertrytoadaptorplugthisdevicetotheACline.Thisdevice
isbatterypowered.
•
Thisproductdoesnotandisnotintendedtoprovideamedical
diagnosis.Measurementresultsareforreferenceonly.Self-
diagnosisandtreatment,e.g.regardingmedication,using
measuredresultsrepresentariskforyourhealth.Alwayscon-
sultwithalicensedphysicianfordeterminationofappropriate
medicationanddosagethereof.Followtheinstructionsofyour
physicianorlicensedhealthcareprovider.Ifyouhaveorsuspect
thatyouhaveamedicalproblem,promptlyconsultyourphys-
ician.Ifyouhaveanemergencypleasecall911immediately.
WARNING
WARNINGindicatesahazardous
situationwhich,ifnotavoided,
couldresultindeathorserious
injury.
CAUTION
CAUTIONindicatesahazardous
situationwhich,ifnotavoided,may
resultinminorormoderateinjury.
NOTICE
NOTICEaddressespracticesnot
relatedtopersonalinjury,suchas
productand/orpropertydamage.
3
WARNING:
•
Onlyaphysicianoratrainedhealthcareprofessionalwhois
familiarwithyourmedicalhistoryisabletoaccuratelyinterpret
yourbloodpressuremeasurements.Consultyourphysician
beforestartingbloodpressuremonitoring.
•
Thisproductisnotintendedtoserveasasubstituteforthe
adviceofaphysicianormedicalprofessional.Thisproductis
notintendedtosubstituteforregularmedicalcheckups.Con-
tactyourphysicianforspecificinformationaboutyourblood
pressure.
•
Pleasenotethattechnicallyrelatedmeasuringtolerancesare
possible.Pleaseseesection11.TechnicalSpecifications”for
details.
•
Anycuffrelatedbloodpressuremeasurementinhighrepetition
rates,canleadtoseveremeasurementsideeffects,e.g.
–anervalcompressionwithtemporaryarm/handparalysis
thereleaseofanarterialorvenousthrombus,whichcancause
alifethreateningsituation.
Pleasecontactyourphysicianaboutthespecificrisksofcuff
pressureinyourspecificcase.
•
The‘irregularheartbeat’functiondoesnotreplaceacardiac
examination,butmayhelptodetectpotentialheartrateir-
regularitiesatanearlystage.Alwaysconsultyourphysicianto
determinewhatwillbesuitableforyou.
•
The‘irregularheartbeat’functionisnotdesignedfordiagnos-
ingortreatinganarrhythmicdisorder.Arrhythmiacanonlybe
ascertainedbyalicensedphysician.
•
TheRiskCategoryIndicatorchartisnotintendedtoreplacea
medicaldiagnosis.Thischartisonlyareferencefordifferent
classificationsofbloodpressure.
•
Ifyounoticeabnormalorsuspiciousvariationsinbloodpres-
suremeasurements,consultyourphysicianimmediately.
•
Womenwhounderwentabreastoraxillarlymphnoderemoval
operationshouldconsultaphysicianorlicensedhealthcare
providerbeforestartingbloodpressuremeasurements.
•
Priortouse,youhavetoensurethatthebloodpressuremonitor
isfreeofdamage.Ifindoubt,donotusetheunitandcontact
customerserviceat1-800-536-0366.
•
Thisdeviceisintendedonlyforpersonal,non-commercial,adult
useinmeasuringbloodpressureandheartrate.Donotusethe
productforanyotherpurpose.Thisproductisnotintended
foruseinahospital,physician’soffice,oranyotherhealth
carefacility.
•
Theunitmustbeusedinaccordancetothespecifiedambient
conditions,otherwisetheaccuracyofreadingsmightbeaffect-
ed.Seesection“8.Care,maintenanceandstoringtheinstru-
ment”andsection“11.TechnicalSpecifications”fordetails.
•
Donotwrapthecuffaroundbodypartsotherthanyourupper
leftarm.Misuserepresentsarisktoyourhealth.
•
Usethismonitoronlyonhumans.
•
Swallowingbatteriesand/orbatteryfluidcanbeextremely
dangerous.Keepthebatteriesandtheunitoutofthereachof
childrenanddisabledpersons.Shouldanypersonswallowa
batteryand/orbatteryfluid,pleasecall911immediately.
•
Batteriesshouldnotbechargedorreactivatedbyanyother
means.Thebatteriesmayexplode.
•
Batteriesshouldnotbetakenapart,throwninthefireorshort
circuited.Thebatteriesmayexplode.
•
Shouldbatteryfluidleakandcomeintocontactwithyoureyes
orskinimmediatelyrinsewithplentyofcleanwater.Please
call911immediately.
•
Thisproductisnotintendedforusebyoronchildren,toddlers
andinfantsoronpersonswhocannotexpresstheirconsent,
e.g.personswithmentaldisordersorthelike.Consultyour
physicianforalternativemethodsofmeasuringachild’sblood
pressure.
4
WARNING:
•
Thisproductisnotatoy.Keepitoutofreachofchildren,tod-
dlers,andinfants.
•
Keeptheproductoutofthereachofpets.
•
Packagingmaterialsareadeadlyhazardforchildrenandcan
causesuffocation.Removeallpackagingmaterialsimmediately
andkeepthemawayfromchildrenatalltimes.
•
Thisproductcontainssmallpartsthatmaypresentachoking
hazardtochildren.Keeptheunitandallpartsoutofreachof
children.NEVERLEAVECHILDRENORTHOSEWHOREQUIRE
CLOSESUPERVISIONUNATTENDEDWITHTHISDEVICE.
•
Thetubingpresentsastrangulationhazard.Keepthisproduct
awayfromchildrenandthosewhorequireclosesupervision,
e.g.peoplewithmentaldisorders.NEVERLEAVECHILDREN
ORTHOSEWHOREQUIRECLOSESUPERVISIONUNATTEND-
EDWITHTHISDEVICE.
•
Donotdrapetubearoundneck.Thispresentsastrangulation
hazard.
•
Peoplewithdisabilities,activitylimitations,orwhoarephysic-
allyfrail,shouldbeassistedbyanotherpersonwhenusing
thisunit.
•
Propercuffsizeisimportantforaccuratemeasurements.Only
usethedeviceonadultswhohavetherightupperarmcircum-
ferenceforthisinstrument.Seesection“11.TechnicalSpecifi-
cations”forsuitablearmcircumferences.
•
Donotuseanycuffs,tubes,partsandaccessoriesotherthan
thoseexplicitlyrecommendedbythemanufacturerforuse
withthisproduct.Partsandaccessoriesnotapprovedforuse
withthedevicemaycausedamagetoyourhealthandtothe
product.
•
Electromagneticinterference:Avoidstrongelectricalorelec-
tromagneticfieldsinthedirectvicinityofthedevice(e.g.mo-
biletelephones,microwaveovens)whileitisinoperation,as
inaccuratemeasurementsmayresult.Topreventsuchinterfer-
ence,usetheunitatasufficientdistancefromsuchdevices
orturnthedevicesoff.
•
Donotmeasureyourbloodpressurewhileoperatingavehicle
orinanysituationwhichrequiresyourfullattention.
CAUTION:
•
Thedeviceshouldnotbeusedwhenyourarmhasbeenwound-
ed/injuriedorwhenacatheterhasbeeninserted.Suchuse
mayresultininjury.
•
Removeanykindofupperarmjewelryorthelikebeforetaking
ameasurement.Thiscouldcausebruises.
•
Donotplacethearmcuffoverheavyclothing(e.g.ajacketor
sweatersleeve)asthebloodpressuremonitorwillnotbeable
totakeapropermeasurementandthereisanelevateddanger
ofacquiringhematomaorskinmarksduringthecourseofthe
measurement.
•
Incasethecuffdoesnotstopinflating,interruptthemeasure-
mentbypressingtheON/OFFbutton andopenthecuff
atonce.
•
Ifabatteryhasleakeddonottouchthebatteryfluid.Avoidskin
contact(e.g.putonprotectivegloves)andcleanthebattery
compartmentwithadrycloth.
•
Donotdisassembletheunit,itmayresultininjuries.
•
Whenapplyingthearmcuff,makesuretherearenowrinkles
inthecuff.Thiscouldcausebruises.
•
Donotexertanykindofpressureonthehoseduringmeasure-
ment,e.g.layingyourarmsoranyotherobjectonthehose.
Thiscouldcauseincorrectmeasurements.
•
Bloodpressuremeasurementscanleadtotemporarymarks
ontheskinatthesiteofthecuffplacement.Thisisespecially
thecaseinhighrepetitionrates,inhypertonicpatientsandin
patientswithweakheartrates.Inrarecasesamarkmaypersist
foracoupleofdays.Pleasecontactyourphysicianaboutthese
specificrisksofcuffpressureinyourspecificcase.
5
CAUTION:
•
Forhygienicreasonsthecuffisintendedonlyfortheuseby
oneperson.
NOTICE:
•
Thebloodpressuremonitorismadeupofprecisionelectronic
components.Accuracyofreadingsandtheinstrument’sser-
vicelifedependoncarefulhandling.Protecttheunitagainst
hardknocks(e.g.droppingtheunit),moisture,water,dirt,dust,
chemicals,extremehotorcoldtemperatures,majortemper-
aturefluctuations,directexposuretosunlightandheatsources
whicharetooclose(e.g.stoves,heatingradiators).Thismay
damagetheunit.Thedevicemustbestoredinthespecified
ambientconditions.Pleaseseesection“8.Care,maintenance
andstoringtheinstrument”andsection11.TechnicalSpeci-
fications”fordetails.
•
Donotuseanyaggressivesolvents,cleaningagents,deter-
gentsoranyotherstrongchemicalstocleanthedevice.
•
Neverimmerseandorspillwateroranyotherliquidontothe
monitororanycomponents,otherwiseliquidwillenteritand
causedamage.
•
Donotwashtheunitinawashingmachine,dishwasheror
tumbledryer.
•
Observethelocalregulationsformaterialdisposal.Disposeof
thedevice,componentsandoptionalaccessoriesaccording
toapplicablelocalregulations.Unlawfuldisposalmaycause
environmentalpollution.
•
Batteriescancontaintoxinsthatareharmfultotheenviron-
ment.Alwaysdisposeofbatteriesinaccordancewithapplic-
ablelocalregulations.Donotdisposeofbatterieswithnormal
householdwaste.
•
Alwaysusethesizeandtypeofbatteryindicated.Theuseof
otherbatterieswilldamagethedevice.
•
Neverusedifferenttypesofbatteries,batterybrandsorbat-
terieswithdifferentcapacities.Thismaydamagetheunit.You
shouldpreferablyusealkalinebatteries.
•
Neveruserechargeablebatteries.Thismaydamagetheunit.
•
Alwaysreplaceallbatteriesatthesametimeandusebatteries
ofthesametype.
•
Replaceweakbatteriesbeforetheydischargecompletely.When
appearsinthedisplaypleasechangethebatteries.
•
Leakingbatteriesmaydamagethedevice.Ifyoudonotintend
tousetheunitforlongerperiods,removethebatteriesfromthe
batterycompartmentbeforeplacingthedeviceinstorage.
•
Neverattempttorepair,openand/ordisassembletheunit
(includingarmcuffandoptionalaccessory)oradjustityour-
self.Thismaydamagetheunitandimpairthefunctions.Ifyou
needtohavetheunitrepaired,pleasecontactourcustomer
service.Pleaseseewarrantyforservicecontact.Beforesub-
mittinganycomplaint,firstcheckthebatteriesandreplace
themifnecessary.
•
Changesormodificationstothedevicewillnullifytheuser
warranty.
•
Donotdroporinsertanyobjectintoanyopeningorhose.
Thismaydamagetheunit.
•
Donotpressthebuttonswithexcessiveforceorwithpointed
objects.
6
Contents
IMPORTANT SAFETY NOTES .....................................................2
WARNING ..............................................................................2
CAUTION ................................................................................4
NOTICE ..................................................................................5
1. Getting to know your instrument .........................................6
2. Package Contents .................................................................7
3. Device description .................................................................7
3.1 Unit ....................................................................................7
3.2 Display Explanations .........................................................7
4. Prepare measurement ..........................................................8
4.1 Inserting/Replacing batteries ............................................8
4.2 Setting date and time ........................................................8
5. Measuring blood pressure ....................................................9
5.1 Positioning cuff ............................................................... 10
5.2 Correct posture ...............................................................11
5.3 Select memory ................................................................11
5.4 Taking Measurement .......................................................11
5.4.1 General Notes ..............................................................11
5.4.2 Taking Measurement ....................................................12
6. Evaluating results ................................................................12
6.1 Irregular heartbeat symbol ..............................................13
6.2 Risk Category Indicator ...................................................13
7.
Saving, retrieving and deleting results .................................. 14
8. Care, maintenance and storing the instrument ................15
9. Error messages / troubleshooting ......................................16
10. FCC Statement ....................................................................16
11. Technical Specifications .....................................................17
12. Warranty ...............................................................................18
SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE
If the instruction manual is damaged or if you no longer have the
instruction manual in your possession, please contact customer
service at 1-800-536-0366.
Dear Customer,
Congratulations on your purchase of this CVS/pharmacy
®
blood
pressure monitor. Please read and understand these instructions
completely and carefully before using this product and keep them
for later reference. Be sure to make them accessible to other users
and observe the information they contain.
1. Getting to know your instrument
The upper arm blood pressure monitor is used for non-invasive
measurement and monitoring of adults’ arterial blood pressure.
You can use it to measure your blood pressure quickly and eas-
ily, storing the results and displaying the progression of readings
together with the average.
The values determined are classified and graphically evaluated
according to the blood pressure standards established by the
U.S. department of Health and Human Services and the
National Institutes of Health.
INTENDED USE
This device uses the oscillometric method to measure systolic
and diastolic blood pressure as well as your heart rate. It’s rec-
ommend for use by people over the age of 18 and not to be
used on children.
7
2. Package Contents
Blood Pressure monitor BM35
Arm cuff (arm circumference 9” – 13” / 23 33 cm)
Operating instructions
Storage bag
4 x 1.5 V AAA battery
3. Device description
3.1 Unit
1. Cuff tube
2. Cuff
3. Cuff connector
4. Cuff connector port
(left side)
5. Memory button MEM
6. ON/OFF button
7. Display
8. Risk category indicator
9. Function key
10. Adjustment button “+”
3.2 Display Explanations:
1. Time and date
2. Average of the last three
measurements
3. mmHg unit
4. “Change battery” icon
5. Number of memory
space
6. Irregular heartbeat icon
7. Measured heart rate
8. Systolic pressure
9. Diastolic pressure
10. Risk category indicator
11. Error icon EE
12. Icon for users 1, 2
13. Heart rate icon
For product information, questions or customer service call toll
free 1-800-536-0366.
8
1 32
4
5
6
9
10
7
12
EE
11
13
1
4
6
7
5
8
10
9
3
2
PM
8
4. Prepare measurement
4.1 Inserting/Replacing batteries
WARNING:
•
Swallowingbatteriesand/orbatteryfluidcanbeextremely
dangerous.Keepthebatteriesandtheunitoutofthereachof
childrenanddisabledpersons.Shouldanypersonswallowa
batteryand/orbatteryfluid,pleasecall911immediately.
•
Batteriesshouldnotbechargedorreactivatedbyanyother
means.Thebatteriesmayexplode.
•
Batteriesshouldnotbetakenapart,throwninthefireorshort
circuited.Thebatteriesmayexplode.
•
Shouldbatteryfluidleakandcomeintocontactwithyoureyes
orskinimmediatelyrinsewithplentyofcleanwater.Please
call911immediately.
CAUTION:
•
Ifabatteryhasleakeddonottouchthebatteryfluid.Avoidskin
contact(e.g.putonprotectivegloves)andcleanthebattery
compartmentwithadrycloth.
NOTICE:
•
Batteriescancontaintoxinsthatareharmfultotheenviron-
ment.Alwaysdisposeofbatteriesinaccordancewithapplic-
ablelocalregulations.Donotdisposeofbatterieswithnormal
householdwaste.
•
Alwaysusethesizeandtypeofbatteryindicated.Theuseof
otherbatterieswilldamagethedevice.
•
Neverusedifferenttypesofbatteries,batterybrandsorbat-
terieswithdifferentcapacities.Thismaydamagetheunit.You
shouldpreferablyusealkalinebatteries.
•
Neveruserechargeablebatteries.Thismaydamagetheunit.
•
Alwaysreplaceallbatteriesatthesametimeandusebatteries
ofthesametype.
•
Replaceweakbatteriesbeforetheydischargecompletely.When
appearsinthedisplaypleasechangethebatteries.
•
Leakingbatteriesmaydamagethedevice.Ifyoudonotintend
tousetheunitforlongerperiods,removethebatteriesfromthe
batterycompartmentbeforeplacingthedeviceinstorage.
Note: You can only operate the blood pressure monitor with bat-
teries. Note that it is only possible to save data when your blood
pressure monitor is receiving power. As soon as the batteries are
dead, date and time on the blood pressure monitor are lost.
Remove the battery cover from the
back of the monitor.
Clean the battery contacts and those
of the device prior to installation with
a soft dry cloth.
Insert or replace only four 1.5 V “AAA
alkaline batteries. Make absolutely
sure that you insert them with the cor-
rect polarity (+/-) as indicated (see the
diagram inside the battery compartment). Do not use other types
of batteries.
Replace the battery cover carefully.
If the battery change is continuously illuminated, measure-
ment is no longer possible and you must replace all the batteries.
Once batteries have been removed from the device, the date and
time must be reset. Memories (if any) will not be deleted during
battery replacement.
4.2 Setting date and time
It is vital to set the date and time. This is the only way that measure-
ments can be saved and recalled with the correct date and time.
The time is shown in 12 hour format.
4 x AAA (LR03) 1.5 V
9
Proceed as follows to set the date and time:
Switch on the blood pressure monitor with the button.
Press the function key for over 5 seconds .
The month starts flashing. Change the month by pressing the “+”
button. Each press will increase the number by one in a cycling
manner. Set the month 1 to 12 and confirm with the function
key .
Set the day (1, 2, 3, ..., 31), hour (1, 2, 3, ..., 11, 12
PM
, 1
PM
, ...,
11
PM,
12) and minute (00, 01, 02, 03, ..., 59) in the same manner
and confirm in each case with the function key
.
5. Measuring blood pressure
WARNING:
•
Consultyourphysicianbeforestartingtomeasureyourblood
pressure.
•
Readandunderstandallinstructionsandwarningsbeforeusing
thisdevice.
•
Likeanyoscillometricbloodpressuremeasurementdevices,
certainmedicalconditionscanaffectthemeasurementac-
curacy,amongothers:
–disorderofthecardiacrhythm
–verylowbloodpressure
–patientsinshock
–patientswithverylowbloodperfusion
–diabetes
–vesselanomalies
–
peoplewithelectricalimplants,suchasacardiacpacemaker
–womenwhoarepregnant.
Duetotheirconditiontheoscillometricmeasurementmethod
canproduceincorrectreadings.Thisrepresentsariskforyour
health,sincevaluesmaybeinterpretedincorrectly.Alwayscon-
sultyourphysiciantodeterminewhatwillbesuitableforyou.
•
NevertrytoadaptorplugthisdevicetotheACline.Thisdevice
isbatterypowered.
•
Thisproductisnotintendedtoserveasasubstituteforthe
adviceofaphysicianormedicalprofessional.Thisproductis
notintendedtosubstituteforregularmedicalcheckups.Con-
tactyourphysicianforspecificinformationaboutyourblood
pressure.
•
Womenwhounderwentabreastoraxillarlymphnoderemoval
operationshouldconsultaphysicianorlicensedhealthcare
providerbeforestartingbloodpressuremeasurements.
•
Priortouse,youhavetoensurethatthebloodpressuremonitor
isfreeofdamage.Ifindoubt,donotusetheunitandcontact
customerserviceat1-800-536-0366.
•
Thisdeviceisintendedonlyforpersonal,non-commercial,adult
useinmeasuringbloodpressureandheartrate.Donotusethe
productforanyotherpurpose.Thisproductisnotintended
foruseinahospital,physician’soffice,oranyotherhealth
carefacility.
•
Theunitmustbeusedinaccordancetothespecifiedambient
conditions,otherwisetheaccuracyofreadingsmightbeaffect-
ed.Seesection“8.Care,maintenanceandstoringtheinstru-
ment”andsection“11.TechnicalSpecifications”fordetails.
•
Donotwrapthecuffaroundbodypartsotherthanyourupper
leftarm.Misuserepresentsarisktoyourhealth.
•
Usethismonitoronlyonhumans.
•
Thisproductisnotintendedforusebyoronchildren,toddlers
andinfantsoronpersonswhocannotexpresstheirconsent,e.g.
personswithmentaldisordersorthelike.Consultyourphysician
foralternativemethodsofmeasuringachild’sbloodpressure.
•
Donotdrapetubearoundneck.Thispresentsastrangulation
hazard.
•
Peoplewithdisabilities,activitylimitations,orwhoarephysic-
allyfrail,shouldbeassistedbyanotherpersonwhenusing
thisunit.
10
WARNING:
•
Propercuffsizeisimportantforaccuratemeasurements.Only
usetheinstrumentonadultpersonswhoseupperarmhasthe
rightupperarmcircumferencefortheinstrument.Seesec-
tion“11.TechnicalSpecifications”forsuitablearmcircumfer-
ences.
•
Donotuseanycuffs,tubes,partsandaccessoriesotherthan
thoseexplicitlyrecommendedbythemanufacturerforuse
withthisproduct.Partsandaccessoriesnotapprovedforuse
withthedevicemaycausedamagetoyourhealthandtothe
product.
•
Electromagneticinterference:Avoidstrongelectricalorelec-
tromagneticfieldsinthedirectvicinityofthedevice(e.g.mo-
biletelephones,microwaveovens)whileitisinoperation,as
inaccuratemeasurementsmayresult.Topreventsuchinterfer-
ence,usetheunitatasufficientdistancefromsuchdevices
orturnthedevicesoff.
•
Donotmeasureyourbloodpressurewhileoperatingavehicle
orinanysituationwhichrequiresyourfullattention.
CAUTION:
•
Thedeviceshouldnotbeusedwhenyourarmhasbeenwound-
ed/injuriedorwhenacatheterhasbeeninserted.Suchuse
mayresultininjury.
•
Removeanykindofupperarmjewelryorthelikebeforetaking
ameasurement.Thiscouldcausebruises.
•
Donotplacethearmcuffoverheavyclothing(e.g.ajacketor
sweatersleeve)asthebloodpressuremonitorwillnotbeable
totakeapropermeasurementandthereisanelevateddanger
ofacquiringhematomaorskinmarksduringthecourseofthe
measurement.
•
Incasethecuffdoesnotstopinflating,interruptthemeasure-
mentbypressingtheON/OFFbutton andopenthecuff
atonce.
•
Whenapplyingthearmcuff,makesuretherearenowrinkles
inthecuff.Thiscouldcausebruises.
•
Donotexertanykindofpressureonthehoseduringmeasure-
ment,e.g.layingyourarmsoranyotherobjectonthehose.This
couldcauseincorrectmeasurements.
•
Bloodpressuremeasurementscanleadtotemporarymarks
ontheskinatthesiteofthecuffplacement.Thisisespecially
thecaseinhighrepetitionrates,inhypertonicpatientsandin
patientswithweakheartrates.Inrarecasesamarkmaypersist
foracoupleofdays.Pleasecontactyourphysicianaboutthese
specificrisksofcuffpressureinyourspecificcase.
•
Forhygienicreasonsthecuffisintendedonlyfortheuseby
oneperson.
5.1 Positioning cuff
Note: Always properly position the Arm Cuff on the arm at heart
level, according to the following instructions.
Fit the cuff round your bare left upper
arm. Do not place the arm cuff over heavy
clothing (e.g. a jacket or sweater sleeve)
as the blood pressure monitor will not be
able to take a proper measurement. Blood
circulation in the arm should not be re-
stricted by tight clothing or other objects.
The cuff should be placed on the upper
arm so that the lower edge is approx.
0.8” to 1.2” (2 to 3 cm) above the bend
of the elbow and above the artery. The
tube should be in line with the center of
the palm.
11
Now place the free end of the cuff snugly,
but not too tightly, around the arm, and fix
it with the Velcro fastener. The cuff should
be fitted tight enough to allow just two fin-
gers to fit beneath the cuff.
Insert the cuff tubing into the socket on
the left side of the unit. Make sure it is in-
serted securely in the main unit and that
there are no kinks in the cuff tubing.
Important:
This instrument should only be operated with the original
cuff. The cuff included with the device is suitable for an upper arm
circumference of 9” to 13” (23 to 33 cm). A larger cuff for upper arm
circumferences from 13” to 17” (33 to 43 cm) is available online at
www.cvs.com.
Replacement cuffs from other models cannot be used with this mod-
el. Doing so will result in inaccurate readings or error messages.
5.2 Correct posture
Rest at least for 5 minutes before each meas-
urement. Otherwise there may be erroneous
results.
Sit comfortably with your left arm resting on
a flat surface. Always make sure that the cuff
is on a level with your heart.
In order not to distort the result, it is important
to keep still during the measurement and not
talk. The most precise measurement results
are obtained if you strive for a relaxed meas-
urement situation. You may close your eyes
and breathe calmly during the measurement.
•
Please note that any muscle movement dur-
ing inflation or deflation can cause measurement error.
5.3 Select memory
Switch on the blood pressure monitor with the button. Select
the required memory space by pressing the function key “+”. You
have two memories (60 memory spaces each) in order to save
the test results of 2 different users separately, or alternatively save
measurements in the morning and evening separately.
5.4 Taking Measurement
5.4.1 General Notes
For reliable monitoring and reference of blood pressure, keeping
long-term records is recommended.
•Tominimizemeasurementvariationsduetophysicalactivity,rest
at least 5 minutes before measuring your blood pressure (or 15
minutes after strenuous activity). You should not be physically tired
or exhausted while taking measurement.
In order to obtain a resting condition blood pressure, avoid eating,
drinking alcohol and caffeinated beverages, smoking, exercising,
and bathing for at least 30 minutes before taking a measure-
ment.
Stress raises blood pressure.
Perform measurements in a quiet and relaxed environment at
room temperature.
Always wait at least 5 minutes between measurements to allow the
blood circulation in your arm to return to normal. You may need to
increase the wait time depending on your individual physiological
characteristics. Because of normal physiologic changes and the
many external factors influencing blood pressure, it is unusual to
obtain identical blood pressure measurements, even when taken
a few minutes apart. Speak with your physician to determine what
is affecting your blood pressure and which variation may be seen
as normal in your case.
The accuracy of any blood pressure measurement with this device
can be affected by a multitude of causes. Some can be avoided,
some have to be accepted at the time of measurement. Speak
12
with your physician about possible causes affecting your blood
pressure.
Do not inflate the cuff unless wrapped around arm.
When taking repeat measurements, make sure to select the same
user so that the measurements are recorded in the appropriate
memory.
If no button is pressed for one minute the automatic shut-off
function shuts off the unit in order to preserve the batteries.
Do not touch the unit, the tube and cuff and/or press any but-
tons when measurement is in progress, except for stopping the
measurement. Doing so may cause incorrect readings.
5.4.2 Taking Measurement
Note: If you are using the unit for the first time, please remove the
protective film from the display.
Put on the cuff around your bare left upper arm as described previ-
ously and assume the position in which you want to carry out the
measurement.
Using the buttons “+”, select the user memory 1 or 2. Start the
measurement process by pressing the button. After checking
the display with all digits lighting up, the monitor will automatically
inflate. During inflation the device already determines measured
values used to estimate the required inflation pressure.
Note:
This monitor will re-inflate automatically if the system detects
that your body requires more pressure for measurement.
Then the pressure in the cuff is slowly released, the heart rate icon
is flashing and the heart rate is measured. As the cuff deflates,
decreasing numbers appear on the display.
When the measurement has been completed, the cuff will deflate
entirely. The heart rate, the systolic and the diastolic blood pres-
sure with RISK CATEGORY INDICATOR bar are displayed.
You can interrupt measurement at any time by pressing the
button. The cuff will deflate immediately after the button is
pressed.
The E_ icon appears if it has not been possible to perform the
measurement properly. Observe the section in these instructions
on error messages/troubleshooting and repeat the measure-
ment.
The device switches off automatically after 1 minute.
Wait at least 5 minutes before taking another measurement.
6. Evaluating results
WARNING:
•
Thisproductdoesnotandisnotintendedtoprovideamedical
diagnosis.Measurementresultsareforreferenceonly.Selfdiag-
nosisandtreatment,e.g.regardingmedication,usingmeasured
resultsrepresentariskforyourhealth.Alwaysconsultwithali-
censedphysicianfordeterminationofappropriatemedication
anddosagethereof.Followtheinstructionsofyourphysicianor
licensedhealthcareprovider.Ifyouhaveorsuspectthatyouhave
amedicalproblem,promptlyconsultyourphysician.Ifyouhave
anemergencypleasecall911immediately.
•
Onlyaphysicianoratrainedhealthcareprofessionalwhoisfam-
iliarwithyourmedicalhistoryisabletoaccuratelyinterpretyour
bloodpressuremeasurements.Consultyourphysicianbefore
startingbloodpressuremonitoring.
•
Pleasenotethattechnicallyrelatedmeasuringtolerancesare
possible.Pleaseseesection11.TechnicalSpecifications”for
details.
•
Ifyounoticeabnormalorsuspiciousvariationsinbloodpres-
suremeasurements,consultyourphysicianimmediately.
13
Note: A single measurement does not provide an accurate indica-
tion of your true blood pressure. You need to take and record several
readings over a period of time. Try to measure your blood pressure
at the same time each day for consistency.
6.1 Irregular heartbeat symbol
WARNING:
•
The‘irregularheartbeat’functiondoesnotreplaceacardiac
examination,butmayhelptodetectpotentialheartrateir-
regularitiesatanearlystage.Alwaysconsultyourphysicianto
determinewhatwillbesuitableforyou.
•
The‘irregularheartbeat’functionisnotdesignedfordiagnos-
ingortreatinganarrhythmicdisorder.Arrhythmiacanonlybe
ascertainedbyalicensedphysician.
This symbol indicates that certain heart rate irregularities were
detected during the measurement.
In general, an irregular heartbeat rhythm is defined as a rhythm that
is more than 25% slower or 25% faster from the average rhythm
detected while the monitor is measuring the systolic and diastolic
blood pressure.
In order to filter the unstable status of user and avoid affecting the
detection of heart rate from any movement, shaking or talking in the
beginning of measurement, the method of averaging heart beat inter-
vals of subject device is calculated with the three proper heart beat
pulses detected in the beginning of measurement and that is different
from a strict mathematical averaging of all recorded intervals.
At least 3 beats with at least 25% difference from the average heart
beat interval will generate the IHB icon on the screen.
NOTE:
Talking, moving, shaking or an irregular
heart rate
during the meas-
urement can result in the appearance of this symbol.
Repeat the measurement if the flashing icon is displayed after the
measurement. Please note that you should rest at least 5 minutes
between measurements and not talk or move during the meas-
urement. If the icon continues to be displayed in subsequent
readings, we recommend you to consult your physician in order
to determine if it is cause for concern. Do not try to interpret read-
ings or attempt to treat any condition yourself. Always follow the
guidance of a health professional. If you have an emergency call
911 immediately.
6.2 Risk Category Indicator
WARNING:
•
TheRiskCategoryIndicatorchartisnotintendedtoreplacea
medicaldiagnosis.Thischartisonlyareferencefordifferent
classificationsofbloodpressure.
This device is equipped with a Risk Category Indicator which clas-
sifies your blood pressure measurements into four stages (Normal,
Pre-hypertension, Stage 1 Hypertension to Stage 2 Hypertension)
based on the blood pressure standards established by the U.S. De-
partment of Health and Human Services and the National Institutes
of Health. Besides, for your and your loved ones’ health, we further
classify the four stages into numeral ranges, which sorts out hyper-
tension symptoms more clearly. Moreover, for your convenience
and readability, we use four corresponding colors to represent your
measuring result. Refer to below comparison chart for details:
14
Note: This standard/classification, however, is a general guideline
as an individual’s blood pressure varies among different people, age
groups, etc. Please consult your physician for proper diagnosis.
After each measurement is completed the bar graph in the display
and the scale on the unit indicate the range of the blood pressure
which has been recorded. Check up the comparison chart above
to see what stage your measuring result fits in.
Note: When a person’s systolic and diastolic pressures fall into
different categories, the higher category should apply.
e.g. systolic rate 181 & diastolic rate 99
Red category (Stage 2 Hypertension)
e.g. systolic rate 110 & diastolic rate 95
Red category (Stage 1 Hypertension)
For adults 18 and older who are not on medicine for high blood
pressure, are not having a short-term serious illness, and do not
have other conditions, such as diabetes and kidney disease. To
determine category of risk when systolic and diastolic readings fall
into two areas, use the higher of the two numbers for classification.
There is an exception to the above definition of high blood pressure
for people with diabetes and chronic kidney disease. A blood pres-
sure of 130/80 mmHg or higher is considered high blood pressure
for those individuals.
Note:
The above table is not exact for classification of blood pressure and
it’s intended to be used as a guide in understanding non-invasive
blood pressure measurements.
Usually this is not a cause for concern; however we recommend you
consult with your physician for proper diagnosis or seek medical
advice. Please note that this device does not diagnose hypertension,
and it is only for user reference on blood pressure monitoring.
7.
Saving, retrieving and deleting results
The results of each successful measurement are stored together
with date and time. Each user can store up to 60 items of meas-
ured data. With more than 60 items of measured data, the oldest
items of measured data are dropped.
Select the desired user memory by pressing the MEM button and
then the “+” button. Press the MEM button again to display the
average of the last 3 measurements in the user memory. If you
continue pressing the MEM button, the latest individual results are
displayed with the
risk category indicator
, irregular heart beat icon,
date and time. Press MEM button to read the following measure-
ments in sequence. Data is recalled from the latest measurement
to the oldest.
To stop reading the memory, press the button.
Note:
If there is no data in the selected user, nothing (except date,
time and user number) will appear on the display.
To clear the memory, press the MEM button, then the display
shows no. 1. Press the “+” button to select the user memory and
confirm by pressing MEM again. Press and hold the “+” and
keys simultaneously for 5 seconds (the display will show CLA).
To confirm the data in the selected user has been erased, press
Stages of
Blood Pressure Levels
Systolic
(mmHg)
Diastole
(mmHg)
Color
Stage 2 Hypertension
≥180 ≥110 Red
160 –179 100 –109 Red
Stage 1 Hypertension 140 –159 90 – 99 Red
Pre-hypertension
130 –139 85 – 89 Yellow
120 –129 80 – 84 Light Green
Normal <120 <80 Dark Green
Source: U.S. department of Health and Human Services and the National Insti-
tutes of Health.
15
MEM button and no data should appear (except date, time and
the user number).
If you wish to change the user memory, see “Select memory”.
8. Care, maintenance and storing the instrument
WARNING:
•
Donotuseanycuffs,tubes,partsandaccessoriesotherthan
thoseexplicitlyrecommendedbythemanufacturerforuse
withthisproduct.Partsandaccessoriesnotapprovedforuse
withthedevicemaycausedamagetoyourhealthandtothe
product.
CAUTION:
•
Donotdisassembletheunit,itmayresultininjuries.
NOTICE:
•
Thebloodpressuremonitorismadeupofprecisionelectronic
components.Accuracyofreadingsandtheinstrument’sser-
vicelifedependoncarefulhandling.Protecttheunitagainst
hardknocks(e.g.droppingtheunit),moisture,water,dirt,dust,
chemicals,extremehotorcoldtemperatures,majortemper-
aturefluctuations,directexposuretosunlightandheatsources
whicharetooclose(e.g.stoves,heatingradiators).Thismay
damagetheunit.Thedevicemustbestoredinthespecified
ambientconditions.Pleaseseesection“8.Care,maintenance
andstoringtheinstrument”andsection11.TechnicalSpeci-
fications”fordetails.
•
Donotuseanyaggressivesolvents,cleaningagents,detergents,
solventsoranyotherstrongchemicalstocleanthedevice.
•
Neverimmerseandorspillwateroranyotherliquidontothe
monitororanycomponents,otherwiseliquidwillenteritand
causedamage.
•
Donotwashtheunitinawashingmachine,dishwasheror
tumbledryer.
•
Observethelocalregulationsformaterialdisposal.Disposeof
thedevice,componentsandoptionalaccessoriesaccording
toapplicablelocalregulations.Unlawfuldisposalmaycause
environmentalpollution.
•
Batteriescancontaintoxinsthatareharmfultotheenviron-
ment.Alwaysdisposeofbatteriesinaccordancewithapplic-
ablelocalregulations.Donotdisposeofbatterieswithnormal
householdwaste.
•
Neverattempttorepair,openand/ordisassembletheunit(in-
cludingarmcuffandoptionalaccessory)oradjustityourself.
Thismaydamagetheunitandimpairthefunctions.Ifyouneed
tohavetheunitrepaired,pleasecontactourcustomerservice.
Pleaseseewarrantyforservicecontact.Beforesubmittingany
complaint,firstcheckthebatteriesandreplacethemifneces-
sary.
•
Changesormodificationstothedevicewillnullifytheuser
warranty.
•
Donotdroporinsertanyobjectintoanyopeningorhose.This
maydamagetheunit.
•
Donotpressthebuttonswithexcessiveforceorwithpointed
objects.
To keep your digital blood pressure monitor in the best condition and
protect the unit from damage follow the directions listed below:
Clean your device and cuff carefully only with a slightly moistened
soft cloth and dry it immediately with a soft dry cloth. Do not
press.
When storing the device, make sure that no heavy objects are
placed on top of it.
Do not fold the cuff and tubing tightly. The cuff tube should not
have any sharp kinks and keep it away from sharp edges.
16
Iftheunitisstorednearfreezing,allowittoacclimatetoroom
temperature before use.
Always store the unit in the pouch after use.
This unit may not meet its performance specifications if stored
or used outside of the temperature and humidity ranges (see
section “11. Technical Specifications”).
Use the unit consistent with the instruction provided in this
manual.
9. Error messages / troubleshooting
If any abnormality arises during use, please check the following
points.
Error Display/
Symptoms
Possible Causes Correction
EE Pressure is lower than
40 mmHg or Effective
heart rate is lower than
4 beats.
Repeat the measure-
ment. Make sure that
the cuff is positioned
correctly, the cuff tube
is properly inserted and
that you do not move
or talk. Re-insert the
batteries if necessary,
or else replace them.
E1 The cuff is inflated for
longer than 25 seconds.
The cuff tube is not
inserted properly.
E2 Inflation pressure is
higher than 300 mmHg.
E3 Blood pressure is un-
usually high or low.
You move or talk dur-
ing the measurement
(in addition to E3, the
irregular heartbeat icon
appears in the
display).
Error Display/
Symptoms
Possible Causes Correction
Unit does not
turn on when
the
button
is pushed.
Batteries have run down. Replace the batteries.
Battery polarities
have been positioned
incorrectly.
Re-insert the batteries
in the correct position.
The unit is defective. Contact customer
Service. See warranty
section.
Batteries have run down. Replace the batteries.
Measurement
values appear
too high or too
low.
Blood pressure varies
constantly. Many factors
including stress, time of
day, how you wrap the
cuff, etc. may affect your
blood pressure.
Review the section
“5. Measuring Blood
Pressure”.
Note: If “EP” appears on the display please contact our customer
service. See warranty section.
Note: If the unit still does not work, contact customer service at
1-800-536-0366.
10. FCC Statement
This equipment has been tested and found to comply with the limits
for Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio or television receptions,
which can be determined by turning the equipment off and on.
17
The user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
11. Technical Specifications
Model-No. BM 35
Method of
Measurement
oscillometric, non-invasive blood pressure
measurement on the upper arm
Measurement
Range
cuff pressure range: 0 300 mmHg
blood pressure range: 40 280 mmHg
heart rate 40 –199 beats/minute
Accuracy of the
reading
systolic ± 3 mmHg / diastolic ± 3 mmHg /
heart rate ± 5% of the displayed value
Measuring
uncertainty
max. permissible standard deviation according
to clinical testing:
systolic: 8 mmHg /diastolic: 8 mmHg
Sets of Memory 2 x 60 memory places (120 memory total)
Unit Dimension L 5.3” x W 4.1” x H 2.1”
(L 135 mm x W 105 mm x H 53 mm)
Unit Weight approx. 0.48 lb (217 g)
CuffSize upper arm circumference approx. 9” 13”
(23 – 33 cm)
Note: large cuff (13” to 17” / 33 to 43 cm) is
available at customer service.
Operating
Temperature
+ 50 °F to 104 °F (+ 10 °C to + 40 °C),
15% to 90% RH
Storage- and trans-
port temperature
- 4 °F to 158 °F (- 20 °C to + 70 °C), ≤ 90% RH
Power Supply 4 x 1.5 V AAA-Batteries (alkaline type LR03)
Battery Life for approx. 250 measurements, depending on
blood pressure level or inflation pressure
Accessories storage bag, operating instructions,
4 AAA batteries
BF Classification
– Internally powered equipment
– BF type applied part
– IPXO
Not suitable for use in presence of flam-
mable anesthetic mixture with air or with
Oxygen or nitrous oxide
Continuous operation with short-time
loading
Key to symbols
WARNING! Readthesafety
informationandallinstructionsto
avoidseriousinjury.
application part Type BF
Discard the used product to the recyc-
ling collection point according to local
regulations.
Auto-shut-off 1 minute after last button operation
These specifications are subject to change without notice for pur-
pose of improvement.
This unit is in line with the International Standard
IEC 60601-1-2 and is subject to particular pre-
cautions with regard to electromagnetic compat-
ibility (EMC). Please note that portable and mobile
18
HF communication systems may interfere with this instrument. For
more details, please contact customer service.
Blood pressure measurements taken with this device are equivalent
to those obtained by a trained observer using the cuff/stethoscope
auscultation method and are within the accuracy limits prescribed
by the American National Standard for Electronic or Automated
Sphygmomano meters.
It is recommended the performance should be checked every
5 years or after repair. Please contact customer service.
12. Warranty
Limited Lifetime Warranty For Original Purchaser
Your CVS/pharmacy
®
Blood Pressure Monitor, Model BM35, ex-
cluding the cuff (incl. tube) and the batteries, is warranted to be free
from defects in materials and workmanship for the life of the product
under normal conditions of intended use and service. The cuff is
warranted to be free from defects in materials and workmanship
appearing within two years from date of purchase when the monitor
is used in accordance with the instructions provided with the unit.
This warranty extends only to the original retail purchaser and does
not extend to retailers or subsequent owners.
We will, at our option, repair or replace the CVS/pharmacy
®
Blood
Pressure Monitor, Model BM35, without additional charge, for any
part or parts covered by these written warranties. No refunds will
be given. Repair or replacement is our only responsibility and your
only remedy under this written warranty. If replacement parts for
defective materials are not available, the warrantor reserves the right
to make product substitutions in lieu of repair or replacement.
For warranty service contact our customer service department
at 1-800-536-0366 to provide a description of the problem. If the
problem is deemed to be within the scope of the limited lifetime
warranty, you will be asked to mail the product at your costs in its
original package with proof of purchase, your name, address and
phone number. If the problem is not deemed to be within the scope
of the limited lifetime warranty, we will provide a quotation for repair,
respectively, replacement and return shipping fees.
This warranty does not cover damage caused by misuse or abuse;
accident;theattachmentofunauthorizedaccessories; alteration
to the product; improper installation; misapplication; lack of rea-
sonablecarewithrespecttotheproduct;unauthorizedrepairsor
modifications; improper use of electrical/power supply; old worn
batteries; normal wear; loss of power; dropped product; malfunction
or damage of an operating part as a result of failure to comply with
instructions for use or to provide manufacturers recommended
maintenance; transit damage; theft; neglect; vandalism; or environ-
mental conditions; loss of use during the period the product is at
a repair facility or otherwise awaiting parts or repair; or any other
conditions whatsoever that are beyond the control of the warrantor.
This warranty is void if the product is ever used in a commercial or
business environment. The maximum liability of the warrantor under
this warranty is limited to the purchase price actually paid by the
customer for the product covered by the warranty, as confirmed
by proof of purchase, regardless of the amount of any other direct
or indirect damage suffered by the customer.
This warranty is effective only if the product is purchased and oper-
ated in the country in which the product is purchased. A product
that requires modifications or adoption to enable it to operate in any
other country than the country for which it was designed, manufac-
tured,approvedand/orauthorized,orrepairofproductsdamaged
by these modifications is not covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND
EXCLUSIVE WARRANTY. ANY IMPLIED WARRANTIES, OBLIGA-
TIONS, OR LIABILITES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO
THE DURATION OF THIS APPLICABLE WRITTEN WARRANTY.
19
Some states do not allow limitations on how long an implied war-
ranty lasts, so the above limitations may not apply to you.
IN NO EVENT SHALL THE WARRANTOR BE LIABLE FOR ANY
SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAM-
AGES FOR BREACH OF THIS OR ANY OTHER WARRANTY,
EXPRESS, IMPLIED OR ANY OTHER THEORY OF LIABILITY,
WHATSOEVER. Some states do not allow the exclusion or limita-
tion of special, incidental, or consequential damages, so the above
limitation may not apply to you.
Thewarrantordoesnotauthorizeanyone,including,butnotlimited
to, retailers, the subsequent consumer purchaser of the product
from a retailer or remote purchaser, to obligate the warrantor in any
way beyond the terms set forth herein.
This warranty does not extend to the purchase of opened, used,
repaired, repackaged and/or resealed products, including but not lim-
ited to sale of such products on Internet auction sites and/or products
by surplus or bulk resellers. Any and all warranties or guarantees shall
immediately cease and terminate in connection with any products
or parts thereof which are repaired, replaced, altered, or modified,
without the prior explicitly written consent of the warrantor.
This warranty gives you specific legal rights, and you may also have
other rights which may vary from state to state.
Made in China.
Questions or comments? Call toll free 1-800-536-0366.
Distributed by: CVS Pharmacy, Inc.
One CVS Drive, Woonsocket, Rl 02895
© 2011 CVS/pharmacy
www.cvs.com 1-800-shop-CVS
40
753.902 - 1012 Subject to error and change
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

CVS BM 35 User manual

Category
Blood pressure units
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages