© Munters AB, 2013 15
4.2
Ventilation table (Menu 92)
1 1 0 0 0 0 0 0 0 0 0 0 0 0.5 9.5 0 0
2 1 0 0 0 0 0 0 0 0 0 0 0 1.0 9.0 0 0
3 1 0 0 0 0 0 0 0 0 0 0 0 2.0 8.0 0 0
4 1 0 0 0 0 0 0 0 0 0 0 0 3.0 7.0 0 0
5 1 0 0 0 0 0 0 0 0 0 0 0 5.0 5.0 0 0
6 1 2 0 0 0 0 0 0 0 0 0 0 1.0 0.0 0 0
7 1 2 0 0 0 0 0 0 0 0 0 0 0.5 1.0 0 0
8 1 2 0 0 0 0 0 0 0 0 0 0 1.0 1.0 0 0
9 1 2 3 0 0 0 0 0 0 0 0 0 1.0 0.0 0 0
10 0 0 0 0 0 0 0 0 0 0 0 0 0.5 1.0 0 0
11 0 0 0 0 0 0 0 0 0 0 0 0 1.0 1.0 0 0
12 0 0 0 0 0 0 0 0 0 0 0 0 1.0 0.0 0 0
13 0 0 0 0 0 0 0 0 0 0 0 0 0.5 1.0 0 0
14 0 0 0 0 0 0 0 0 0 0 0 0 1.0 1.0 0 0
15 0 0 0 0 0 0 0 0 0 0 0 0 1.0 0.0 0 0
16 1 2 3 4 0 0 0 0 0 0 0 0 1.0 0.0 1.0 0
17 1 2 3 4 5 0 0 0 0 0 0 0 1.0 0.0 2.0 0
18 1 2 3 4 5 6 0 0 0 0 0 0 1.0 0.0 3.0 0
19 1 2 3 4 5 6 7 0 0 0 0 0 1.0 0.0 4.0 0
20 1 2 3 4 5 6 7 0 0 0 0 0 1.0 0.0 4.0 0
The
increases the fan power as ventilation requirements rise. The increments should be
proportional from level to level. This means that the ventilation increases about 50% to 100% at each
level. For example, at Level One a single fan is set to 0.5 minutes on and 9.5 minutes off. At Level Two, if
you set the fan to 1.0 minute on and 9.0 minutes off, there is a 100% increase. At a much higher level,
such as ventilation level 15, an increase from 4 fans to 6 fans represents a 50% increase in fan power.
Please review the example ventilation tables for this principle.
The ventilation table,
, defines the fan powered ventilation levels for the poultry house. This
includes variable speed, timer and on/off fans for up to 20 levels of ventilation. At each ventilation level,
a cycle timer can run the highest numbered fan group used at that level. With no values in the timer on
and off fields, or only an off time or only an on time, the
defaults to constant on operation.
Due to limited display size, the
shows only the on-off timer or the variable speed setting
at each level. Use
, item 4 to select which setting the
shows. However, both
settings remain in memory.
Transitional
Minimum
First Tunnel
Level