AIR COOLED CHIMNEY REQUIREMENTS
Use only DuraVent DuraChimney II brand of chimney.
W415-2251 / 08.24.17
Chimney Components Type
12” (30.5cm) Length Chimney Pipe
DuraChimney II 8DCA-12
18”(45.7cm) Length Chimney Pipe
DuraChimney II 8DCA-18
24” (61cm) Length Chimney Pipe
DuraChimney II 8DCA-24
36” (91.4cm) Length Chimney Pipe
DuraChimney II 8DCA-36
48” (121.9cm) Length Chimney Pipe
DuraChimney II 8DCA-48
15° Elbow Kit
DuraChimney II 8DCA-E15K
30° Elbow Kit
DuraChimney II 8DCA-E30K
Elbow Strap
DuraChimney II 8DCA-ES
Supplementary Support
DuraChimney II 8DCA-SS
Wall Strap
DuraChimney II 8DCA-WS
Stabilizer
DuraChimney II 8DCA-ST
Anchor Plate
DuraChimney II 8DCA-AP
Firestop
DuraChimney II 8DCA-FS
30° Wall Firestop
DuraChimney II 8DCA-FS30
Attic Insulation Shield
DuraChimney II 8DCA-IS
Roof Radiation Shield
DuraChimney II 8DCA-RRS
Chase Top Flashing
DuraChimney II 8DCA-CTF
Chase Top Collar
DuraChimney II 8DCA-CTC
Storm Collar (6-8”)
DuraChimney II 8DCA-SC
Chimney Cap
DuraChimney II 8DCA-VC
Air Housing
Wolf Steel NZAC8KT
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonreplaces.com
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
1
2
X6
You will need:
With 5/16” & 1/4” Driver Bit
Install air housing for air cooled chimney to the top of the
appliance using 6 screws (provided).
Install the anchor plate (using gasket provided with
appliance) and first length of chimney.
NZAC8KT
Air Cooled Chimney Installation Instructions for NZ5000
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonreplaces.com
Horizontal run may be:
5' (1.5m)
15' (4.6m)
20' (6.1m)
25' (7.6m)
Vertical rise is between:
6' (1.8m) & 10' (3m) max
3' (0.9m) & 6' (1.8m)
1' (0.3m) & 3' (0.9m)
0' (0m) & 1' (0.3m)
4
5
Install 4” hood through outside wall.* Fastening
hardware and sealant not supplied.
* Only 10 feet of aluminum flex vent is included with the 111KT outside air kit, for longer lengths, contact your authorized
Napoleon dealer.
X3
Connect and secure 4” aluminum flex vent to collar of
air housing, route to hood and secure with 3 screws
per connection.
W415-2251 / 08.24.17
0
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
5
(10)
10
(20)
15
(30)
20
(40)
25
(50)
AIR INTAKE FLEX
VENT
HORIZONTAL RUN
VERTICAL RISE
0
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
5
(10)
10
(20)
15
(30)
20
(40)
25
(50)
AIR INTAKE LINERS
HORIZONTAL RUN
VERTICAL RISE
AIR INTAKE FLEX
VENT
Install the 12¼” collar plate over the chimney with the
4 screws provided.
3
W415-2251 / 08.24.17
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonreplaces.com
EXIGENCES POUR LA CHEMINÉE REFROIDIE À L’AIR
Utilisez uniquement la margue DuraVent DuraChimney II de cheminée.
Composants de la cheminée Partie
Section de cheminée 12” (30,5cm)
DuraChimney II 8DCA-12
Section de cheminée 18”(45,7cm)
DuraChimney II 8DCA-18
Section de cheminée 24” (61cm)
DuraChimney II 8DCA-24
Section de cheminée 36” (91,4cm)
DuraChimney II 8DCA-36
Section de cheminée 48” (121,9cm)
DuraChimney II 8DCA-48
Ensemble de Coude 15°
DuraChimney II 8DCA-E15K
Ensemble de Coude 30°
DuraChimney II 8DCA-E30K
Sangle de Coude
DuraChimney II 8DCA-ES
Support Supplémentaire
DuraChimney II 8DCA-SS
Courroie Murale
DuraChimney II 8DCA-WS
Stabilisateur
DuraChimney II 8DCA-ST
Plaque d’ancrage
DuraChimney II 8DCA-AP
Coupe-feu
DuraChimney II 8DCA-FS
Coupe-feu Murale 30°
DuraChimney II 8DCA-FS30
Protecteur d’Isolation Grenier
DuraChimney II 8DCA-IS
Protecteur d’Isolation Toit
DuraChimney II 8DCA-RRS
Dessus de l’Enchâssure du Solin
DuraChimney II 8DCA-CTF
Dessus de l’Enchâssure du Collet
DuraChimney II 8DCA-CTC
Collet de Soin (6-8”)
DuraChimney II 8DCA-SC
Chapeau de Cheminée
DuraChimney II 8DCA-VC
Trappe à l’air
Wolf Steel NZAC8KT
INSTALLATEUR: Laissez ce manuel avec l’appareil.
PROPRIÉTAIRE: Conservez ce manuel pour consultation ultérieure.
1
2
Vous aurez besoin de:
Avec 5/16” et 1/4” Embout de Tournevis
Installez air logement, pour cheminée refroidie l’air a
l’appareil supérieur en utilisant 6 vis fournies.
Installez la plaque d’ancrage (utilisant le joint
d’étanchéité fourni avec l’appareil) et la première duré
de la cheminée.
NZAC8KT
Instructions d’Installation de la Cheminée Refroidie à l’Air NZ5000
X6
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfoyers.com
4
5
Installez 4” hotte extérieur à travers le mur. Fixation du
matériel et scellant pas fournis.
* Seulement 10 pieds de d’évent flexible d’aluminium est inclus, pour plus grandes longueurs, contactez votre détaillant agréé de
Napoléon.
X3
Enfoncer et verrouiller 4 “ d’évent flexible d’aluminium
à col de l’air de logement. Route à la hotte et fixez
avec 3 vis par connexion.
W415-2251 / 08.24.17
0
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
5
(10)
10
(20)
15
(30)
20
(40)
25
(50)
GAINES DE LA PRISE D’AIR
COURSE HORIZONTALE
ÉLÉVATION VERTICALE
La course horizontale peut mesurer :
5' (1,5m)
15' (4,6m)
20' (6,1m)
25' (7,6m)
La course verticale mesure entre :
6' (1,8m) et 10' (3m) max.
3' (0,9m) et 3' (0,9m)
0' (0m) et 1' (0,3m)
GAINES D’ÉVENT
FLEXIBLE
Installez le plaque du collet de 12¼” au-dessus de la
cheminée avec les 4 vis fournies.
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

NAPOLEON NZ5000 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages