Shure UNISPHERE I 565 Series User manual

Category
Microphones
Type
User manual
GENERAL
The UNISPHERE I 565 Series microphones are dual-im-
pedance, unidirectional dynamic microphones with a strong,
wire-mesh, spherical front grille that contains a highly effective
wind and “pop“ filter.
Shipped connected for low-impedance operation, 565 Se-
ries microphones provide excellent vocal or speech reproduc-
tion on lecterns and stages, and are a popular choice for use in
public auditoriums, churches, convention halls, and schools.
FEATURES
S Selectable dual impedance operation
S Silent magnetic reed on/off switch with lock-on option
S Cardioid dynamic
S Frequency response: 50 to 15,000 Hz
MODEL VARIATIONS
Model 565SD-CN: Supplied with 6.1 m (20 ft) XLR cable.
Model 565SD-LC: No cable supplied.
CONNECTIONS
When using the microphone with a balanced input, pins 2
and 3 are the audio signal carriers. When using the microphone
with an unbalanced input, use a cable wired with pin 2 as the sig-
nal carrier and pin 3 connected to the cable shield (ground),
such as the Shure C20HZ high-impedance cable.
IMPEDANCE SELECTION
The microphone is shipped connected for low impedance
operation. To change to high impedance, proceed as follows
(refer to Figure 1):
1. Remove plug element at receptacle end of microphone by
turning slotted setscrew in (counterclockwise) and carefully
withdrawing plug element from case.
2. Disconnect 2-terminal impedance selection socket from
rear of plug element.
3. Reconnect 2-terminal impedance selection socket in re-
verse position so that pin 3 of plug element is inserted in
socket terminal “H” (White).
4. Reassemble plug element into microphone and seal set-
screw securely by turning out (clockwise).
IMPEDANCE
SELECTION SOCKET
PLUG
ELEMENT
SET SCREW
PIN 3
IMPEDANCE SELECTION—
RECEPTACLE END OF MICROPHONE
FIGURE 1
POLARITY
All cables and microphones should be tested to ensure
that they have the same polarity. To test two microphones
and/or their cables for proper polarity, connect them to an ampli-
fier and talk or sing into them while holding them three or four
inches apart. The sound from the speakers should be the same
when talking into either microphone or directly between them.
If the sound drops drastically, or if a dead spot is found when
talking between the two microphones, either the microphones
or their cables have opposite polarity.
To change the polarity of a microphone cable, either use
a Shure A15PRS phase reverser or interchange the wires con-
nected to pins 2 and 3 of the three-pin connector at one end of
the cable. To change the polarity of a microphone, the micro-
phone cartridge leads must be interchanged. This should be
performed by your dealer, the Shure Factory Service Depart-
ment, or other qualified service personnel.
SPECIFICATIONS
Type
Dynamic
Frequency Response
50 to 15,000 Hz (see Figure 2)
Polar Pattern
Cardioid (unidirectional)—uniform with frequency, sym-
metrical about axis (see Figure 3)
lmpedance
Dual. Microphone rating impedance is 150 ohms (250
ohms actual) for connection to microphone inputs rated
at 19 to 300 ohms and “High” for connection to high-im-
pedance microphone inputs.
Wired for low impedance as supplied. To change impe-
dance, see sections on lmpedance Selection and Con-
nections.
Output Level (at 1,000 Hz)
“L”
“H”
Open Circuit Voltage* –56.0dB –34.0 dB. . . . . . . . .
(1.6 mV) (20 mV)
*0 dB = 1 volt per Pascal (1 Pa = 94 dB SPL)
Model 565SD User Guide
27B3060 (CG)
2003, Shure Incorporated
Printed in U.S.A.
20 200001000 1000050 100
98765432
98765432
+10
0
–10
Hz
dB
TYPICAL FREQUENCY RESPONSE
FIGURE 2
150
o
120
o
150
o
120
o
180
o
30
o
60
o
90
o
30
o
60
o
90
o
–5 dB
–10 dB
–15 dB
–20 dB
0
150
o
120
o
150
o
120
o
180
o
30
o
60
o
90
o
30
o
60
o
90
o
–5 dB
–10 dB
–15 dB
–20 dB
0
125 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
TYPICAL POLAR PATTERNS
FIGURE 3
CARTRIDGE TRANSFORMER XLR CONNECTOR
CODED TERMINAL
IMPEDANCE SELECTION SOCKET
(SHOWN IN LOW IMPEDANCE POSITION)
REED
SWITCH
GREEN
BLACK
YELLOW
GREEN
YELLOW
RED
BLUE
WHITE
BLACK
INTERNAL CONNECTIONS
FIGURE 4
(2 in.)
51 mm
161 mm
(6 7/16 in.)
23 mm
(15/16 in.)
22 mm
(7/8 in.)
93 mm
(3 11/16 in.)
OVERALL DIMENSIONS
FIGURE 5
34 mm
(1 11/32 in.)
2
Polarity
Positive pressure on diaphragm produces positive volt-
age on pin 2 (with respect to pin 3). See Figure 4.
Switch
Built-in magnetic reed on/off switch with lockplate. To
lock switch in the ON position, remove screw on
lockplate and turn lockplate 180_. Reassemble and tight-
en screw.
Cartridge Shock Mount
Internal rubber vibration-isolator
Cable
565SD-CN: 6.1 m (20 ft) two-conductor shielded, rubber-
jacketed, detachable, with XLR connectors.
Swivel Adapter
Positive action, adjustable through 90_ from vertical to
horizontal, permits easy removal for handheld use, suit-
able for mounting on stand with
5
/
8
”–27 thread
Case
Chrome-plated die casting with steel mesh grille
Dimensions
See Figure 5
Net Weight (less cable)
298 grams (10
1
/
2
oz)
CERTIFICATIONS
Eligible to bear CE Marking. Conforms to European EMC
Directive 89/336/EEC. Meets applicable tests and perfor-
mance criteria in European Standard EN55103 (1996) parts 1
and 2, for residential (E1) and light industrial (E2) environments.
FURNISHED ACCESSORY
Swivel Adapter A25D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REPLACEMENT PARTS
Cartridge R65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Screen and Grille RS65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug Element RK169P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONAL ACCESSORIES
Line Matching Transformer A95 Series. . . . . . . . . . . . . . . . .
Desk Stand S37A, S39A. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Isolation Mount A55M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Mount A26M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Windscreen A58WS Series. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable, LO–Z (7.6 m [25 ft]) C25J. . . . . . . . . . . . . . . . . . . . . . .
Cable, HI-Z (6.1 m [20 ft]) C20HZ. . . . . . . . . . . . . . . . . . . . . . .
ARCHITECTS’ SPECIFICATIONS
The microphone shall be a moving coil (dynamic) type with
a frequency response of 50 to 15,000 Hz. The unit shall have
a cardioid polar characteristic. The cancellation at the sides
shall be approximately 6 dB, and the cancellation at the rear
shall be 15 to 20 dB. The microphone shall be dual impedance
with a rated impedance of 150 ohms for connection to micro-
phone inputs rated at 19 to 300 ohms and “High” for connection
to high–impedance microphone inputs. lmpedance change
shall be solderless at the microphone connector.
The microphone output shall be:
Low lmpedance –56.0 dB. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(0 dB = 1 volt per Pascal)
High lmpedance –34.0 dB. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(0 dB = 1 volt per Pascal)
The microphone shall have an XLR, three–pin professional
audio connector and shall be equipped with a magnetic reed
On–Off switch.
The microphone shall be provided with a swivel adapter,
adjustable through 90_ from vertical to horizontal, and suitable
for mounting on a stand having a
5
/
8
”–27 thread.
The overall dimensions of the microphone shall be 162 mm
(6–
23
/
64
in.) in length and 51 mm (2 in.) in diameter.
The microphone shall be the Shure Model 565SD-LC,
565SD-CN, or equivalent.
SHURE Incorporated Web Address: http://www.shure.com
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
Phone: 800-257-4873 Fax: 847-600-1212
In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414
In Asia, Phone: 852-2893-4290 Fax: 852-2893-4055
Elsewhere, Phone: 847-600-2000 Fax: 847-600-6446
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Shure UNISPHERE I 565 Series User manual

Category
Microphones
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI