INSTRUCTION MANUAL
PAC-MD-WDRX22 (S46569)
Fastrax Mini-PTZ
CAMERA
Please read this manual thoroughly before use and keep it handy for future reference.
II
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO
NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO
NOT INSERT ANY METALLIC OBJECTS THROUGH THE
VENTILATION GRILLS OR OTHER OPENINGS ON THE
EQUIPMENT.
CAUTION
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
III
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC INFORMATION: This equipment has been tested and found to
comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.
CE COMPLIANCE STATEMENT
WARNING
This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
IV
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves,
or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or the
third prong is provided for your safety. If the provided plug does not fit into
your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
15. CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY
QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF
ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN
THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU
ARE QUALIFIED TO DO SO.
16. Use Certified/Listed Class 2 power source only.
17. Apparatus shall not be exposed to dripping or splashing and no object filled
with liquids, such as vases, shall be placed on the apparatus.
V
Table of Contents
Chapter 1 Introduction .................................................................................................. 1
1.1 Features ............................................................................................................................... 1
Chapter 2 Installation and Configuration .................................................................... 2
2.1 Package Contents ............................................................................................................... 2
2.2 Installation ........................................................................................................................... 3
2.3 Basic Configuration of Dome Camera System .................................................................. 6
2.4 Setting Dome Camera Termination .................................................................................... 7
2.5 Setting Dome Camera Address (ID) ................................................................................... 8
2.6 Setting Dome Camera Protocol, Baud rate and Video type ............................................ 15
2.7 Connections ....................................................................................................................... 16
2.8 Getting Started ................................................................................................................... 17
Chapter 3 Program and Operation ............................................................................. 18
3.1 Dome Camera Selection .................................................................................................... 18
3.2 Accessing the On-Screen Menu Utility ............................................................................ 18
3.3 How to control the On-Screen Menu Utility ..................................................................... 18
3.4 Auto Scan (Shortcut: SCAN) ............................................................................................ 19
3.5 Preset (Shortcut: PRST) ................................................................................................... 21
3.6 Shortcut of Preset Program .............................................................................................. 23
3.7 Tour (Shortcut: TOUR) ...................................................................................................... 23
3.8 Pattern (Shortcut: PTRN) .................................................................................................. 25
3.9 Alarm .................................................................................................................................. 26
3.10 Area Title .......................................................................................................................... 27
3.11 Privacy Zone .................................................................................................................... 28
3.12 Camera Menu ................................................................................................................... 29
3.13 Dome Setup ..................................................................................................................... 32
3.14 Dome Communication ..................................................................................................... 38
3.15 Function Run ................................................................................................................... 39
Appendix A Specifications ......................................................................................... 40
Appendix B Troubleshooting ..................................................................................... 42
Appendix C Glossary .................................................................................................. 42
Appendix D Short Cut Key ......................................................................................... 45
1
Chapter 1 Introduction
1.1 Features
The dome camera and the keyboard controller make up the building blocks for any
surveillance/security system. Using multiple keyboard controllers and multiple dome cameras, no
place is too large for monitoring. Extensible and flexible architecture facilitates remote control
functions for a variety of external switching devices such as multiplexers and DVRs.
Built-in optical power zoom camera with True Night Shot function
240 Preset positions with the individual Camera AE setup
8 Tours consist of Presets, Patterns, Auto Scans and other Tours can be programmed with over
300 functions and preset locations. While moving, each Preset scan can be watched in smooth
Vector Scan mode.
16 Auto Scans with the normal, the vector, and the random mode and the endless Auto-Pan with
13 speed steps
8 Patterns (up to 200 second) and 8 Privacy Zones
16 Area Titles
4 Alarm inputs, 1 Alarm output (5VTTL)
Variable speed from 0.1/sec to 380/sec
Three Variable speed (SLOW, NORMAL, TURBO)
Turbo speed is 380/sec with Ctrl key pressed.
Pan/Tilt speed is inversely proportional to the zoom ratio with the option.
Maximum speed is 380/sec when Preset command.
Auto Calibration from 0.1 to 6 (Tilt range is 0 to 180)
Programmable user preferences (alarm, preset, title, etc.)
180 Digital Flip
Up to 255 selectable camera addresses
Multi-language Menu Display, Password Confirmation
Function Run menu using DVR without function key (Pattern, Scan …)
Built-in RS-485 receiver driver
12VDC or 24VAC for Dome
Use Certified/Listed Class 2 power source only.
2
Chapter 2 Installation and Configuration
2.1 Package Contents
The dome camera is designed with compact, small size, hard dome camera housing. The housing
is constructed of aluminum, steel and plastic. The housing is designed to be mounted on a wall or
a ceiling. The housing meets the Protection Classification IP66 standards for dust and moisture
resistance.
* Dome Camera 1
* Instruction Manual (This Document) 1
* Template Sheet 1
* Mounting Bracket 1
* Safety Lanyard 1
* Accessory Kit 1
1) Mounting screws (PH6 x 35.0) (4)
2) Plastic anchors (4)
3) O-Rings (4)
4) Torx wrench (1)
* Accessory Connector 1
1) 3-Pin Terminal Block (1)
2) 2-Pin Terminal Block (2)
3) 5-Pin Terminal Block (1)
3
2.2 Installation
The dome camera is for use in surface or pendent mounting applications, and the mounting
member must be capable of supporting loads of up to 4.4 lb (2.0 kg). (Pendent mounting must use
pendent mount accessory.)
The dome camera’s mounting bracket should be attached to a structural object, such as hard wood,
wall stud or ceiling rafter that supports the weight of the dome camera.
CAUTION: A silicone rubber sealant must be applied to seal the housing to secure
waterproofing.
2.2.1 Locking Dome Camera
A. Make screw holes on the ceiling using the supplied mounting Template Sheet (Figure A).
B. Fix the Mounting Bracket to the ceiling using supplied Anchors (4x) and Mounting Screws (4x)
(Figure B).
C. Hook up the Safety Lanyard to the Safety Lanyard Hook of the Mounting Bracket (Figure C).
D. Align the locking tab on the bracket and the locking slot on the base of the dome (Figure D).
E. Turn the dome to the counterclockwise about 10 degree to the locked position (Figure E).
4
CAUTION 1: Before installing mounting bracket to surface pre-adjust the four mounting
screws "A" on the base of the dome camera to best match the mounting
bracket locked position. Unscrew the locking screw on the side of the dome's
base and fit the tab of the mounting bracket into the locking slot. Screws "A"
should not be too tight or too loose when the dome is in the locked position.
After setting the proper positions of screws "A" remove the mounting bracket
and install it to the proper surface. If it is too difficult to lock the dome in
position after the mounting bracket has been installed readjust the screws "A"
by unscrewing them a small amount and try to install dome camera again.
CAUTION 2: Set the termination and ID address of the dome before final installation as
described at 2.3 (figure 2), 2.4 and 2.5.
5
2.2.2 Heater Kit Installation
1. Assemble the Heater board to two bossed with screws.
Take a reference "B" in the bottom case as below.
2. Place the Heater in the slot "A".
Heater cable should be placed away from the Main Board.
3. Plug the power connector to the socket "C" (J1) of the Heater Board.
4. 24VAC is recommended to use for the camera power for stable operation with heater kit.
• HEATER (IF APPLICABLE)
Power Supply
24VAC
Power Consumption
10W
Heater ON
at 59°F (15°C)
Heater OFF
at 77°F (25°C)
• POWER
Use Certified/Listed Class 2 power source only.
CAUTION: Please reset the camera after 30 minutes when installing it in situations
colder than -10°C.
6
2.3 Basic Configuration of Dome Camera System
Figure 1 Basic Installation Diagram
The dome camera must be installed by qualified service personnel in accordance with all local and
federal electrical and building codes.
AC+
AC-
AC+
AC-
FGND
(Rx+)
(Rx-)
Rx(Tx)+
Rx(Tx)-
GND
7
Figure 2 Layout of DIP switches
NOTE: Open the switch cover (position “a”) and change the setting of DIP switches.
The cover should be closed after setting DIP switches.
2.4 Setting Dome Camera Termination
The device which is connected at end of line, whether it is a dome camera or keyboard controller,
must have the cable for communication terminated by setting the appropriate DIP switch.
Without proper termination, there is potential for control signal errors. Total length of the cable for
communication should not exceed 4000 ft (1.2 km).
S3
Figure 3 Setting Dome Camera Termination
S3
Terminated
Not terminated
8
2.5 Setting Dome Camera Address (ID)
To prevent damage, each dome camera must have a unique address (ID).
When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera
address match the multiplexer port number.
The factory default setting is 1.
• When COMMUNICATION MODE is set to S/W
Dome camera address (ID), Protocol and Baud rate can be used by selecting from the MENU.
You can call up the On-screen menu utility on your monitor by pressing MENU key on the
keyboard controller, the following On-screen menu utility will appear:
DOME MENU
AUTO SCAN
PRESET
TOUR
PATTERN
ALARM
AREA TITLE
PRIVACY ZONE
CAMERA
DOME SETUP
DOME COMMUNICATION
FUNCTION RUN
EXIT(ESC TO EXIT)
Scroll to DOME COMMUNICATION and push the Joystick to the right.
Select COMMUNICATION MODE and set the desired mode by twist the Joystick.
DOME COMMUNICATION SETUP
COMMUNICATION MODE: S/W
DOME ID : 001
PROTOCOL : AUTO
BAUDRATE : 9600
SAVE AND EXIT(ESC TO CANCEL)
For more information, see Chapter 3 Program and Operation for DOME COMMUNICATION.
NOTE: When COMMUNICATION MODE is set to S/W (Software), the H/W (Hardware) setting
is ignored.
• When COMMUNICATION MODE is set to H/W
Dome camera address (ID), Protocol and Baud rate can be used by selecting from the Hardware
using the DIP switches.
Refer to Figure 4.1 ~ 4.6 for setting the dome camera address (ID).
9
Example: Port 1 = Dome 1, Port 2 = Dome 2 … Port 16 = Dome 16. If more than 16 dome
cameras are installed using two or more multiplexers, ID of the dome camera should be ID of
MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )
S1
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
OFF
16
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
17
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
18
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
19
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
20
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
21
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
22
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
23
ON
ON
ON
OFF
ON
OFF
OFF
OFF
24
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
25
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
26
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
27
ON
ON
OFF
ON
ON
OFF
OFF
OFF
28
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
29
ON
OFF
ON
ON
ON
OFF
OFF
OFF
30
OFF
ON
ON
ON
ON
OFF
OFF
OFF
31
ON
ON
ON
ON
ON
OFF
OFF
OFF
32
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
33
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
34
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
35
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
Figure 4.1 Setting Dome Camera Address (ID)
10
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
36
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
37
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
38
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
39
ON
ON
ON
OFF
OFF
ON
OFF
OFF
40
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
41
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
42
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
43
ON
ON
OFF
ON
OFF
ON
OFF
OFF
44
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
45
ON
OFF
ON
ON
OFF
ON
OFF
OFF
46
OFF
ON
ON
ON
OFF
ON
OFF
OFF
47
ON
ON
ON
ON
OFF
ON
OFF
OFF
48
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
49
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
50
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
51
ON
ON
OFF
OFF
ON
ON
OFF
OFF
52
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
53
ON
OFF
ON
OFF
ON
ON
OFF
OFF
54
OFF
ON
ON
OFF
ON
ON
OFF
OFF
55
ON
ON
ON
OFF
ON
ON
OFF
OFF
56
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
57
ON
OFF
OFF
ON
ON
ON
OFF
OFF
58
OFF
ON
OFF
ON
ON
ON
OFF
OFF
59
ON
ON
OFF
ON
ON
ON
OFF
OFF
60
OFF
OFF
ON
ON
ON
ON
OFF
OFF
61
ON
OFF
ON
ON
ON
ON
OFF
OFF
62
OFF
ON
ON
ON
ON
ON
OFF
OFF
63
ON
ON
ON
ON
ON
ON
OFF
OFF
64
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
65
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
66
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
67
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
68
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
69
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
70
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
71
ON
ON
ON
OFF
OFF
OFF
ON
OFF
72
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
73
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
74
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
75
ON
ON
OFF
ON
OFF
OFF
ON
OFF
76
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
77
ON
OFF
ON
ON
OFF
OFF
ON
OFF
78
OFF
ON
ON
ON
OFF
OFF
ON
OFF
79
ON
ON
ON
ON
OFF
OFF
ON
OFF
80
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
Figure 4.2 Setting Dome Camera Address (ID)
11
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
81
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
82
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
83
ON
ON
OFF
OFF
ON
OFF
ON
OFF
84
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
85
ON
OFF
ON
OFF
ON
OFF
ON
OFF
86
OFF
ON
ON
OFF
ON
OFF
ON
OFF
87
ON
ON
ON
OFF
ON
OFF
ON
OFF
88
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
89
ON
OFF
OFF
ON
ON
OFF
ON
OFF
90
OFF
ON
OFF
ON
ON
OFF
ON
OFF
91
ON
ON
OFF
ON
ON
OFF
ON
OFF
92
OFF
OFF
ON
ON
ON
OFF
ON
OFF
93
ON
OFF
ON
ON
ON
OFF
ON
OFF
94
OFF
ON
ON
ON
ON
OFF
ON
OFF
95
ON
ON
ON
ON
ON
OFF
ON
OFF
96
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
97
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
98
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
99
ON
ON
OFF
OFF
OFF
ON
ON
OFF
100
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
101
ON
OFF
ON
OFF
OFF
ON
ON
OFF
102
OFF
ON
ON
OFF
OFF
ON
ON
OFF
103
ON
ON
ON
OFF
OFF
ON
ON
OFF
104
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
105
ON
OFF
OFF
ON
OFF
ON
ON
OFF
106
OFF
ON
OFF
ON
OFF
ON
ON
OFF
107
ON
ON
OFF
ON
OFF
ON
ON
OFF
108
OFF
OFF
ON
ON
OFF
ON
ON
OFF
109
ON
OFF
ON
ON
OFF
ON
ON
OFF
110
OFF
ON
ON
ON
OFF
ON
ON
OFF
111
ON
ON
ON
ON
OFF
ON
ON
OFF
112
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
113
ON
OFF
OFF
OFF
ON
ON
ON
OFF
114
OFF
ON
OFF
OFF
ON
ON
ON
OFF
115
ON
ON
OFF
OFF
ON
ON
ON
OFF
116
OFF
OFF
ON
OFF
ON
ON
ON
OFF
117
ON
OFF
ON
OFF
ON
ON
ON
OFF
118
OFF
ON
ON
OFF
ON
ON
ON
OFF
119
ON
ON
ON
OFF
ON
ON
ON
OFF
120
OFF
OFF
OFF
ON
ON
ON
ON
OFF
121
ON
OFF
OFF
ON
ON
ON
ON
OFF
122
OFF
ON
OFF
ON
ON
ON
ON
OFF
123
ON
ON
OFF
ON
ON
ON
ON
OFF
124
OFF
OFF
ON
ON
ON
ON
ON
OFF
125
ON
OFF
ON
ON
ON
ON
ON
OFF
Figure 4.3 Setting Dome Camera Address (ID)
12
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
126
OFF
ON
ON
ON
ON
ON
ON
OFF
127
ON
ON
ON
ON
ON
ON
ON
OFF
128
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
129
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
130
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
131
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
132
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
133
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
134
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
135
ON
ON
ON
OFF
OFF
OFF
OFF
ON
136
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
137
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
138
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
139
ON
ON
OFF
ON
OFF
OFF
OFF
ON
140
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
141
ON
OFF
ON
ON
OFF
OFF
OFF
ON
142
OFF
ON
ON
ON
OFF
OFF
OFF
ON
143
ON
ON
ON
ON
OFF
OFF
OFF
ON
144
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
145
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
146
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
147
ON
ON
OFF
OFF
ON
OFF
OFF
ON
148
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
149
ON
OFF
ON
OFF
ON
OFF
OFF
ON
150
OFF
ON
ON
OFF
ON
OFF
OFF
ON
151
ON
ON
ON
OFF
ON
OFF
OFF
ON
152
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
153
ON
OFF
OFF
ON
ON
OFF
OFF
ON
154
OFF
ON
OFF
ON
ON
OFF
OFF
ON
155
ON
ON
OFF
ON
ON
OFF
OFF
ON
156
OFF
OFF
ON
ON
ON
OFF
OFF
ON
157
ON
OFF
ON
ON
ON
OFF
OFF
ON
158
OFF
ON
ON
ON
ON
OFF
OFF
ON
159
ON
ON
ON
ON
ON
OFF
OFF
ON
160
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
161
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
162
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
163
ON
ON
OFF
OFF
OFF
ON
OFF
ON
164
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
165
ON
OFF
ON
OFF
OFF
ON
OFF
ON
166
OFF
ON
ON
OFF
OFF
ON
OFF
ON
167
ON
ON
ON
OFF
OFF
ON
OFF
ON
168
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
169
ON
OFF
OFF
ON
OFF
ON
OFF
ON
170
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Figure 4.4 Setting Dome Camera Address (ID)
13
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
171
ON
ON
OFF
ON
OFF
ON
OFF
ON
172
OFF
OFF
ON
ON
OFF
ON
OFF
ON
173
ON
OFF
ON
ON
OFF
ON
OFF
ON
174
OFF
ON
ON
ON
OFF
ON
OFF
ON
175
ON
ON
ON
ON
OFF
ON
OFF
ON
176
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
177
ON
OFF
OFF
OFF
ON
ON
OFF
ON
178
OFF
ON
OFF
OFF
ON
ON
OFF
ON
179
ON
ON
OFF
OFF
ON
ON
OFF
ON
180
OFF
OFF
ON
OFF
ON
ON
OFF
ON
181
ON
OFF
ON
OFF
ON
ON
OFF
ON
182
OFF
ON
ON
OFF
ON
ON
OFF
ON
183
ON
ON
ON
OFF
ON
ON
OFF
ON
184
OFF
OFF
OFF
ON
ON
ON
OFF
ON
185
ON
OFF
OFF
ON
ON
ON
OFF
ON
186
OFF
ON
OFF
ON
ON
ON
OFF
ON
187
ON
ON
OFF
ON
ON
ON
OFF
ON
188
OFF
OFF
ON
ON
ON
ON
OFF
ON
189
ON
OFF
ON
ON
ON
ON
OFF
ON
190
OFF
ON
ON
ON
ON
ON
OFF
ON
191
ON
ON
ON
ON
ON
ON
OFF
ON
192
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
193
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
194
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
195
ON
ON
OFF
OFF
OFF
OFF
ON
ON
196
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
197
ON
OFF
ON
OFF
OFF
OFF
ON
ON
198
OFF
ON
ON
OFF
OFF
OFF
ON
ON
199
ON
ON
ON
OFF
OFF
OFF
ON
ON
200
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
201
ON
OFF
OFF
ON
OFF
OFF
ON
ON
202
OFF
ON
OFF
ON
OFF
OFF
ON
ON
203
ON
ON
OFF
ON
OFF
OFF
ON
ON
204
OFF
OFF
ON
ON
OFF
OFF
ON
ON
205
ON
OFF
ON
ON
OFF
OFF
ON
ON
206
OFF
ON
ON
ON
OFF
OFF
ON
ON
207
ON
ON
ON
ON
OFF
OFF
ON
ON
208
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
209
ON
OFF
OFF
OFF
ON
OFF
ON
ON
210
OFF
ON
OFF
OFF
ON
OFF
ON
ON
211
ON
ON
OFF
OFF
ON
OFF
ON
ON
212
OFF
OFF
ON
OFF
ON
OFF
ON
ON
213
ON
OFF
ON
OFF
ON
OFF
ON
ON
214
OFF
ON
ON
OFF
ON
OFF
ON
ON
215
ON
ON
ON
OFF
ON
OFF
ON
ON
Figure 4.5 Setting Dome Camera Address (ID)
14
DOME ID
D1
(1)
D2
(2)
D3
(4)
D4
(8)
D5
(16)
D6
(32)
D7
(64)
D8
(128)
216
OFF
OFF
OFF
ON
ON
OFF
ON
ON
217
ON
OFF
OFF
ON
ON
OFF
ON
ON
218
OFF
ON
OFF
ON
ON
OFF
ON
ON
219
ON
ON
OFF
ON
ON
OFF
ON
ON
220
OFF
OFF
ON
ON
ON
OFF
ON
ON
221
ON
OFF
ON
ON
ON
OFF
ON
ON
222
OFF
ON
ON
ON
ON
OFF
ON
ON
223
ON
ON
ON
ON
ON
OFF
ON
ON
224
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
225
ON
OFF
OFF
OFF
OFF
ON
ON
ON
226
OFF
ON
OFF
OFF
OFF
ON
ON
ON
227
ON
ON
OFF
OFF
OFF
ON
ON
ON
228
OFF
OFF
ON
OFF
OFF
ON
ON
ON
229
ON
OFF
ON
OFF
OFF
ON
ON
ON
230
OFF
ON
ON
OFF
OFF
ON
ON
ON
231
ON
ON
ON
OFF
OFF
ON
ON
ON
232
OFF
OFF
OFF
ON
OFF
ON
ON
ON
233
ON
OFF
OFF
ON
OFF
ON
ON
ON
234
OFF
ON
OFF
ON
OFF
ON
ON
ON
235
ON
ON
OFF
ON
OFF
ON
ON
ON
236
OFF
OFF
ON
ON
OFF
ON
ON
ON
237
ON
OFF
ON
ON
OFF
ON
ON
ON
238
OFF
ON
ON
ON
OFF
ON
ON
ON
239
ON
ON
ON
ON
OFF
ON
ON
ON
240
OFF
OFF
OFF
OFF
ON
ON
ON
ON
241
ON
OFF
OFF
OFF
ON
ON
ON
ON
242
OFF
ON
OFF
OFF
ON
ON
ON
ON
243
ON
ON
OFF
OFF
ON
ON
ON
ON
244
OFF
OFF
ON
OFF
ON
ON
ON
ON
245
ON
OFF
ON
OFF
ON
ON
ON
ON
246
OFF
ON
ON
OFF
ON
ON
ON
ON
247
ON
ON
ON
OFF
ON
ON
ON
ON
248
OFF
OFF
OFF
ON
ON
ON
ON
ON
249
ON
OFF
OFF
ON
ON
ON
ON
ON
250
OFF
ON
OFF
ON
ON
ON
ON
ON
251
ON
ON
OFF
ON
ON
ON
ON
ON
252
OFF
OFF
ON
ON
ON
ON
ON
ON
253
ON
OFF
ON
ON
ON
ON
ON
ON
254
OFF
ON
ON
ON
ON
ON
ON
ON
255
ON
ON
ON
ON
ON
ON
ON
ON
Figure 4.6 Setting Dome Camera Address (ID)
15
2.6 Setting Dome Camera Protocol, Baud rate and Video type
If a dome camera is to be installed with the keyboard controller, select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S2
You can set video type with DIP switch.
Select video type with D1 in S2.
You can set Protocol with DIP switch D2, D3 and D4 in S2.
S2
PROTOCOL
D2
D3
D4
OFF
OFF
OFF
F2, F2E, Pelco-P, Pelco-D : default
OFF
OFF
ON
F2, F2E
OFF
ON
ON
Pelco-P, Pelco-D
You can set Baud Rate with DIP switch D5 and D6 in S2.
S2
BAUD RATE
D5
D6
OFF
OFF
2400 bps
OFF
ON
4800 bps
ON
OFF
9600 bps : default
ON
ON
19200 bps
Figure 5 Video type, Protocol, Baud rate Selection switches
S2-D1
VIDEO TYPE
OFF
NTSC
ON
PAL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

PACOM S46569 User manual

Category
Security cameras
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI