Xinje XP3-16R is a versatile device that combines PLC and HMI functionality. It features 8 input points, 8 output points, and a 3.7-inch display with 192x64 pixel resolution. With its integrated PLC, the XP3-16R can execute control programs and communicate with other devices using RS232/RS422/RS485 ports. The HMI interface allows users to monitor and modify PLC data, set parameters, and control automation processes. Additionally, the XP3-16R supports touch function and has 26 customizable function keys.

Xinje XP3-16R is a versatile device that combines PLC and HMI functionality. It features 8 input points, 8 output points, and a 3.7-inch display with 192x64 pixel resolution. With its integrated PLC, the XP3-16R can execute control programs and communicate with other devices using RS232/RS422/RS485 ports. The HMI interface allows users to monitor and modify PLC data, set parameters, and control automation processes. Additionally, the XP3-16R supports touch function and has 26 customizable function keys.

Doc Ref: LMAN007_R2V2
XP3-18RT
XP3-18R
8 Points Input, 8 Points Transistor/Relay/Mixed Output,
Integrated OP330 and XC3 Series PLC
2 Expansion Boards
Integrated PLC & HMI
10 Points/Optical Couple Isolated
192x64 Pixels, 3.7 inch Screen
Integrated PLC & HMI
10 Points/Optical Couple Isolated
192x64 Pixels, 3.7 inch Screen
XP3-16R/T/RT
XP3 SERIES PLC/HMI COMBINED UNIT MANUAL
XP3 PLC/HMI Hardware Manual Page 2 of 42 LMAN007_R2V2
XP3 PLC/HMI User Manual
IndexPage
Chapter 1 Summary
1-1 Function 3
1-2 Specs 4
1-3 Component parts 5
1-4 Button functions 6
1-5 MP series COM ports 7
1-6 Dimensions and installation 8
Chapter 2 Editing tool XP20
2-1 Summary 9
2-1-1 Edit tool installation/un-installation 9
2-1-2 Project 9
2-1-3 Screen content 9
2-1-4 Flow of XP20 10
2-2 Edit environments 10
2-2-1 Main screen 10
2-3 Component descriptions 11
2-4 Component properties 13
2-4-1 Text 13
2-4-2 True type text 14
2-4-3 Dynamic text 15
2-4-4 Dynamic true type text 26
2-4-5 Lamp 17
2-4-6 Bar 18
2-4-7 Register 19
2-4-8 Trend 20
2-4-9 Function key 21
2-4-10 Picture 23
2-4-11 Touch 24
2-5 System windows application 25
Chapter 3 Application of XP20 edit tool
3-1 Application flow 30
3-1-1 Create a new project 30
3-1-2 Add screens 31
3-1-3 Edit screens 31
3-1-4 Set system parameters 32
3-1-5 System passwords 32
3-1-6 Downloading the screen 33
Chapter 4 Using XP20 edit tool
4-1 Application of automatic control 34
4-1-1 Add and set screen property 34
4-1-2 Edit monitor screen 36
4-1-3 Edit parameter screen 38
4-1-4 Edit automatic screen 39
4-1-5 Edit manual screen 40
XP3 PLC/HMI Hardware Manual Page 3 of 42 LMAN007_R2V2
1Summary
The XP3 is an operator panel with touch function. Via text and indicator lamps, monitor or modify
the value and status of PLC’s internal register and relay. It has XP series operator panel’s
function, and at the same time it supports touch function.
XP3 has the following advantages:
The communication protocol will be downloaded to the model along with screen data.
Can connect with nearly all PLC’s popular in the current market, such as Mitsubishi FX
series,
Omron C series, Koyo SG series etc.
Password protection function
Alarm list function, real time display the current alarm information line by line.
26 function keys, each function key can be defined.
Choice of communication format, any one of RS232/RS422/RS485
Vector text and vector buttons.
Backlight STN LCD display, normally it can display 24 ASC×4 lines. If use the vector units, it
can display more information!
The display’s surface is IP65.
1-1 Function
1-2Specs
1-3Component parts
1-1Function
1-5MP series COM ports
1-6Dimensions and installation
1-4Button functions
XP3 PLC/HMI Hardware Manual Page 4 of 42 LMAN007_R2V2
1. Specification
Input Voltage 12V to 24V DC
Power Below 4W (TYP2.0W)
Momentary power cut
allowance Below 20ms
Voltage Endurance AC1000V -10mA for 1 minute
Insulation impedance DC500V - about 10M
2Ambient Condition
Operating temperature 0 to 50°C
Storage temperature –10 to 60°C
Ambient humidity 20 to 85% (No dew)
Vibration endurance 10 to 25Hz (X, Y, Z each direction 2G per 30 minutes)
Anti-interference Voltage noise: 1000Vp-p
Protection IP65
1-2 Specs
XP3 PLC/HMI Hardware Manual Page 5 of 42 LMAN007_R2V2
The direction keys select any screen and checks the screen status.
1-3 Component parts
Function
keys
LCD
display
Number
Keypad
Label
COM
port
XP3 PLC/HMI Hardware Manual Page 6 of 42 LMAN007_R2V2
Button Basic function
Return to initial screen. The initial screen is appointed by the user when
designing the screen (the default screen is number 1).
(It can also be used as a function key)
Page up
Page down
Select item to be modified
Write the modified data to the register.
Alarm list key (It can also be used as a function key).
Clear entry (It can also be used as a function key).
When modifying the register’s data, set the data positive or negative
(It can also be used and a function key).
Can use as global function key or normal function key
Common function keys F1 to F8
1-4 Button functions
XP3 PLC/HMI Hardware Manual Page 7 of 42 LMAN007_R2V2
PORT1 download port
[XP330]
PIN ID Definition
1 NC
2 RXD
3 TXD
4 NC
5 GND
6 NC
7 RTC
8 NC
9 NC
[XP330-S]
DP-SYS-CAB connection
DP210 Way PC9 Way
RXD 2 2 RXD
TXD 3 3 TXD
RTS 7 7 CTS
GND 5 5 GND
PIN ID Definition
1 TD+
2 RXD
3 TXD
4 Vacant
5 GND
6 TD-
7 Vacant
8 RD-
9 RD+
1-5 MP series COM ports
XP3 PLC/HMI Hardware Manual Page 8 of 42 LMAN007_R2V2
The cut-out size when installing:
Note:
1. The fixing screws shouldn’t be too tight to avoid damaging the panel.
2. The four fixing screws should be under equal pressure.
1-6 Dimensions and installation
164
113
XP3 PLC/HMI Hardware Manual Page 9 of 42 LMAN007_R2V2
2Editing tool XP20
2-1-1 Edit tool installation/un-installation
XP20 is the editing tool for XP series operator’s panels. It can run under Windows98/NT.
2-1-2 Project
All the screens are compiled are saved in one project. All the screens together are the application
project made by the designer.
2-1-3 Screen content
Using XP20.EXE, the user can create a new or edit an existing screen. Each screen can place
text, indicate lamp, switch, data display set window, screen jump key, bar diagram, bitmap
diagram, dynamic text etc. The operator can monitor data, parameter setting, switch control,
alarm list monitor etc.
2-1 Summary
2-2Edit environments
2-3Component descriptions
2-1Summary
2-4Component properties
2-5System window application
XP3 PLC/HMI Hardware Manual Page 10 of 42 LMAN007_R2V2
2-1-4 Flow of XP20
Basic programming flow of XP20:
2-2-1 Main screen
After running XP20 edit tool, there will be a screen shown below in the centre of the computer.
2-2 Edit environments
Open the editing tool
Create or open a project
Choose panel type
Choose PLC type
Edit the screen
Save the project
Download the screen
Run the panel
XP3 PLC/HMI Hardware Manual Page 11 of 42 LMAN007_R2V2
In the following, we describe some keys and their functions
Keys Functions
Create a new project
Open a saved project
Save the editing project
Cut the text in the display area
Copy the text in the display area
Paste the text in the display area
Create a new screen, it’s function is the same with [New]
Show the current screen’s attribution content
Copy a screen to another screen
Delete the current screen
Enter alarm list information, every piece of alarm information
corresponds with a middle relay
Assign the system’s initial screen. When the model is
working, press this key to return directly to the initial screen.
Generally the screen is the main menu screen to the screen,
which used mostly; Set the system’s password; Set the
alternate control register’s ID.
Set whole bureau function keys
Via computer’s RS232 port, download the edited project to
XP330 model.
2-3 Add and delete PLC types
XP3 PLC/HMI Hardware Manual Page 12 of 42 LMAN007_R2V2
The following are the 13 edit components.
Component Function
Text can input Chinese, English and some special signals.
Register, place data monitor window or data setting window (The object is PLC
data register)
Indicate lamp, show PLC’s internal middle relay’s ON/OFF status.
Function key, the 26 keys on XP330 can be all defined to be function keys. The
function key’s usage include screen jump and switch control etc.
Fold-line diagram, in industrial control diagram, some parameters change
slowly, the operator wants to know the parameter’s changing process, the fold-
line diagram is most ideal format
Bar diagram, bar diagram is used to display analog parameter directly, such as
flowpressureliquid level etc. Its height, width and direction can be assigned
freely.
Bit diagram, can display machine’s diagram, this make the operator easy to
understand, can also display factory Logo, factory badge to prompt the
products appearance.
Dynamic text, via dynamic text to display the machine’s status, this make the
operator easy to operate, improves the produce efficiency.
True type text (support all language), the size can be modified via the font
regulation. This makes the screen display more information. (Effective to
XP330).
Dynamic true type text (support all language). The function is the same with
dynamic text, add font modify property.
Data component, when this property is set ON, it supports touch function and
input.
Vector touch key. The size can be modified; it also has indicator lamp function.
XP3 PLC/HMI Hardware Manual Page 13 of 42 LMAN007_R2V2
2-4-1 Text
Press the key, there will be a rectangle moving with the mouse. Confirm were to place it via
the left-click on the mouse, right-click on the mouse to cancel. After you confirm, there will be a
text “Message” in the display area. Meanwhile, in the property area, its property will be shown.
Coordinate:
X: show the text’s horizontal direction.
Y: show the text’s vertical direction.
The origin dot’s direction is the most up-left dot in the whole area.
Special
Double: the horizontal and vertical direction both double display in times.
Inverse: inverse the color of the text and its background.
Text:
The real content can be displayed in English. This column can be cut, copy or paste.
Note:
To all units, they all have “coordinate” and “special” items. So in the following chapter, we will not
mention these two items.
2-4 Component properties
XP3 PLC/HMI Hardware Manual Page 14 of 42 LMAN007_R2V2
2-4-2 True type text
Press key, there will be a rectangle frame moving with your mouse. Confirm with your
mouse’s lef-click, cancel with your mouse’s right-click. After your confirmation, there will be a
message in the display area. Meanwhile, in the attribution area, display this text’s property. This
component is similar with “Text”. The difference is, “True type text” can modify the font and size.
Meanwhile, modifying the font can also modify the display area. This brings lots of flexibility for
the designer.
Coordinate:
X: show the text’s horizontal direction.
Y: show the text’s vertical direction.
The origin dot’s direction is the most up-left dot in the whole area.
Special:
Double: the horizontal and vertical direction both double display in times.
Inverse: inverse the colour of the text and its background.
Text:
The real display content. All can be displayed. This column can be cut, copy or paste.
XP3 PLC/HMI Hardware Manual Page 15 of 42 LMAN007_R2V2
2-4-3 Dynamic text
Click key, there will be a dashed frame moving with the mouse. Left-click the mouse to
confirm (right-click to cancel). After your confirmation, there will be a “Dynamic Message” in the
display area; meanwhile, its property will be shown in the property area. This icon is similar with
“Text”, the difference is: Dynamic text’s content is connected with a register. That is, when the
register’s value changes, the dynamic text with display the changed content.
Register:
PLC station ID: The device connected with this operate panel. When communicating with
different devices use different station ID. So, this station’s set value is different.
Usually we use the defaulted value.
Register ID: Set the register’s number, take the example of D0, the operator pan can
directly monitor value changing in D0.
Mode: data mode, normally you needn’t change.
Display:
Add the display content directly in the content column. When D0 is 1, it will display “manual
status”.
XP3 PLC/HMI Hardware Manual Page 16 of 42 LMAN007_R2V2
2-4-4 Dynamic true type text
Press key, add a dynamic true type text. There will be a defaulted “Dynamic Text” in the
display area. Meanwhile, in the property area its property will be shown. Dynamic True Type
Text is similar with Dynamic Text, the difference is: Dynamic True Type Text can change the
font and display area while Dynamic Text cannot. This makes the project more flexible
to design.
XP3 PLC/HMI Hardware Manual Page 17 of 42 LMAN007_R2V2
2-4-5 Lamp
Press key and place it in the display area. In the property area, you will see “Coil” and
“Display”. The lamp is used frequently in the project; it can be used as status indication, alarm
indication, or message indication etc.
Coil:
The lamps corresponding PLC station and coil number
Display:
Type: The lamp’s shape, including circle, square etc.
Positive:
When the middle relay is ON, the lamp will display solid; when the middle relay is OFF, the
lamp is hollow.
Negative:
When the middle relay is ON, the lamp will display hollow; when the middle relay is OFF, the
lamp is solid.
XP3 PLC/HMI Hardware Manual Page 18 of 42 LMAN007_R2V2
2-4-6 Bar
Click key and place it in the display area. The bar diagram is used to display directly
analogue parameters, such as level pressure liquid level, etc. Its height, width and direction
can be assigned freely.
Range:
The values determines the bar diagram’s width and height.
Register:
PLC station: The device’s address which connects with the operation panel
Register number: Use as sequence data storage area
Register number: Bar diagram’s corresponding register ID
Mode: Data format (include Decimal, HEX/BCD, signed etc)
Display:
Full value: The register’s corresponding value when the bar diagram 100% scale display.
Zero value: The register’s corresponding value when the bar diagram 0% scale display.
Direction: Bar diagram’s display direction can be Updown or left, right.
XP3 PLC/HMI Hardware Manual Page 19 of 42 LMAN007_R2V2
2-4-7 Text
Click key and place it in the display area. In a control system, the data operation is
necessary. So this “Register” places a key role in the control system.
Register:
Register number: Set this register’s number. Take D0 as the example, the panel can
directly monitor the changing of value in D0.
When choosing “Set”, then this register will also set function, there will be also
two items: Encrypt and low (up) limit.
Encrypt:
To improve the device’s safety, all the set parameters can be protected by the password.
For the password setting and modifying, please refer to the next chapter.
Up/Low limit:
The designer can set Up/low limit, this will make the data, which exceeds this limit, invalid.
This could protect the device when input too large or too low data. For example, when
setting the up value as 9000, the low value as 0. Only when its greater than 0 the set value
or below 9000, the set value could be written into the PLC.
Display:
Here, set the register’s display units and decimal bit, at the same time choose the
display mode.
XP3 PLC/HMI Hardware Manual Page 20 of 42 LMAN007_R2V2
Note:
When activating the register’s “Set”, it means this component has not only a monitor function but
also a set function.
2-4-8 Text
Click key and place it in the display area. Set its property in the property area. In industrial
control, some parameters change slowly. The operator wants to know how these parameters are
changing within a certain time. Choose the trend diagram to suit.
Range:
These values determine the trend diagram’s width and height.
Register:
PLC station: The device’s address, which connects with the panel.
Register number: Used as sequence data storage area.
Register ID: The trend diagram’s corresponding register address.
Mode: Data format (including Decimal, HEX/BCD, signed or not).
Register:
Full value: The register’s corresponding value with the trend diagram 100% scale display.
Zero value: Used as sequence data storage area.
Zero value: Used as sequence data storage area .
Register ID: The trend diagram’s corresponding register address.
Mode: Data format (including Decimal, HEX/BCD, signed or not).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

Xinje XP3-16R User manual

Type
User manual
This manual is also suitable for

Xinje XP3-16R is a versatile device that combines PLC and HMI functionality. It features 8 input points, 8 output points, and a 3.7-inch display with 192x64 pixel resolution. With its integrated PLC, the XP3-16R can execute control programs and communicate with other devices using RS232/RS422/RS485 ports. The HMI interface allows users to monitor and modify PLC data, set parameters, and control automation processes. Additionally, the XP3-16R supports touch function and has 26 customizable function keys.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI