General International 10-550 M1 Installation guide

Type
Installation guide
BEFORE CONNECTING THE AIR FILTRATION SYS-
TEM TO THE POWER SOURCE CHECK THAT THE
SUPPLIED VOLTAGE CORRESPONDS TO THAT
SPECIFIED ON THE NAMEPLATE OF THE MACHINE.
A POWER SOURCE WITH GREATER VOLTAGE
THAN NEEDED CAN RESULT IN SERIOUS INJURY
TO THE USER AS WELL AS DAMAGE THE MACHINE.
IF IN DOUBT, CONTACT A QUALIFIED ELECTRI-
CIAN BEFORE CONNECTING TO THE POWER
SOURCE.
GROUNDING INSTRUCTIONS
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN,
grounding provides a path of least resistance for elec-
tric current and reduces the risk of electric shock. This
tool is equipped with an electric cord that has an
equipment-grounding conductor and a grounding
plug. The plug MUST be plugged into a matching
receptacle that is properly installed and grounded in
accordance with ALL local codes ad ordinances.
DO NOT MODIFY THE PLUG PROVIDED.
If it will not fit the receptacle, have the proper recepta-
cle installed by a qualified electrician.
This tool is intended for use on a circuit that has a recep-
tacle like the one illustrated in Figure . Figure
shows a 3-prong electrical plug and receptacle that
has a grounding conductor. If a properly grounded
receptacle is not available, an adapter (Figure ) can
be used to temporarily connect this plug to a 2-contact
grounded receptacle. The temporary adapter should
be used only until a properly grounded receptacle can
be installed by a qualified technician. The adapter
(Figure ) has a rigid lug extending from it that MUST
be connected to a permanent ground, such as a pro-
perly grounded receptacle box. The Canadian Electri-
cal Code prohibits the use of these adapters.
IMPROPER CONNECTION of the equipment-grounding
conductor can result in risk of electric shock. The con-
ductor with green insulation (with or without yellow
stripes) is the equipment-grounding conductor. If repair
or replacement of the electric cord or plug is neces-
sary, DO NOT connect the equipment-grounding con-
ductor to a live terminal.
ELECTRICAL REQUIREMENTS
In all cases, make certain the receptacle is pro-
perly grounded. If you are not sure, have a quali-
fied electrician check the receptacle.
This machine is for indoor use only. Do not expose
to rain or use in damp locations.
This machine must be grounded while in use to
protect the operator from electrical shock.
CHECK with a qualified electrician or service person if
you do not completely understand the grounding
instructions or if you are not sure the tool is properly
grounded.
EXTENSION CORDS
If an extension cord is used, use only 3-wire extension
cords which have 3-prong grounding type plugs and
matching receptable which will accept the machine’s
plug.
5
LIST OF CONTENTS
QTY
AIRCLEANER.............................1
RUBBERFEET .............................4
5/16 - 18 FLANGE NUTS ....................4
5/16 - 18 x 1 1/2” EYE-BOLTS ................4
REMOTE CONTROL (REQUIRES 2 AAA BATTERIES - NOT SUPPLIED) .1
“PRO TURBO” AIR CLEANING SYSTEM
10-550
UNPACKING&SET-UP
FOR YOUR OWN SAFETY, DO NOT CONNECT THE
MACHINE TO A POWER SOURCE UNTIL YOU HAVE
READ AND UNDERSTOOD THIS MANUAL AND ALL
SAFETY AND OPERATING INSTRUCTIONS.
ADDITIONAL REQUIREMENTS FOR SET-UP
UNPACKING
Carefully unpack and remove the unit and its compo-
nents from the box and check for missing or damaged
items as per the list of contents below.
Note: Report any missing or damaged items to your
General International distributor immediately.
Note: For ceiling mount installation, extra hardware
such as mounting hooks, rope, or chain (not included)
may be required.
• Adjustable Wrench
• Large Flat-Head Screw Driver
• Extra Person for Help with Lifting
BASIC FUNCTIONS OF THIS UNIT
The model 10-550 “PRO TURBO” air cleaner is designed to quietly and efficiently filter non-metallic airborne dust par-
ticles in the workshop. This unit is not a woodworking dust collector, but when used in conjunction with an adequate
and properly connected dust collector, this air cleaner can help to reduce the risks and health hazards associated
with airborne dust particles in the workshop and contribute to a cleaner, safer work environment for the user.
6
This machine is not designed to function as a replacement for a woodworking dust collector. A woodworking dust
collector is connected, normally via a dust hose, to woodworking machinery and draws sawdust and woodchips
directly from the source (such as a blade, bit or cutting tool) – this is a different and separate operation from the
one performed by this machine.
The 2-stage filtration system includes a high efficiency inner 3-pouch filter that can capture up to 85% of airborne
dust particles as small as 1 micron, and an outer pleated filter that can capture up to 98% of airborne dust particles
as small as 5 microns.
With a rated air movement capacity of 800 cubic feet per minute this unit will re-circulate and filter all of the air in
a 15’ x 20’ x 8’ room up to 20 times per hour.
Featuring continuous run or timer operation, including 1-15 hour timer settings, the unit can be programmed to run
and continue to filter dust particles that are suspended in the ambient air in the workshop for up to 15 hours (in
1 hour increments), after you have completed your work in the shop.
The 10-550 Pro Turbo air cleaner can be either ceiling mounted (additional hardware may be required) or set on a
table, workbench or floor.
THIS UNIT IS NOT DESIGNED TO REPLACE PERSONAL BREATHING PROTECTION DEVICES SUCH AS RESPIRATORS OR
DUST MASKS.
TO ENSURE YOUR PERSONAL PROTECTION YOU MUST CONTINUE TO USE PERSONAL BREATHING PROTECTION
DEVICES WHENEVER RECOMMENDED FOR THE OPERATION OR WORK BEING PERFORMED.
THE 10-550 PRO TURBO AIR CLEANER IS DESIGNED TO CAPTURE SOLID, DRY, NON-METALLIC AIRBORNE DUST PARTI-
CLES ONLY. IT IS NOT DESIGNED (AND CANNOT BE RETRO-FITTED) TO FILTER OR PROTECT THE USER FROM PAINT
FUMES OR OVERSPRAY, NOXIOUS, HAZARDOUS, OR HARMFUL CHEMICAL FUMES, VOLATILE ORGANIC COMPOUNDS
(V.O.C’S), OR FOUL, UNPLEASANT OR HARMFUL ORDERS.
PREPARATION & INSTALLATION BEFORE USING
CARRYING & HANDLING THE UNIT
The air cleaner weighs 68 LBS (approximately 31 kg) and can
be carried using the two lifting handles inset on the sides of the
cabinet.
Whenever lifting or carrying the air cleaner, do so with the filters
positioned away from the body to avoid damaging the filters
through unintentional contact with belt buckles and zippers.
Fig. 1
Handle
REMOVING THE STYROFOAM BLOCKS
To help protect the interior components from damage during
transportation, styrofoam blocks were inserted at the factory,
above and below the fan housing inside of the cabinet.
BEFORE PLUGGING IN AND USING THE AIR CLEANER THESE
STYROFOAM BLOCKS MUST BE REMOVED.
Fig. 2
7
1. Make sure the air cleaner is not connected to a power
source.
2. Remove the Outer “Pleated” Filter by slightly lifting then pul-
ling the filter out at an angle. (Fig. 3)
Do the same for the Inner “Three Pouch” Filter.
3. Remove the two styrofoam blocks. (Fig. 4)
4. Reinstall the the Inner “Three Pouch” Filter making sure
pouches are pointing towards the FRONT (torwards the con-
trol panel) of the air cleaner.
Do the same with the Outer “Pleated” Filter; make sure to
install the filter with the airflow arrow pointing towards the
FRONT (towards the control panel) of the air cleaner.
(Fig. 3.1)
FAILURE TO REMOVE THE STYROFOAM BLOCKS MAY CAUSE DAMAGE TO THE MACHINE AND/OR BODILY HARM.
INSTALLING THE RUBBER FEET
If you plan to use this unit on a flat surface (floor, table, work-
bench etc…), rather than ceiling mounted, the 4 supplied
foam-rubber feet will help absorb vibration and reduce noise.
1. Carefully place the air cleaner upside down on a solid flat
surface.
2. Peel off the adhesive backing and apply one rubber foot to
each corner on the underside of the machine. (Fig. 5.1)
3. Set the air cleaner on a flat stable surface with at least 3 FT
(1 m) of unobstructed clearance front and back to allow
for adequate airflow. (Fig. 5)
1. Lift up.
2. Angle and
pull down.
1
2
Fig. 4
Fig. 3
Fig. 3.1
Fig. 5
Fig. 5.1
3FT
Front
3FT
Rear
OVERHEAD / CEILING MOUNT INSTALLATION
THE AIR CLEANER WEIGHS 68 LBS (APPROXIMATELY 31 KG),
FOR OVERHEAD/CEILING MOUNTING MAKE SURE THAT THE
MOUNTING SURFACE IS ADEQUATE AND CAN FULLY SUP-
PORT THE WEIGHT. NEVER MOUNT THE AIR CLEANER TO
DRYWALL, SUSPENDED CEILING TILES, OR NON-STRUCTURAL
MEMBERS.
ATTACHING THE EYEBOLTS TO THE AIR CLEANER
1. Unscrew the 4 screws installed on the top of the cabinet.
(Fig. 6)
2. Thread a flange nut onto each of the eye-bolts as shown. (Fig. 7)
8
Fig. 6 Fig. 7 Fig. 7.1
3. Screw an eye-bolt into each of the threaded holes in the top
of the cabinet. Make sure the eye-bolts are threaded at least
eight complete turns into the air cleaner.
4. Tighten the flange nuts down against the top of the cabinet
as shown in Fig. 7.1.
5. Hang overhead or to the ceiling. An example of a typical
ceiling mount installation is shown in Fig. 8. Always use
mounting hardware that has a rated weight capacity of at
least 3 times the weight of the machine (68 LBS) and ensure
that any mounting hooks or fasteners that are used are pro-
perly secured to a structural member such as a beam or
joist.
Note: Make sure to always tighten the flange nuts down against the
surface of the air cleaner after making any height adjustments.
Note: Check the eyebolts and/or flange nuts periodically to make
sure they have not loosened. If so, retighten the eyebolts and/or
flange nuts.
OPERATION
Note: During initial operation the air cleaner may produce a slight odor which will dissipate after a few hours of use.
NEVER OPERATE THE AIR CLEANER UNLESS BOTH AIR FILTERS ARE PROPERLY INSTALLED IN THE MACHINE.
OPERATING THE INLINE ON/OFF SWITCH
The unit is equipped with an inline ON/Off switch located on the
power cord (Fig #9). To allow electrical current to flow into the
machine, plug in the power cord to an appropriate outlet, and
press the inline switch to the “On” position. Note: If desired, with
the switch on the main control panel (Fig #10) in the “On” posi-
tion you can start or stop the machine by using the inline switch
on the power cord.
OPERATING THE CONTROL PANEL
With the unit plugged into an appropriate outlet and the inline switch on the power cord (Fig #9) in the “On” posi-
tion, the power indicator light “PWR” (Fig. #10 – ) will light up, indicating the electrical current is flowing into the
machine.
The main On/Off button (Fig. #10 – ) on the control panel is used to turn the air cleaner on or off. When the unit is
on, the “Run” indicator (Fig. #10 – ) will also light up.
With the unit turned on in “Run” mode, pressing the “Timer” button (fig. #10 ) activates the timer.
Note: the timer feature can only be activated when the unit is
turned on with the “Run” indicator lit. When the “Timer” button is
pressed once, the air cleaner will run for 1 hour. You can increase
the programmed run time, in 1 hour increments, with each succes-
sive push on the timer button.
When operating in timer mode, the appropriate timer indicator
light, or combination of lights, (Fig. #10 – ) will light up to show
the total number of hours for which the machine is set to run. The
machine will automatically stop running at the end of this pro-
grammed time period.
If desired, to cancel the timer setting before the completion of
the programmed time period, simply turn the unit off, using
either the main On/Off switch on the control panel or the inline
switch on the power cord.
Fig. 9
Fig. 8
Threaded
Mounting Hook
or Threaded
Eye-Bolt
Ceiling Joist
or Beam
Ceiling
ChainorRope
Fig. 10
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

General International 10-550 M1 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI