© 2010 Pentair Water Pool and Spa, Inc. All rights reserved - EQ Series®, Pentair Water Commercial Pool and
Spa™ is a trademark and/or a registered trademark of Pentair Water Pool and Spa, Inc. Unless noted, names and
brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the
proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those parties or others. Technical Support: (800) 831-7133
P/N 351138 Rev A (06-02-10)
3. Insert the dowel pins on the alignment tool into the dowel pin holes on the motor adapter (Figure 3).
4. Ensure that dowels are vertically oriented and the alignment notch is on the bottom (Figure 1).
5. Secure the motor adapter to the motor using the four screws (10) and washers (8)(9) (See Replacement
Parts page of the EQ Series® pump Installation and User’s Guide).
Step 3: Reassemble the pump: Assemble the pump as described in the EQ Series® Pump Installation and
User’s Guide (P/N 350061).
Figure 3