Polargos SIMPLE MOVE 102 Operating instructions

  • Hello! I'm your chat assistant, and I've reviewed the Installation and operation guide for the POLARGOS SIMPLE MOVE 102 gate opener. This document provides comprehensive instructions on how to safely install, configure, and operate your gate system. We can discuss topics such as the self-learning process, programming remote controls, setting various parameters, wiring accessories, and troubleshooting. Please feel free to ask any questions about the SIMPLE MOVE 102 you may have.
  • What should I do if the gate is open after self-learning is complete?
    How do I activate the pedestrian entry mode?
    How do I set the gate to slow speed?
www.polargos.pl
SIMPLE MOVE 102
EN Installation and operation guide
1
EN – Installation and operation guide SIMPLE MOVE 102
EN
Table of contents
Safety precautions 3
Product description 12
-Contents of the complete kit 12
-Dimensions 13
-Scope of application 13
-General overview of the installation 13
-Presentation of the electronic control system 14
Prerequisites for installation 15
-Gate inspection 15
-Stops on the ground 15
-Drive unit location 15
-Preliminary electrical system 15
-Required conductors 16
-Vertical setting 17
-Concrete foundations 17
- Tools required for assembly (not provided) 18
1 Assembly 19
1.1 Screw assembly 19
1.2 Drive fastening 19
1.3 Toothed bar installation 20
1.4 Mechanical adjustment 22
1.5 Drive wiring 23
1.6 Connecting to the 230 V power supply 24
1.7 Earthling of the electronic control system 25
1.8 Position of the electronic control system antenna 25
2 Start-up and standard use 26
2.1 Turning the installation on 26
2.2 Gate track self-learning 26
2.3 Standby / reactivation of the electronic control
system 27
2.4 Plugging the holes 27
2.5 Shield assembly 27
2.6 Complete opening and closing of the gate 28
2.7 Obstacle detection 28
3 Accessories wiring 29
3.1 Photocells (optional) 29
3.2 Orange light (optional) 29
3.3 Battery (optional) 30
3.4 Independent antenna (optional) 30
3.5 Video door phone (optional) 31
3.6 Key switch (optional) 31
3.7 Zone lighting (optional) 31
3.8 Solar energy power supply (optional) 32
4 Advanced parameter settings 33
4.1 Opening for pedestrian entry 33
- Operation of opening for pedestrian entry 33
- Activating of opening for pedestrian entry 33
- Deactivating of opening for pedestrian entry 33
4.2 Automatic closing 34
- Automatic closing operation 34
- Enabling automatic closing 34
- Deactivating automatic closing 35
4.3 Gate opening speed 36
- Scope of application 36
- Setting slow speed 36
- Setting slow speed (continued) 37
- Returning to standard speed 37
5 Programming the remote controls 38
55.1 Presentation of the remote controls 38
- Possibilities for programming
the 2-button remote control 38
- Possibilities for programming
the 4-button remote control 39
- Use of the 3-button remote control 39
5.2 Adding a remote control 40
- 2 or 4-button remote control 40
- 3-button remote control 40
5.3 Deleting a remote control 40
6 Troubleshooting 41
6.1 Support 41
6.2 Replacing the remote control battery 41
6.3 Deleting of settings 42
6.4 Diagnostics 43
7 Technical speci cations 44
2 3
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Please read the safety instructions below very carefully as well as the
installation and operation guide before installation and use of this product.
This symbol indicates a risk, the di erent degrees of which are described
below.
DANGER
Indicates a risk which could result in immediate death or serious injury.
WARNING
Indicates a risk which could result in death or serious injury.
CAUTION
Indicates a risk which could result in a minor or moderate injury.
IMPORTANT
Indicates a danger which could result in damage to or destruction of the product.
DANGER
The drive unit must be installed and adjusted by a professional mechanical equipment and
home automation installation engineer, in compliance with the regulations of the country,
where it is to be used. To meet the requirements of standards EN 13241-1, EN 12445 and
EN 12453, the installation engineer must follow the instructions in this guide throughout
the installation procedure. Failure to follow these instructions could result in serious
injury, e.g. being crushed by the gate.
WARNING
INFORMATION ABOUT RISKS – Important safety instructions. For reasons of personal
safety, it is extremely important to follow all the instructions, as incorrect installation
can lead to serious injury. Retain these instructions.
The installation engineer must train all users to ensure the drive unit is used in
a completely safe manner, in accordance with the operating manual.
The installation and operation guide as well as the safety instructions must be given
to the end user. Installation, adjustment and maintenance of the drive unit must be
performed by a professional mechanical devices and home automation installation
engineer.
4 5
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
1. Important information
This drive unit is compliant with EN 60335-2-103. These instructions are, above all,
designed to meet the requirements of the aforementioned standards, thus ensuring
the safety of people and property.
WARNING
Any use of this product outside the scope of application described in this guide is
prohibited (see the “Scope of application” paragraph in the manual).
The use of any accessories or any components not recommended by Polargos is
prohibited because they could pose a threat to users.
Polargos will not be liable for any damages resulting from failure to follow the
instructions in this guide.
If there are any doubts when installing the drive unit or to obtain additional information,
please visit the website www.polargos.pl.
These instructions may be modi ed in case of a change to the standards or parameters
of the drive unit.
2. Condition of the gate, for which the drive unit is intended
Before installing the drive unit, please check whether:
the gate is in good technical condition
the gate is correctly balanced
the structures supporting the gate are strong enough to allow the robust mounting
of the drive unit.
the gate can be opened and closed manually in a correct manner using a force less
than 150 N.
IMPORTANT
Do not pour water onto the drive unit.
Do not install the drive unit where there is a risk of explosion.
3. Electrical installation
DANGER
The installation of the power supply must comply with the standards in force in the
country, where the drive unit is to be installed, and must be carried out by quali ed
personnel.
DANGER
The electrical system must be designed exclusively for the drive unit and equipped
with a protection, comprising of the following components:
a fuse or circuit breaker of 10 A;
and a di erential-type device (30 mA).
Multipolar disconnection of the power supply is to be provided.
It is recommended to install a lightning conductor (mandatory maximum residual
voltage of 2 kV).
4. Laying conductors
Cables laid underground must be equipped with a protective sheath with a su cient
diameter to contain the drive conductor and the wiring accessories.
Low-voltage conductors subject to weather conditions must be at least H07RN-F type.
For the cables not laid underground, use a cable grommet that will withstand the
weight of passing vehicles.
5. Safety instructions regarding assembly
DANGER
Do not connect the drive unit to a power supply (mains, a battery, or a solar set) until
the assembly is complete.
WARNING
Make sure that danger zones (crushing, cutting, trapping) between the driven part
and the surrounding xed elements related to the opening movement of the driven
part have been eliminated.
WARNING
Changing any element provided in this kit or using any additional element not
recommended in this guide is strictly prohibited.
Monitor the gate opening or closing and keep all people at a safe distance until the
assembly is complete.
6 7
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Do not use adhesives to mount the drive unit.
WARNING
Manual unlocking may result in uncontrolled movement of the gate.
Place the sticker indicating the manual unlocking mechanism near the component
used for quick start-up.
IMPORTANT
Install xed control devices at a height of at least 1.5 m and within sight of the gate
but away from moving parts.
A er installation, make sure that:
the mechanism is properly adjusted;
the manual unlocking mechanism works correctly;
the drive unit reverses operation direction when the gate encounters a 50-mm
obstacle that is halfway up the gate leaf.
WARNING
For gate operation in automatic mode or if the control device is out of sight, photocells
must be installed.
The automatic drive unit must operate in at least one direction with no intentional
activation by the user.
For gate operation in automatic mode or if the gate opens onto a public road, installation
of an orange light may be required in accordance with the regulations in the country,
where the drive unit is installed.
6. Clothing recommendations
Take o any jewellery (a bracelet, chain, etc.) during assembly.
When executing any activities as well as drilling and welding operations, wear
appropriate protection (special protective glasses, gloves, ear protectors, etc.).
7. Safety instructions regarding operation
WARNING
This drive unit may be used by children aged 8 and over and by persons, whose
physical, sensory or mental capacity is impaired, or persons with no experience or
knowledge, as long as they are under proper supervision or have received proper
instructions on the safe use of the equipment and have been informed about possible
hazards. Children should not play with the drive unit. Children are not allowed to
perform cleaning and maintenance works, for which the user is responsible.
The sound pressure level of the drive unit is less than or equal to 70 dB (A). The noise
emitted by the structure, to which the drive unit will be connected, is not taken into
account.
WARNING
Every potential user must be informed by the installation engineer about the rules of using
the drive unit in accordance with all the recommendations of this guide. It is essential to
make sure that no untrained people can open the gate. The user must monitor the gate
opening or closing and keep all people at a safe distance until the operation is complete.
Never allow children to play with the gate control devices.
Keep remote controls out of the reach of children.
Do not deliberately prevent the gate from moving.
In the event of a malfunction, disconnect the power, use the emergency unlocking to
gain access to the property and contact the POLARGOS technical support department.
Do not try to open the gate manually if the drive unit has not been unlocked. No natural
obstacles (a branch, a stone, tall grass, etc.) should obstruct the movement of the gate.
8. Safety instructions regarding maintenance
DANGER
The drive unit must be disconnected from any power supply during cleaning and
maintenance as well as replacement of the parts.
WARNING
Every month, the following must be checked:
- the installation, in order to discover any signs of wear or damage to the conductors
or assembly elements.
- whether the drive unit changes operation direction, when the gate encounters a 50-mm
obstacle that is halfway up the gate leaf.
Do not use the drive unit if it needs repairing or adjusting. Gates in poor condition must
be repaired, reinforced or even replaced a er prior approval of the POLARGOS technical
department.
Use only original parts for any maintenance or repair work. Any technical, electronic,
or mechanical modi cations to the drive unit must be performed with the approval
of the POLARGOS assistance department.
If the installation is equipped with photocells and/or an orange light, clean the
photocells optical components and the orange light regularly.
8 9
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
9. About batteries
DANGER
Do not leave batteries / plastic batteries within reach of children. Keep them out
of reach of children. There is a risk that these components could be swallowed by
children or pets. Risk of death! If such a situation does occur, immediately seek
medical advice or go to hospital.
Take care that the batteries are not short-circuited, thrown in the re or recharged.
There is a risk of explosion.
10. Recycling and disposal of used equipment
If installed, the battery must be removed from the drive unit before its disposal.
Do not dispose of used remote control batteries or the battery with household
waste, unless it is installed. They must be taken to a special recycling collection
point in order to recycle them.
Do not dispose the decommissioned drive unit with household waste. Such a
drive unit should be transferred to its distributor or local authority’s special
waste collection points.
11. Regulations
POLARGOS hereby con rms that this product conforms to the basic
requirements and other relevant provisions of Directive 1999/5/CE. This
Declaration of Conformity can be viewed at www.polargos.pl
This product is approved for use in the European Union and Switzerland.
12. Risk prevention
Identi cation of danger zones
Zone 1
Zone 2 Zone 3
Zone 4
Zone 4
Zone 5
Zone 6
Solution:
Recommended
installation
of Photocells.
Solution:
Detection and removal
of the xed element
Minimum safety
distance between
the gate and the xed
parts is 50 cm.
Solution:
Detection and removal
of the obstacle.
ZONE 1
Risk of impact and crushing
ZONE 3
Risk of crushing during opening by
a nearby xed element
ZONE 2
Risk of trapping and cutting on the
surface of the gate blade
Protective measures to be taken to prevent risks
Photocells
10 11
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Solution:
Check whether the sill and guide rail
are visible, whether they are at
a height greater than 5 mm,
whether or not they are highlighted,
and whether or not they are without
sharp edges.
If this is not the case, mark the
sections that are placed excessively
high and are invisible.
ZONE 5
Risk of dragging and then crushing at the gear
wheel/toothed bar connection
Solution:
Removal of the obstacles.
ZONE 6
Risk of tripping over the guide rail on the ground.
(For gates with the guide rail on the ground)
ZONE 4
Risk of trapping and crushing
between the rails and rollers
Solution:
Removal of the obstacles.
h > 5 mm
12 13
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Product description
Contents of the SIMPLE MOVE set
d
a
b
c
www.polargos.pl
SIMPLE MOVE 102
PL 'LQRPSIAH?ÑKMLR?ȴSÑGÑM@QȇSEG
f
g
j
i
k
l
m
e
Mark Name Qty
aDrive x 1
bToothed bar base rack
33 cm x 20 mm
x 13
cAssembly template x 1
dRemote control
with 2 buttons
x 2
eInstallation and operation
guide
x 1
Mark Name Qty
nNuts M10, galvanized x 8
oFlat washers 10.5x22x2,
galvanized
x 8
pDouble-thread screw
10x15 mm
x 4
rPin 10x60 S12 x 4
Mark Name Qty
fEarth cable x 1
gSelf-tapping screw x 4
hCable clamp x 1
iShield screw x 1
jRound gasket x 1
kInsulated round terminal x 1
lSmall at washer x 2
mStar washer x 2
84
72
232
48
109
218 214
109 180 25
Scope of application
General view of the installation
Mark Name
AZone lighting*
BOrange light*
CAntenna*
DSafety edge*
EPhotocells*
Mark Name
FClosing stop
GOpening stop*
HDrive
IToothed bar
This product is designed as the drive unit of a cantilever gate:
with a max. length of 6 m and a max. weight
of 400 kg
made of PVC, wood, or metal
in residential properties..
Dimensions
*optional accessories
SIMPLE MOVE 102 for POLARGOS
You will also need:
A
BC
F
I
D
E
H
G
h
14 15
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Preliminary requirements for assembly
Stops on the ground
Gate inspection
Presentation of the electronic control system
Positioning the drive
Preliminary electrical system
The gate movement track must be limited by stops rmly xed to the ground. The
stops limit its extreme position during opening while the post performs this function during closing.
The gate must be in good technical condition, free from mechanical damage.
The gate must be in a horizontal position during the whole movement cycle and it must open and close
without the necessity of using excessive power. Check whether the gate is perpendicular to the ground and
whether there are no obstructions that could prevent proper gate movement.
Closing stop
Opening stop
Gate
Concrete
foundations
Laying of cables
Required cables
Mains supply: 3 x 1.5 mm 2 or 3 x 2.5 mm2 conductor
for outdoor use (type H07RN-F minimum)
Photocell connection: 2 x 0.75 mm2 conductor
Other accessories: see page 16
The supply cable must be laid in
accordance with the electrical standards
in force in the country of use.
If the cables cannot be laid underground,
use a cable grommet which will withstand
the weight of vehicles.
Laying cables
The cables laid underground must be equipped with a protective
sheath with a su cient diameter to contain all the cables.
Connect the power supply of 230 V as close to the location of the
drive unit assembly as possible.
30s
RADIO
RADIO
P1
P1
RESET
RESET
G F E D C B A
Mark Name Function
AButton Self-teaching launch Electronic control system launch
BIndicator light
RADIO
Lights up each time the electronic control system receives
a command via radio
CIndicator
light
Lights up during activation/deactivation of the opening
for pedestrian entry
DIndicator
light
On automatic closing of the gate is activated
O automatic closing of the gate is not activated
Flashing the “automatic closing” setting is selected
EIndicator
light P1
O the gate operates at standard speed
Slowly
ashing
the gate operates at low speed
Flashing the gate “speed” setting is selected
FIndicator light
RESET
On only settings or the settings and the radio control
points are deleted
Flashing the settings and radio control points deletion
function is selected
GIndicator
light
On the drive unit is functioning correctly – the electronic
control system is reactivated
O the drive unit is functioning correctly – the electronic
control system is on standby
Flashing see diagnostics page 32
16 17
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Concrete foundations
Vertical setting
Required cables
Gate
Foundation Foundation
Laying of cables
Toothed bar
The concrete foundations on which the drive will be installed must comply with the dimensions
indicated in the diagrams below.
The wiring details are provided in the “ACCESSORIES WIRING” section on pages from 21 to 32.
To connect several accessories to the START terminal, a cable with a 0.3 mm² cross section may be
used (example: telephone cable) instead of a cable with a cross section of 0.75 mm².
ANT
ANT
BUSBUS
11 33
22 44 55 66
START
ST
ART
M1M1
M2
M2
1111 13131010 1212
BATT
BATT
++
--
LIGHT
LIGHT
230V230V
1515 1717
1414 1616
77
-
FLASH
88 99
24V
+
LL NN
TX RX
2 x 0.75 mm²
2 x 0.75 mm²
2 x 0.75 mm²
2 x 0.75 mm²
2 x 0.75 mm²
Coaxial cable
maks. 500 W
230V power supply 3 x 1,5 mm² or 3 x 2,5 mm²
for outdoor use
(type H07RN-F mini)
The drive unit should be located slightly above the ground (more than 20 mm).
Choose a suitable position for the toothed bar. If necessary, create a concrete overlay. It is necessary to take
into account the position of the gate carriages.
75 do 80
Nadlewka
32
12
> 97
> 20 77
<100
Overlay
Gate
18 19
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
1 ASSEMBLY
1.1 Screw assembly
1.2 Fixing the Drive
Tools required for assembly (not provided)
17
12
3,5
PZ2
T25
10
The sequence of stages
Screw assembly
Fixing the Drive
Toothed bar assembly
Mechanical adjustment
1. Place the assembly template on the ground
(the template is printed on cardboard) and drill
holes using a drill (Ø 12 mm) suitable for the
ground type. r
2. Insert the pins (12x60 S12). Tighten
the double-thread screws (M10x15). p
1. Screw in 4 nuts (M10, galvanized n)
and put 4 washers ( at, Ø10 5x22x2,
galvanized). o
2. Remove the cover from the drive. a
3. Place the drive onto
the screws: the ange
(drive basis) must be at
a maximum height of 25
mm above the ground. The
recommended distance is
between 20 and 25 mm.
4. A er the drive is set at the correct height from
the ground, attach it using washers ( at, Ø10
5x22x2, galvanized) o and 4 nuts
(M10, galvanized). n
5. Insert the cable grommet h that has been drilled
through in the hole provided for the supply cable.
Apply a small amount of grease to the
screws before screwing them into the pins.
Use a spirit level to check if the drive is
positioned correctly.
20 21
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
1.3 Toothed bar assembly
1. Check whether the drive is really
unlocked when the lever
is in the position.
2. Insert the pins (12x60 S12). Tighten
the double-thread screws (M10x15).
3. Assembly of the bars should start from
the lock side.
4. Insert bar No. 1 at a suitable distance from
the lock side.
5. Fix the toothed bar to bar No. 1 b and fasten
using screws M6x50. Fasten the rst bar
in such a way as to feel slight resistance.
6. Level the bar. The bars No. 1 – No. 4 have
bean-shaped elements for horizontal
adjustment; the toothed bars can be adjusted
vertically.
7. Fasten the rest of the toothed bars
to the bar No. 1.
The last toothed bar on the bar No. 1
will connect the bars No. 2 and No. 1.
8. Fasten the subsequent bars and toothed bars
as shown above.
9. Once the bars are fastened, check whether
everything is level or not; if not, correct this.
77
11
-
0
4
No.1
No.2
No.3
No.4
1
Bar No. 4
Bar No. 3
Bar No. 2
Bean-shaped
element for
horizontal
adjustment
Bean-shaped
element for
vertical
adjustment
Bar No. 1
Toothed
bar
Screw M6x50
Washer M6
Start of assembly
lis
22 23
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
1.5 Drive wiring
For safety reasons, these activities must be carried out only with the power supply disconnected.
By default, the drive is wired for installation on the le -hand side of the gate (looking from inside).
In order to install the drive on right hand side of the gate, interchange the cables connected to terminals
9 and 10 of the electronic control system (green label M1).
55 66
START
START
M1
M1
M2
M2
1111 13131010 1212
BATT
BATT
++
--
77
-
FLASH
88 99
24V
+
Brown
Blue
55 66
START
START
M1
M1
M2
M2
1111 13131010 1212
BATT
BATT
++
--
77
-
FLASH
88 99
24V
+
Brown
Blue
Drive on le hand side
View from inside
Drive on right hand side
View from inside
Do not connect any cable to terminal M2.
1.4 Mechanical adjustment
Never lock the drive when the gate is in motion.
2 mm
Adjust the height of the drive and/or the toothed
bar in order to obtain a clearance of approx. 2 mm
between the bar and the gear wheel. This setting
is important because it helps to avoid premature
wear of the gear wheel and the toothed bar; the
gear wheel should not bear the weight of the gate.
Check whether:
the drive unit is located at the correct height;
the gate moves properly: the gate should
move without di culty along its track;
the gear wheel is driven all the time
when the gate moves along its track;
the set consisting of the
toothed bar and the gear
wheel does not change its
position substantially along
the entire length of the gate
track.
If these conditions are not met:
1. Adjust the height and set the
drive at a suitable level using
the 4 nuts n located under the drive.
2. If necessary, adjust the position of the toothed
bar and tighten up the drive nuts.
3. Close the gate.
4. Lock the drive.
24 25
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
1.6 Connecting to the 230 V power supply
For safety reasons, these activities must be carried
out only with the power supply disconnected.
Use 3 x 1.5 mm2 or 3 x 2.5 mm2 cable for outdoor
use (type H07RN-F mini).
The cable clamp supplied must be used. For
all low-voltage cables, check whether they can
withstand a force of 100 N or are in accordance
with the provisions in force in the country of use.
Check whether the cables have not moved when
this force has been applied.
Neutral
150 mm
8 mm
100 mm
Phase
1. Strip the cable at a distance of
150 mm.
2. Cut the live and neutral cable to a
length of 100 mm.
3. Strip the covering to 3 cables to a
length of 8 mm.
4. Crimp the provided terminal
on the earth cable (yellow and
green).
5. Connect the cables as shown
in the table:
Conductor
colour
Type Terminal Comments
Blue Neutral 17
Brown/
Black/Red
Live 16
Yellow and
green
Earth Tighten a at washer
l, the power supply
earth terminal
crimped in step 4 and
a star washer m
using a screw g.
7. Tighten the supplied cable clamp.
For a 3x1.5 mm² cable For a 3x2.5 mm² cable
ANT
ANT
BUS
BUS
11 3322 44 55 66
START
ST
ART
M1M1
M2
M2
1111 13
1310
101212
BATT
BATT
++
--
LIGHT
LIGHT
230V230V
15
1517
17
1414 16
16
77
-
FLASH
88 99
24V
+
LL NN
16
17
230V
Neutral
Phase
Position the antenna onto the drive shield.
If the supplied antenna is not factory-installed
If the supplied conductor is not pre-installed
1.8 Position of the electronic control system antenna
1.7 Earthing of the electronic control system
1. Connect the supplied earth cable f to the
top right of the electronic control system.
2. Fit a at washer l, the earth cable
terminal f and a star washer m using a
screw g to the top of the drive.
26 27
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
2 STARTUP AND STANDARD USE
2.1 Switching the installation on 2.3 Standby / reactivation of the electronic control system
2. If the indicator light remains unlit or the
number of ashes is di erent than expected:
see diagnostics on page 43.
1. The indicator ashes (twice).
The power supply of the drive is ON
and waiting for self-learning.
2.2 Gate track self-learning
Preliminary requirements – before starting self-learning, check whether:
The installation is switched on:
the indicator light ashes (twice).
The gate is at its mid-point.
The drive is locked.
Press the button on the electronic control
system.
The gate opens, closes, opens partially and
closes again.
The indicator light emits a continuous light.
Self-learning has been successfully
completed and the drive is operational.
If the indicator light ashes (twice), begin
the self-learning process again.
The gate must be closed once self-learning
is complete.
If the gate is open, see the IMPORTANT box
below.
During the self-learning process, pressing button 1 on the remote control or the button on the
electronic control system stops the gate and the self-learning process.
IMPORTANT:
If the gate is open once self-learning is complete:
1. Delete the settings (see page 42).
2. Switch the drive o .
3. Replace the cables connected to terminals 9 and 10 (green label M1) of the electronic control
system (see “Drive wiring”, page 12).
4. Unlock the drive.
5. Position the gate at its mid-point.
6. Lock the drive.
7. Switch the drive on.
8. Start the self-learning process again.
2.4 Plugging the holes
To check whether the drive is switched on or to
check/modify the settings, press the , button
for 2 seconds to reactivate the electronic module.
Once all the cables are laid, plug all the holes
(oblong holes, cable feed holes) using silicone.
Once the self-learning process is complete,
the electronic module automatically switches
to standby a er 5 minutes of inactivity to save
energy.
In standby mode, all the indicator lights are o .
You are strongly advised to plug all the holes to
avoid short circuits caused by insects.
2.5 Shield assembly
2
1
1. Place the shield on the drive ange (base).
2. Mount the gasket j, to ensure the tight
tting of the drive unit and then the shield
screw i.
3. Tighten the shield.
28 29
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
If an obstacle is detected (an abnormal force on the drive unit):
During opening of the gate: the gate stops.
During closing of the gate: the gate stops and reopens.
2.6 Complete opening and closing of the gate
2.7 Obstacle detection
The remote controls supplied in the set are not
programmed.
The remote control must be programmed.
See point 5.2
3 WIRING OF ACCESSORIES
3.1 Photocells
(optional)
For safety reasons, carry out these activities only with the power supply disconnected.
It is not possible to wire a second set of photocells in the case of this drive unit.
TX
12 1235
RX
BUSBUS
33 44
Assembly
A er wiring the photocells:
switch the drive on;
start the gate opening or closing procedure.
The photocells will be recognised by the
electronic control system once this movement
is complete.
Operation with photocells
If the photocells are blocked when closing the
gate, the gate will stop and reopen.
10 W - 24 V bulb MAXIMUM – The use of a bulb with power greater than 10 W- 24 V can cause the drive
unit to malfunction..
3.2 Orange light
(optional)
Operation of the orange light
The orange light ashes while the gate is moving.
You are advised to perform self-learning of the gate track before connecting the accessories
(photocells, orange light, etc.)
30 31
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
This element is not compatible with solar
energy supply systems.
3.3 Battery (optional)
Technical data of the battery:
Operating time: 10 cycles in continuous mode or
24 hours if the gate is in good technical condition
(depending on the battery charge and external
conditions).
Optimum charging time for the battery before
use: 48 hours.
Service life: 3 years.
The backup battery ensures the operation of the
gate in the event of an electrical supply failure.
The indicator light ashes (1 pulse) when
the drive is battery-operated.
To lengthen the length of time of the battery
operation, the wire control systems are
disconnected; the gate is controlled with
remote controls and radio transmitters only.
To ensure optimum battery life, disconnect the
power supply from the gate three times a year and
run several cycles with the battery operated drive.
3.4 Independent antenna (optional)
Connect the antenna to the electronic module
terminals 1 and 2 (blue label „ANT”):
cable core to terminal 1
earthing strap to terminal 2
An independent antenna with a longer range
can replace the wire antenna.
Place it on the post top and check to see if it is
exposed.
3.5 Video door phone (optional)
NC
COM
COM
NO
NO
This element is not compatible with a solar
energy supply system.
This element is not compatible with a solar
energy supply system.
3.6 Key switch (optional)
3.7 Zone lighting (optional)
This element is not compatible with a solar energy supply system.
Use only halogen or incandescent bulbs for the zone lighting, 500 W maximum.
32 33
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
3.8 Solar energy supply (optional)
Never connect the drive unit to a power supply of 230 V when it is already connected to a solar energy
source because this can lead to damage to the electronic module of the drive.
When the drive unit operates using a solar
energy power supply:
the gate can be controlled by means of remote
controls and radio transmitters only (wire
control is inactive),
protecting wired accessories (photocells, the
orange light) are still active.
4 ADVANCED PARAMETER SETTINGS
4.1 Opening for pedestrian entry
Pressing the remote control button programmed to open for pedestrian entry causes opening of the
gate to a width of about 1 metre. Pressing it again causes the gate to close.
Button number 1 on 2- or 4-button remote controls cannot be programmed to control opening for
pedestrian entry.
See "Programming the remote controls”, pages 38-40, for more information.
1 2 3
>2s
Press and hold the
button of the electronic
control system for 2
seconds.
The indicator light
comes on.
Place the remote control on
the electronic control system
target.
Press button 2 on the remote control
(less than 0.5 second)
The RADIO and indicator lights
come on then go out. The opening for
pedestrian entry is activated on this
button.
Activation of opening for pedestrian entry
Operation of opening to enable pedestrian entry
Repeat the “Activation of opening for pedestrian entry” procedure using the button, for which the opening
of pedestrian entry must be deactivated. The indicator light comes on then goes out. Opening for
pedestrian entry is deactivated on this button.
Deactivation of opening for pedestrian entry
Move away from the electronic control system to test the opening for pedestrian entry.
34 35
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
4.2 Automatic closing
4 5 6 7
Keep button 2 of the remote control pressed until
the indicator light goes out and then lights up
and emits a continuous light.
A er releasing
button 2, the indicator
light ashes;
press button 1 on the
remote control 3 times.
The indicator light
remains lit.
Automatic closing
is activated.
The automatic closing can be activated only if the photocells are connected and recognised by the
drive's electronic control system.
1 2 3
>2s
Press and hold the button
of the electronic control
system for 2 seconds.
The indicator light comes
on.
Place the remote control on
the electronic control system
target.
Keep button 1 of the remote
control pressed until the
indicator light starts
ashing.
Activating automatic closing
Automatic closing function
Press button 1 on the remote control to open the gate.
The gate closes again a er 30 seconds or 5 seconds if the photocells detect an obstacle.
Automatic closing can be interrupted by pressing button 1 on the remote control. In order to close the
gate, press button 1 on the remote control again.
123
>2s
Press and hold the button
of the electronic control
system for 2 seconds.
The indicator light comes
on.
Place the remote control on
the electronic control system
target.
Keep button 1 of the remote
control pressed until the
indicator light starts
ashing.
4 5 6
Press button 2 on the remote control.
The indicator light ashes.
Press button 1 on
the remote control
3 times.
The indicator ligh is o .
Automatic closing is deactivated.
Deactivating automatic closing
36 37
EN – Installation and operation guide SIMPLE MOVE 102
EN – Installation and operation guide SIMPLE MOVE 102
EN
EN
Scope of the application
Set the gate speed in accordance with the table below:
Gate weight Standard speed Slow speed
0 do <100 kg
100 do <200 kg
200 do <300 kg + strip sensor*
300 do <400 kg + strip sensor*
*Installation of a passive strip sensor on the gate is mandatory.
A speed not suitable for the weight of the
gate could cause serious injury to the users,
for example by being crushed. To meet the
requirements of the standard EN 12453, it
is essential to comply with the scope of the
application’s limitations.
4.3 Gate speed
By default, the gate operates at standard
speed.
1 2 3 4 5
Press and hold
the button
of the electronic
control system
for 2 seconds.
The indicator
light comes
on.
Place the remote
control on
the electronic
control system
target.
Keep
button 1 of the
remote control
pressed until
the indicator
light starts
ashing.
Press button 1
on the remote
control once.
The indicator
light P1 ashes.
Setting slow speed
Setting slow speed (continued)
6
Keep button 2 of the remote control pressed until the indicator light P1 starts slowly ashing.
Slow speed is selected.
7
Press button 1 on the remote control 2 times. The indicator light P1 ashes slowly.
Slow speed is selected.
Returning to standard speed
123
Press and hold the
button of the
electronic control
system for 2 seconds.
The indicator light
comes on.
Place the remote control on the electronic
control system target.
Keep button 1 of the remote
control pressed until the
indicator light starts
ashing.
45 6
Press button 1 on
the remote control
once.
The indicator
light P1 ashes.
Press button 2 on the remote control
once.
The indicator light P1 goes out for 5
seconds, and then ashes.
Press button 1 on the remote
control 2 times. The indicator
light P1 is o . Standard speed
is selected.
/