LG MA12AH-NF1.ANCALAP Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

This manual is also suitable for

www.lge.com
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : MULTI TYPE WALL MOUNTED
P/NO : MFL37562521
2 Multi Type Air Conditioner
Multi Type Air Conditioner Ownerʼs Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
n Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
Safety Precautions...................................3
Electrical Safety .......................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
Operating Instructions ............................7
How to insert the Batteries ....................7
Wireless Remote Controller
Maintenance..........................................7
Operating Method..................................7
Operation Indication Lamps ..................8
Wireless Remote Controller...................9
Operation Mode...................................10
Healthy Dehumidification Operation....11
Air Circulation Operation .....................11
Auto Operation ....................................11
Jet Cool ...............................................12
Auto Clean Operation..........................12
NEO PLASMA Purification
Operation.............................................12
Energy-Saving Cooling Mode
(Optional).............................................13
Display Luminosity (Optional)..............13
Forced operation .................................13
Setting the Current Time .....................14
Timer Setting .......................................14
To cancel the timer setting ..................14
Sleep Mode .........................................14
Vertical / Horizontal Airflow Direction
Control (Optional) ................................15
Auto Restart Function..........................15
Maintenance and Service ......................16
Artcool Type ........................................16
How to replace picture & photograph
(Art Cool Type2) ..................................17
When the air conditioner is not going
to be used for a long time....................18
Operation Tips.....................................18
Troubleshooting...................................19
Owner's Manual 3
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Always use a power plug and socket with
a ground terminal.
• There is a risk of electric shock.
Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control
box securely.
• There is risk of fire or electric shock due to
dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
Do not install the product on a defective
installation stand. Be sure that the
installation area does not deteriorate with
age.
• It may cause product to fall.
Never install the outdoor unit on a
moving base or a place from where it
can fall down.
• The falling outdoor unit can cause damage or
injury or even death of a person.
When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.
• An charged capacitor can cause electrical
shock.
When installing the unit, use the
installation kit provided with the product.
• Otherwise the unit may fall and cause severe
injury.
Be sure to use only those parts which
are listed in the svc parts list. Never
attempt to modify the equipment.
• The use of inappropriate parts can cause an
electrical shock, excessive heat generation or
fire.
4 Multi Type Air Conditioner
Safety Precautions
Indoor/outdoor wiring connections must
be secured tightly and the cable should
be routed properly so that there is no
force pulling the cable from the
connection terminals.
• Improper or loose connections can cause
heat generation or fire.
Safely dispose off the packing materials.
Like screws, nails, batteries, broken
things etc after installation or svc and
then tear away and thraw away the plastic
packaging bags.
• Children may play with them and cause
injury.
Make sure to check that the power cable
plug is not dirty, loose or broken and
then only insert the plug completely.
• Dirty, loose or broken power plug can
cause electric shock or fire.
Be sure to check the refrigerant to the
used. Please read the label on the product.
• Incorrect refrigerant used can prevent the
normal operation of the unit.
Don't use a power cord, a plug or a loose
socket which is damaged.
• Otherwise it may cause a fire or electrical
shock.
Do not touch , operate, or repair the
product with wet hands. Hold the plug by
hand when taking out
• There is risk of electric shock or fire.
Do not place a heater or other heating
appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric
parts. Install the unit away from water
sources.
• There is risk of fire, failure of the product, or
electric shock.
Do not store or use or even allow
flammable gas or combustibles near the
product.
• There is risk of fire.
Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.
• Oxygen deficiency could occur and hence
harm your health.
Do not open the front grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock,
or product failure.
If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to
time when operating it together with a
stove, or heating element etc.
• Oxygen deficiency can occur and hence harm
your health.
Turn the main power off and unplug the
unit when cleaning or repairing the
product.
• There is risk of electric shock.
When the product is not to be used for a
long time, disconnect the power supply
plug or turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody
especially kids could step on or fall onto
the outdoor unit.
• This could result in personal injury and
product damage.
Take care to ensure that power cable
could not be pulled out or damaged
during operation.
• There is risk of fire or electric shock.
Do not place ANYTHING on the power
cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug to turn the unit
ON/OFF .
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of
explosion or fire.
CAUTION
Two or more people must lift and
transport the product.
• Avoid personal injury.
Do not install the product where it will be
exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Install the drain hose to ensure that the
condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the
product.
• To avoid vibration or noise.
Do not install the product where the noise
or hot air from the outdoor unit could
damage or disturb the neighborhoods.
• It may cause a problem for your neighbors
and hence dispute.
Always check for gas (refrigerant)
leakage after installation or repair of
product.
• Low refrigerant levels may cause failure of
product.
Owner's Manual 5
Safety Precautions
Do not use the product for special purposes,
such as preserving foods, works of art, etc. It
is a consumer air conditioner, not a precision
refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use
harsh detergents, solvents or splashing
water etc .
• There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Do not touch the metal parts of the
product when removing the air filter.
• There is risk of personal injury.
Do not step on or put anyting on the
product. (outdoor units)
• There is risk of personal injury and failure of
product.
Always insert the filter securely after
cleaning. Clean the filter every two weeks
or more often if necessary.
• A dirty filter reduces the efficiency.
Do not insert hands or other objects
through the air inlet or outlet while the
product is operating.
• There are sharp and moving parts that could
cause personal injury.
Be cautious when unpacking and
installing the product.
• Sharp edges could cause injury.
If the refrigerant gas leaks during the
repair, do not touch the leakaing
refrigerant gas.
• The refrigernat gas can cause frostbite (cold
burn)
Do not tilt the unit when removing or
uninstalling it.
• The condensed water inside can spill .
Do not mix air or gas other than the
specified refrigerant used in the system .
• If air enters the refrigerant system, an
excessively high pressure results, causing
equipment damage or injury.
If the refrigerant gas leaks during the
installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
Dismantling the unit, treatment of the
refrigerant oil and eventual parts should
be done in accordance with local and
national standards.
Replace the all batteries in the remote
control with new ones of the same type.
Do not mix old and new batteries or
different types of batteries.
• There is risk of fire or product failure.
Do not recharge or disassemble the
batteries. Do not dispose off batteries in
a fire.
• They may burn or explode.
If the liquid from the batteries gets onto
your skin or clothes, wash it well with
clean water. Do not use the remote if the
batteries have leaked.
• The chemicals in batteries could cause burns
or other health hazards.
If you eat the liquid from the batteries,
brush your teeth and see doctor. Do not
use the remote if the batteries have
leaked.
• The chemicals in batteries could cause
burns or other health hazards.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and wet or damage
furniture.
Do not expose your skin or kids or
plants to the cool or hot air draft.
• This could harm to your health.
Do not drink the water drained from the
product.
• It is not sanitary and could cause serious
health issues.
Use a firm stool or ladder when cleaning,
maintaining or repairing the product at an height.
• Be careful and avoid personal injury.
6 Multi Type Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards. For temporary
situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
WARNING
WARNING
Temporary Use of an Adapter
Temporary Use of an Extension Cord
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
This appliance should be installed in accordance with national wiring regulations. This guide acts as a
guide to help to explain product features.
WARNING
Owner's Manual 7
Operating Instructions
1. Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper
communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote
control, change their position or consult your serviceman.
NOTE
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
Artcool Type
Operating Instructions
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow
direction.
2. Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the
batteries to save their working life.
3. If the display screen of remote controller starts, fading replace
both of the batteries.
NOTE
Operating Method
8 Multi Type Air Conditioner
Operating Instructions
Artcool Type
Display panel LED indicators
Signal receiver
Front Panel
Air Discharge
Air Filter
Plasma Filter
On/Off : Lights up during the system operation, error code and auto restart setting.
Operation Indication Lamps
Owner's Manual 9
Operating Instructions
The controls will look like the following.
Wireless Remote Controller
Cooling Operation
Auto Operation
Healthy Dehumidification Operation
Heating Operation
Air Circulation
Cooling Model( ), Heat Pump Model( )
Operation Mode
Display
screen
Control
panel
JET
COOL
°C/°F[5SEC]
Control
panel
Display
screen
Description
a
F
Plasma button*: Purifies the air by
removing particles that enter the indoor
unit.
l
=
Sleep mode auto button*: Sets the
sleep mode auto operation.
e
y
Temperature adjustment buttons:
Adjusts the room temperature when
cooling and heating.
d
-
On/Off button: Turns the power on/off.
g
7
v
Indoor fan speed button: Adjusts the
fan speed.
f
AC
DB
E
Operation mode selection button*:
Selects the operation mode.
Cooling operation (A) / Auto operation
or auto changeover (C) /
Dehumidifying operation (D) / Heating
operation (B) / Air circulation (E)
JET
COOL
N
Jet cooling/heating button*: Warms
up or cools down the indoor
temperature within a short period of
time.
ij
HI
Air flow direction button: Adjusts the air
flow direction vertically or horizontally.
k
S
Temperature display button:
Displays the room temperature.
mn
z
Timer button: Sets the current time
and the start / end time.
c
b
u
JG
P
Functions button*: Adjusts the time
and sets the special functions.
J: Auto clean / G: Operates energy
saving cooling / P: Adjusts the
brightness of the indoor unit display
p
-
Set/clear button: Sets or cancels
functions.
r
-
Reset button: Initialize the air
conditioner settings.
* Some functions may not be supported, depending on
the model.
10 Multi Type Air Conditioner
To lower the temperature
To raise the temperature
Natural Wind
Step2(Medium)Step1(Low) Step3(High)
Cooling
Auto
Operantion
Healthy
Dehumidification
Heating
(Heat pump model only)
Air Circulation
Operating Instructions
Press the ON/OFF BUTTON to turn the unit on.
The unit will respond with a beep.
Open the door of the remote controller and press the operation mode button. Each
time the button is pressed, the operation mode is shifted in the direction of the
arrow.
For cooling or heating operation set the desired indoor
temperature by pressing the ROOM TEMPERATURE
SETTING BUTTONS.
For cooling the temperature can be set within 18°C~30°C and
for heating the temperature range is 16°C~30°C.
Set the fan speed with the remote controller. You can select the fan speed in four
steps-low, medium, high and CHAOS by pressing the INDOOR FAN SPEED
SELECTOR BUTTON.
Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Natural wind by the CHAOS logic
o
For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode.
In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Operation Mode
d
f
g
Owner's Manual 11
Operating Instructions
Healthy Dehumidification Operation
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically
changed from high to low or vice versa, depending on the ambient temperature.
NOTE
Air Circulation Operation
During Healthy Dehumidification Operation
o If you select the dehumidification mode on the OPERATION MODE
SELECTION BUTTON, the product starts to run the dehumidification function.
It automatically sets the room temperature and airflow volume to the best
condition for dehumidification, based on the sensed current room
temperature.
In this case, however, the setting temperature is not displayed on the remote
controller and you are not able to control the room temperature either.
o During the healthy dehumidification function, the airflow volume is
automatically set according to the optimization algorithm responding to the
current room temperature status, so that the room condition is kept healthy
and comfortable even in the very humid season.
NOTE : You cannot set the actual setting temperature and the indoor fan
speed in this operation mode. But you can use the Chaos swing
in this operation.
If the system is not operating as desired, switch manually to
another mode.
In this operation mode the actual setting temperature and the
fan speed are automatically set by the electronic control logic
based on the current room temperature.
If you feel hot or cold press the temperature setting buttons
respectively for more cooling or heating effect.
Auto Operation
f
f
f
This operation circulates the air without cooling or heating.
It can be activated by pressing the OPERATION MODE
SELECTION BUTTON. Once the air circulation is activated
you can select the air speed by pressing the INDOOR FAN
SPEED SELECTOR BUTTON.
12 Multi Type Air Conditioner
Operating Instructions
Jet Cool Operation
NEO PLASMA Purification Operation
o During auto clean function, only ON/OFF BUTTON, PLASMA BUTTON and AUTO CLEAN BUTTON can
be used.
NOTE
o During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification
operation can be removed.
Press the AUTO CLEAN BUTTON to activate this function.
Now whenever the unit is turned off, the indoor fan is still running for about 30
minutes internally without cooling or dehumidification operation. Also the
louver is closed.
This dries up any remains of moisture & cleans the unit internally.
If you press AUTO CLEAN BUTTON again during operation, this function is
cancelled.
Auto Clean Operation
Jet cool function can be used to cool the room quickly in hot summer.
When this function is turned on, the air conditioner runs in cooling
operation mode with super high fan speed and 18°C setting
temperature for 30 minutes for fast and effective cooling.
Plasma filter is a technology developed by LG to get rid of microscopic
contaminants in the intake air by generating a plasma of high charge electrons.
This plasma kills and destroys the contaminants completely to provide clean
and hygienic air.
You can activate this operation by pressing the JET COOL BUTTON.
To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or
INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again.
• Jet cool function cannot be activated during heating mode.
• Art Cool and Art Cool Wide models close the side discharges during jet cool operation, for strong cooling.
NOTE
Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller.
Repressing it will deactivate the operation.
This feature can be used in any operation mode and any fan speed can be used while
plasma filter is functioning.
NOTE
JET
COOL
a
Owner's Manual 13
The Display Luminosity can be adjusted by using the remote control.
Open the door of the remote controller, and press the LCD LUMINOSITY button.
Display will be dark. Press the button again to set bright display.
Forced operation
Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button
is pressed. If you want to stop operation, re-press the button.
Energy-Saving Cooling Mode (Optional)
Operating Instructions
Energy-saving cooling mode can save energy in cooling and healthy dehumidification operation, because it
can operate efficiently by setting body-adaptation time according to the change of time and temperature and
adjusting automatically desired temperature.
1. Press the ON/OFF BUTTON to start the unit.
2. Select cooling operation or healthy dehumidification
operation.
3. Press the ENERGY-SAVING COOLING MODE BUTTON.
4. To cancel the energy-saving cooling mode, press the ENERGY-SAVING
COOLING MODE BUTTON again and unit will operate in previous
mode(Cooling or healty dehumidification mode).
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C 21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C 22°C 23°C 24°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".
If you want to stop the operation, re-press the button.
Display Luminosity (Optional)
Because Energy-Saving Cooling Mode is optional function, some product will not operate.
CAUTION
Because Display Luminosity is optional function, some product will not operate.
CAUTION
b
P
u
14 Multi Type Air Conditioner
Operating Instructions
NOTE
• The sleep mode will operate indoor fan at slow speed in cooling mode and at medium speed in heating mode
for pleasant sleep.
• Art Cool and Art Cool Wide (non-Deluxe) close the lower discharge partially in sleep mode for pleasant sleep.
In cooling mode or healthy dehumidification mode:
The setting temperature will rise automatically two times by 1°C over next consecutive 30 minutes (2°C in 1
hour) for a comfortable sleep. Now this will be the final setting temperature as long as sleep mode is functioning.
• If you wish to cancel all timer setting, press the CLEAR ALL BUTTON.
• If you wish to cancel each timer setting, press the TIMER BUTTON to turn timer sleep on or off as you want.
And then press the SET/CLEAR BUTTON aiming the remote controller at the signal receptor.
(The timer lamp on the air conditioner and the display will go off.)
To cancel the timer setting
1. Press the Set/Clear button for 3seconds.
2. Press TIME SETTING BUTTONS until the desired time is set.
3. Press the SET / CLEAR BUTTON.
Check the indicator for A.M. and P.M.
NOTE
Setting the Current Time
On Timer Setting
p
p
o q
1. Press the ON button to turn timer on or off.
2.
Press TIME SETTING buttons until the desired time is set.
3. Press the SET / CLEAR button.
1. Press the OFF button to turn timer on or off.
2. Press TIME SETTING buttons until the desired time
is set.
3. Press the SET / CLEAR button.
Off Timer Setting
m
n
o q
o q
o q
p
p
1. Press the TIMER button to turn timer on or off.
2. Press TIME SETTING buttons until the desired time
is set. (7 hours is the maximum setting)
3. Press the SET / CLEAR button.
Sleep Timer Setting
l
p
Owner's Manual 15
Operating Instructions
The up/down airflow (Vertical airflow) can be
adjusted by using the remote controller.
1. Press the ON/OFF BUTTON to start the unit.
2. Press CHAOS SWING BUTTON.
3. The louvers will swing up &
down automatically.
4. To stop the louver at a desired
angle, press again
The left/right(Horizontal airflow) can be adjusted
by using the remote control.
1. Press the ON/OFF BUTTON to start the unit.
2. Press the HORIZONTAL AIRFLOW
DIRECTION BUTTON.
3. The louvers will swing left &
right automatically.
4. To stop the louvers at a desired
angle, press again.
Vertical / Horizontal Airflow Direction Control (Optional)
• By pressing the CHAOS SWING BUTTON the horizontal air flow direction is changed automatically based on the chaos
algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if
enjoying natural breeze.
• Manually moving the vertical air flow direction louver by hand could damage the mechanism.When the unit is shut off, the
up/down airflow direction louver will close the air outlet vent of the system.
• The Chaos Swing may not run correctly during sleep mode.
NOTE
This feature is enabled by factory default setting, but you can disable it by pressing the
ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp(2) will blink 4
times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator
lamp(1) will blink 4 times.
NOTE
This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
Auto Restart Function
Because Horizontal Airflow Direction Control is optional function, some product will not operate.
CAUTION
i
j
i
j
16 Multi Type Air Conditioner
Maintenance and Service
Maintenance and Service
Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and
unplug the power cord.
CAUTION
Artcool Type
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.
Never use any of these
• Water hotter than 40°C. It may cause deformation and discoloration.
• Volatile substances. They may damage the surface of the air conditioner.
Air Filters
The air filters behind the front panel / grill should be checked and cleaned once in
every 2 weeks or more often if necessary. To remove the filters see the self
explanatory diagrams for each model type. Clean the filters with a vacuum cleaner or
warm soapy water. If dirt is not easily removed, wash with a solution of detergent in
luke warm water. Dry well in shade after washing and reinstall the filters back in place.
Plasma Filters
The plasma filters behind the air filter should be checked and cleaned once in
every 3 months or more often if necessary. To remove the filters see the self
explanatory diagrams for each model type. Clean the filters with a vacuum cleaner.
If it is dirty wash it with water and dry well in shade an install back in place.
Deodorizer Filters
Remove the deodorizer filters behind the air filter and expose them in direct
sunlight for 2 hours. And then insert these filters into original position.
Removal of Filters
CAUTION
G
a
s
o
l
i
n
e
P
o
w
d
e
r
1. Art Cool Type :
Pull out the upper section of front panel and lift it up. Take out a filter with front panel held.
With PUSH button pressed, pull out grip to take out a plasma filter. Dry it completely in the shade after cleaning.
Then set a plasma filter and a filter orderly. Put the hook of front panel onto the hanger, in order to close the front panel.
Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
CAUTION
Front panel
Plasma filter
Front panel hook
Hook-hanger
Air filter
Air filter
Owner's Manual 17
Maintenance and Service
How to replace picture & photograph (Art Cool Type2)
1. Turn off power and then open
the upper part of front panel.
2. Pull out the both links of lower
part of front panel, as
described in the below picture.
3. Push and close the top part of
the front panel and then pull
the bottom part of the panel
forward until it is secured.
4. Take out picture. 5. Turn upside-down of the
picture and turn over mat, then
take off a protective tape
attached at the mat.
6. Place the picture/photograph
between the exited picture and
mat. (Recommended size of a
photo/picture: 450mm x
450mm)
7. Cover mat and press down
with hand(s) until contacting
closely.
8. Slide the photo graph/drawing
requested under both hanger
parts as following, and fix them.
Press the front panel lightly to
close.
9. Push both links of lower part of
panel inside and fix it. Then
turn on.
In case a mat is not used, recommended size of a photo/picture:
522mm x 522mm
When powering on after replacing filter and picture,
the front panel doesn't intervene.
Mat
450mm
450mm
522mm
522mm
Mat
Protective tape
18 Multi Type Air Conditioner
Maintenance and Service
1
1
2
2
3
When the air conditioner is not going to be used for a long time.
Operation Tips
Operate the air conditioner on Air
circulation mode (Refer to page 11) for 2
to 3 hours.
• This will dry out the internal mechanisms.
When air conditioner is not going to be
used for a long time.
When the air conditioner is to be used again.
Turn off the circuit breaker, and
disconnect the power cable.
Remove the batteries from the Remote
Controller.
CAUTION:
Turn off the circuit
breaker when the air conditioner is not
going to be used for a long time.
Dirt may collect and may cause a fire.
Clean the air filter and install it in the
indoor unit.
(Refer to page 14~15 for cleaning filters.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Do not overcool the room.
This is not good for the health
and wastes electricity.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and
windows if possible to keep the
cool air in the room.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Clean the air filter regularly.
Blockages in the air filter reduce
the airflow and lower cooling
and dehumidifying effects.
Clean at least once every two
weeks.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature in
the room.
Ventilate the room
occasionally.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
Owner's Manual 19
Maintenance and Service
Troubleshooting
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.
Case Explanation See page
The air conditioner does not
operate.
The room has a peculiar
odor.
It seems that condensation
is leaking from the air
conditioner.
Air conditioner does not
operate for about 3 minutes
after turning on.
Does not cool or heat
effectively.
The air conditioner
operation is noisy.
Remote Controller display is
faint, or no display at all.
Crack sound is heard.
• Check room temperature setting?
• Check if circuit breaker is on?
• Check that this is not a damp smell exuded by
the walls, carpet, furniture, or cloth items in the
room.
• Check the drain hose is connected tight or if
indoor unit is installed even.
• This is the protector of the mechanism.
• Wait about 3 minutes and operation will begin.
• About 3 minutes delay is applied to protect
compressor from frequenty on/off.
• Is the air filter dirty? See air filter cleaning
instructions.
• Has the temperature been set correctly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
• For a noise that sounds like water flowing.
-This is the sound of refrigerant flowing inside
the air conditioner unit.
• For a noise that sounds like the compressed
air releasing into atmosphere.
-This is the sound of the dehumidifying water
being processed inside the air conditioning
unit.
• Are the batteries depleted?
• Are the batteries inserted in the opposite (+)
and (-) directions?
• This sound is generated by the
expansion/constriction of the front panel, etc.
due to changes of temperature.
10
-
-
-
-
14~15
10
-
-
7
-
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

LG MA12AH-NF1.ANCALAP Owner's manual

Category
Split-system air conditioners
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI