POWER FACTOR CORRECTION (PFC) KIT
Item No. 36220 for Installation in
Heliarc 252 & Heliarc 352 Power Sources
This kit consists of three prewired power factor capacitors (60 uf,440 vac - I/N 950519) assembled in a mounting bracket
(36198GY).
To install PFC Kit, proceed as follows:
F15-284-B July, 2003
Figure 1
PFC Kit Installed In Power Source, Left-Side Rear View
Before installing this kit, make sure all primary input power to the
power source is disconnected and/or lock out procedures are in place.
1. Remove top panel and left side panel from the power source.
2. Assemble the PFC kit to the cross member of the A-frame (left
side) below the input terminal board as shown in Figure 1 using
the 1/4"-20 x 1/2" mounting screw supplied on the cross member.
3.
Connect the two leads with ring terminals from the PFC kit to the
input terminal board (TB1) as follows:
230/460V Units - Connect to terminals 2 and 5.
(H252 - P/N 36200, H352 - P/N 36210)
230/460/575V Units - Connect to terminals 2 and 4.
(H252 - P/N 36201, H352 - P/N 36210)
400V Units - Connect to terminals 2 and 5.
(H252 - P/N 36205, H352 - P/N 36210)
Make sure the connections are firmly tightened.
4. Reassemble the left side panel and top cover.
Input
Terminal
Board
1/4"-20 x 1/2" Screw
(Supplied with Power Source)
PFC KIT