Taylor Technologies K-1640 Owner's manual

Type
Owner's manual
COMPONENTS:
1 x 5202 Instruction
1 x 9198B Sample Tube, Graduated (25 mL) w/ cap & blue dot, plastic
1 x R-0619B-C Hardness Buffer, 2 oz w/ blue cap, DB
1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0683-C Hardness Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Total Hardness Test
1.Rinseandll25mLsampletube(#9198B)to25mLmarkwithwatertobetested
(Fig.1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add5dropsR-0619BHardnessBuer.Swirltomix.
3.Add1dipperR-0620BHardnessIndicatorPowder.Swirluntildissolved.Sample
willturnred(Fig.2)ifhardnessispresent.
4.AddR-0683HardnessReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromredtoblue(Fig.3).
DROP TEST
TOTAL HARDNESS (1 drop = 10 ppm)
5.MultiplydropsofR-0683HardnessReagentby10.Recordaspartspermillion
(ppm)totalhardnessascalciumcarbonate.
NOTE: For14.6mLsample,recorddropsasgrainspergallon(gpg)totalhardness
ascalciumcarbonate.
Fig. 1
Fig. 2
Fig. 3
Instr. #5202
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 7/16
COMPONENTS:
1 x 5203 Instruction
1 x 9198W Sample Tube, Graduated (25 mL) w/ cap & white dot, plastic
1 x R-0638W-C Phenolphthalein Indicator, 2 oz w/ white cap, DB
1 x R-0699-C Iodide Iodate Reagent, 2 oz, DB
1 x R-0725-I Acid Starch Indicator Powder, 10 g
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Sodium Sulfite Test
NOTE: Sample must be cooled to less than 100ºF (38ºC) to prevent high test
results. Sample must be protected from air contact while cooling to prevent
low test results.
1.Collectwatertobetestedinaclean,preferablylarge-mouthed,bottletooverowing.
Immediately cap and cool to room temperature.
2.Rinseandll25mLsampletube(#9198W)to25mLmarkwithcooled(room
temperature) water to be tested (Fig. 1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
DROP TEST
SODIUM SULFITE (1 drop = 10 ppm)
3.Add1dropR-0638WPhenolphthaleinIndicator.Swirltomix.Samplewillturn
pink(Fig.2).
4.AddR-0725AcidStarchIndicatorPowderadipperatatime,swirlingaftereach
dipper, untilcolorchanges frompink tocolorless.Add 2moredippers.Swirl
until dissolved.
5.AddR-0699IodideIodateReagentdropwise,swirlingandcountingaftereach
drop, until sample changes from colorless to a faint but permanent blue (Fig. 3).
6.Multiply drops of R-0699 Iodide Iodate Reagent by 10. Record as parts per
million(ppm)sodiumsulte.
NOTE: For14.6mLsample,recorddropsasgrainspergallon(gpg)sodiumsulte.
NOTE:Forresultsassulte,multiplysodiumsulteconcentrationby0.64.
Fig. 1
Fig. 2
Fig. 3
Instr. #5203
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 9/16
COMPONENTS:
1 x 5212C Instruction
1 x 9198O Sample Tube, Graduated (25 mL) w/ cap & orange dot, plastic
1 x R-0630-C Chromate Indicator, 2 oz, DB
1 x R-0638O-A Phenolphthalein Indicator, .75 oz w/ orange cap, DB
1 x R-0706-C Silver Nitrate Reagent, 2 oz, DB
1 x R-0736O-C Sulfuric Acid .6N, 2 oz w/ orange cap, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Chloride Test
NOTE: Whensultecontentofsamplewatertobetestedexceeds10ppm,the
sulteshouldbeoxidizedtopreventinterferenceintest.A25mLsample
isrstadjustedtotheappropriatepH,then1mL(or25drops)ofR-0649
Hydrogen Peroxide Solution (sold separately) is added and thoroughly
mixed.Continuewiththerestoftheprocedure.
1.Rinseandll25mLsampletube(#9198O)to25mLmarkwithwatertobetested.
2.Add2dropsR-0638OPhenolphthaleinIndicator.Ifsampleturnspink(Fig.1),add
R-0736OSulfuricAcid.6Ndropwise,swirlingaftereachdrop,untilcolorchanges
frompinktocolorless.Ifsampleiscolorless,proceedtoStep3.
DROP TEST
CHLORIDE (1 drop = 10 ppm)
3.Add5dropsR-0630ChromateIndicator.Swirltomix.Samplewillturnyellow
(Fig.2).
4.AddR-0706SilverNitrateReagentdropwise,swirlingandcountingaftereach
drop,untilcolorchangesfromyellowtoamilkysalmon(brick)red(Fig.3).
NOTE: DonotaddenoughR-0706SilverNitrateReagenttogiveabrowncolor.
Firstchangefromyellowtoamilkysalmon(brick)redistheendpoint.
5.MultiplydropsofR-0706SilverNitrateReagentby10.Recordaspartsper
million(ppm)chloride.
Fig. 1
Fig. 2
Fig. 3
Instr. #5212C
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 9/16
COMPONENTS:
1 x 5213 Instruction
1 x 9198G Sample Tube, Graduated (25 mL) w/ cap & green dot, plastic
1 x R-0638G-A Phenolphthalein Indicator, .75 oz w/ green cap, DB
1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB
1 x 0736G-C Sulfuric Acid .6N, 2 oz w/ green cap, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
P/T Alkalinity Test
1.Rinseandll25mLsampletube(#9198G)to25mLmarkwithwatertobetested.
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add3dropsR-0638GPhenolphthaleinIndicator.Swirltomix.Samplewillturnpink
(Fig.1)ifPalkalinityispresent—proceedtoStep3.Ifsampleiscolorless,proceed
toStep4.
DROP TEST
P/T ALKALINITY (1 drop = 50 ppm)
3.AddR-0736GSulfuricAcid.6Ndropwise,swirlingandcountingaftereachdrop,
untilcolorjustchangesfrompinktocolorless.RecorddropsasPreading.
4.Add5dropsR-0645TotalAlkalinityIndicator.Swirltomix.Samplewillturngreen
(Fig.2).
5.AddR-0736GSulfuricAcid.6Ndropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromgreentored(Fig.3).Recordtotaldrops(Steps3&5)as
T reading.
6.Multiply P reading by 50. Record as parts per million (ppm) P alkalinity as
calcium carbonate. Multiply T reading by 50. Record as ppm T alkalinity as
calciumcarbonate.
NOTE: For14.6mLsample,multiplyPreadingby5.Recordasgrainspergallon
(gpg)Palkalinityascalciumcarbonate.MultiplyTreadingby5.Recordas
gpgTalkalinityascalciumcarbonate.
Fig. 1
Fig. 2
Fig. 3
Instr. #5213
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 9/16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Taylor Technologies K-1640 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI