1597BKCCD12

Legrand 1597BKCCD12 User manual

  • Hello! I am an AI chatbot trained to assist you with the Legrand 1597BKCCD12 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
To prevent severe shock or
electrocution, always turn the
power OFF at the service panel
before working with wiring.
Use this GFCI receptacle with
copper or copper-clad wire. Do
not use it with aluminum wire.
Do not install this GFCI receptacle
on a circuit that powers life
support equipment because if
the GFCI trips, it will shut down
the equipment.
For installation in wet locations,
protect the GFCI receptacle with
a weatherproof cover that will
keep both the receptacle and any
plugs dry.
Must be installed in accordance
with national and local electrical
codes.
3. Should you install it?
Installing a GFCI receptacle can be
more complicated than installing a
conventional receptacle.
Make sure that you:
Understand basic wiring principles
and techniques.
Can interpret wiring diagrams.
Have circuit wiring experience.
Are prepared to take a few minutes
to test your work, making sure that
you have wired the GFCI receptacle
correctly.
6. Identify cables/wires
IMPORTANT:
Do not install the GFCI receptacle
in an electrical box containing (a)
more than 4 wires (not including the
grounding wires) or (b) cables with
more than two wires (not including the
grounding wire). Contact a qualified
electrician if either (a) or (b) is true.
If you are replacing an old
receptacle, pull it out of the electrical
box without disconnecting the wires.
If you see one cable (2-3 wires), it
is the LINE cable. The receptacle is
probably in position C (see diagram
to the right). Remove the receptacle
and go to step 7A.
If you see two cables (4-6 wires),
the receptacle is probably in position
A or B (see diagram to the right).
Follow steps a-e of the procedure
to the right.
Procedure: box with two cables
(4-6 wires)
(a)  Detach one cable’s white and hot 
wires from the receptacle and cap
each one separately with a wire
connector. Make sure that they are
from the same cable.
(b) Re-install the receptacle in the
electrical box, attach the faceplate,
then turn the power ON at the
service panel.
(c) Determine if power is flowing to the
receptacle. If so, the capped wires
are the LOAD wires. If not, the
capped wires are the LINE wires.
(d) Turn the power OFF at the service
panel, label the LINE and LOAD
wires, then remove the receptacle.
(e) Go to step 7B.
Placement in circuit:
The GFCI’s place in the circuit 
determines if it protects other
receptacles in the circuit.
Sample circuit:
Placing the GFCI in position A will
also provide protection to “load side”
receptacles B and C. On the other
hand, placing the GFCI in position C
will not provide protection to
receptacles A or B. Remember that
receptacles A, B, and C can be in
different rooms.
1. What is a GFCI?
A GFCI receptacle is different from
conventional receptacles. In the event
of a ground fault, a GFCI will trip and
quickly stop the flow of electricity to
prevent serious injury.
Definition of a ground fault:
Instead of following its normal safe
path, electricity passes through a
person’s body to reach the ground. 
For example, a defective appliance
can cause a ground fault.
A GFCI receptacle does not protect
against circuit overloads, short circuits,
or shocks. For example, you can still
be shocked if you touch bare wires
while standing on a non-conducting
surface such as a wood floor.
Self-Test GFCI Receptacle with
SafeLock Protection
This is a Self-Test GFCI Receptacle
with SafeLock™ Protection; it
conducts an automatic test every three
seconds, ensuring it’s always ready 
to protect. If the device fails the test,
the indicator light flashes to signal
that the GFCI should be replaced.
It also has our proven SafeLock
Protection feature: if critical
components are damaged and
protection is lost, power to this
receptacle, and any downstream
receptacles, will be disconnected.
5. Turn the power OFF
Plug an electrical device, such as
a lamp or radio, into the receptacle
on which you are working. Turn the
lamp or radio on. Then, go to the
service panel. Find the breaker or fuse
that protects that receptacle. Place
the breaker in the OFF position or
completely remove the fuse. The lamp
or radio should turn OFF.
Next, plug in and turn ON the lamp or
radio at the receptacle’s other outlet 
to make sure the power is OFF at
both outlets. If the power is not OFF,
stop work and call an electrician to
complete the installation.
2. The GFCI’s features
ABC
LINE
LOAD
Service
Panel
LOAD
LINE LINE
FRONT VIEW
Screw (terminal) colors:
Green = grounding terminals
Silver = white terminals
Brass = hot terminals
BACK VIEW
Installing and
Testing a
GFCI Receptacle
!
CAUTION
P.O. Box 4822 (800) 223-4185
Syracuse, NY 13221 www.legrand.us
For covering patents, see www.legrand.us/patents
Nº 341082
Please read this leaflet
completely before
getting started.
Receptacle
Outlet
Reset button:
See step 8
Indicator
Light
TEST button:
See step 8
Outlet
Mounting
bracket
LINE
Hot terminal
(Brass):
Connection
for the LINE
cable’s black 
wire
LOAD
Hot terminal
(Brass):
Connection
for the LOAD
cable’s black 
wire
A yellow sticker
covers the LOAD
terminals.
Do not remove the
sticker at this time.
Grounding terminal
(Green): Connection
for bare copper or
green wire
LINE
White terminal
(Silver): Connection
for the LINE cable’s 
white wire
LOAD
White terminal
(Silver): Connection
for the LOAD cable’s 
white wire
4. LINE vs. LOAD
A cable consists of 2 or 3 wires.
LINE cable:
Delivers power from the service
panel (breaker panel or fuse box)
to the GFCI. If there is only one
cable entering the electrical box, it
is the LINE cable. This cable should
be connected to the GFCI’s LINE 
terminals only.
LOAD cable:
Delivers power from the GFCI to
another receptacle in the circuit. This
cable should be connected to the
GFCI’s LOAD terminals only. The 
LOAD terminals are under the yellow
sticker. Do not remove the sticker at
this time.
About wire connections:
Connect the LINE cable wires to the LINE terminals:
The white wire connects to the White terminal (Silver)
The black wire connects to the Hot terminal (Brass)
Connect the LOAD cable wires to the LOAD terminals:
Remove the yellow sticker to reveal the LOAD terminals
The white wire connects to the White terminal (Silver)
The black wire connects to the Hot terminal (Brass)
Connect the grounding wires as shown above (only if there is a grounding wire):
Connect a 6-inch bare copper (or green) 12 or 14 AWG wire to the grounding
terminal on the GFCI. If the box has a grounding terminal, also connect a similar
wire to the grounding terminal on the box. Connect the ends of these wires to
the LINE and LOAD cable’s bare copper (or green) wire using a wire connector. 
If these wires are already in place, check the connections.
Complete the installation:
Fold the wires into the box, keeping the grounding wire away from the White and
Hot terminals. Screw the receptacle to the box and attach the faceplate.
Go to step 8.
A: One cable (2 or 3 wires) entering the box B: Two cables (4 or 6 wires) entering the box
OU
About wire connections:
Connect the LINE cable wires to the LINE terminals:
The white wire connects to the White terminal (Silver)
The black wire connects to the Hot terminal (Brass)
Connect the grounding wire (only if there is a grounding wire):
For a box with no grounding terminal (diagram not shown): Connect the LINE
cable’s bare copper (or green) wire directly to the grounding terminal on the 
GFCI receptacle.
For a box with a grounding terminal (diagram shown above): Connect a 6-inch
bare copper (or green) 12 or 14 AWG wire to the grounding terminal on the
GFCI. Also connect a similar wire to the grounding terminal on the box. Connect
the ends of these wires to the LINE cable’s bare copper (or green) wire using 
a wire connector. If these wires are already in place, check the connections.
Complete the installation:
Fold the wires into the box, keeping the grounding wire away from the White
and Hot terminals. Screw the receptacle to the box and attach the faceplate.
Go to step 8.
8. Test your work
Why perform this test?
If you miswired the GFCI, it may not prevent personal injury or death due to a
ground fault (electrical shock).
Procedure:
(a) Turn the power ON at the service panel. Press the RESET button
fully. The RESET button should stay in. If the RESET button does
not stay in, go to Troubleshooting. If the RESET button stays
in, plug a lamp or radio into the GFCI (and leave it plugged in)
to verify that the power is ON. If there is no power, go to
Troubleshooting.
(b) Press the TEST button in order to trip the device. This should
stop the flow of electricity, making the radio or lamp shut OFF
and the GFCI’s red Indicator Light (if present) come on. Note 
that the RESET button will pop-out. If the power stays ON, or the
red Indicator Light stays off, go to Troubleshooting. If the power
goes OFF, and the red Indicator Light comes on, you have
installed the GFCI receptacle correctly. To restore power, press
the RESET button.
(c) If you installed your GFCI using step 7B, plug a lamp or radio into
surrounding receptacles to see which one(s), in addition to the
GFCI, lost power when you pressed the TEST button. Do not plug
life saving devices into any receptacles that lost power. Place a
“GFCI Protected” sticker on every receptacle that lost power.
(d) Press the TEST button (then RESET button) every month to assure proper operation.
(e) This is a Self-Test GFCI Receptacle with SafeLock Protection™; it conducts
an automatic test every three seconds, ensuring it’s always ready to protect. If 
the device fails the test, the indicator light flashes to signal that the GFCI should
be replaced. It also has our proven SafeLock Protection feature: if critical
components are damaged and protection is lost, power to this receptacle,
and any downstream receptacles, will be disconnected.
7. Connect the wires (choose A or B)… only after reading other side completely
Screw Terminal
Wire
1 inch
Side Wire
Clockwise,
2/3 of the way
around screw
LINE cable brings
power to the GFCI
Grounding connection
to box (if box has a
grounding terminal)
Wire
connector
Electrical
box
LOAD cable
feeds power to
other receptacles
Screw Terminal
Wire
1 inch
Back Wire Holes
Wire
.5 inch
Back Wire Holes
Wire
.5 inch
TROUBLESHOOTING
Turn the power OFF and check the wire connections against the appropriate wiring
diagram in step 7A or 7B. Make sure that there are no loose wires or loose connections.
Also, it is possible that you reversed the LINE and LOAD connections. LINE/LOAD
reversal will be indicated by no power at the GFCI and by the RESET button not staying
in when pressed, or by the red Indicator Light remaining off after you press the GFCI’s
TEST button. Reverse the LINE and LOAD connections if necessary. Start the test from
the beginning of step 8 if you rewired any connections to the GFCI.
Side Wire
Clockwise,
2/3 of the way
around screw
Back Wire
2. Securely
tighten screw
beneath wire
hole to retain
inserted wire.
1. Insert wire
to bottom
of hole.
Back Wire
2. Securely
tighten screw
beneath wire
hole to retain
inserted wire.
1. Insert wire
to bottom
of hole.
LIMITED ONE YEAR WARRANTY
Pass & Seymour will remedy any defect in workmanship or material in Pass & Seymour products which may develop under
proper and normal use within one year from date of purchase by a consumer:
(1) by repair or replacement, or, at Pass & Seymour’s option, (2) by return of an amount equal to consumer’s purchase price. 
Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour does not include or cover cost of labor for removal
or reinstallation of the product. ALL OTHER FURTHER ELEMENTS OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL
DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED HEREBY. (Some states do not allow
disclaimers or exclusion or limitation of incidental or consequential damages, so the above disclaimer and limitation or exclusion
may not apply to you.) ANY IMPLIED WARRANTIES INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE ONE YEAR PERIOD SET FORTH ABOVE. (Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.)
To insure safety, all repairs to Pass & Seymour products must be made by Pass & Seymour, or under its specific direction.
Procedure to obtain performance of any warranty obligation is as follows: (1) Contact Pass & Seymour, Syracuse, New York
13221, for instructions concerning return or repair; (2) return the product to Pass & Seymour, postage paid, with your name and
address and a written description of the installation or use of the Pass & Seymour product, and the observed defects or failure to
operate, or other claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Ratings:
15A 125V 60Hz
20A 125V 60Hz
LINE cable brings
power to the GFCI
Grounding connection
to box (if box has a
grounding terminal)
Wire
connector
Electrical
box
Yellow sticker remains
in place to cover the
LOAD terminals
/