Electrolux RH36WC60GS User manual

Category
Cooker hoods
Type
User manual

This manual is also suitable for

Installation, Use & Care Guide
30 and 36 Free-Standing Range Hood
Guia de Instalación, Uso y Cuidado
30 y 36 Campana extractora
Guide dinstallation, utilisation et
dentretien
36 et 42 Hotte aspirante
316495103 SG06CW63HR + SG06CW03HR
AUG/12
2
*NQPSUBOU4BGFUZ*OTUSVDUJPOT
&MFDUSJDBM*OTUBMMBUJPOSFRVJSFNFOUT
Electrical requirements ........................................... 5
IMPORTANT............................................................. 5
Before installing the hood ...................................... 5
List of Materials..................................................... 6
Parts Included with your hood .............................. 6
Optional Accessories .............................................
6
Tools/Materials required ......................................... 6
*OTUBMMJOHUIFIPPE
Installing preparation............................................... 7
Wall framing for adequate support......................... 7
Removing the packaging ....................................... 7
Examples of possible ducting................................ 8
Ductwork installation guidelines ............................ 8
Ductwork and wiring locations.............................. 8
Mounting the duct cover bracket.......................... 9
Ceiling ducting......................................................... 10
Wall ducting..............................................................10
House wiring location.............................................. 10
Install framing for hood support..............................10
Mounting the hood.................................................. 11
Connecting the ductwork........................................12
Finding Information
Please read and save this guide
Thank you for choosing Electrolux, the new premium brand in home appliances. This Use & Care Guide is
part of our commitment to customer satisfaction and product quality throughout the service life of your new
appliance.
We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you,
please use this page to record important product information.
Keep a record for quick reference
Purchase date
Model number
Serial number (see picture for location)
Questions?
For toll-free telephone support in the U.S. and Canada:

For online support and Internet product information visit http:// XXXFMFDUSPMVYBQQMJBODFTDPN
Table of contents
©2007 Electrolux Home Products, Inc. All rights reserved. Printed in Mexico
NOTE
Registering your product with Electrolux enhances
our ability to serve you. You can register online at
www.electroluxappliances.com by dropping your
Product Registration Card in the mail.
Air deector installation
(Recirculating accessories) .....................................12
Making the electrical connections.......................... 13
Mounting the glass canopy..................................... 13
Mounting the duct cover......................................... 14
Features...................................................................15
Control buttons ..................................................... 16
Special functions...................................................
17
Clock programming ................................................17
Grease lter saturation alarm..................................17
Charcoal lter saturation alarm
(Recirculating accesories)........................................17
Audible signal activation and deactivation........... 17
Charcoal lter inclusion and exclusion
(Recirculating accessories) .....................................17
Heat sensor ............................................................. 17
For Best results........................................................ 18
Care and cleaning .................................................19
Filters ....................................................................... 19
Lights ....................................................................... 19
Optional Charcoal Filters .......................................20
Hood Surface ..........................................................20
Warranty Information .............................................. 21
3
Important Safety Instructions
Important Safety Instructions
Read all instructions before using this
appliance.
Save these instructions for future
references
Approved for residential appliances
For residential use only
Do not attempt to install or operate your appliance
until you have read the safety precautions in this
manual. Safety items throughout this manual are
labeled with a WARNING or CAUTION based on the
risk type.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
This symbol alerts you to
situations that may cause
serious body harm, death
or property damage.
This symbol alerts you to
situations that may cause
bodily injury or property
damage.
4
Automatically Operated Device - To Reduce The
Risk Of Injury Disconnect From Power Supply Before
Servicing.
This unit is equpeed with integral disconnecting switch
located inside the blower housing.
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE.
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that
may ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or
when ambeing food (l.e. Crepes Suzette, Cherries
Jubilee, Peppercorn Beef Flambe’).
Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or lter.
Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS, IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
SMOTHER FLAMES with a close - tting lid, cookie
sheet, or other metal tray, then turn off the gas burner
or the electric element. BE CAREFUL TO PREVENT
BURNS. If the ames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be
burned.
DO NOT USE WATER, including wet dishcloths or
towels - a violent steam explosion will result.
Use an extinguisher ONLY if:
You know you have a class ABC extinguisher,
and you already know how to operate it.
The re is small and contained in the area
where it started.
The re department is being called.
You can ght the re with your back to an exit.
OPERATION
Always leave safety grills and lters in place.Without these
components, operating blowers could catch onto hair,
ngers and loose clothing.
The manufacturer declines all responsibility in the event
of failure to observe the instructions given here for
installation,maintenance and suitable use of the product.
The manufacturer further declines all responsibility for injury
due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
a)
b)
c)
d)
a)
b)
c)
d)
1)
2)
3)
4)
Important safety Instructions
READ AND SAVE THESE INSTRUCTIONS
Important safety Instructions
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS OR VAPORS.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer
Before servicing or cleaning the unit, switch power off
at service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Installation Work and Electrical Wiring Must Be Done By
Qualied Person(s) In Accordance With all Aplicable
Codes & Standards, Including Fire-rated Construction.
Sufcient air is needed for proper combustion and ex
hausting of gases through the ue (Chimney) of fuel
burning equipment to prevent back- drafting. Follow
the heating equipment manufacturers guideline
and safety standards such as those published by
the National Fire Protection Association (NFPA),
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
Ducted systems must always be vented to the
outdoors.
To reduce risk of re and to properly exhaust air, be sure to
duct air outside - do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.
Install this hood in accordance with all requirements
specied.
To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.
A.
B.
C.
D.
E.
F.
5
Before installing the hood
For the most effcient air ow exhaust, use a
straight run or as few elbows as possible.
Vent unit to outside of building and recirculating.
At least two people are necessary for installation.
The hood is tted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Qualied Installer, check if they perfectly t with
your cabinet/wall.
Do not use ex ducting.
COLD WEATHER installations should have an
additional backdraft damper that is already
installed to minimize backward cold air ow and a
nonmetallic thermal break to minimize
conduction of outside temperatures as part
of the ductwork. The damper should be
on the cold air side of the thermal break.
The break should be as close as possible
to where the ducting enters the heated portion
of the house.
Make up air: Local building codes may require the
use of Make-Up Air Systems when using Ducted
Ventilation Systems greater than specied CFM of
air movement.
The specied CFM varies from locale to locale.
Consult your HVAC professional for specic
requirements in your area.
1.
2.
3.
4.
5.
6.
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a quali!ed electrical installer.
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code, Part 1 and
C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it
is recommended that a quali!ed electrician determine
that the ground path is adequate.
Do not ground to a gas pipe.
Check with a quali!ed electrician if you are not sure
range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector’s
use.
The range hood must be connected with copper wire
only.
The range hood should be connected directly to the
fused disconnect (Or circuit breaker) box through
metal electrical conduit.
Wire sizes must conform to the requirements of the
National Electrical Code ANSI/NFPA 70 — latest
edition*,or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No. 0-M91 - latest
edition**and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park
Quincy,Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland,
Ohio 44131-5575
Important safety Instructions - Electrical & Installation
requirements
READ AND SAVE THESE INSTRUCTIONS
Electrical & Installation requirements
6
List of Materials
List of Materials
Parts included in your hood
Hood structure assembly with blower, transition.
Lamps already installed.
Duct cover
Bottom.
Top.
Hardware bag with:
Plastic Gasket
Template
Top duct cover wall support bracket (1 piece)
Use, care and installation guide
Wood screws (6 pieces - 3/16” x 13/4)
Hood attachment anchors screws (6 pieces
3/8 x 13/8”)
Assembly screws (8 pieces)
Optional accessories
Recirculation KIT
Tools/Materials required
Duct tape
Wire nuts
Tape to mount template
8rounded metal duct (length to suit installation)
Gloves to protect against sharp edges
Safety glasses
Hammer
Electric drill with 5/16” bit
Pliers
Measuring tape
Saw, jig saw
Level
Knife
Wire cutter
Phillips (Pozidrive) # 2 screwdriver
Torx # 2 screwdriver
1/2” electrical connector (junction box)
Lamp
Vertical
supports
Duct cover
support
Upper
Duct cover
supports
Duct
Covers
Grease
Filter
7
For the most ecient air ow exhaust, use a
straight run or as few elbows as possible.
Vent unit to outside of building and recirculating.
On avarage 2 to 3 hours are necessary to com-
plete installation (without considering cut to be
done on wall and or on cabinet, installation of
ducts , conduit and electrical connections to the
mains).
The hood is tted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Qualied Installer, check if they perfectly t with
your cabinet/wall.
Do not use ex ducting.
COLD WEATHER installations should have an
additional backdraft damper that is already in
stalled backward cold air ow and a nonmetallic
thermal to minimize break to minimize conduction
of outside temperatures as part of the ductwork.
The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to
where the ducting enters the heated portion of
the house.
Make up air: Local building codes may require
the use of Make-Up Air Systems when using
Ducted Ventilation Systems greater than specied
CFM of air movement.
The specied CFM varies from locale to locale.
Consult your HVAC professional for specic
requirements in your area.
5ZQJDBMJOTUBMMBUJPO 
Min installation height from the range top to the
bottom of the hood is 30” if a gas range is used
or 24” to 30” if an electric range is used.
5IFTFIPPETBSFOPUSFDPNNFOEFEUPCFVTFE
PWFSJOEPPSHSJMMT
Installing the hood
Installing the hood
5he hood may be installed vented to the outdoors, or
it can be installed for recirculating operation
(recirculating accessories not supplied with the
hood).
This hood can be installed over any electric and
gas cooktop/range.
*UDBOOPUCFJOTUBMMFEPWFSBOZQSPGFTTJPOBM
DPPLUPQSBOHF
*OTUBMMJOHQSFQBSBUJPO
Advance planning
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the
outdoors.
Use the shortest and straightest duct route
possible.
Refer to “ Ductwork installation guidelines”
paragraph for further informations.
Install a wall cap with damper or roof cap at the
exterior opening. Order the wall or roof cap and
anytransition needed in advance.
Use 8” round metal ductwork only.
Wall framing for adequate support
This vent hood is heavy.
Adequate structure and support must be
provided in all types of installations. The hood
must be secure to vertical studs in the wall, or to
a horizontal support.
The vent hood should be on site before $nal
framing and wall $nishing. This will help to
accurately locate the duct work and electrical
service.
Installation will be easier if the vent hood is
installed before the cook-top and countertop are
installed.
3FNPWJOHUIFQBDLBHJOH
Remove carton carefully, Wear gloves to protect
against sharp edges.
Remove the protective lm covering the product
before putting into operation.
8
Installing the hood
Examples of possible ducting
Ductwork installation guidelines
For safety reasons, ducting should vent directly
outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct ttings (elbows and transitions) reduce air ow
efciency.
Back to back elbows and “S“ turns give very poor
delivery and are not recommended.
A short straight length of duct at the inlet of the
remote blower gives the best delivery.
Transition to duct from the integral blower or remote
duct transition as close to the downdraft as is pos-
sible.
In order of preference, use
1st. 10” round duct
2nd. 8” round duct
3rd. 3-1/4” x 14” duct
4th. 7” round duct
5th. 3-1/4” x l0” duct
6th. 6” round duct
The use of exible metal round duct should only be
used when no other duct tting exists. Limit use to
short lengths and do not crush when making
corners
Ductwork and wiring locations
Determine the exact location of the vent hood.
Locate the template packed with the literature.
The height installation is determined by the
following image. Mark the location.
Installation height: 30” gas cooktop/range or 24”
to 30” electric cooktop/range.
Use a level to draw a horizontal straight pencil line
on the wall, which is your desired
installation height.
Find the centerline of the cooktop. Use a level to
draw a vertical straight pencil line on the wall.
CHECK TO BE SURE THE LINE IS PERFECTLY
PERPERNDICULAR.
Roof pitch w/
ashing and cap
Pipe
Transition
Sidewalk cap w/
gravity damper
Pipe
Transition
Pipe
Transition
Deector
Vertical discharge Recirculating
Sidewalk cap w/
gravity damper
Installation height
9
Installing the hood
Mounting the duct cover bracket
The duct bracket should be installed against the
back wall and ush with the ceiling. This bracket will
hold the telescopic duct cover in place at the top
Secure the bracket to the wall:
Align the marked centerline on the bracket with
the centerline on the wall.
Mark 2 screw hole locations in the wall.
Drill 5/16” pilot holes in the marked locations.
Install wall fastener anchors.
Drive wood screws, by hand, into the fastener to
allow anchors to expand. Remove the screws.
Secure the bracket to the wall with wood screws
and/or fasteners.
Ceiling ducting
If the duct will vent straight up to the ceiling:
Use level to draw a line straight up, from the
centerline on the template to the ceiling.
Measure at least 4 -3/4 ” from the back wall to
the circle center of an 8-½” hole on the ceiling.
Wall ducting
If ductwork will vent to rear:
Use a level to draw a line straight up from the
centerline on the template.
Measure at least 23 - 3/4” (the measure might
vary depending on the elbow used) above the
pencil line that indicates the bottom installation
height, to the circle center of an 8-½” diameter
duct hole (Hole may be elongated for duct elbow).
House wiring location
The junction box is located on the top left side of
the hood.
Wiring should enter the back wall at least 20”
above the bottom of the installation height, and
within 5-7/8” and 4-7/8”of the left side of the
centerline.
4-3/4” circle
center to wall
FOR CEILING DUCT VENTING
Ceiling
FOR
WALL
VENT
DUCT
8-1/2” dia hole
Circle center at
23 3/4” above
the marked bot-
tom pencil line
Horizontal straight
pencil line
10
Installing the hood
Install supporInstall framing for hood support
If drywall is present, mark the screw hole
locations. Remove the template.
Cut away enough drywall to expose 2 vertical
studs at the holes location indicated by the
template.
Install two horizontal supports at least 4 X 2
between two wall studs at the bottom and upper
mounting holes installation location.
room side of the studs.
Use cleats behind both sides of the support to
secure to wall studs.
IMPORTANT- Framing must be capable of
supporting 100 lbs.
8 -1/2min. opening for ductwork
View from rear
cleats
1” x 6min
Mounting
Support
Centerline of
installation
space
Mounting the hood
WARNING: 2 people are required to lift and position
the hood onto the mounting screws.
Install the 8” round transition as shows the image below.
The installation screws and the 8round transition are
included on the hood package.
Place the template on the wall along the horizontal
line, make sure the template is leveled and
centered with the centerline.
Markupper” screw holes locations in the wall.
IMPORTANT. Check to be sure that hole locations
are leveled and correctly centered by the vertical
centerline.
Drive upper” wood screws by hand. Leave ¼ of
distance between the screw head and the wall.
onto the “upperscrews.
8”
11
Installing the hood
Remove the hood.
Drive lower” wood screws, by hand. Remove
screws.
Mount the hood onto theupperscrews.
Drive and tighten the upper wood screws, by
hand.
Drive and tighten the lower wood screws, by
hand.
Marklower” wood screw holes locations in the
wall using a pencil.
12
Air deector installation
(Recirculating accessories)
Assemble the air deector with the duct cover
bracket with 4 assembly screws provided as
shown.
Measure from the bottom of the air deector to
the bottom of the hood outlet, as shown.
Cut the duct at the measured size.
Uninstall the air deector removing the 4
assembly screws.
Slip the duct onto the bottom of the deector.
Place the assembled deector and duct over the
exhaust outlet from the hood.
Assemble the air deector to the duct cover
bracket with 4 assembly screws provided as
shown.
Connecting the ductwork
Install ductwork, making connections in the
direction of airow as illustrated.
Push duct over the exhaust outlet.
Wrap all duct joints and the ange connections
with duct tape for an airtight seal.
Make the same connection in the wall or ceiling
vent exit.
Installing the hood
Duct tape
over seam
Airow
Ductwork
hood
Duct tape
over seam
Airow
13
Installing the hood
Making the electrical connections
Electrical Shock Hazard
Warning: Turn off at the service panel before wiring
this unit.
120 V AC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH À WIRES, ONE OF WHICH
ôGREEN/YELLOWÈ SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW
WIRE MUST BE CONNECTED TO THE
GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove junction box cover and knockout on the
top left side.
If not already done, install 1/2 conduit connector
in junction box.
NOTE: This connector is not included with vent
hood.
Run black (live), white (neutral), and green
(earth) wires (#14 AWG) according to the
National Electrical Code or CSA Standards and
local codes and ordinances in 1/2” conduit from
power supply to junction box.
Connect black, white, and green wires from
power supply to black, white, and green/yellow
wires in junction box respectively.
These connections should be done always
making reference to the electrical diagram found
inside the hood.
Close junction box cover and reapply screws.
Metal electrical
conduit
House
wiring
UL listed
wire nut
Junction box
cover
Knockout
14
Control buttons
Mounting the duct cover
Position the duct cover over the mounted hood.
Slide the bottom of the duct onto the glass area.
Position the top of the duct over the duct
mounting bracket. If a telescopic duct cover is
used, grab the upper part of the telescopic duct
cover, pull it and place it in the duct cover
mounting bracket.
Secure the top of the duct with 2 assembly
screws provided.
Remove Protective
Secure the bottom of the duct with 2 assembly
screws provided.
Install the grease lter and turn power on at service
panel. Check operation of the hood.
15
Features
Blower and light controls
Lamp housings
Grease Filter Handle
Grease Filter
Canopy
Duct cover
Top
Bottom
Louver holes (User for Recirculating accessories)
1.
2.
3.
4.
5.
6.
7.
16
Control buttons
Control buttons
This hood is equipped with an electronic motor and
lamp control.
The control is able to set 4 diferent fan speeds, turn
ON/OFF light and has a timer function.
In the following drawing are described the main key
functions.
1. Light Button
Press lamp button to turn ON the light (Lamp
state previously OFF).
Press lamp button to turn OFF the light (Lamp
state previously ON).
2. Timer Button
The default timer setting is 10 minutes, and it
can be adjusted between 20 minutes and
1 minute.
After pressing the timer button, the control
enters to a timer setup mode, and user can
adjust the timer countdown time with the
” and “ ” buttons within 5 seconds.
The timer can be initiated immediately
pressing the timer button, after setting the
timer duration or pressing the timer button
twice (default 10 minutes setting).
If no action occurs within 5 seconds, the
countdown will start.
During the timer setup the “
” and “
buttons are dedicated to the timer and no
motor action will occur.
Once the timer is initiated, it can be cancelled
by pressing the timer button again.
3. Display
Shows the hood settings.
4. “ ” Button. Speed Decrease/OFF
This button is used to decrease the fan speed,
or turn OFF the fan.
The fan will turn OFF if the “
” button is
If the fan is at second speed and the “
button is pressed, the fan will be set to rst speed.
If the fan is at third speed and the “
” key is
pressed, the fan will be set to second speed.
If the fan is at fourth speed and the “
button is pressed, the fan will be set to third
speed.
If the fan is OFF and the “
” button is
pressed, the control backlight will light up.
5. “ ” Button. Speed Increase/ON
This button is used to increase the fan speed,
or turn ON the fan.
The fan will turn ON if the “
” button is
pressed and the hood was OFF.
If the fan is at rst speed and the “
” button
is pressed, the fan will be set to second
speed.
If the fan is at second speed and the “
button is pressed, the fan will be set to third
speed.
If the fan is at third speed and the “
button is pressed, the fan will be set to fourth
speed.
If the fan is at fourth speed and the “
button is pressed, a beep will sound.
17
Control buttons - Special functions
Special functions
Clock programming
The clock can be reprogrammed at any time except during an active timed function.
The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the “Timer” button for 5 seconds, and after, the clock can be
adjusted with the “
” and “ ” buttons. Colon “:” will ash indicating clock programming mode.
The user can have minute increments / decrements of 1 minute, but if the user keep pressing the “
”/
” buttons for more than 1 second, the increments / decrements will be of 5 minutes.
During this option the control will round to the nearest 5 minutes.
The user can nish on reprogramming the clock pressing the “Timer” button.
After 1 minute of no button pressed the control will accept the programmed clock time and will add one
minute to the set clock.
Grease lter saturation alarm
After thirty fan functional hours, the display will show “Grease Filter” if the fan is active.
When this icon is shown in the display, the grease lters installed are required to be washed.
To reset the grease lter saturation alarm the user must press the “
” button for 5 seconds, after this
action the icon “Grease Filter” is not displayed, and the hood has the normal display operation.
Charcoal lter saturation alarm (Recirculating accessories)
After one hundred and twenty functional hours of the fan, the display will show “Charcoal Filter” if the fan
is active. When this icon ashes on display, the charcoal lters installed are required to be replaced or
reactivated.
To reset the charcoal lter saturation indication the user must press the “
” button for 5 seconds, after
this time the icon “Charcoal lter” is not displayed and the hood has the normal display operation.
Audible signal activation and deactivation
The audible signals can be activated or deactivated pressing the “Light” button for 5 seconds.
If the audible signal is activated, a tone must sound and the “Snd” symbol must appear on the display for
2 seconds.
If the audible signal is deactivated, the “Snd” symbol must appear on the display for 2 seconds and no
tone must sound.
Charcoal lter inclusion and exclusion (Recirculating accessories)
The charcoal lter inclusion or exclusion can be set by pressing the “ ” and “ ” buttons at the same
time for 5 seconds.
The Inclusion or exclusion of charcoal lter must be selected while the lamps and the motor are OFF.
When the charcoal lter has been excluded, the charcoal lter alarm is disabled.
Heat sensor
The control is equipped with a heat sensor that will turn on the blower at second speed if excessive heat
occurs (over 158° F or 70°C) surrounding the control area.
If the blower is OFF or if it is operating at rst speed, the blower will be set automatically to second speed,
the display shows the word “CARE” to indicate that heat sensor has detected an excessive heat.
During this state, the user may raise the blower speed to third speed but can not decrease the speed.
When the temperature level on the hood drops to normal, the blower will operate in the setting dened by
the user before the alarm occured.
18
Care and cleaning
For Best results
Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid.
It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.
Turn the blower on before starting to cook.
Use a rear burner when browning or pan frying meat.
Open a window or inside door slightly.
Clean the lters and the wall behind the lters frequently.
The blower should be turned on for a few minutes before cooking in order to establish air currents upward
through the hood. Thus when heat, smoke, moisture, grease and cooking odors are produced, they will
be carried outside instead of drifting into other rooms.
Use the low speeds for normal use and the higher speeds for strong odors or fumes.
Drafts across the range or cooktop will cause the escape of heat, smoke, moisture, grease and cooking
odors from the hood. Such drafts should be prevented in so far as possible.
The best job of ventilation in the kitchen is done where the only air currents are those created by the
blower itself.
For Gas Cooktops, a lower blower speed should be used if:
the gas ame is being distorted by the air movement.
the burner continually sparks (clicks)
the burner ame repeatedly blows out.
19
Care and cleaning
Care and Cleaning
The frequency of cleaning depends on the amount
and type of cooking.
Do not use the ventilating system without the
surfaces.
Always unplug or disconnect the appliance from the
power supply before servicing.
attempting to clean any part of the appliance.
Filters
The metal grease #lters are made of stainless steel
anodized aluminum and are long lasting.
To Remove The Metal Grease Filter
Turn the fan and lights o%.
Pull the spring release handle.
To Replace The Metal Grease Filters
Reverse procedure.
To Clean Filters
least once a month; they can be washed by hand
or in the dishwasher.
dry thoroughly before replacing it.
Lights
Before replacing the lamps, switch power off at
service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally.
Replace Lights
Remove the inner lamp lens cover by inserting a
slots and gently prying it free.
NOTE: Do not remove the outer trim ring (lamp
assembly).
Grasp the bulb and pull it straight out from the
lamp socket.
Follow package directions, wear gloves, do not
touch bulb with your bare ngers.
Replace inner cover by
inserting the three
retaining tabs into the
three slots and pressing
them rmly in place.
NOTE: Once you have replaced the light bulb,
make sure to put back the glass in its place.
Replace with 120 volt, 40 watt halogen bulbs with
a G9 base SUITABLE FOR USE IN OPEN
LUMINAIRES.
Bulb
NOTE: Turn off the lights and fan. Allow the
lights to cool before handling. Replace lights
per instructions. If new lights do not operate,
be sure lights are inserted correctly before
calling service.
The glass lens and inner trim ring are 2 pieces
loosetting. Be careful when removing the trim
ring that the glass lens does not fall out.
Outer
ring
Inner
ring
20
Clear and Cleaning
Optional Charcoal Filters
If the model is not vented to the outside, the air will be recirculated through disposable charcoal lters that
help remove smoke and odors.
The charcoal lters cannot be cleaned.
They must be replaced.
The charcoal lters are clipped inside of each metal grease lter (mounting instructions included with charcoal
lters kit).
The charcoal lters should be replaced every 4-6 months (depending on hood usage).
NOTE: DO NOT rinse, or put charcoal lters in an automatic dishwasher.
NOTE: Charcoal lters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width size.
Char coal lter placement (Recirculating accessories)
Fit the charcoal lter mattress on the upper side of each grease lter.
Use provided springs to x it in place.
Note: When removing for replacing for a new one do not remove Fixing Springs, simply pull out and rotate
outwards.
Cleaning
Always use the mildest cleaner that will do the
job. Use clean, soft cloths, sponges or paper
towels.
Rub stainless steel nishes in the direction of the
grain. Wipe area dry to avoid water marks.
After cleaning, place all parts in their proper
positions before using.
The cleaners recommended below indicate a type
and do not constitute an endorsement. Use all
products according to package directions.
Hood Surface
Painted Surfaces: For general care, wipe the outside
of the hood with sudsy water or household cleaners
such as Fantastic
®
or Formula 409
®
, rinse well and dry
with a clean soft cloth to avoid water marks.
Stainless Steel Surfaces: Wipe and dry stainless
steel in the same direction as the grain. Avoid using
too much pressure, which may mar the surface. To
remove nger prints and give added shine, use
cleaners such as Stainless Steel Magic. Do not allow
any cleaning compounds to remain in contact with
stainless steel for extended periods.
Plastic surfaces: Wipe with a moist soapy sponge.
Rinse and dry.
Aluminum Mesh Filters: Clean lters in the dish-
washer or by agitating in sudsy water. Ensure that
there is no soil trapped in the ne mesh. Dry the
lters before reinstalling them.
Anodized Aluminum surfaces: Top cap is not remov-
able. Wash top and underside with hot sudsy water.
Rinse and wipe dry or apply Fantastic
®
or Formula
409
®
rst to a clean sponge or paper towel and
wipe clean. DO NOT USE powdered cleaners or
steel wool pads.
Fixing
Spring
Charcoal
Filter
Grease
Filter
To p
Side
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Electrolux RH36WC60GS User manual

Category
Cooker hoods
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI