Architectural Decorative Vetro Downlight D01
Page 2 of 3 Compact Fluorescent
Certied test report no. 3533FR
Computed by LSI program **TEST-LITE**
SC(Along) = 1.3, SC(Across) = 1.5
Prepared For:
Lightolier
Fall River, MA
250
500
0°
30°
60°
90°
100
375
Calculite 6" Dia. Recessed Horizontal Vetro Downlight,
Cat.# 8031CL/D6A01
32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.
Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle Along 22.5 45 67.5 Across LMS
0 408 408 408 408 408
5 410 418 423 422 420 40
10 432 445 452 440 436
15 445 446 439 429 431 123
20 434 427 416 409 413
25 419 393 393 417 416 187
30 384 388 381 391 388
35 326 351 383 396 393 224
40 252 266 299 322 323
45 193 182 174 172 171 150
50 150 141 127 111 111
55 87 79 73 72 73 72
60 41 42 43 44 44
65 36 37 37 38 38 38
70 32 33 33 34 34
75 28 28 29 30 30 31
80 25 26 27 27 26
85 23 24 24 25 24 26
90 20 21 21 21 21
8031CL-D6AO1
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 350 14.60 39.31
0-40 574 23.92 64.42
0-60 796 33.19 89.37
0-90 891 37.14 100.00
40-90 317 13.22 35.58
60-90 94 3.95 10.63
90-180 0 .00 .00
0-180 891 37.14 100.00
** Efciency = 37.1% **
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .44 .44 .44 .44 .43 .43 .43 .43 .41 .41 .41 .40 .40 .40 .38 .38 .38 .37
1 .41 .40 .39 .37 .40 .39 .38 .37 .37 .37 .36 .36 .35 .35 .35 .34 .34 .33
2 .39 .36 .34 .33 .38 .36 .34 .32 .34 .33 .32 .33 .32 .31 .32 .31 .30 .30
3 .36 .33 .31 .29 .35 .32 .30 .29 .31 .30 .28 .31 .29 .28 .30 .28 .27 .27
4 .34 .30 .28 .26 .33 .30 .28 .26 .29 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .32 .28 .25 .23 .31 .27 .25 .23 .27 .24 .23 .26 .24 .23 .25 .24 .22 .22
6 .30 .26 .23 .21 .29 .25 .23 .21 .25 .22 .21 .24 .22 .20 .23 .22 .20 .20
7 .27 .23 .21 .19 .27 .23 .20 .19 .22 .20 .18 .22 .20 .18 .22 .20 .18 .18
8 .26 .21 .19 .17 .25 .21 .19 .17 .21 .18 .17 .20 .18 .17 .20 .18 .16 .16
9 .24 .20 .17 .15 .23 .19 .17 .15 .19 .17 .15 .19 .16 .15 .18 .16 .15 .14
10 .22 .18 .15 .14 .22 .18 .15 .13 .17 .15 .13 .17 .15 .13 .17 .15 .13 .13
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 36.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Luminance Summary - CD. / SQ. M.
Angle Mean CD/SQ M
45 13825
55 4359
65 4460
75 5694
85 13872
Calculite 6" Recessed Vetro Downlight, Cat.# 8021CL/D6A01
32W G.E. Biax T/E Triple Tube (Lower Position).
Lumen Rating = 2200 Lms. Universal Ballast #C2642UNVBES
Candlepower Summary
Angle Mean CP LMS. Angle Mean CP LMS.
0 459 90 20
5 448 44 95 17 15
10 489 100 3
15 526 146 105 2 2
20 524 110 2
25 487 223 115 2 2
30 426 120 2
35 356 222 125 2 2
40 274 130 2
45 178 138 135 2 1
50 85 140 2
55 45 48 145 2 1
60 39 150 2
65 34 34 155 2 1
70 31 160 2
75 27 29 165 2 1
80 24 170 2
85 22 24 175 2 0
90 20 180 2
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 413 18.77 44.29
0-40 634 28.84 68.05
0-60 820 37.32 88.03
0-90 907 41.26 97.35
40-90 273 12.42 29.30
60-90 86 3.95 9.31
90-180 24 1.12 2.65
0-180 932 42.39 100.00
** Efciency = 42.4% **
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .50 .50 .50 .50 .49 .49 .49 .49 .46 .46 .46 .44 .44 .44 .42 .42 .42 .41
1 .47 .46 .44 .43 .46 .45 .43 .42 .42 .42 .41 .41 .40 .39 .39 .38 .38 .37
2 .44 .42 .40 .38 .43 .41 .39 .37 .39 .38 .36 .38 .36 .35 .36 .35 .34 .34
3 .41 .38 .36 .34 .40 .37 .35 .33 .36 .34 .33 .35 .33 .32 .34 .33 .31 .31
4 .39 .35 .33 .30 .38 .35 .32 .30 .34 .31 .30 .33 .31 .29 .32 .30 .29 .28
5 .37 .33 .30 .28 .36 .32 .29 .27 .31 .29 .27 .30 .28 .27 .29 .28 .26 .26
6 .35 .30 .27 .25 .34 .30 .27 .25 .29 .26 .25 .28 .26 .24 .27 .26 .24 .23
7 .32 .28 .25 .23 .32 .27 .25 .23 .27 .24 .22 .26 .24 .22 .25 .23 .22 .21
8 .30 .26 .23 .21 .30 .25 .23 .21 .25 .22 .20 .24 .22 .20 .24 .22 .20 .19
9 .28 .24 .21 .19 .28 .23 .21 .19 .23 .20 .19 .22 .20 .18 .22 .20 .18 .18
10 .27 .22 .19 .17 .26 .22 .19 .17 .21 .19 .17 .21 .18 .17 .20 .18 .17 .16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Certied test report# 3494FR
Computed by LSI program **TEST-LITE**
SC = 1.0
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
8021CL-D6AO1
250
500
0°
30°
60°
90°
125
375