Miller XMT 425 C Owner's manual

Category
Welding System
Type
Owner's manual

This manual is also suitable for

Arc Welding Power Source
XMT 425 CC/CV
OM-257 182A 2012-02
Processes
Description
Multiprocess Welding
File: MULTIPROCESS
Visit our website at
www.MillerWelds.com
Auto-Line
CE
R
Thank you and congratulations on choosing Miller. Now you can get the
job done and get it done right. We know you don’t have time to do it any
other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior quality.
Like you, his customers couldn’t afford anything less. Miller products had
to be more than the best they could be. They had to be the best you could
buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy. With Miller you can
count on years of reliable service with proper maintenance. And if for
some reason the unit needs repair, there’s a Troubleshooting section that
will help you figure out what the problem is. The parts list will then help
you to decide which exact part you may need to fix the problem.
Warranty and service information for your particular model are also
provided.
Miller Electric manufactures a full line of
welders and welding related equipment. For
information on other quality Miller products, contact your local Miller
distributor to receive the latest full line catalog or individual catalog sheets.
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1.................................
1-1. Symbol Usage 1.......................................................................
1-2. Arc Welding Hazards 1.................................................................
1-3. Additional Symbols For Installation, Operation, And Maintenance 3.............................
1-4. California Proposition 65 Warnings 4......................................................
1-5. Principal Safety Standards 4.............................................................
1-6. EMF Information 4.....................................................................
SECTION 2 − DEFINITIONS 5..................................................................
2-1. Manufacturer’s Warning Label Definitions 5.................................................
2-2. WEEE Label (For Products Sold Within The EU) 7..........................................
2-3. Symbols And Definitions 7...............................................................
SECTION 3 − INTRODUCTION 8...............................................................
3-1. Important Information Regarding CE Products (Sold Within The EU) 8..........................
3-2. Serial Number And Rating Label Location 8................................................
3-3. Specifications 8........................................................................
3-4. Volt-Ampere Curves 9..................................................................
3-5. Duty Cycle And Overheating 10...........................................................
SECTION 4 − INSTALLATION 11................................................................
4-1. Selecting a Location 11..................................................................
4-2. Weld Output Terminals And Selecting Cable Sizes 12.........................................
4-3. Remote 14 Receptacle Information 13......................................................
4-4. 115 Volts AC Duplex Receptacle And Circuit Breakers 13......................................
4-5. Gas Valve Operation And Shielding Gas Connection 14.......................................
4-6. Electrical Service Guide 15...............................................................
4-7. Connecting 3-Phase Input Power 16.......................................................
SECTION 5 − OPERATION 17...................................................................
5-1. Front Panel Controls 17..................................................................
5-2. Meter Functions 18......................................................................
5-3. Mode Switch Settings 18.................................................................
5-4. Lift-Arc Trigger Hold TIG 19...............................................................
5-5. Stick Start Procedure 19.................................................................
SECTION 6 − MAINTENANCE & TROUBLESHOOTING 20.........................................
6-1. Routine Maintenance 20.................................................................
6-2. Blowing Out Inside Of Unit 20.............................................................
6-3. Voltmeter/Ammeter Help Displays 21.......................................................
6-4. Troubleshooting 21......................................................................
SECTION 7 − ELECTRICAL DIAGRAM 22........................................................
SECTION 8 − PARTS LIST 24...................................................................
WARRANTY
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
ITW Welding Products Italy S.r.l Via Privata Iseo 6/E, 20098 San Giuliano M.se, (MI) Italy declares that
the product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product Stock Number
XMT 425 CC/CV, W/GAS VALVE, AUTOLINE CE 907557003
Council Directives:
2006/95/EC Low Voltage
2004/108/EC Electromagnetic Compatibility
Standards:
IEC 609741 Arc Welding Equipment  Welding Power Sources: edition 3, 200507.
IEC 6097410 Arc Welding Equipment  Electromagnetic Compatibility Requirements: edition 2.0, 200708.
EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding, arc
welding and allied processes with the basic restrictions related to human exposure to electromagnetic fields
(0Hz300Hz)
EU Signatory:
February 20
th
, 2012
___________________________________________________________________________________
Massimigliano Lavarini Date of Declaration
ELECTRONIC ENGINEER R&D TECH. SUPPORT
956 142 934
OM-257 182 Page 1
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2011−10
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or ex-
plained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-
bols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shock
s
or severe burns. The electrode and work circuit i
s
electrically live whenever the output is on. The inpu
t
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automati
c
wire welding, the wire, wire reel, drive roll housing
,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperl
y
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoid-
able or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit volt-
age. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install, ground, and operate this equipment according to
its Owners Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
SIGNIFICANT DC VOLTAGE exists in inverter weld-
ing power sources AFTER removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on equip-
ment.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-257 182 Page 2
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
ARC RAYS can burn eyes and skin.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or by-
pass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off compressed gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EM
F)
can affect Implanted Medical Devices.
D Wearers of Pacemakers and other Implante
d
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their docto
r
and the device manufacturer before going near arc welding, spo
t
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient num-
ber of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
OM-257 182 Page 3
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manu-
ally lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can injure.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
BATTERY EXPLOSION can injure.
D Do not use welder to charge batteries or jum
p
start vehicles unless it has a battery chargin
g
feature designed for this purpose.
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform maintenance and service according to the Owners
Manuals, industry standards, and national, state, and local
codes.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained.
D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-257 182 Page 4
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Glob-
al Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Com-
bustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cga-
net.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, web-
site: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The Na-
tional Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may inter-
fere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, restrict access for passers−by or conduct individual risk as-
sessment for welders. All welders should use the following procedures
in order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recom-
mended.
OM-257 182 Page 5
SECTION 2 − DEFINITIONS
2-1. Manufacturers Warning Label Definitions
Kasjf;laksf;lkasdf'l;aksdf;lkasd;flksadflkasd;lk
Kasjf;laksf;lkasdf'l;aksdf;lkasd;flksadflkasd;lk
Kasjf;laksf;lkasdf'l;aksdf;lkasd;flksadflkasd;lk
179310-B
Warning! Watch Out! There are possible
hazards as shown by the symbols.
1 Electric shock from welding electrode
or wiring can kill.
1.1 Wear dry insulating gloves. Do not
touch electrode with bare hand. Do
not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by
insulating yourself from work and
ground.
1.3 Disconnect input plug or power before
working on machine.
2 Breathing welding fumes can be
hazardous to your health.
2.1 Keep your head out of the fumes.
2.2 Use forced ventilation or local exhaust
to remove the fumes.
2.3 Use ventilating fan to remove fumes.
3 Welding sparks can cause explosion
or fire.
3.1 Keep flammables away from welding.
Do not weld near flammables.
3.2 Welding sparks can cause fires. Have
a fire extinguisher nearby, and have a
watchperson ready to use it.
3.3 Do not weld on drums or any closed
containers.
4 Arc rays can burn eyes and injure
skin.
4.1 Wear hat and safety glasses. Use ear
protection and button shirt collar. Use
welding helmet with correct shade of
filter. Wear complete body protection.
5 Become trained and read the
instructions before working on the
machine or welding.
6 Do not remove or paint over (cover)
the label.
1 1.1 1.2 1.3 4 4.1
2 2.1 2.2 2.3
3 3.1 3.2 3.3
5
6
OM-257 182 Page 6
219335-C
>60s
V
V
V
1 Warning! Watch Out! There
are possible hazards as
shown by the symbols.
2 Electric shock from wiring can
kill.
3 Disconnect input plug or
power before working on
machine.
4 Hazardous voltage remains
on input capacitors after
power is turned off. Do not
touch fully charged
capacitors.
5 Always wait 60 seconds after
power is turned off before
working on unit, OR
6 Check input capacitor voltage,
and be sure it is near 0 before
touching any parts.
12 34 5 6
1 Warning! Watch Out! There
are possible hazards as
shown by the symbols.
2 When power is applied failed
parts can explode or cause
other parts to explode.
3 Flying pieces of parts can
cause injury. Always wear a
face shield when servicing
unit.
4 Always wear long sleeves and
button your collar when
servicing unit.
5 After taking proper
precautions as shown,
connect power to unit.
4/96
212073-C
1 23 4 5
179309-C
=
<
60°
1 Warning! Watch Out! There
are possible hazards as
shown by the symbols.
2 Falling equipment can cause
injury and damage to unit.
3 Always lift and support unit
using both handles. Keep
angle of lifting device less
than 60 degrees.
4 Use a proper cart to move
unit.
5 Do not use one handle to lift
or support unit.
1
2345
OM-257 182 Page 7
2-2. WEEE Label (For Products Sold Within The EU)
Do not discard product (where ap-
plicable) with general waste.
Reuse or recycle Waste Electrical
and Electronic Equipment (WEEE)
by disposing at a designated collec-
tion facility.
Contact your local recycling office
or your local distributor for further
information.
2-3. Symbols And Definitions
A
Amperage Panel
Alternating
Current (AC)
V
Voltage
Output Circuit Breaker Remote On
Off
Gas Tungsten Arc
Welding
Negative Voltage Input
Direct Current
(DC)
Positive Inductance
Protective Earth
(Ground)
Constant Current Constant Voltage Foot Control Line Connection
Arc Force
Shielded Metal Arc
Welding (SMAW)
Gas Metal Arc
Welding (GMAW)
Three Phase Static
Frequency Con-
verter-
Transformer-
Rectifier
U
0
Rated No Load
Voltage (Average)
U
1
Primary Voltage
U
2
Conventional
Load Voltage
X
Duty Cycle
Hz
Hertz
IP
Degree Of
Protection
I
2
Rated Welding
Current
%
Percent
Pulsed
Lift-Arc Trigger
Hold Operation
(GTAW)
Single Phase Three Phase
I
1ma
x
Rated Maximum
Supply Current
I
1eff
Maximum Effective
Supply Current
Increase
Lift-Arc Operation
(GTAW)
Scratch Start TIG
Voltage Sensing
Feeder
OM-257 182 Page 8
SECTION 3 INTRODUCTION
3-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
B. Information On Electromagnetic Compatibility (EMC)
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000−3−12 provided that the short−circuit power Ssc is greater than or equal to 2,055,437.437 at the interface
point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a supply with a short−circuit power Ssc greater than
or equal to 2,055,437.437.
ce-emc 1 2011-09
3-2. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
Operating Temperature Range: 14° F (-10° C) to 104° F (40° C). Ratings were developed at an ambient temperature of 20° C to 25° C.
3-3. Specifications
Input
Power
Rated
Output
Voltage
Range
in CV
Mode
Amperage
Range in
CC Mode
Max.
Open-
Circuit
Voltage
IP
Rating
RMS Amps Input at Rated Load Output,
60 Hz 3-Phase at NEMA Load Voltages
and Class I Rating
KVA KW
230 V 380 V 400 V 460 V
3-Phase 350 A at 34
VDC, 60%
Duty Cycle
10−38 V 5−425 A 75 VDC 23 36.1 22.3 20.6 17.8 14.2 13.6
*See Section 3-5 for Duty Cycle Rating.
OM-257 182 Page 9
3-4. Volt-Ampere Curves
217 836-A / 217 837-B
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of welding
power source. Curves of other set-
tings fall between curves shown.
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400 500
50%
75%
100%
25%
0%
AMPERAGE
VOLTS
A. CC Mode
GTAW
MAX
SMAW
MAX
SMAW
80A
ARC
CONTROL
GTAW
MN
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400 500
VOLTS
B. CV Mode
AMPERAGE
MAX
MIN
OM-257 182 Page 10
6 Minutes Welding 4 Minutes Resting
3-5. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or voltage, or duty cycle before
welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
60% Duty Cycle
Overheating
0
15
A or V
OR
Reduce Duty Cycle
Minutes
Ref. 219 523-A
OM-257 182 Page 11
SECTION 4 INSTALLATION
! Do not move or operate unit
where it could tip.
4-1. Selecting a Location
loc_2 3/96 - Ref. ST-151 556 / Ref. 956142883_2-A
1 Lifting Handles
Use handles to lift unit.
2 Hand Cart
Use cart or similar device to move
unit.
3 Line Disconnect Device
Locate unit near correct input
power supply.
! Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
24 in.
(610 mm)
17 in.
(432 mm)
12-1/2 in.
(318 mm)
Movement
1
2
Location
3
Dimensions And Weight
18 in.
(460 mm)
18 in.
(460 mm)
94.8 lb (43 kg)
1
OM-257 182 Page 12
4-2. Weld Output Terminals And Selecting Cable Sizes
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
30 m (100 ft) from the workpiece, the total cable length in the weld circuit is 60 m (2 cables x 30 m). Use the 60 m (200 ft) column to determine cable
size.
! Turn off power be
-
fore connecting to
weld output termi
-
nals.
! Do not use worn
,
damaged, under
-
sized, or poorly
spliced cables.
Weld Output
Terminals
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
30 m (100 ft) or Less
45 m
(150 ft)
60 m
(200 ft)
70 m
(250 ft)
90 m
(300 ft)
105 m
(350 ft)
120 m
(400 ft)
Welding
Amperes
10 − 60%
Duty
Cycle
mm
2
(AWG)
60 − 100%
Duty
Cycle
mm
2
(AWG)
10 − 100% Duty Cycle
mm
2
(AWG)
+
Output Receptacles
100 20 (4) 20 (4) 20 (4) 30 (3) 35 (2) 50 (1) 60 (1/0) 60 (1/0)
150 30 (3) 30 (3) 35 (2) 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 95 (3/0)
200 30 (3) 35 (2) 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0) 120 (4/0)
250 35 (2) 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x70
(2x2/0)
300 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x95
(2x3/0)
2x95
(2x3/0)
350 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x95
(2x3/0)
2x95
(2x3/0)
2x120
(2x4/0)
400 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x95
(2x3/0)
2x120
(2x4/0)
2x120
(2x4/0)
500 70 (2/0) 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x95
(2x3/0)
2x120
(2x4/0)
3x95
(3x3/0)
3x95
(3x3/0)
600 95 (3/0) 120 (4/0)
2x70
(2x2/0)
2x95
(2x3/0)
2x120
(2x4/0)
3x95
(3x3/0)
3x120
(3x4/0)
3x120
(3x4/0)
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
***For distances longer than those shown in this guide, call a factory applications representative. Milan Ref. S-0007-J 2011−07
OM-257 182 Page 13
4-3. Remote 14 Receptacle Information
AJ
B
K
I
C
L
NH
D
M
G
E
F
Socket* Socket Information
24 VOLTS AC
A 24 volts AC. Protected by supplementary protect-
or CB2.
B Contact closure to A completes 24 volts AC
contactor control circuit.
115 VOLTS AC
I 115 volts AC. Protected by supplementary pro-
tector CB1.
J Contact closure to I completes 115 volts AC
contactor control circuit.
REMOTE
OUTPUT
CONTROL
C Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D Remote control circuit common.
E 0 to +10 volts DC input command signal from
remote control.
M CC/CV select
A/V
AMPERAGE
VOLTAGE
F Current feedback; +1 volt DC per 100 weld am-
peres.
H Voltage feedback; +1 volt DC per 10 weld volts.
GND
G Circuit common for 24 and 115 volts AC circuits.
K Chassis common.
*The remaining sockets are not used.
Ref. 803 879-B
1 115 V 10 Amp. AC
Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 4-3).
2 Supplementary Protector CB1
3 Supplementary Protector CB2
CB1 protects duplex receptacle
and 115 volts AC portion of Remote
14 receptacle from overload.
CB2 protects 24 volts AC portion of
Remote 14 receptacle from
overload.
Press button to reset protector.
2 3
1
4-4. 115 Volts AC Duplex Receptacle And Supplementary Protectors
OM-257 182 Page 14
4-5. Gas Valve Operation And Shielding Gas Connection
Ref. 803 705-B / Ref. 803 879-B
Obtain gas cylinder and chain to
running gear, wall, or other station-
ary support so cylinder cannot fall
and break off valve.
1 Cylinder
2 Regulator/Flowmeter
Install so face is vertical.
3 Gas Hose Connection
Fitting has 5/8-18 right-hand
threads. Obtain and install gas
hose.
4 Gas In Fitting
5 Gas Out Fitting
The Gas In and Gas Out fittings
have 5/8-18 right-hand threads.
Obtain proper size, type, and length
hose and make connections as fol-
lows:
Connect hose from shielding gas
supply regulator/flowmeter to Gas
In fitting.
Connect hose coupler to torch.
Connect one end of gas hose to
hose coupler. Connect remaining
end of gas hose to Gas Out fitting.
Operation
The gas solenoid controls gas flow
during the TIG process as follows:
Remote TIG
Gas flow starts with remote contac-
tor on.
Gas flow stops at end of post−flow
if current was detected, or with re-
mote contactor off if no current was
detected.
Lift−Arc Trigger Hold TIG
Gas flow starts when output switch
is depressed.
Gas flow stops at end of post−flow.
Scratch Start TIG
Gas flow starts when current is de-
tected.
Gas flow stops at end of post−flow.
Post−flow time is factory set to 5
seconds per 100 amps of weld cur-
rent. The minimum post−flow time
is 5 seconds. The maximum post−
flow is 20 seconds (post flow set-
tings are not adjustable by the end
user).
4
3
1
2
GAS IN
GAS OUT
5
OM-257 182 Page 15
4-6. Electrical Service Guide
NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input
voltage.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
60 Hz Three Phase
Input Voltage (V) 230 380 400 460
Input Amperes (A) At Rated Output 36.1 22.3 20.6 17.8
Max Recommended Standard Fuse Rating In
Amperes
1
Time-Delay
2
40 25 25 20
Normal Operating
3
50 30 30 25
Min Input Conductor Size In AWG
4
10 12 12 14
Max Recommended Input Conductor Length In
Feet (Meters)
96
(29)
158
(48)
175
(53)
150
(46)
Min Grounding Conductor Size In AWG
4
10 12 12 14
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
Notes
OM-257 182 Page 16
4-7. Connecting 3-Phase Input Power
Ref. 802 136-A / Ref. 956142883_2-A
! Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
! Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.
! Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.
. The Auto-Line circuitry in this unit au-
tomatically adapts the power source
to the primary voltage being applied.
Check input voltage available at site.
This unit can be connected to any in-
put power between 208 and 575 VAC
without removing cover to relink the
power source.
See rating label on unit and check input
voltage available at site.
For Three-Phase Operation
1 Input Power Cord.
2 Disconnect Device (switch shown in
the OFF position)
3 Green Or Green/Yellow Grounding
Conductor
4 Disconnect Device Grounding
Terminal
5 Input Conductors (L1, L2 And L3)
6 Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1, L2, and L3
to disconnect device line terminals.
7 Overcurrent Protection
Select type and size of overcurrent protec-
tion using Section 4-6 (fused disconnect
switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
= GND/PE Earth Ground
L1
2
1
L2
L3
3
3
4
5
6
7
Tools Needed:
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Miller XMT 425 C Owner's manual

Category
Welding System
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI