User guide
DESIGN GUIDE
REVISED 8/ 2019
TABLE OF CONTENTS
3 CLASSIC REFRIGERATION
40 PRO REFRIGERATION
48 DESIGNER REFRIGERATION
58 WINE STORAGE
90 UNDERCOUNTER REFRIGERATION
100 SUB-ZERO WARRANTIES
Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
Throughout this guide, dimensions may vary by ±
1
/8" (3).
Dimensions in parentheses are millimeters unless otherwise
specied.
subzero.com | 3
CLASSIC REFRIGERATION
4 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Classic Refrigeration
For Classic refrigeration, Sub-Zero designers and engineers
took a fresh look at everything, inside and out. Exterior
renements include redesigned grilles and lower-prole
hinges. Inside, new technology in food preservation makes
Classic refrigeration nothing short of revolutionary.
CLASSIC MODELS
BI-36R BI-36RG BI-36F BI-30U BI-30UG BI-36U(ID) BI-36UG
BI-36UFD(ID) BI-42UFD(ID) BI-36S BI-42S(ID) BI-42SD BI-48S(ID)
B
I-48SD
subzero.com | 5
CLASSIC REFRIGERATION
Specications
INTERIOR CAPACITY—CU FT (L)
ALL REFRIGERATOR / ALL FREEZER REFR FRZR
BI-36R 23.5 (665)
BI-36RG 23.4 (663)
BI-36F 22.7 (643)
OVER-AND-UNDER REFR FRZR
BI-30U 13.2 (374) 4.2 (119)
BI-30UG 13.1 (371) 4.2 (119)
BI-36U(ID) 16.4 (464) 5.3 (150)
BI-36UG 16.3 (462) 5.3 (150)
BI-36UFD(ID) 15.7 (445) 5.3 (150)
BI-42UFD(ID) 17.9 (507) 6.3 (178)
SIDE-BY-SIDE REFR FRZR
BI-36S 12.4 (351) 8.2 (232)
BI-42S 16.3 (462) 8.0 (227)
BI-42SID 15.8 (447) 7.9 (224)
BI-42SD 16.0 (453) 7.9 (224)
BI-48S 19.1 (541) 9.8 (278)
BI-48SID 18.6 (527) 9.6 (272)
BI-48SD 18.8 (532) 9.6 (272)
6 | Sub-Zero Customer Care 800.222.7820
Classic Design Options
FRAMED
Choose framed custom door panels that contrast with
the stainless steel full-length handles and louvered grille
(shown). The framed application is an overlay model with
framed design features. Panel, grille, and handle options are
available.
Panels: Custom panels, stainless steel, or white enamel.
Grille: Classic louvered grille insert or solid custom panel
for 84" (standard), 83", or 88" overall unit height. Dual wide
grille for dual installations.
Handles: Full-length standard or extended handles.
OVERLAY
Custom overlay door panels can be combined with unique
handle hardware for design exibility. Shown with the pro
handle option to complement Wolf ranges. Customize with
panel, grille, and handle options.
Panels: Custom panels or stainless steel.
Grille: Solid custom panel or pro louvered grille for 84"
(standard), 83", or 88" overall unit height. Dual wide grille for
dual installations.
Handles: Custom, tubular, or pro handles.
CLASSIC REFRIGERATION
Overlay
Framed
subzero.com | 7
Classic Design Options
FLUSH INSET
The ush inset design option allows for ush door and
grille panels and custom handle hardware. Shown with the
tubular handle option to match Wolf built-in ovens. The ush
inset application is an overlay model with ush inset panels.
Customize with panel, grille, and handle options.
Panels: Custom panels or stainless steel.
Grille: Solid custom panel or pro louvered grille for 84"
(standard), 83", or 88" overall unit height. Dual wide grille for
dual installations.
Handles: Custom, tubular, or pro handles.
STAINLESS STEEL
Stainless steel models require no customization. To comple-
ment the look of Wolf ranges, choose the pro handle option
(shown). Grille and handle options are available.
Grille: Pro louvered grille for 84" (standard), 83", or 88"
overall unit height. Dual wide grille for dual installations.
Handles: Tubular or pro handles.
CLASSIC REFRIGERATION
Flush inset
Stainless steel
8 | Sub-Zero Customer Care 800.222.7820
Overall Dimensions
ALL REFRIGERATOR / ALL FREEZER
Model BI-36R, BI-36RG, BI-36F
CLASSIC REFRIGERATION
36"
(914)
84"
(2134)
4" (102)
73
3
/4"
(1873)
23
7
/8"
(606)
37
1
/4"
(946)
14
1
/8"
(359)
23
7
/
8
"
(606)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/2" (13)
26
3
/
16
"
(665)
Overall dimensions are based on stainless steel models.
For ush inset applications, add
1
/2" (13) to door clearance
dimensions.
subzero.com | 9
CLASSIC REFRIGERATION
Overall Dimensions
OVER-AND-UNDER
Model BI-30U, BI-30UG
30" (762)
84"
(2134)
4" (102)
50
3
/
4
"
(1289)
23"
(584)
23
7
/8"
(606)
23
5
/8"
(600)
31
1
/4"
(796)
12
1
/8"
(308)
26
3
/16" (665)
23
7
/8" (606)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/
2
"
(13)
Model BI-36U(ID), BI-36UG
36" (914)
84"
(2134)
4" (102)
50
3
/4"
(1289)
23"
(584)
23
7
/8"
(606)
23
5
/8"
(600)
37
1
/4"
(946)
23
7
/8" (606)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/
2
"
(13)
26
3
/16" (665)
14
1
/8"
(359)
10 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Overall Dimensions
OVER-AND-UNDER
Model BI-36UFD(ID)
36" (914)
84"
(2134)
4" (102)
50
3
/4"
(1289)
23"
(584)
23
7
/8"
(606)
23
5
/8"
(600)
19
1
/2"
(495)
8"
(203)
23
7
/8" (606)
HEIGHT DIMENSIONS ±
1
/
2
"
(13)
2
3
/8" (60)
26
3
/16" (665)
Model BI-42UFD(ID)
42" (1067)
84"
(2134)
4" (102)
50
3
/4"
(1289)
23"
(584)
23
7
/8"
(606)
22
1
/4"
(565)
9"
(229)
23
7
/8" (606)
HEIGHT DIMENSIONS ±
1
/2" (13)
2
3
/8" (60)
26
3
/16" (665)
23
5
/8"
(600)
subzero.com | 11
CLASSIC REFRIGERATION
Model BI-36S
36" (914)
84"
(2134)
4" (102)
73
3
/4"
(1873)
23
7
/8"
(606)
22
1
/4"
(565)
7
1
/4"
(184)
8
3
/4"
(222)
23
7
/8" (606)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/2" (13)
26
3
/16" (665)
Overall Dimensions
SIDE-BY-SIDE
Model BI-42S(ID), BI-42SD
42" (1067)
84"
(2134)
4" (102)
73
3
/
4
"
(1873)
23
7
/8" (606)
23
7
/8"
(606)
26
1
/4"
(668)
10
3
/8"
(264)
7
1
/2"
(191)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/2" (13)
26
3
/16" (665)
12 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Overall Dimensions
SIDE-BY-SIDE
Model BI-48S(ID), BI-48SD
48" (1219)
84"
(2134)
4"
(102)
73
3
/4"
(1873)
23
7
/8" (606)
23
7
/8"
(606)
30"
(762)
11
5
/8"
(295)
8
3
/8"
(213)
2
3
/8" (60)
HEIGHT DIMENSIONS ±
1
/2" (13)
26
3
/16" (665)
subzero.com | 13
Specications
SHIPPING WEIGHT
ALL REFRIGERATOR / ALL FREEZER LB (KG)
BI-36R 420 (191)
BI-36RG 430 (195)
BI-36F 406 (184)
OVER-AND-UNDER LB
(KG)
BI-30U 462 (210)
BI-30UG 476 (216)
BI-36U(ID) 515 (234)
BI-36UG 529 (240)
BI-36UFD(ID) 529 (240)
BI-42UFD(ID) 582 (264)
SIDE-BY-SIDE LB
(KG)
BI-36S 538 (244)
BI-42S 582 (264)
BI-42SID 608 (276)
BI-42SD 608 (276)
BI-48S 630 (286)
BI-48SID 656 (298)
BI-48SD 656 (298)
Shipping weights are based on stainless steel models.
CLASSIC REFRIGERATION
14 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Opening Dimensions
STANDARD INSTALLATION
3
/
4
"
(19)
TYPICAL
FRAMED
CABINETRY
W
FILLER
3
1
/
2
"
(89)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
/4" (19)
TYPICAL
3
1
/2" (89)
FINISHED
RETURN
NOTE:
3
1
/2" (89) finished returns will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit
.
83
3
/4"
(2127)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
FRONT VIEW
SIDE
VIEW
TOP VIEW
W
OPENING WIDTH
OPENING WIDTH
W
30" Model 29
1
/2" (749)
36" Model 35
1
/2" (902)
42" Model 41
1
/2" (1054)
48" Model 47
1
/2" (1206)
If an 83" (2108) grille height is specied, the opening height
must be decreased by
7
/8" (22). If an 88" (2235) grille height is
specied, the opening height must be increased by 4"
(102).
If two units are installed side by side, refer to page 16 for
dual standard installations.
subzero.com | 15
CLASSIC REFRIGERATION
Opening Dimensions
FLUSH INSET INSTALLATION
FLUSH INSET WIDTH
W
30" Model 32" (813)
36" Model 38" (965)
42" Model 44" (1118)
48" Model 50" (1270)
Flush inset is available for overlay models only.
Dimensions assume a
3
/4" (19) panel thickness.
If an 83"
(2108) grille height is specied, the ush inset
height must be decreased by
7
/8" (22). If an 88" (2235) grille
height is specied, the ush inset height must be increased
by 4"
(102).
If two units are installed side by side, refer to page 17 for
dual ush inset installations.
84"
(2134)
FLUSH
INSET
HEIGHT
1
/4"
(6)
26
3
/16"
(665)
FLUSH
INSET
DEPTH
2
3
/16"
(56)
NOTE:
3
1
/2" (89) finished returns and shaded areas will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit with
3
/4" (19) panel.
FRONT VIEW
SIDE
VIEW
TOP VIEW
1
1
/4"
(32)
W
FLUSH INSET WIDTH
FINISHED
CLEATS
5
11
/16"
(145)
FINISHED
RETURN
FILLER
FRAMED
CABINETRY
W
CLEAT
3
/4" (19)
TYPICAL
3
1
/2"
(89)
5
11
/
16
"
(145)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
1
/2"
(89)
CLEAT
3
/4" (19)
TYPICAL
16 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Opening Dimensions
DUAL STANDARD INSTALLATION
NOTE:
3
1
/2" (89) finished returns will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit
.
83
3
/4"
(2127)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
FRONT VIEW
SIDE
VIEW
TOP VIEW
W
OPENING WIDTH
3
/
4
"
(19)
TYPICAL
FRAMED
CABINETRY
W
FILLER
3
1
/
2
"
(89)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
/4" (19)
TYPICAL
3
1
/2" (89)
FINISHED
RETURN
A dual installation kit is required for this installation.
DUAL OPENING WIDTH
W
Two 30" Models 59
3
/4" (1518)
30" and 36" Models 65
3
/4" (1670)
Two 36" Models 71
3
/4" (1822)
subzero.com | 17
CLASSIC REFRIGERATION
Opening Dimensions
DUAL FLUSH INSET INSTALLATION
84"
(2134)
FLUSH
INSET
HEIGHT
1
/4"
(6)
26
3
/16"
(665)
FLUSH
INSET
DEPTH
2
3
/16"
(56)
FRONT VIEW
SIDE
VIEW
TOP VIEW
FINISHED
CLEATS
1
1
/4"
(32)
W
FLUSH INSET WIDTH
NOTE:
3
1
/2" (89) finished returns and shaded areas will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit with
3
/4" (19) panel.
5
11
/16"
(145)
FINISHED
RETURN
FILLER
FRAMED
CABINETRY
W
CLEAT
3
/4" (19)
TYPICAL
3
1
/2"
(89)
5
11
/
16
"
(145)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
1
/2"
(89)
CLEAT
3
/4" (19)
TYPICAL
Flush inset is available for overlay models only.
Dimensions assume a
3
/4" (19) panel thickness. A dual instal-
lation kit is required for this installation.
DUAL FLUSH INSET WIDTH
W
Two 30" Models 62
1
/4" (1581)
30" and 36" Models 68
1
/4" (1734)
Two 36" Models 74
1
/4" (1886)
18 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
Plumbing Requirements
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with the installation of the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided stainless
steel, or PEX tubing
Pressure 35–120 psi
(2.4–8.3 bar)
Excess Line for Connection 36" (914)
Electrical Requirements
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Electrical supply location
3" (76)
18" (457)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location
subzero.com | 19
FRAMED PANELS
The framed application is an overlay model with framed
design features. It is not a separate model.
If the custom panel is thinner than
1
/4" (6), a ller material
must be added to achieve a proper t. If the panel is thicker
than
1
/4" (6), rout an edge around the panel or mount the
custom panel on a sheet of
1
/4" (6) thick material and insert
into the channel. Refer to the illustrations below.
Routing, recessing, or optional extended handles may be
required for nger clearance. Refer to the full-scale template
on page 34.
When installing two units side by side, refer to page 16 for
dual standard installations.
Custom Panels
For framed, overlay, and ush inset applications, custom
door panels must be provided. Handle hardware must also
be provided for overlay and ush inset applications. Refer
to Panel Requirements below and the charts on pages
22–27 for custom panel dimensions for your specic design
application.
IMPORTANT NOTE: Do not cover a glass door with a solid
panel.
Finish all sides of the custom panels. They may be visible
when the door is open or through the window of glass door
models.
PANEL REQUIREMENTS
WEIGHT PER PANEL MAX
BI-36R, BI-36RG, BI-36F 75 lb (34 kg)
All Other Models 50 lb (23 kg)
Grille Panel 13 lb (6 kg)
PANEL THICKNESS MIN
Framed
1
/4" (6)
Overlay and Flush Inset
5
/8" (16)
CLASSIC REFRIGERATION
DOOR
1
/4" (6) TRIM REVEAL
1
/4" (6) PANEL
1
/4" (6) min
ROUT TO
1
/4" (6)
DOOR
Panel
1
/4" thick or less
Panel thicker than
1
/4"
20 | Sub-Zero Customer Care 800.222.7820
CLASSIC REFRIGERATION
PANEL MOUNTING KIT
The Sub-Zero custom panel mounting kit eliminates the need
for the backer and spacer panels and is avail able through an
authorized Sub-Zero dealer. For local dealer information, visit
the nd a showroom section of our website, subzero.com.
The kit consists of mounting cleats, screws, and gages used
to properly position the cleats. The kit is available for all
Classic models except glass door models. Dual installations
require two mounting kits.
OVERLAY PANELS
Overlay panels are typically created by combining a
3
/4" (19)
custom panel, a .10"
(3) spacer panel, and a
1
/4" (6) backer
panel. Refer to the illustrations below.
When installing two units side by side, refer to page 16 for
dual standard installations.
1
/8" (3) (OVERLAY)
CUSTOM PANEL
SPACER PANEL
BACKER PANEL
TRIM
5
/16" (8) min
1
/4" (6)
.10" (3)
CUSTOM
PANEL
SPACER
PANEL
BACKER
PANEL
3
/4"
(19)
typical
Panel assembly (cross section)
Panel assembly (rear view)
Custom Panels
PARTIAL FRAMED OPTION
The partial framed kit includes a stainless steel panel for
above and below the external dispenser. Refer to the chart
below for panel width. The kit is avail able through an autho-
rized Sub-Zero dealer. For local dealer information, visit the
nd a showroom section of our website, subzero.com.
PARTIAL FRAMED PANEL
W
BI-42SD 15
1
/16" (383)
BI-48SD 18
3
/4" (476)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102

Sub-Zero UC-24BG/O User guide

Type
User guide

Ask a question and I''ll find the answer in the document