Take the following into consideration before you install this product:
• Due to the size and mass of this product, it is important that the Backbox is safely installed according to these installation
instructions.
• Make sure that the type of wall is capable of supporting the system and use screws that are suitable for that type of wall.
• The system must be installed by qualified personnel in accordance with state and local building regulations.
• Also see the Install the DX80 Phone to Enclosure (on the other page).
• Locate the provided Security Torx Driver Bit (usually taped right next to the Hookswitch on the Faceplate).
• Tool required to remove Security Torx Screws (an Electric Hand Drill or Powered Screwdriver)
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Hookswitch Wires to USB to Analog Audio Module Connections
Contacting CyberData
Black Wire
USB - B Plug
on DX80
USB - A to B Cable
1
2
3
4
6
7
8
Plug in to Connector Panel
Plug in to (J1)
USB - A Plug
J4
J1
Red Wire
FACTORY DISCONNECTED
RECONNECT BEFORE FASTEN
FACEPLATE TO BACKBOX
***
ASSEMBLY
HOOKSWITCH
Red Wire to J4 (Position 5)
Black Wire to J4 (Position 9)
5
9
& WIRES TO SOCKET
SOCKET
PLUG
FACTORY PRE-INSTALLED
WIRES TO PLUG
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Backbox Mounting Holes Dimensions
Armored Cord Handset to USB to Analog Audio Module
27.559 [700.00]
19.685 [500.00]
9.843 [250.00]
1.969 [50.00]
9.114 [231.50]
6.690 [169.92]
4.016 [102.00]
Approx.
5.118 [130.00]
2.047 [52.00]
2.421 [61.50]
12.567 [319.19]
22.953 [583.00]
9.114 [231.50]
2.047 [52.00]
5.118 [130.00]
16.929 [430.00]
Front
Bottom
Rear
Front
Left
Rear
Rear
Top
Front
Right
Front
Top
Top
Top
ø1.160 [ø29.50]
1.230 [31.25]
Hole Diameter
Typical EMT Fitting
4
Knock Out
Knock Out
ø0.63 [ø16.0]
ø0.41 [ø10.5]
Tool Required to Remove
1) Hammer
2) Screwdriver
Knock Out:
2
One Inch Conduit
EMT Fitting
Conduit Hole Fits
(One on Each Side)
ø1.30 [ø33.0]
1
3
Knock Out
Knock Out
Knock Out
View Shown with
Hole Plug Installed
Open Faceplate
then Remove Fastener
from the Inside
Tool Required to Remove
1) 3/8” Socket / Wrench
or 9mm Socket / Wrench
Nut Behind:
Notes:
1) Dimensions are in Inches [Millimeter]
2) Mounting Holes Fit Up to 1/4" Square Neck Carriage Bolt, 1/4" Self-Tapping or 10 Millimeter Machine Screw
3) 1" EMT Fitting is not provided.
Red Wire to J4 (Position 1)
Green Wire to J4 (Position 3)
Black Wire to J4 (Position 4)
Yellow Wire to J4 (Position 2)
J4
1
2
3
4
5
9
1) #00 size Phillips Screw Driver
Tool Provided for Terminal Block Screw:
6
7
8
Armored Cord Wires End
The IP Endpoint Company
Installation Quick Reference
DX80 Secure Phone