PCE POE 10 User manual

Category
Multimeters
Type
User manual

PCE POE 10 is a professional cable tester with PoE functions, which enables you to test and analyze your PoE switches, cables, and devices conveniently and efficiently. You can quickly identify and locate faults in your network infrastructure, ensuring a stable and reliable data transmission. The PoE power test helps you to measure the power consumption of your PoE devices accurately. Furthermore, the loop-back test allows you to verify the functionality of individual ports on switches or end devices.

PCE POE 10 is a professional cable tester with PoE functions, which enables you to test and analyze your PoE switches, cables, and devices conveniently and efficiently. You can quickly identify and locate faults in your network infrastructure, ensuring a stable and reliable data transmission. The PoE power test helps you to measure the power consumption of your PoE devices accurately. Furthermore, the loop-back test allows you to verify the functionality of individual ports on switches or end devices.

© PCE Instruments
PCE-POE 10 Cable Tester
User Manual
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 3 February 2021
v1.0
English
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
2.1 Delivery scope.................................................................................................................. 2
3 Device description ................................................................................ 3
3.1 Main menu ....................................................................................................................... 4
3.2 PoE switch test................................................................................................................. 4
3.3 PoE power test ................................................................................................................. 6
3.4 Cable test functions .......................................................................................................... 6
3.5 Power test function ........................................................................................................... 8
3.6 Loop-back test.................................................................................................................. 8
3.7 Lighting function ............................................................................................................... 8
3.8 Settings ............................................................................................................................ 9
4 Warranty ............................................................................................... 10
5 Disposal ............................................................................................... 10
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The
device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to
the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.
© PCE Instruments
2
2 Specifications
Transmitter specifications
Display
Continuity test
Cable types
STP and UTP
Maximum cable length
600 m
Connection type
Transmitter + remote
control
Transmitter + switch/
router
PoE functions
Measurement range
DC 5 ... +60 V POE
switch
Standard identifier
802.3af/at (standard /
no standard)
Power measurement
range
0 … 18 W
Measurement functions
Voltage measurement
range
DC 0 ... +60 V
Current measurement
range
0 … +3 A
Power measurement
range
0 … 180 W
Max. input power
DC 48 V 5 mA
Max. Input current
Loop-back test
Power supply
Receiver specifications
Connection
Function
2.1 Delivery scope
1 x PCE-POE 10 transmitter
1 x PCE-POE 10 receiver
3 x 1.5 V AAA battery
1 x RJ45 test cable
1 x RJ11 test cable
1 x RJ11 test adaptor with alligator clip
1 x user manual
1 x transport bag
© PCE Instruments
3
3 Device description
1. Light
6. On/off switch
11. Arrow key right
2. PoE test connection
7. DC Out
12.OK
3. RJ-45 loop back connector
8. DC In
13.RJ45 connection
for cable test functions
4. RJ-45 connector
for cable test functions
9. Arrow key left
5. Light ON/OFF
10.Back key
© PCE Instruments
4
3.1 Main menu
POE: POE switch test and POE performance test
CONT: Cable test functions
POWER: Voltage and current measurement between the PSE and the PD and calculation of the
power consumption
LOOP: Perform loop back test
SET: Setting of language, backlight time, automatic power-off, display contrast and display
of the software version
3.2 PoE switch test
Connect a network cable between the PoE switch and the PCE-POE 10 (RJ45 connection 2, see
above). The correct connection is signalled by means of the measured voltage on the display of
the PCE-POE 10. Press "Enter" to start the test. The result is then displayed on the screen.
3.2.1 Standard PoE switch:
If the PoE switch being tested is a standard PoE switch, the test result is displayed as follows:
© PCE Instruments
5
3.2.2 Non-standard PoE switch:
If the PoE switch being tested is a non-standard PoE switch, the test result is displayed as follows:
3.2.3 Connect Error
If the error message "Connect Error" appears, it is possible that additional POE end devices are
connected to the POE switch to be tested. Disconnect the cable connection of these devices
and repeat the test.
3.2.4 Unconnected
If the error message "Unconnected" appears on the display, no compatible POE switch has
been detected.
© PCE Instruments
6
3.3 PoE power test
For the PoE power test, a PoE switch and a PoE end device device (e. g. PoE camera) must be
connected to the PCE-POE 10. After successful connection, a voltage value is displayed on the
screen. A few seconds later, the meter automatically switches to the power test. The display
information is shown in the following picture.
As soon as all measured power parameters are displayed, you can start the identification of the
PSE by pressing the Enter key. If the message "Non Standard" appears on the display, the
connected PSE does not comply with the current standards; if no message appears on the
display, the connected PSE complies with the current standards.
3.4 Cable test functions
This function can be used to find short circuits, open and crossed wire pairs in the connected
network cable. To do this, connect the network cable to be tested to the RJ45 connector 4 and
the receiver supplied to the other end of the cable.
The connected network cable can be an 8-core UTP or a 9-core STP network cable.
If the cables are intact, one of the following screens will appear on the PCE-POE 10:
3.4.1 Short circuit
If a short circuit is detected in the connected cable, the following appears on the display of the
PCE-POE 10 (example):
(Wires 1&2 and 4&5 are short-circuited)
© PCE Instruments
7
3.4.2 Open wire pairs
If the PCE-POE 10 detects open wire pairs in the connected network cable, the following screen
is displayed (example):
(cores 5 and 8 are open)
3.4.3 Crossed wire pairs
If crossed wire pairs are detected in the connected network cable, the following appears on the
display of the PCE-POE 10 (example):
(cores 1&8 and 5&6 are crossed)
3.4.4 Cable open
If the message "Cable open" appears on the display of the PCE-POE 10, this may be due to the
following reasons:
1. The connected network cable actually has a breakage.
2. The connected network cable is not correctly connected to the transmitter.
3. The connected network cable is not correctly connected to the receiver.
© PCE Instruments
8
3.5 Power test function
This function can be used to measure the power consumption of the PSE or PD. To do so, use
sockets 7 and 8 on the right-hand side of the PCE-POE 10. The mains adaptor of the PSE or
PD is connected to the "DC IN" input and the PSE or PD itself to the "DC OUT" output.
3.6 Loop-back test
The loop-back test can be used to test individual ports on a switch or end device. The PCE-POE
10 sends data packets and attempts to receive them again at the same time. If the test is
successful, the status LEDs on the port to be tested light up. Connect a network cable to the loop-
back connector of the PCE-POE 10 and to the port to be tested.
3.7 Lighting function
Press the light key to switch the LED on or off.
© PCE Instruments
9
3.8 Settings
3.8.1 Language
At present, the menu navigation of the unit is only available in English.
3.8.2 Backlight
The backlight time can be set between 15 s, 30 s, 60 s, On and Off.
3.8.3 Automatic power-off
The automatic power-off of the meter can be set at intervals of 15, 30 and 60 minutes or
disabled by selecting "off".
3.8.4 Display contrast
The display contrast can be changed between 20 and 35 with the arrow keys.
3.8.5 Software version
This menu item displays the hardware / software version of the unit.
© PCE Instruments
10
4 Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
5 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament
applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use
them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with
your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
11
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 4 23, rue de Strasbourg Calle Mayor, 53
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Deutschland France España
Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548
Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542
www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti.
Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah.
Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C
Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul
United Kingdom, SO31 4RF Italia Türkiye
Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47
Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93
www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands China Hong Kong
PCE Brookhuis B.V. PCE (Beijing) Technology Co., Limited PCE Instruments HK Ltd.
Institutenweg 15 1519 Room, 6 Building Unit J, 21/F., COS Centre
7521 PH Enschede Zhong Ang Times Plaza 56 Tsun Yip Street
Nederland No. 9 Mentougou Road, Tou Gou District Kwun Tong
Telefoon: +31 (0)53 737 01 92 102300 Beijing, China Kowloon, Hong Kong
[email protected] Tel: +86 (10) 8893 9660 Tel: +852-301-84912
www.pce-instruments.com/dutch info@pce-instruments.cn [email protected]
www.pce-instruments.cn www.pce-instruments.cn
United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 (561) 320-9162
Fax: +1 (561) 320-9176
www.pce-instruments.com/us
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

PCE POE 10 User manual

Category
Multimeters
Type
User manual

PCE POE 10 is a professional cable tester with PoE functions, which enables you to test and analyze your PoE switches, cables, and devices conveniently and efficiently. You can quickly identify and locate faults in your network infrastructure, ensuring a stable and reliable data transmission. The PoE power test helps you to measure the power consumption of your PoE devices accurately. Furthermore, the loop-back test allows you to verify the functionality of individual ports on switches or end devices.

Ask a question and I''ll find the answer in the document