ELSYS EMS is a versatile LoRaWAN® sensor that measures temperature, humidity, detects water leaks, opening activity, and acceleration. With its long battery life of up to 10 years and easy installation, it's ideal for monitoring various indoor environments, including homes, offices, and warehouses.

ELSYS EMS is a versatile LoRaWAN® sensor that measures temperature, humidity, detects water leaks, opening activity, and acceleration. With its long battery life of up to 10 years and easy installation, it's ideal for monitoring various indoor environments, including homes, offices, and warehouses.

Operating Manual
Publish Date: 30.11.2022
Wireless sensor
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2020
Operating Manual
EMS
Operating Manual EMS
2
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer, Elektroniksystem i
Umeå AB will not be held responsible for any loss or damage resulting from not
following the instructions of this operating manual.
The device must not be dismantled or modified in any way.
The device is only intended for indoor use. Do not expose it to moisture.
The device is not intended to be used as a reference sensor, and
Elektroniksystem i Umeå AB will not be held liable for any damage which
may result from inaccurate readings.
The battery should be removed from the device if it is not to be used for
an extended period. Otherwise, the battery might leak and damage
the device. Never leave a discharged battery in the battery
compartment.
The device must never be subjected to shocks or impacts.
To clean the device, wipe with a soft moistened cloth. Use another soft,
dry cloth to wipe dry. Do not use any detergent or alcohol to clean the
device.
Disposal note in accordance with ElektroG and WEEE Directive
2012/19/EU
The device, as well as all the individual parts, must not be disposed of
with household waste or industrial waste. You are obliged to dispose of the
device at the end of its service life in accordance with the requirements of
ElektroG in order to protect the environment and to reduce waste through
recycling. For additional information and how to carry out disposal, please
contact the certified disposal service providers. The sensors contain a lithium
battery, which must be disposed of separately.
Operating Manual EMS
3
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Contents
Important safety information .......................................................................................................... 2
Description......................................................................................................................................... 4
Main features of EMS ................................................................................................................. 5
Installation .......................................................................................................................................... 6
Door activity sensor .................................................................................................................... 7
Water leak sensor ........................................................................................................................ 7
Temperature/humidity sensor ................................................................................................... 7
Sensor configuration ........................................................................................................................ 8
NFC Configuration ....................................................................................................................... 8
Over the air configuration .......................................................................................................... 8
Application parameters............................................................................................................... 8
Sensor behavior ................................................................................................................................ 9
NFC Read / Write ........................................................................................................................ 9
Sensor startup ........................................................................................................................... 10
Sampling mode / Periodic measurement ............................................................................. 11
Opening activity (Reed switch) .............................................................................................. 11
Schedule Transmission............................................................................................................. 12
Water leak detector ................................................................................................................... 12
Specifications .................................................................................................................................. 13
Sensor payload format ............................................................................................................. 13
Regulations ...................................................................................................................................... 14
Legal Notices ............................................................................................................................. 14
Federal Communication Commission Interference Statement .......................................... 14
Declaration of conformity ........................................................................................................ 16
Operating Manual EMS
4
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Description
EMS is a subtle indoor sensor with multiple purposes for LoRaWAN® wireless
network. It measures temperature and humidity but can also be used as water
leak detector, door activity sensor or acceleration detector. EMS is designed to
be mounted on door frames, under desks, under dishwashers or in any other
limited surface area. EMS is equipped with NFC (Near Field Communication)
and can easily be configured from a smartphone.
The barcode contains DevEUI and sensor type. This label is located at the back
of your device.
Operating Manual EMS
5
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Main features of EMS
Compatible with LoRaWAN® specification 1.0.3
Measures ambient temperature
Measures ambient humidity
Detects acceleration
Detects water leak
Detects opening activity (Reed Switch)
Easy installation
Easy configuration
May be installed on any flat surface
Battery-powered
Long-range communication
Configurable over NFC
Configurable over the air
Ten years of battery life*
Supported channel plans: US902-928, EU863-870, AS923, AU915-
928, KR920-923, RU864, IN865 & HK923
CE Approved and RoHS compliant
*Depending on settings and environmental factors
Operating Manual EMS
6
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Installation
1. Remove the back panel of the sensor with a small screwdriver.
2. Install the battery. The EMS requires one AA battery. The battery type is
3.6V Lithium Battery (ER14505).
Caution: Using batteries other than the ones provided may result in loss of performance and
battery life, and also damage to the device. Dispose of properly, observing environmental
protection rules.
3. Mount the back panel on the surface using the adhesive tape.
4. Attach the cover to the back panel.
Operating Manual EMS
7
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Door activity sensor
Make sure that the magnet part is mounted on the door (the part that is going to
open) and the sensor part is mounted on the frame. For double doors, put one part on
each door.
The distance between magnet and sensor should, if possible, not exceed 10mm. Make
sure that the magnet and reed switch are mounted next to each other. Detection range
will be affected by the materials of the door and frame, different materials result in
different ranges. The reed switch is on the end of the sensor
without
the stripe. The
magnet needs to face this side of the sensor (see image).
Water leak sensor
Make sure that the back panel is mounted on the surface where the water may leak. The
sensor element that detects the leak is placed on the back panel. For example, if EMS is
going to monitor water leak from a dishwasher, place the back panel onto the floor
under the machine.
Temperature/humidity sensor
Place the device in an open space on a wall, under a desk or on any other flat surface.
Make sure that the sensor is not faced by direct sunlight or placed near air vents or
other places where it may measure values that is not representative for the rest of the
room.
Operating Manual EMS
8
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Sensor configuration
All sensor settings can be configured via a smartphone application with NFC
(Near Field Communication) or over the air via the network server and downlink
data to the sensor. The sampling rate, spreading factor, encryption keys, port,
and modes can be changed. All sensor settings can be locked from the server or
NFC to make end-users unable to read or change settings on the sensor.
NFC Configuration
1. Download ELSYS Sensor Settings application from Google Play and install
it on a smartphone or tablet. The device must support NFC.
2. Enable NFC on the device and start the application.
3. Place your device on top of the EMS sensor to connect with the NFC
antenna.
You may need to remove the top cover and battery to get connection.
4. Remove the device. Current settings will be displayed in the application.
5. Use the application to change any settings if needed.
6. Quickly tap the device on top of the EMS to give the new settings to the
sensor. Make sure that the application confirms your new settings.
7. Wait for the sensor to reboot (5 sec), indicated by the LED flashing. Sensor
settings have been updated.
See the section Help in the application for more information.
Over the air configuration
All settings may be configured over the air via your LoRaWAN® infrastructure.
Please visit the support section on our webpage for more information regarding
downlink protocol.
Application parameters
All parameters for the “Sensor settings” application can be found in our settings
document. Please visit the support section on our webpage for more information.
Operating Manual EMS
9
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Sensor behavior
NFC Read / Write
1. When reading or writing NFC
configuration data to the sensor, it starts
a timer and delays its action 5 seconds.
2. After the delay, the sensor determines if
the NFC data has changed or not. If the
data has changed, the sensor reboots
and starts from power-up.
3. Write your settings in the application
and then locate the NFC antenna of the
phone and sensor. Keep the two
devices close and dont move them to
get the best connectivity as possible
when writing or reading data to the
sensor. Bad connection can be caused
by long distance, wrong location, or
rapid movement.
4. When you have written data to the sensor, let the sensor reboot and restart
before trying to write again.
You should always validate your settings by reading the NFC data after the
sensor has restarted.
Operating Manual EMS
10
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Sensor startup
1. When the sensor starts up, it loads
configuration from the internal memory and
merges it with user configuration.
2. When the configuration is done, the sensor
writes the new settings to the NFC chip. The
sensor always writes new configurations to the
NFC chip when something changes in the
sensor or if NFC data is corrupted by an NFC
writer or phone. The sensor always writes the
new configuration to NFC chip at startup.
3. When the configuration is done, the sensor
tries to join the network if OTAA (Over the Air
Activation) is enabled.
4. The sensor LED flashes orange when it tries to
join a network. It will try to join every 10
seconds initially. This interval will increase to
save battery, at most up to one time per hour.
5. After successful connection to a network, the
sensor sends a settings packet and enters
sampling mode.
Operating Manual EMS
11
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Sampling mode / Periodic
measurement
The sensor makes periodic
measurements according to the user
configurations.
Opening activity (Reed switch)
When the reed switch changes state from
closed to open, the activity is added to a
pulse counter that keeps track of the
number of opening events. The number
of the pulse counter and the current
state is added to the data packet.
If the state is changed from closed to
open, the pulse counter remains
unchanged and only the state and
current number of counts is added to the
data packet.
After values has been added to the
packet, the EMS schedules a
transmission.
Operating Manual EMS
12
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Schedule Transmission
The sensor transmits the data
according to the user
configurations.
Note: The configured sending interval can
be overridden by network limitations. Due
to this, the spreading factor and sending
interval settings might result in longer
intervals than intended.
Water leak detector
The EMS has probes mounted through the back panel which are constantly
monitored by the sensor. The sensor can be configured to send alarm
immediately when water is detected. Detection is sent periodically. Value is 0 for
dry conditions and 1 when water is detected.
Operating Manual EMS
13
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Specifications
Sensor payload format
The device uses the standard ELSYS payload format. Please see the specified
document on our webpage.
Power supply:
3.6V DC
Battery type:
AA 14505 (Li-SOCI2)
EU directives compliance:
RoHS 2011/65/EU
WEEE 2012/19/EU
Radio protocol:
LoRaWAN®
Radio frequency band:
US902-928, EU863-870, AS923,
AU915-928, KR920-923, RU864,
IN865 & HK923
Range:
8 km*
Operating conditions
0 to 50 °C
0 to 85 % RH (non-condensing)
Temperature range
0 40 °C
Temperature resolution
0.1 °C
Temperature accuracy
± 0.2 °C
Humidity range
0 100 %
Humidity resolution
0.1 % RH
Humidity accuracy
± 2 % RH
Accelerometer detection level
Configurable via NFC and downlink conf.
Water leak detector range
0 100 % (Represented by numbers 0 254)
Dimensions
21.2 x 74.9 x 21.8 mm
Battery life
Up to 10 years**
*Measured with settings: SF10, 868 Mhz. The range can be greater or less, depending on terrain and building
structure.
**Depending on settings and environmental factors.
Operating Manual EMS
14
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Regulations
Legal Notices
All information, including, but not limited to, information regarding the features,
functionality, and/or other product specification, are subject to change without
notice. ELSYS reserves all rights to revise or update its products, software, or
documentation without any obligation to notify any individual or entity. ELSYS
and ELSYS logo are trademarks of Elektroniksystem i Umeå AB. All other brands
and product names referred to herein are trademarks of their respective holders.
Federal Communication Commission Interference Statement
NOTICE:
This device complies with Part 15 of the FCC Rules and with Industry Canada
licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d'en compromettre le fonctionnement.
Operating Manual EMS
15
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
Radiofrequency radiation exposure Information:
This equipment complies with FCC and Innovation, Science and Economic Development
radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance of 20 cm
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Informations sur l'exposition aux rayonnements radiofréquences:
Cet équipement est conforme à la réglementation de la FCC et aux limites d'exposition
aux rayonnements définies par Innovation, Sciences et Développement économique pour
un environnement non contrôlé.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le
radiateur et votre corps.
Cet émetteur ne doit pas être co-localisé ou fonctionner en conjonction avec une autre
antenne ou un autre émetteur.
FCC ID: 2ANX3-EMS01 IC ID: 26904-EMS01
NOTICE:
Changes or modifications made to this equipment not expressly approved by
Elektroniksystem i Umeå AB may void the FCC authorization to operate this
equipment.
Operating Manual EMS
16
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: support@elsys.se ǀ Web: www.elsys.se
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Declaration of conformity
Hereby, Elektroniksystem i Umeå AB declares that EMS complies with the
essential requirements and other relevant provisions of Directive 2014/30/EU
and 2014/53/EU.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

ELSYS EMS User manual

Type
User manual

ELSYS EMS is a versatile LoRaWAN® sensor that measures temperature, humidity, detects water leaks, opening activity, and acceleration. With its long battery life of up to 10 years and easy installation, it's ideal for monitoring various indoor environments, including homes, offices, and warehouses.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI