MULTISPAN PFLC-68 Owner's manual

Type
Owner's manual
Packaging FLC
MENU ENT
RST
P-FLC 68
P-FLC-68
PACKAGING CONTROLLER AUXILIARY SUPPLY:
Supply voltage
Power consumption
(VA RATING) Approx 6 VA
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
24V DC
TECHNICAL SPECIFICATION
MECHANICAL INSTALLATION
Input (Start Pulse)
Display
Size
Keys
Panel Cutout
320 x 240 px Resistive Touch screen
Display
96 (H) x 96 (W) x 52 (D) mm
RESET
92 (H) x 92 (W) mm
DISPLAY AND KEYS:
DIMENSION:
Clutch Proxy
Unwinding Motor Start Proxy
Eye Mark Sensor Proxy
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
Relay Type
Rating
8 nos
RLY-1 Horizontal seal
RLY-2 Vertical seal
RLY-3 Cutter
RLY-4 Nitrogen fill
RLY-5 Batch cutter
RLY-6 Batch coding
RLY-7 Auger
RLY-8 Unwinding
NO-C
5A, 230V AC
Relay Output
Clutch & Brake
Output 24 V DC
Page 1
96
92
92
96
96
Outline Dimension (mm) Panel Cutout
Dimension (mm)
52
3
Packaging FLC
RESET
P-
FLC 68
TERMINAL CONNECTION
Made in India www.multispanindia.com
100
250V AC
SUPPLY
24V DC
6VA Max.
+
CLUTCH
COM
BREAK
+
- -
C
18
19
21
22
2324
26
2728
29
303132 25 20 17
15
14
13
1211
10
98765
4321 16
C8
NO8
NO7
NO6
NO5
NO 4
NO 3
NO 2
NO 1
+12V
NPN
START
PROXI
GND
+12V
NPN
GND
PNP
EYE MARK
SENSOR
+12V
NPN
GND
UNWINDING
START
C
1
4
Relay status
To Relay configuration, RTC Setting, Pull time settings, &
Password setting
It will show date & time. To change/edit go in RTC Setting It will show the status of sensor inputs &
operation of process.
8 Output Relay ON/OFF status display
It is for toggle home page
3
2
4
1) When the proxy pulse comes from clutch proxy (start pulse) the clutch will ON till Max Pull Time or unless
getting the pulse of CMS, but CMS pulse will consider only after Max Minus Min Pulling Time is completed.
This page will display when, Tap to the toggle icon.
Brake mode selection: 1) Pull Time base or 2) Eye mark sensor base
2) After completion of Max Pull Time or getting the CMS pulse (As per selected brake mode),
the clutch Relay will Remain OFF and the Brake Relay will Remain ON.
3) After Brake, all Delay time will start, and completion of that Delay time, Relay will ON as per set ON time
R1
R1
1
1
Work Flow :
Explanation of data display section:
Page 2
1
2
3
4
(Home)
Time
Status display
Relay status
Toggle button
Tap to open Menupage
It will show date & time. To change/edit go in RTC Setting
It will show the status of inputs &
outputs
8 Output Relay ON/OFF status display
Tap to between stoggle home page
NO. Function/Icon Description
Start Start
R1
R1
It will show the status of sensor inputs &
operation of process.
R1
R1
It will change colour,
when its ON.
1) When the proxy pulse comes from clutch proxy (start pulse) the clutch will ON till Max Pull Time or unless
getting the pulse of CMS, but CMS pulse will consider only after Max Minus Min Pulling Time is completed.
1. When the start pulse occurs from the clutch proxy, the clutch will turn ON and remain ON
either until max pull time (in Time mode) or until CMS proxy occurs after the difference of
max and min pull time (in CMS mode).
OR
When the start pulse occurs from the clutch proxy, the clutch will turn ON and remain ON
until one of the following:
(i) Max pull time (in time mode)
(ii) CMS pulse is detected after max - min pulltime (in CMS mode)
2. As the pull time completes or the CMS pulse occurs, the brake will turn on.
3. After brake, respective relays will operate based on their delay and ON time
configurations.
1) When the start pulse occurs from the clutch Proxy, the clutch will turn ON and remain ON
until one of the following :
(i) Max pull time (in time mode)
(ii) CMS pulse is detected after max - min pull time (in CMS mode)
2) As the pull time completes or the CMS pulse occurs, the brake will turn on.
3) After brake, respective relays will operate based on their delay and ON time
configurations.
Explanation of Menu page:
Tap to go back to homepage.
Tap to select number of relays.
1) Relay setting
There is a 7 relay output selection available.
Tap icon for relay timing selection
Select Relay, for which the parameter you want to change.
Page 3
This page will display, when Horizontal Seal Relay select.
Tap to edit
relay timing
2) RTC setting
3) Pull time
Tap to edit date/time
Tap to edit pull time.
Page 4
Tap to change RTC.
Tap to edit pull timing.
4) Password setting
5) Manual Mode
To enable/Disable,you need to
enter current password.
Warning:
Only enter in this mode after all
relays operations are completed.
Tap on Particular relay, for Manual operation of that Relay. It will change color, when its ON.
User can use only one relay at a time.
Relay will turn ON based on respective
ON time.
Page 5
Tap to change Password settings.
Tap to Manual mode.
Power ON
Homepage 1
Tap to toggle home page
Tap NEXT for individual
Relay settings.
Tap Icon for Date & Time settings. Tap Icon for Manual Mode
Tap Icon for Password settings.
Tap Icon for Relay selection &
Relay delay time settings. .
Tap Icon for Pull time settings.
Select particular relay
for delay/ON time setting
If Enable, then password
can change by keypad.
Tap to turn ON any relay.
Tap for menu page
Homepage 2
MAN UAL
MODE
Switching operation of screens
Page 6
PULLING TIME
HORIZONTAL SEAL RLY1 VERTICAL SEAL RLY2
DLY Time = 1.00
MAX TIME = 10.00
MIN TIME = 3.00
DLY Time = 3.00
ON TIME = 4.00
DLY Time = 4.00
ON TIME = 4.00
START PULSE
RLY 1
DLY DLY
DLY DLY
BRAKE ON
RLY 2
Till RLY 7
.
.
.
0
0
0 0
0 0
5
5
5
5
10
8
8
8
9
10
10 11
10 11 12
15
15 16
15
15 16
20
20
20
20
25
25
25
25
30
30
30
30
35
35
35
35 (sec)
(sec)
(sec)
(sec)
BRAKE CLUTCH
ON
ON
CLUTCH ON
CMS PROXY
0
0 1
5
5
10
8
8 10
15
15
20
20
25
25
30
30
35
35
(sec)
(sec)
CLUTCH
DLY
CONTROL FUNCTION
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oils steam,
or other unwanted process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’ or
‘OFF’ function. However this mains switch or circuit breaker
must be installed at convenient place normally accessible to
the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
Page 7
Page 8
NOTE :-
Product improvement and upgrade is a constant procedure. So for more updated operating information and Support,
Please contact our Helping: +91-9978991474/9978991476/9978991482 or Email at ser[email protected] Ver: 2102
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

MULTISPAN PFLC-68 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI