MULTISPAN SQT-1244 Owner's manual

Type
Owner's manual
SQT-1244
AUXILIARY SUPPLY:
Sequential Timer : 12 Channel
Supply voltage
Power consumption
(VA RATING) Approx 5 VA @ 230V AC MAX
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
100 to 270V AC, 50-60Hz
Input (Start Pulse)
Range
TECHNICAL SPECIFICATION
Range:
MECHANICAL INSTALLATION
TERMINAL CONNECTION
Trigger
Enable
99.99 Sec
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
LED Indication
Rating
12 Relay
1) Relay Status
2) Time Unit
5A, 230V AC
Relay Output
DISPLAY AND KEYS:
DIMENSION:
Display
Size
Keys
Panel Cutout
Upper: 4 digit, 7 segment, 0.56”
Lower: 4 digit, 7 segment, 0.40”
96 (H) x 96 (W) x 54 (D) mm
SET, SHIFT, INC, ENT/RST
92 (H) x 92 (W) mm
96 54
92
92
3
96
Outline Dimension (mm) Panel Cutout
Dimension (mm)
Power ON
999.9 Sec
99.59 Min
99.59 Hrs
999.9 Hrs
Timer Mode
Timer Mode:
Delayed ON
Delayed OFF
Cycle Timer
Display Color:
Upper : RED
Lower: Green
SQT 1244
SET ENT
RST
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
Sec Min Hr
17
18
19
20
21 16
22
23
24
2526
27
282930
NO1
C1
C2
C3
C4
C5
C6
C7
14
13
1211
10
1 2 3 4 5 6 7 8 9 15
LN
~
50/60 Hz
5VA
100
270V AC
Made in India
NO2
NO3
NO4
NO5
NO6
NO7
www.multispanindia.com
RESET
START
NO12
C12
NO11
C11
NO10
C10
NO9
C9
NO8
C8
KEY OPERATION
To enter in parameter setting
mode
To reset the timer
PRESS KEYFUNCTION
OPERATOR MODE
PARAMETER SETTING MODE
Edited parameter value to be set,
And move to the next parameter
It will select the digit to modify,
When value is edited
It will change the Value of
selected digit
Set parameter to save & exit
RST
ENT
RST
ENT
Product : UNI.SEQUANTIAL TIMER
Model No.: SQT-1244
Input: Enable, Trigger, Power ON
Range : Universal Range
12R1C/O Output :
Start Pulse Selectable, Reset at BackControl Action :
100 to 270V AC,50/60Hz,Approx 5VASupply :
Accuracy : ± 1 % Of FSD
Calibrator Used : Time Totalizer
Calibrator Sr. No . : Time CAL-2
Q.A. Engineer
AHMEDABAD
**
Test Certificate
WARRANTY
Multispan warrants that the product supplied here
under this Test Certificate is guaranteed against
our design, our manufacturing and our workmanship
defects for a time period of 12 Months from
the date of product dispatch from our premises. Multispan
undertakes the responsibility to replace/repair the faulty
product at our company premises free of cost.
The manufacturing liability is limite d to the
value of goods supplied. Hereby, the manufacturer
will take no responsibilities for whatsoever any
consequential damages claimed by the customer
whatsoever. This warranty certificate is required to be
produced for obtaining any repair or replacement
service from the Manufacturer. The Manufacturer
r e s e r v e r i g h t to d e t e r m i n e t h e r e a s o n f o r
D e f e c t / D a m a g e , b e f o r e p r o v i d i n g s e r v i c e .
DESCRIPTION
No
Cycle 1
Delayed Off
Off Time 1
Cycle
Delay Time 1
Mode 1
No. Of Cycles
Individual
Power On
Enable
Yes
DISPLAY
SR.
1
9
5
13
3
11
7
15
18
20
22
24
Password
Time 1
Range
No. Of Channels
Common
Delayed On
On Time 1
Range 1
Mode
Input
Trigger
Memory
2
10
6
14
17
4
12
8
16
19
21
23
N O
P A S S
D L O N
D L O F
R N G E
m O d 1
R N 1
C Y L 1
T I m 1
D L Y 1
O N - 1
O F - 1
N O. C H
N O. C L
M O D E
C O M N
I N D U
P W O N
E N B L
Y E S
I N p T
T R 1
M E M O
C Y C L
Display Message & Their Meaning
PARAMETER SETTING
Menu-1
Time 1
&
&
&
&
T m - 1
S E T
Delay Time 1
D L y 1
On Time 1
On -1
Off Time 1
1 2 3 4
1 2 3 4
1 2 3 4
OF -1
1 2 3 4
Repeated
for
all Channels
Repeated
for
all Channels
Mode
= (?)
On delay
Off delay
IF Cycling Mode
is Selected
Press Key for save & exit
ENT
RST
SET
SET
Press key
SET
SET
SET
SET
M O D E
M O D 1
R N E
C Y L1
(IF Cycle Mode
is Selected)
9 9. 9 9 9 9. 9 9
9 9 9.99 9 9.9
9 9 9. 99 9 9. 9
9 9. 5 9 9 9. 5 9
9 9 9
9 9. 5 9 9 9. 5 9
D L O N D L O N
D L O F D L O F
C Y C L C Y C L
Mode
= (?)
IF Common mode IF Individual mode
&&
&
&
&
P A S S Pass word
SET + SHIFT KEY
1 0 4 4
Repeated
for
all Channels
Press Key
for save & exit
Sec Sec
Hr Hr
Hr Hr
Sec Sec
Min Min
Press Key for save & exit
ENT
RST
ENT
RST
Press + Key
SET
Press key
SET
SET
SET
SET
SET
SET
R n 1
Menu-2
PARAMETER SETTING
Note
* To make parameter setting easy, menu is devided in
three groups.
1) Menu 1: is used to set the parameters which are
needed to change Frequently, like delay time,
On time & OFF Time
2) Menu 2: is used to set the parameters like password,
mode, range & No. Of cycles.
3) Menu 3: is used to set the parameters Which Needed
to change in rare Case like No of channel,
No of cycle, individual & Common mode,
Type of input & memory retention.
Working
1) First enter in menu-3 (Press Key ) Then Power On.
2) Configure The instrument As per Your Application
3) Press + Key & Follow Menu-2 as per the Application.
SET
4) Press Key in Menu-1
5) At Any time press key to save and exit.
6) To Change Any parameter & Key.
7) To go to next parameter, Press Key.
8) If No key is Pressed, Menu will Automatically exit after
15 SEC. without saving.
ENT
RST
SET
SET
To Select No. Of Channels
(Maximum:12)
To Select No. Of Cycles.
IF 0 Selected instrument
will go in infinite loop
In ‘Common’ Selected
All channels Would have
same mode.
Type Of Input For Start Pulse
Can Be Selected
To Keep Memory Select
‘YES’
IF ‘Individual’
Selected
all channels can be
configured individualy
M O d e
1 2
9 9 9
M e m O
Y e s N O
I n p t
P w O n T r 1 E n b l
C O m n
I n d u
N O. C H
N O. C L
Press Key for save & exit
ENT
RST
&
&
SET
SET
SET
SET
SET
Press key+Power ON
Menu-3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4