HomComfort 3224OFP User manual

Category
Wood stove
Type
User manual

HomComfort 3224OFP is an outdoor fireplace designed to burn wood effectively and efficiently. It features a durable construction with a minimum chimney height of 60 inches and a flue pipe diameter of 10 inches. The unit is made of high-quality materials, including black or blued steel with a temperature resistance of 2100°F (650°C).

The HomComfort 3224OFP is designed to provide a safe and enjoyable outdoor experience. It is equipped with safety features such as a combustion chamber and a flue pipe to ensure proper ventilation. The appliance is also easy to use, with a simple ignition process and adjustable air control for precise temperature regulation.

HomComfort 3224OFP is an outdoor fireplace designed to burn wood effectively and efficiently. It features a durable construction with a minimum chimney height of 60 inches and a flue pipe diameter of 10 inches. The unit is made of high-quality materials, including black or blued steel with a temperature resistance of 2100°F (650°C).

The HomComfort 3224OFP is designed to provide a safe and enjoyable outdoor experience. It is equipped with safety features such as a combustion chamber and a flue pipe to ensure proper ventilation. The appliance is also easy to use, with a simple ignition process and adjustable air control for precise temperature regulation.

MODEL: 3224OFP
Wood Burning APPLIANCE
United States Stove Company
227 Industrial Park Road • South Pittsburg, TN 37380
www.usstove.com • (800) 750-2723
SAFETY NOTICE:
If this appliance is not properly installed, a house re
may result. For your safety, follow the installation
instructions. Never use make-shift compromises
during the installation of this appliance. Contact
local building or re ofcials about permits,
restrictions and installation requirements in your area.
CAUTION!
Please read this entire manual before you install
or use your new room appliance. Failure to follow
instructions may result in property damage, bodily
injury, or even death.
Improper Installation Could Void Your Warranty!
Contact your local building or re
ofcials about obtaining permits,
restrictions and installation inspection
requirements in your area.
Save these instructions.
U.S. Environmental Protection Agency
This unit is not a certied residential
wood heater.
This is not a UL listed Appliance
852978-2605G
*Unit is shown with optional brick kit
SAFETY NOTICE
If this appliance is not properly installed, a house re may result. To reduce the risk of re, follow the
installation instructions.
Consult your municipal building department or re ofcials about permits, restrictions and installations
requirements in your area.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter uid, or similar liquids to start or
“freshen up” a re in this appliance. Keep all such liquids well away from the appliance while it is in use.
In the event of a chimney re, keep the air control full closed to deprive the re of oxygen. Call the re
department.
INSTALLATION CLEARANCES
The clearances given are minimum dimensions by the NFPA. Installation of this appliance must comply with the
latest edition of NFPA 211 and / or your local building code rulings. Use whichever is largest.
Your appliance must be installed in residential applications in accordance with the clearances given below. For
safety reasons, please adhere to the installation clearances and restrictions. Check with your municipal building
department or re ofcials for methods to reduce clearances.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of an appliance due to improper venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
This unit is only intended to be used In conjunction with masonry block and/or pavers to make an outdoor
replace
Appliance Installation
Note: Register your product on line at www.usstove.com. See “Limited Warranty” section for specic warranty
information for your new purchase. Save your receipt with your records for any claims.
Congratulations!
You’ve purchased an appliance from North America’s oldest manufacturer of wood burning products.
By cooking with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least
one tree each year. Future generations will thank you.
The instructions pertaining to the installation of your wood burring appliance comply with NFPA 211.
CAUTIONS:
Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns
Do not use chemicals or uids to ignite the re
Do not leave the appliance unattended
Do not burn garbage, ammable uid such as gasoline, naphtha or motor oil
Combustible: Wood
Flue Pipe Diameter: 10”
Flue Pipe Type: (Standard Single Wall or Double Wall): Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height: 60”
Dimensions
28.00
26.00
25.00
2
6.00
28.
00
30.86
36”36”
36”
36”
Clearance To Combustibles
Your appliance was designed to
burn wood only; no other materials
should be burned. Waste and other
ammable materials should not be
burned in your appliance. Any type of
wood may be used in your appliance,
but specic varieties have better
energy yields than others. Please
consult the following table in order to
make the best possible choice.
It is EXTREMELY IMPORTANT that you
use DRY WOOD only in your wood
appliance. The wood should have
dried for 9 to 15 months, such that the
humidity content (in weight) is reduced
below 20% of the weight of the log. It
is very important to keep in mind that
even if the wood has been cut for one, two, or even more years, it is not necessarily dry if it has been stored in
poor conditions. Under extreme conditions it may rot, instead of drying. This point cannot be over stressed; the
vast majority of the problems related to the operation of a wood appliance is caused by the fact that the wood
used was too damp or has dried in poor conditions. These problems can be:
- Ignition problems
- Creosote build-up causing chimney res
- Low energy yield
- Blackened windows
- Incomplete log combustion
Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split. The wood should not be
stored directly on the ground. Air should circulate through the cord. A 24” to 48” air space should be left between
each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be
protected from the elements but not the sides.
FLOOR PROTECTION
This appliance must only be installed on the required brick kit.
CHIMNEY CONNECTOR (STOVE PIPE)
Your chimney connector and chimney must have the same
diameter as the appliance outlet (10”). If this is not the case, we
recommend you contact your dealer in order to insure there will be
no problem with the draft.
The stove pipe must be made of aluminized or cold roll steel with a
minimum thickness of 0.021” or 0.53 mm. It is strictly forbidden to use
galvanized steel.
Your smoke pipe should be assembled in such a way that the male
section (crimped end) of the pipe faces down. Attach each of the
sections to one another with three equidistant metal screws. Seal
with furnace cement.
The pipe must be short and straight.
To insure a good draft, the total length of the coupling pipe should never exceed 8’ to 10’ (2.4m to 3.04 m).
Installation of a “barometric draft stabilizer” (replace register) on a smoke exhaust system is prohibited.
Furthermore, installation of a draft damper is not recommended. Indeed, with a controlled combustion wood
appliance, the draft is regulated upon intake of the combustion air in the appliance and not at the exhaust.
Ventilation
Appliance Utilization
TYPE WEIGHT
(LBS. CU. FT.,
DRY)
PER CORD EFFICIENCY
RANKING
SPLITS MILLIONS
BTU’s/CORD
Hickory 63 4500 1.0 Well 31.5
White Oak 48 4100 .9 Fair 28.6
Red Oak 46 3900 .8 Fair 27.4
Beech 45 3800 .7 Hard 26.8
Sugar Maple 44 3700 .6 Fair 26.2
Black Oak 43 3700 .6 Fair 25.6
Ash 42 3600 .5 Well 25.0
Yellow Birch 40 3400 .4 Hard 23.8
Red Maple 38 3200 .3 Fair 22.6
Paper Birch 37 3100 .3 Easy 22.1
Elm/Sycamore 34 2900 .2 Very Difcult 20.1
Red Spruce 29 1800 .1 Easy 16.1
TESTING YOUR WOOD
When the appliance is thoroughly warmed, place one piece of split wood (about ve inches in diameter)
perpendicular to the door on the bed of red embers.
Keep the air control full open by sliding it right and close the door. If ignition of the piece is accomplished within
90 seconds from the time if was placed in the appliance, your wood is correctly dried. If ignition takes longer,
your wood is damp.
If your wood hisses and water or vapor escapes at the ends of the piece, your wood is soaked or freshly cut. Do
not use this wood in your appliance. Large amounts of creosote could be deposited in your chimney, creating
potential conditions for a chimney re.
THE FIRST FIRES
The fresh paint on your appliance needs to be cured to preserve its quality. Once the fuel charge is properly
ignited, only burn small res in your appliance for the rst four hours of operation. Never open the air control more
than necessary to achieve a medium burn rate.
Make sure that there’s enough air circulation while curing the appliance. The odors may be smelled during the
rst 3 or 4 res. During curing people and animals with lung problems should take caution.
IGNITION
Place several crumpled sheets of paper in the center of the combustion chamber. Place 8 to 10 pieces of small
dry kindling wood over the paper in the form of a tent. No chemical product should be used to light the re.
Before igniting the paper and kindling wood, it is recommended that you warm up the chimney. Twist together
a few sheets of newspaper into a torch. Light up this paper torch and hold it as close as possible to the back of
the combustion chamber to warm up the chimney. Once the updraft movement is initiated, you are ready to
ignite the appliance by lighting the paper and kindling wood inside the combustion chamber.
RELOADING
Once you have obtained a good bed of embers, you should reload the unit. Bring the red embers to the front
of the appliance and reload the unit. For optimal operation of your wood appliance, we recommend you to
operate it with a wood load approximately equivalent to the height of re bricks. Creosote - Formation and
Need for Removal - When wood is burned slowly, it produces tar and other organic vapors, which combine with
expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney ue of a slow-
burning re. As a result, creosote residue accumulates on the ue lining. When ignited, this creosote makes an
extremely hot re. The chimney connector and chimney should be inspected at least once every two months
during the season to determine if a creosote build-up has occurred. If creosote has accumulated (3mm or more),
it should be removed to reduce the risk of a chimney re.
TO PREVENT CREOSOTE BUILD UP
Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore, less creosote
deposit.
Always check for creosote deposit once every two months and have your chimney cleaned at least once a
year.
If a chimney or creosote re occurs, close all dampers immediately. Wait for the re to go out and the appliance
to cool. Then, inspect the chimney for damage. If no damage results, perform a chimney cleaning to ensure
there is no more creosote deposits remaining in the chimney.
ASH DISPOSAL
Ashes should be removed from the appliance every few days or when ashes get to 2 to 3 inches deep. Always
empty the appliance when it is cold, such as in the morning. Ashes should be placed in a metal container with
a tight tting lid. The closed container of ashes should be placed on a non combustible oor or on the ground,
well away from all combustible materials, pending nal disposal. If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled. Other waste shall not be placed in this container.
Warnings: Never overre your appliance. If any part of the appliance starts to glow red, over ring is happening.
Readjust the air intake control at a lower setting. The installation of a log cradle or grates is not recommended
in your wood appliance. Build re directly on rebrick. Never put wood above the rebrick lining of the rebox.
CAUTIONS:
Ashes could contain hot embers even after two days without operating the appliance.
The ash pan can become very hot. Wear gloves to prevent injury.
FUEL STORAGE
Wood can be dried sufciently for burning within a few weeks if protected form rain in a low humidity area. It
is far better to cut wood and allow it to dry for a year. In all cases, the wood should be stacked so that both
ends of the sticks are exposed to the air and protected from rain. The drier the wood, the more usable heat
produced by the re and less likely rapid accumulation of soot and creosote within the chimney is to occur. See
the section of this manual concerning chimney maintenance for information concerning the hazards of soot a
creosote accumulation. Small quantities of wood required for re tending must be kept at least 30 inches from
the replace.
CHIMNEY MAINTENANCE
Creosote, Formation and Need for Removal: When wood is burned slowly, it produces tar and other organic
vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively
cool chimney ue of a slow-burning re. As a result, creosote residue accumulates on the ue lining. When
ignited, this creosote makes an extremely hot re.
The chimney should be inspected at least twice a year during the heating season to determine if a creosote
buildup has occurred.
If creosote has accumulated it should be removed to reduce the risk of a chimney re.
The chimney cap can be removed for inspection, maintenance and cleaning by removing three screws from
the support legs and lifting upward.
When the replace is rst in use, inspect the chimney frequently and clean the chimney any time an accumulation
is observed on the ue walls. The frequency of these inspections can be increased or reduced appropriately
after a pattern of accumulation has been established. Please note, however, that changes in the outside
environmental conditions such as temperature and humidity or changes in the operation of the replace can
lead to rapid buildup of soot and/or creosote.
To clean the chimney, obtain the services of a qualied and reputable chimney sweep, or remove the
accumulation with brushes on wooden or berglass poles. Do not use metal pipes, chains, wires, etc., to clean
the chimney because such items can scratch the surface of the stainless steel ue which can shorten the life of
the ue and provide a rough surface for soot particles to attach to.
Be sure to cover nearby furnishing and arrange some method of catching soot and creosote particles that may
fall during the chimney cleaning process.
In addition to checking and cleaning the chimney on a regular basis, be sure to inspect the chimney before
starting a re at the beginning of each heating season. Make sure the chimney is clear from any accumulation
of soot, creosote or any other debris, and that all joints are intact.
United States Stove Co. does not recommend chemical cleaners because some may contain elements that
corrode the metal parts of the chimney or replace.
FIREPLACE MAINTENANCE
At the end of each heating season or when the replace will not be in use for an extended time, the ashes should
be removed and the hearth area should be swept as clean as is practical. The slow absorption of moisture into
the ashes over a long period of time could cause a condition which would be corrosive to the metal replace
parts.
As you use the replace, expansion and contraction will cause minor cracking of the hearth, back, and side
refractory materials. This is normal and unavoidable. If the cracks become large enough or parts dislodge and
metal behind the refractory is exposed, the refractory panels should be replaced with new panels that can be
obtained from you replace dealer.
Maintenance And Safety
CHECKLIST OF DO’S AND DONT’S
DO’S
1. Do check with local building ofcials to be sure the installation of the replace complies with all building
codes and requirements and obtain required building permits. Do plan your installation with safety as you
primary consideration.
2. Do use only the prescribed material and parts for the installation of the replace.
3. Do install the proper chimney cap or chimney housing on the chimney to prevent rain and debris from
entering the chimney.
4. Do keep all ammable liquids, gases and pressurized containers away form the replace.
5. Do check the replace for proper adjustment and operation before leaving it unattended for long periods
of time.
6. Do inspect and clean the replace chimney regularly.
7. Do start a re only with paper, kindling or solid composition re starters specically designed for starting a re.
The use of liquid re starter can cause an explosion within the replace.
8. Do place all ashes in a metal container with a tight tting lid and place them on a noncombustible surface
well away from other combustible materials until they have completely cooled.
9. Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustible
materials from the replace.
10. Do build res of moderate intensity in the replace for the rst three res to allow materials to adjust and cure
before being subjected to the intense heat of a large re.
DONT’S
1. Don’t allow other installations or operation considerations to take priority over safety considerations.
2. Don’t attempt to use the replace until the installation is complete.
3. Don’t use damaged parts or accessories with this replace.
4. Don’t install the replace on a poorly constructed base or fail to fasten down or attach the replace to
prevent it from shifting out of position.
5. Don’t create or allow a crack to develop between the metal face of the replace and noncombustible trim.
6. Don’t install the replace where ammable or explosive liquids or vapors are likely to be present.
7. Don’t neglect all the considerations mentioned in this manual concerning clearances to combustibles,
spacing from obstructions and proper chimney height when selecting the location and installing the chimney.
8. Don’t allow insulating materials to contact the chimney.
9. Don’t dry clothing or other articles near the replace.
10. Don’t store or place ammable liquids, gases or pressurized containers near the replace.
11. Don’t neglect to instruct all responsible persons in the proper and safe operation of the replace.
12. Don’t fail to instruct all persons, especially children and elderly persons, concerning the hazards of improper
operation and unauthorized tampering with the replace.
13. Don’t use this replace to burn paper, cardboard, or other debris.
14. Don’t neglect to inspect and clean the chimney regularly.
15. Don’t use gasoline, kerosene, engine oil,or charcoal lighter uid.
16. Don’t store fuel supply closer to the replace than the minimum spacing required for combustible materials.
17. Don’t subject the replace to the intense heat of a large re the rst three times the replace is used, but
build moderate res to allow the materials to cure and adjust.
18. Don’t clean the chimney with metallic devices or chemical cleaners.
19. Don’t use the replace or chimney for venting wood or coal burning heaters or inserts unless approved in
writing by United States Stove Co..
20. Don’t put combustibles within 28 inches of the replace opening.
Warning: If not installed, operated and maintained in accordance with the manufacturers instructions, this
product could expose you to substances in fuel or from fuel combustion which can cause death or serious
illness and which are known to the state of California to cause cancer, birth defects or other reproductive
harm. Also, operation, installation and servicing of this product could expose you to airborne particles of glass
wool bers known to the state of California to cause cancer through inhalation.
SEASONAL START UP
Prior to starting the rst re of the heating season, check the outside area around the exhaust systems for
obstructions. Clean and remove any y ash from the exhaust venting system. Clean any screens on the exhaust
system and on the outside air intake pipe. This is also a good time to give the entire appliance a good cleaning
throughout.
SEASONAL SHUTDOWN
The exhaust system should be thoroughly cleaned. REMOVE ANY ASH OR UNBURNED WOOD.
MAINTENANCE SCHEDULE
Use the following as a guide under average use conditions.
Gaskets around door and door glass should be inspected and repaired or replaced when necessary.
Daily Weekly Monthly or as needed
Ashes Check Empty
Vent System Cleaned
When your appliance acts out of the ordinary, the rst reaction is to call for help. This guide may save time and
money by enabling you to solve simple problems yourself. Problems encountered are often the result of only ve
factors.
1. Poor fuel;
2. Poor operation or maintenance;
3. Poor installation;
4. Component failure;
5. Factory defect.
You can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5.
Refer to the repair parts diagrams to help locate indicated parts.
Never try to repair or replace any part of the appliance unless instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Trouble Shooting Guide
Optional Brick Kit
4
5
3
1
2
Key Part No Description Qty
1 28078 Rear Brick Retainer 1
228072 Side Brick Retainer 2
3 89066A Firebrick (4-1/2 x 9) Pumice 32
4 892779A Quarter Firebrick (2-1/4 x 9) Pumice 1
5 891414A Half Firebrick 1-1/4 x 2-1/4 x 9 Pumice 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

HomComfort 3224OFP User manual

Category
Wood stove
Type
User manual

HomComfort 3224OFP is an outdoor fireplace designed to burn wood effectively and efficiently. It features a durable construction with a minimum chimney height of 60 inches and a flue pipe diameter of 10 inches. The unit is made of high-quality materials, including black or blued steel with a temperature resistance of 2100°F (650°C).

The HomComfort 3224OFP is designed to provide a safe and enjoyable outdoor experience. It is equipped with safety features such as a combustion chamber and a flue pipe to ensure proper ventilation. The appliance is also easy to use, with a simple ignition process and adjustable air control for precise temperature regulation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI