  • Hello! I am an AI chatbot trained to assist you with the ZALMAN ZM500-HP PLUS User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Users Manual
ZM500-HP PLUS
ZM600-HP PLUS
Ver. 1.0
www.ZALMAN.com
To ensure safe and easy installation,
please read the following precautions.
Resonant Switching
Power Supply
11
2. Components
1. Warnings and Safety Precautions
Opening the cover of the product while the power cord is plugged into an outlet
may cause electrocution or critical damage to the product.
Handling the power cord with wet hands may cause electrocution.
Inserting ngers or metallic objects into the cooling fan may cause injury or
electrocution.
Operating the product in an extremely cold or hot environment can degrade
product performance
and lifespan.
Exposure to liquids may cause malfunction.
Operation in a humid or non-ventilated environment may reduce product lifespan.
Plugging the main power connector P1 into the motherboard while the product is
connected to the AC power source may cause damage to the motherboard.
Make sure that the connectors are connected to their designated locations, and
that the connectors are not
oriented in the wrong direction when connecting the
DC output connectors.
Please use gloves to prevent injuries during installation.
Product designs and specications may be revised without prior notication to
improve quality and performance.
Neglecting the following may cause serious injury or death.
Neglecting the following may cause minor injuries, degrade product
conditions or cause malfun
ction.
Caution
Warning
Disclaimer) Zalman Tech Co., Ltd. is not responsible for any damages due
to external causes, including but not limited to, improper use,
problems with electrical power, accident, neglect, alteration,
repair, improper installation, or improper testing.
Power Supply
AC Power Cord
Four (4) Fixing Bolts
Users Manual
22
3. Specications
1) ZM500-HP PLUS Electrical & Physical Specications
2) ZM500-HP PLUS Output Power Cable Specications
AC Input Range
Voltage 100 ~ 240VAC ZM500-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined
Power
AC Input Current
115VAC 8A I
min
I
max
I
peak
230VAC 4A +3.3V 0.5A 24A
130W
500W
PFC Type Active PFC +5V 0.1A 24A
Power Factor MAX 99% +12V1 0.1A 18A 20A
432W
Inrush Current Limit
(@ Cold start at 25)
115VAC 55A +12V2 0.1A 18A 20A
230VAC 110A -12V 0.0A 0.5A
21W
Efciency MAX 88% @ 230VAC, Typical load +5VSB 0.1A 3A 3.5A
DC Output Voltag
e
Regulation
V
out
Stable Range
At
Full
Load
Ambient Temperature
+3.3VDC ±5% +3.14 ~ +3.47V Operation 10 ~ 40
+5VDC ±5% +4.75 ~ +5.25V Stored -20 ~ 80
+12V1DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V2DC ±5% +11.4 ~ +12.6V Operation 5 ~ 95%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions 165(L) × 150(W) × 86(H)
DC Output Ripple
& Noise
V
out
Standard Range
At
Full
Load
Weight 2.79(Full Package)
+3.3VDC
50mV Protection Features
+5VDC 50mV Over-Voltage Protection (OVP)
+12V1DC 120mV Over-Current Protection(OCP)
+12V2DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over -Temperature Protection(OTP)
33
4) ZM600-HP PLUS Output Power Cable Specications
AC Input Range
Voltage 100 ~ 240VAC ZM600-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined
Power
AC Input Current
115VAC 10A I
min
I
max
I
peak
230VAC 6A +3.3V 0.5A 24A
140W
600W
PFC Type Active PFC +5V 0.1A 24A
Power Factor MAX 99% +12V1 0.1A 18A 20A
576W
Inrush Current Limit
(@ Cold start at 25)
115VAC 80A +12V2 0.1A 18A 20A
230VAC 150A +12V3 0.1A 18A 20A
Efciency MAX 88% @ 230VAC, Typical load +12V4 0.1A 18A 20A
DC Output Voltag
e
Regulation
V
out
Stable Range
At
Full
Load
-12V 0.0A 0.5A
21W
+3.3VDC ±5% +3.14 ~ +3.47V +5VSB 0.1A 3A 3.5A
+5VDC ±5% +4.75 ~ +5.25V Ambient Temperature
+12V1DC ±5% +11.4 ~ +12.6V Operation 10 ~ 40
+12V2DC ±5% +11.4 ~ +12.6V Stored -20 ~ 80
+12V3DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V4DC ±5% +11.4 ~ +12.6V Operation 5 ~ 95%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions
DC Output Ripple
& Noise
V
out
Standard Range
At
Full
Load
165(L) × 150(W) × 86(H)
+3.3VDC 50mV Weight
+5VDC 50mV 2.8(Full Package)
+12V1DC 120mV Protection Features
+12V2DC 120mV Over-Voltage Protection(OVC)
+12V3DC 120mV Over-Current Protection(OCP)
+12V4DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over -Temperature Protection(OTP)
3) ZM600-HP PLUS Electrical & Physical Specications
44
4. Certications
/