Electrical connection:
The induction hob is supplied
including a connecting cable without
plug and, according to wiring diagram
A1, has a standard setting for 2
x 1 phase (230V). The induction
hob uses a so-called 5-pole Perilix
plug (not included). In the meter
cupboard, the groups must each be
protected with a 16 Ampere fuse at
least.
The induction hob can also be
connected according to wiring
diagram A2, this may only be
done by a recognised installer.
induction hob
IK010
connection cable
connection cable
connection block
connection block
A1
A2
CAUTION! When the induction hob
is connected according to wiring
diagram A2, a recognised
installer must always check that
the technical system in the meter
cupboard, the connection in the
induction hob and the connecting
cable still comply with the applicable
requirements and correspond with
the data in the wiring diagrams.
PE
2 x 230V 2L+2N~16A
220-240V ~16A
3x 1,5mm
2
220V~
3x 1,5mm
2
230V~
3x 1,5mm
2
240V~
Safety during use is only guaranteed when the assembly is technically correct and
in accordance with this installation instruction. The installer is liable for damage
caused by an incorrect assembly.
The electrical connection may be carried out only by a qualified electrician. This
person is familiar with national and regional safety instructions that the connection
should meet.
The induction hob falls under protection class I and should only be used
in combination with an earthed connection. The manufacturer shall not be liable
for unsuitable operation and possible damage caused by unsuitable electrical
systems.
The induction hob must be connected to a fixed installation in which means
for deactivation are integrated, in accordance with the instructions for
the installation.
Induction hobs may only be installed above a drawer, an oven with forced
ventilation or a dishwasher, and always with a minimum distance for ventilation.
Under the induction hob, no refrigerators, ovens without ventilation or
washing machines should be installed.
Make sure the power cable does not get jammed during installation or does not run
along sharp edges. If an oven is mounted below it, allow the cable to run via the rear
corners of the oven to the connection cabinet. It must be placed in such a way that
there is no contact with hot parts of the induction hob or the oven
The connection point, wall socket and/or plug must always be accessible.
The worktop in which the induction hob is mounted should be flat, horizontal and
stable. Observe the instructions from the manufacturer of the worktop.
In case of incorrect installation, connection or assembly, the warranty shall become
invalid.
Attention: each change in the appliance, including mounting and replacing
the power cable, must be performed by a recognised installer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Inventum IKI6035 Owner's manual

Category
Hobs
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI