Hitachi RAC-EH13CKT User manual

Category
Split-system air conditioners
Type
User manual

This manual is also suitable for

– 2 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “
!
Warning” and “
!
Caution”. The “Warning” section contains matters which, if not
observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious
consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit.
Water leakage, fault, short circuit or re may occur if you reconstruct the unit by yourself.
Please ask your sales agent or quali ed technician for the installation of your unit. Water leakage, short circuit
or re may occur if you install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper
installation of earth line may cause electric shock.
Be sure to use the speci ed piping set for R32. Otherwise, this may result in broken copper pipes or faults.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the
danger of electric shock exists.
Do not install the unit near a location where there is ammable gas. The outdoor unit may catch re if
ammable gas leaks around it.
Please ensure smooth ow of water when installing the drain hose.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit
breaker. Contact your agent. Fault, short circuit or re may occur if you continue to operate the unit under
abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and re.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or re may occur if you remove
and reinstall the unit yourself improperly.
If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/parts centers.
If the air conditioner is not cool, one possible cause could be due to refrigerant leakage, so consult your dealer.
The refrigerant gas used in the air conditioner is harmless. But if refrigerant gas leaks into the room, harmful products
are generated when in contact with re from appliances such as a stove heater.
When there is refrigerant gas accumulation in the room, immediately stop the air conditioner. Open the windows for
ventilation and contact your agent.
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the gure indicates prohibition.
W
A
R
N
I
N
G
W
A
R
N
I
N
G
!
!
!
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air ow for your health.
W
A
R
N
I
N
G
!
Do not insert a nger, a rod or other objects into the air outlet or inlet. As the fan
is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop
the operation and turn the breaker OFF.
Do not use any conductor as fuse wire, this could cause fatal accident.
This symbol shows that this equipment uses
a ammable refrigerant.
If the refrigerant is leaked, together with an
external ignition source, there is a possibility
of ignition.
W
A
R
N
I
N
G
C
A
U
T
I
O
N
C
A
U
T
I
O
N
C
A
U
T
I
O
N
EXPLANATION OF SYMBOLS DISPLAYED ON UNIT
This symbol shows that there is information
included in the Operation Manual and/or
Installation Manual
This symbol shows that the Operation
Instructions should be read carefully.
This symbol shows that a service personnel
should be handling this equipment with
reference to the Installation Manual.
(EN1) RAS/RAC-EH10/13CKT.indd 2(EN1) RAS/RAC-EH10/13CKT.indd 2 2018-12-11 4:45 PM2018-12-11 4:45 PM
– 4 –
INDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
Pre- lter
To prevent dust from coming into the indoor unit.
(Refer page 18)
Front panel
Indoor unit indicators
Light indicator showing the operating condition.
(Refer page 5)
Horizontal de ector
Vertical de ector
(Air Outlet)
(Refer page 14)
Remote controller
Send out operation signal to the indoor unit. So as
to operate the whole unit.
(Refer page 6)
OUTDOOR UNIT
Drain pipe
Condensed water drain to outside.
Connecting cord and insulation pipe for piping
Air inlet (Back, Left side)
Air outlet
WIDTH (mm)
780
750
MODEL
RAS-EH10CKT, RAS-EH13CKT
RAC-EH10CKT, RAC-EH13CKT
HEIGHT (mm)
280
548
DEPTH (mm)
230
288
MODEL NAME AND DIMENSIONS
(EN1) RAS/RAC-EH10/13CKT.indd 4(EN1) RAS/RAC-EH10/13CKT.indd 4 2018-12-11 4:45 PM2018-12-11 4:45 PM
– 6 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. Signal range to reach indoor unit is about 7 meters. If
inverter lamp is used, the range of control may be shorter.
This unit can be xed on a wall using the xture provided. Before xing it, make sure the indoor unit
can be controlled from the remote controller.
Transmission sign
The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, timer status, function
and intensity of circulation selected.
AIR SLEEP TIMER button
Use this button to set the air sleep timer mode.
TEMPERATURE button
Use this button to raise or lower the temperature setting. (Keep pressed,
and the value will change more quickly.)
START/STOP button
Press this button to start or to stop operation.
FAN SPEED selector button
This determines the fan speed. Each time you press this button, the
intensity of circulation will change from
(AUTO)
(HI)
(MED)
(LOW).
AUTO SWING button
Controls the angle of the horizontal air de ector.
ONE TOUCH POWERFUL buttonA
Use this button to deliver faster and more comfortable air-conditioning
or start operation.T
RESET button
MODE selector button
Use this button to select MODE. Each time you press this button the
MODE selection will change from
(COOLING)
(SILENT)
(DEHUMIDIFY)
(FAN).
However, during OFF mode SILENT will be skipped.
OFF-TIMER button
Select to turn OFF time.
ON-TIMER button
Select to turn ON time.
Precautions for Use
Do not put the remote controller in the following places.
In direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the
oor, and protect it from water.
Once the outdoor unit stops, it will not restart for about 3
minutes (unless you turn the power switch off and on or unplug
the power cord and plug it in again).
This is to protect the device and does not indicate a failure.
(EN2) RAS/RAC-EH10/13CKT.indd 6(EN2) RAS/RAC-EH10/13CKT.indd 6 2018-12-11 4:57 PM2018-12-11 4:57 PM
– 8 –
SILENT OPERATION
During Cooling mode, press the selector button so that
the display indicates (SILENT) along with the (COOL)
symbol. Silent operation starts with a beep.
1
CANCELLATION of SILENT Operation
Cancel Condition
Operation mode after cancel
Key press
Key press
Key press
Key press
Stop operation
Selected mode operation
(COOLING) (SILENT)
(FAN) (DEHUMIDIFY)
COOLING operation in previous setting
POWERFUL operation
NOTE:
Under SILENT mode operation and quiet environment, phenomena like owing noise of refrigerant in the
refrigerating cycle may occur, but this is normal for the operation.
(EN2) RAS/RAC-EH10/13CKT.indd 8(EN2) RAS/RAC-EH10/13CKT.indd 8 2018-12-11 4:57 PM2018-12-11 4:57 PM
– 10 –
FAN OPERATION
Press the selector button so that the display indicates
(FAN).
As the settings are stored in memory in the remote controller, you
only have to select
(FAN) then press the
button next time.
Press the button. Fan operation starts with a beep.
Press the button again to stop the operation.
START
1
2
Set the desired FAN SPEED with the button.
(the display indicates the selectable setting).
(HI) : High fan speed.
(MED) : Medium fan speed.
(LOW) : Low fan speed.
In Fan operation mode the device is function as an air circulator.
FAN Function
During FAN operation, compressor does not run and there is no cooling operation with only indoor fan running.
(EN2) RAS/RAC-EH10/13CKT.indd 10(EN2) RAS/RAC-EH10/13CKT.indd 10 2018-12-11 4:57 PM2018-12-11 4:57 PM
– 12 –
HOW TO SET THE AIR SLEEP TIMER
Press the button, and the display changes as shown below.
Mode
Air Sleep Timer
Indication
Air Sleep Timer: The device will continue working for the
designated number of hours and then turn off.
Point the signal window of the remote controller toward the indoor
unit, and press the AIR SLEEP TIMER button.
The timer information will be displayed on the remote controller.
The TIMER lamp lights with a beep from the indoor unit.
Cooling
“ ” ,
Silent
and
Dehumidifying
Explanation of the air sleep timer
The device will control the FAN SPEED and room temperature automatically so as to be quiet
and good for people’s health.
You can set the sleep timer to turn off after 1,2,3
--
9 or 10 hours. The FAN SPEED and
room temperature will be controlled as shown below.
Function Operation
The room temperature will be
controlled 2°C above the setting
temperature and the FAN SPEED
will be set to LOWEST 1 hour
after the setting of the air sleep
timer.
Air Sleep
Timer
(EN2) RAS/RAC-EH10/13CKT.indd 12(EN2) RAS/RAC-EH10/13CKT.indd 12 2018-12-11 4:57 PM2018-12-11 4:57 PM
– 14 –
AIR FLOW LOUVERS ADJUSTMENTS
1
2
Adjustment of the conditioned air to the left and right.
Hold the second vertical air de ector of each set of vertical
air de ectors from right as shown in the gure and adjust the
conditioned air to the left or right.
If the “ (AUTO SWING)” button is pressed
once, the horizontal air de ector swings up and down.
If the button is pressed again, the de ector stops in its
current position. Several seconds (about 6 seconds) may
be required before the de ector starts to move.
Use the horizontal air de ector within the adjusting range
shown on the right.
When the operation is stopped, the horizontal air de ector
moves and stops at the position where the air outlet
closes.
!
CAUTION
In “Cooling” operation, do not keep the horizontal air
de ector swinging for a long time. Some dew may form
on the horizontal air de ector and dew may drop.
Adjustment of the conditioned air in the upward and downward
directions.
The horizontal air de ector is automatically set to the proper
angle suitable for each operation. The de ector can be swung
up and down continuously and also set to the desired angle
using the “
(AUTO SWING)” button.
A
Do not insert a nger, a rod or other objects into the air outlet or inlet as the fan is rotating at a high speed,
it will cause injury. Before any cleaning or adjusting the de ectors, be sure to switch OFF the operation.
!
WARNING
(EN2) RAS/RAC-EH10/13CKT.indd 14(EN2) RAS/RAC-EH10/13CKT.indd 14 2018-12-11 4:57 PM2018-12-11 4:57 PM
– 16 –
Suitable Room Temperature Install curtain or blinds
Ventilation Effective Usage Of Timer
Do Not Forget To Clean The Pre-Filter
Please Adjust Suitable Temperature
For Baby And Children
Warning
Freezing temperature
is bad for health and a
waste of electric power.
!
It is possible
to reduce heat
entering the
room through
windows.
At night, please use the “OFF or ON timer
or SLEEP timer operation mode”, together
with your wake up time in the morning. This
will enable you to enjoy a comfortable room
temperature. Please use the timer effectively.
Dusty air lter will reduce the air volume and
the cooling ef ciency. To prevent from wasting
electric energy, please clean the lter every
2 weeks.
Please pay attention to the room temperature
and air ow direction when operating the unit
for baby, children and old folks who have
dif culty in movement.
Caution
Do not close the room for a long period of
time. Occasionally open the door and windows
to allow the
entrance of
fresh air.
!
THE IDEAL WAYS OF OPERATION
(EN3) RAS/RAC-EH10/13CKT.indd 16(EN3) RAS/RAC-EH10/13CKT.indd 16 2018-12-11 4:59 PM2018-12-11 4:59 PM
– 18 –
1. PRE-FILTER
Clean the Pre- lter, as it removes dust inside the room. In case the Pre- lter is full of dust, the air
ow will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to
clean the Pre- lter following the procedure below.
1
Open the front panel and remove the Pre- lter
Gently lift and remove the air purifying lters
from the air purifying lter frame.
2
Vacuum dust from the Pre- lter and air purifying
lter using vacuum cleaner. If there is too much
dust, rinse under running tap water and gently
brush it with soft bristle brush. Allow lters to
dry in shade.
3
Re-insert the air purifying lter to the lter
frame. Set the Pre- lter with “FRONT” mark
facing front, and slot them into the original
state.
After attaching the Pre- lters, push the front
panel at three arrow portions as shown in
gure and close it.
!
CAUTION
Do not wash with hot water at more than 40°C. The Pre- lters may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly
to the sun. The Pre- lters may shrink.
Do not use detergent on the Pre- lter as some detergent may deteriorate the Pre- lter electrostatic
performance.
MAINTENANCE
Before cleaning, stop operation and switch off the power supply.
CAUTION
!
(EN3) RAS/RAC-EH10/13CKT.indd 18(EN3) RAS/RAC-EH10/13CKT.indd 18 2018-12-11 4:59 PM2018-12-11 4:59 PM
– 20 –
Cleaning and maintenance must be carried out only by quali ed service personnel. Before cleaning,
stop operation and switch off the power supply.
!
CAUTION
1
2
3
REGULAR INSPECTION
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONNEL EITHER
EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.
Is the earth line disconnected or broken?
Is the mounting frame seriously affected by rust and is the
outdoor unit tilted or unstable?
Is the plug of power line rmly plugged into the socket?
(Please ensure no loose contact between them).
CAUTION
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth
line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit
breaker, the danger of electric shock exists.
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code:
Green-and-yellow : Earth
Blue : Neutral
Brown : Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter
N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
NOTE
If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized
service/parts centers.
!
(EN3) RAS/RAC-EH10/13CKT.indd 20(EN3) RAS/RAC-EH10/13CKT.indd 20 2018-12-11 4:59 PM2018-12-11 4:59 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Hitachi RAC-EH13CKT User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI