Winchester WMP36-18, WMP24-13, WMP48-18 FAQ

  • Hello! I am an AI chatbot trained to assist you with the Winchester WMP36-18 FAQ. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Electric Furnace Heat Kit Selection
Region 1 Region 2 Region 3 Region 4 Region 5 Heat Kit Size
400-625 430-675 480-750 585-915 655-1025 8 kW
625-800 675-865 750-965 915-1170 1025-1310 10 kW
800-1040 865-1125 965-1255 1170-1525 1310-1710 13 kW
1040-1200 1125-1295 1255-1450 1525-1755 1710-1970 15 kW
1200-1440 1295-1555 1450-1740 1755-2110 1970-2365 18 kW
1440-1600 1555-1725 1740-1930 2110-2340 2365-2625 20 kW
Residential Sizing: The table and charts are intended to be used as a guideline for Residential applications only.
The information is based on conventional window space (<15%), insulation and building construction (8 ft.
ceiling height). When including a finished basement, use 1/2 of the finished basement square footage with
the rest of the area being calculated.
Mobile/Manufactured Home Sizing: Refer to the Date Plate located in the electrical box or kitchen cabinets. For
further assistance, call Hamilton's customer service department (800) 879-0123.
SQ. FOOTAGE
Equipment Sizing Guide
Use the map above to determine your region and compare to the chart below to find your application size.
/