Summary
Summary
1 GENERAL FEATURES 6
1.1 PROPER USE AND SAFETY CONDITIONS ........................................................................................6
1.2 GENERAL VIEW & CONNECTIONS ..................................................................................................... 6
1.3 FRONT PANEL DEFINITIONS ..............................................................................................................7
2 INSTANTANEOUS MEASUREMENTS 8
2.1 SETTINGS MENU (SEt) .........................................................................................................................8
2.2 CLEAR MENU (CLR) ............................................................................................................................. 8
2.3 SAVE PROCEDURE ..............................................................................................................................9
2.4 DIMENSIONS (mm) ...............................................................................................................................9
3 TECHNICAL ESPECIFICATIONS 10
www.weg.net
6 | Electronic Multimeter - MMW03
1 GENERAL FEATURES
MMW03 is designed to measure current, voltage and frequency parameters in 3-phase systems.
Product Name Definition Order No.
MMW03 Electronic Multimeter 14386964
1.1 PROPER USE AND SAFETY CONDITIONS
Installation and wiring must be performed by authorized technicians in accordance with the instructions in
the user manual. Do not commission the device before proper wiring;
Make sure the device is de-energized before connecting to the mains;
Short circuit the k-l terminals of the current transformer in another location before disconnecting the
current transformers. Failing to do so will cause dangerous high voltages in the secondary terminals of
the current transformers;
Use a dry cloth to clean the device. Do not use alcohol, thinner or any abrasive materials;
Make sure all wiring is properly made before commissioning the device;
Do not open the device. There are no serviceable parts by the user;
Keep the device away from humidity, water, vibrations and dust.
CAUTION!
The manufacturing company may not be kept responsible for unfavorable incidents that arise out of the failure to follow the
above cautions.
1.2 GENERAL VIEW & CONNECTIONS
V1 V2 V3 I1 I2 I3 SEQ
I1
I2
I3
1
2
3
V
F
Hz
A
A
A
MMW03
Figure 1.1: Display
www.weg.net
Electronic Multimeter - MMW03| 7
CurrentVoltage CurrentVoltage
Figure 1.2: Connection diagram
1.3 FRONT PANEL DEFINITIONS
Figure 1.3: Display - functions
1, 2, 3, 4, 5
Indicators (7 segment displays).
6, 7, 8
Phase on/off LEDs. (V
1
,V
2
,V
3
).
9, 10, 11
Current on/off LEDs.(I
1
,I
2
,I
3
)
12
Sequence fault (SEQ)
13, 14, 15
Voltage Indıcators
16, 18, 20, 22
Kilo LEDs (k)
17, 19, 21, 23
Mega LEDs (M)
24
Right arrow key
25
Up arrow key
26
Left arrow key
27
Down arrow key
www.weg.net
8 | Electronic Multimeter - MMW03
2 INSTANTANEOUS MEASUREMENTS
Voltage (L-N and L-L), current and frequency values are shown in instantaneous menu. Up / down arrow keys
can be used to toggle between voltage monitoring menus.
2.1 SETTINGS MENU (SEt)
Ecras setings are made in the SEt menu. Pressing the right arrow key for> 1 sec will access the “SEt” menu.
There are 3 submenus in this menu:
1. Basic Settings Menu (bSc): This is the menu item where you make the current transformer ratio, voltage
transformer ratio and connection type settings.
Current transformer ratio (Ctr): The calculated currents are multiplied by the current transformer
ratio (Ctr) to be indicated on the displays.(1-5000);
Voltage transformer ratio (Utr): The calculated voltages are multiplied by the voltage transformer
ratio (Utr) to be indicated on the displays.(1.0-5000.0);
Connection (Conn): This menu is for the network connection settings. The connection type can be
selected as “StA” (3-phase 4-wire) or “dEL” (3-phase 3-wire).
2. Password Settings Menu (Sec): Use this menu item to turn the password protection on/off, set a
password activation time and change password settings editing options.
Password protection (Act): Password protection is turned on / off;
Password activation time (P t): After a successful login, the device will not ask for a password until
the “password activation time” has elapsed;
Password value (Pin).
3. Menu scroll setup (Scr): Menu Navigation is given as a name to command which is moving menu screen
to next one at the end of display time.
Act: If “YES” is selected, automatic menu navigation is activated 15 seconds after the device is turned
on or the last key is pressed. When the menu display period expires, the next menu (such as pressing
the down arrow key) is displayed on the screen. As long as no key is pressed, navigation is continued.
If “NO” is selected, this feature is turned off.
Menu display period (PEr): Each menu appears in the screen during the period that is adjusted in
PEr menu.
2.2 CLEAR MENU (CLR)
This menu is used to restore the device settings to factory settings.
OFF: Disables the clear process;
SETTINGS: Restores all settings to the factory settings.
UEr: Version
www.weg.net
Electronic Multimeter - MMW03| 9
2.3 SAVE PROCEDURE
Changing Value/Setting:
Press the right key to choose and blink the first variable of the mmenu. Press the up/down keys to choose
and blink the desired option/number. Then press the left button to complete your choice.
Saving:
Press the left key until you see the “SAU nO” display to confirm or discard the changes you made. Press
the right key to blink the “nO” sign. Use the up/down keys to change the “nO” to “YES. Then, press the left
key to store the changes.
2.4 DIMENSIONS (mm)
96.8
96.8
7.0
65.0
89.6
Figure 2.1: Dimensions
www.weg.net
10 | Electronic Multimeter - MMW03
3 TECHNICAL ESPECIFICATIONS
SUPPY
Voltage ...........................85..300V AC/DC
Frequency ......................45...65 Hz
Power Consumption........<6VA
MEASUREMENT INPUTS
Voltage ........................... 5..300V AC (L - N)
10..500V AC (L - L)
Current............................10mA..6A AC
Frequency........................45..65Hz
Connection Type............. 3 phase 4 wire, 3 phase 3 wire
OPERATING TEMPERATURE/ STORAGE TEMPERATURE / RELATIVE HUMIDITY
-20°C..+60°C / -30°C..+80°C / maximum 95% No Condensation
PROTECTION CLASS
IP20
Índice
Sumário
1 CARACTERÍSTICAS GENERALES 16
1.1 USO ADECUADO Y CONDICIONES DE SEGURIDAD .....................................................................16
1.2 VISIÓN GENERAL Y CONEXIONES ...................................................................................................16
1.3 DEFINICIONES DEL FRONTAL DEL APARATO ................................................................................ 17
2 MEDICIONES INSTANTÁNEAS 18
2.1 MENÚ DE CONFIGURACIONES (SEt) ............................................................................................... 18
2.2 MENÚ CLEAR (CLR) ........................................................................................................................... 18
2.3 PROCEDIMIENTOS DE GUARDADO ................................................................................................19
2.4 DIMENSIONES (mm) ..........................................................................................................................19
3 ESPECIFICACIONES TÉCNICAS 20
WEG Group - Automation Business Unit
Jaraguá do Sul - SC - Brazil
Phone: +55 47 3276 4000
automacao@weg.net
www.weg.net
Cod: 50066669 | Rev: 00 | Date (m/y): 07/2016
The values shown are subject to change without prior notice.
For those countries where there is not a WEG own operation, find our local distributor at www.weg.net.
WEG Worldwide Operations
ARGENTINA
San Francisco - Cordoba
Phone: +54 3564 421484
info-ar@weg.net
Cordoba - Cordoba
Phone: +54 351 4641366
weg-morbe@weg.com.ar
Buenos Aires
Phone: +54 11 42998000
ventas@pulverlux.com.ar
AUSTRALIA
Scoresby - Victoria
Phone: +61 3 97654600
info-au@weg.net
AUSTRIA
Markt Piesting - Wiener
Neustadt-Land
Phone: +43 2633 4040
watt@wattdrive.com
BELGIUM
Nivelles - Belgium
Phone: +32 67 888420
info-be@weg.net
BRAZIL
Jaraguá do Sul - Santa Catarina
Phone: +55 47 32764000
info-br@weg.net
CHILE
La Reina - Santiago
Phone: +56 2 27848900
info-cl@weg.net
CHINA
Nantong - Jiangsu
Phone: +86 513 85989333
info-cn@weg.net
Changzhou – Jiangsu
Phone: +86 519 88067692
info-cn@weg.net
COLOMBIA
San Cayetano - Bogota
Phone: +57 1 4160166
info-co@weg.net
ECUADOR
El Batan - Quito
Phone: +593 2 5144339
ceccato@weg.net
FRANCE
Saint-Quentin-Fallavier - Isère
Phone: +33 4 74
991135
info-fr@weg.net
GERMANY
Türnich - Kerpen
Phone: +49 2237 92910
info-de@weg.net
Balingen - Baden-Württemberg
Phone: +49 7433 90410
info@weg-antriebe.de
Homberg (Efze) - Hesse
Phone: +49 5681 99520
info@akh-antriebstechnik.de
GHANA
Accra
Phone: +233 30 2766490
info@zestghana.com.gh
INDIA
Bangalore - Karnataka
Phone: +91 80 41282007
info-in@weg.net
Hosur - Tamil Nadu
Phone: +91 4344 301577
info-in@weg.net
ITALY
Cinisello Balsamo - Milano
Phone: +39 2 61293535
info-it@weg.net
JAPAN
Yo
kohama - Kanagawa
Phone: +81 45 5503030
info-jp@weg.net
MALAYSIA
Shah Alam - Selangor
Phone: +60 3 78591626
info@wattdrive.com.my
MEXICO
Huehuetoca - Mexico
Phone: +52 55 53214275
info-mx@weg.net
Tizayuca - Hidalgo
Phone: +52 77 97963790
NETHERLANDS
Oldenzaal - Overijssel
Phone: +31 541 571080
info-nl@weg.net
PERU
La Victoria - Lima
Phone: +51 1 2097600
info-pe@weg.net
PORTUGAL
Maia - Porto
Phone: +351 22 9477700
info-pt@weg.net
RUSSIA and CIS
Saint Petersburg
Phone: +7 812 363 2172
sales-wes@weg.net
SOUTH AFRICA
Johan
nesburg
Phone: +27 11 7236000
info@zest.co.za
SPAIN
Coslada - Madrid
Phone: +34 91 6553008
wegiberia@wegiberia.es
SINGAPORE
Singapore
Phone: +65 68589081
info-sg@weg.net
Singapore
Phone: +65 68622220
watteuro@watteuro.com.sg
SCANDINAVIA
Mölnlycke - Sweden
Phone: +46 31 888000
info-se@weg.net
UK
Redditch - Worcestershire
Phone: +44 1527 513800
info-uk@weg.net
UNITED ARAB EMIRATES
Jebel Ali - Dubai
Phone: +971 4 8130800
info-ae@weg.net
USA
Duluth - Georgia
Phone: +1 678 2492000
info-us@weg.net
Minneapo
lis - Minnesota
Phone: +1 612 3788000
VENEZUELA
Valencia - Carabobo
Phone: +58 241 8210582
info-ve@weg.net
Cod: 14903954 | Rev: 00 | Data (m/a): 04/2019
Subject to change without prior notice. The information contained herein is the reference value.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

WEG MMW03 Serie User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI