HMS Anybus Wireless Bridge II Startup Manual

Type
Startup Manual
Anybus
®Wireless Bridge II
STARTUP GUIDE
SCM-1202-013/SP2167 EN 1.9 ENGLISH
Important User Information
Liability
Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB
of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We,
HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous
product development. The information in this document is subject to change without notice and should not
be considered as a commitment by HMS Industrial Networks AB. HMS Industrial Networks AB assumes no
responsibility for any errors that may appear in this document.
There are many applications of this product. Those responsible for the use of this device must ensure that
all the necessary steps have been taken to verify that the applications meet all performance and safety
requirements including any applicable laws, regulations, codes, and standards.
HMS Industrial Networks AB will under no circumstances assume liability or responsibility for any problems
that may arise as a result from the use of undocumented features, timing, or functional side effects found
outside the documented scope of this product. The effects caused by any direct or indirect use of such
aspects of the product are undefined, and may include e.g. compatibility issues and stability issues.
The examples and illustrations in this document are included solely for illustrative purposes. Because of the
many variables and requirements associated with any particular implementation, HMS Industrial Networks
AB cannot assume responsibility for actual use based on these examples and illustrations.
Intellectual Property Rights
HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product
described in this document. These intellectual property rights may include patents and pending patent
applications in the USA and other countries.
Anybus®is a registered trademark and Wireless Bridge IIis a trademark of HMS Industrial Networks AB.
All other trademarks mentioned in this document are the property of their respective holders.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Preparation 3 (16)
1 Preparation
1.1 About This Document
This document describes how to install Anybus Wireless Bridge II and set up a
basic configuration.
For additional documentation, configuration examples, FAQs, troubleshooting
guides and technical support, please visit www.anybus.com/support.
1.2 Document Conventions
The following formatting conventions are used in this document to indicate safety
information and other content of specific importance:
WARNING
This instruction must be followed to avoid a risk of death or serious injury.
Caution
This instruction must be followed to avoid a risk of personal injury.
This instruction must be followed to avoid a risk of reduced functionality
and/or damage to the equipment, or to avoid a network security risk.
This is additional information which may facilitate installation and/or
operation.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Preparation 4 (16)
1.3 Product Description
Anybus Wireless Bridge II provides wireless communication over WLAN and/or
Bluetooth®to wired networks.
Typical applications for Anybus Wireless Bridge II include:
Adding wireless cloud connectivity to industrial devices
Accessing devices from a laptop, smartphone or tablet
Ethernet cable replacement between devices
Note:
Bluetooth PAN (Personal Area Network) may not work with some devices due to
different implementations of Bluetooth by different manufacturers.
WLAN 5 GHz cannot be used at the same time as WLAN 2.4 GHz or Bluetooth.
1.4 Model Name – Certification Identifier
The model name consists of a model prefix followed by two designators for
interface configuration and functionality.
Prefix AWB3 Anybus Wireless Bridge II
Interface configuration A
B
Internal antenna, Dual M12
External antenna, Dual M12, RP-SMA
Functionality A
B
Ethernet with digital input
Ethernet w/o digital input
Example: AWB3AA = Anybus Wireless Bridge II with internal antenna, Ethernet
networking and digital input.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 5 (16)
2 Installation
2.1 Safety
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical)
band. Make sure that all medical devices used in proximity to this device
meet appropriate susceptibility specifications for this type of RF energy.
Caution
The M12 power and LAN connectors must be provided with tool operated
mechanical lock nuts that are tightened by the installer.
This product is recommended for use in both industrial and domestic
environments. For industrial environments it is mandatory to use the
functional earth connection to comply with immunity requirements. For
domestic environments the functional earth must be used if a shielded
Ethernet cable is used, in order to meet emission requirements.
This product contains parts that can be damaged by electrostatic
discharge (ESD). Use ESD prevention measures to avoid damage.
2.2 General Information
Make sure that you have all the necessary information about the capabilities and
restrictions of your local network environment before installation.
For optimal reception, wireless devices require a zone between them clear of
objects that could otherwise obstruct or reflect the signal. A minimum distance of
50 cm between the devices should also be observed to avoid interference.
For models with internal antenna the characteristics of the antenna should be
considered when choosing the placement and orientation of the unit.
See the Anybus Wireless Bridge II User Manual for more information.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 6 (16)
2.3 Mechanical Installation
Anybus Wireless Bridge II can be screw-mounted directly onto a flat surface or
mounted on a standard DIN rail using the optional DIN mounting kit.
All measurements are in mm.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 7 (16)
2.4 Connectors
Power Connector (A-coded male M12)
Pin Function
1 Power + (9–30 V)
2 Digital Input Ground
3 Power Ground
4 Digital Input + (9–30 V)
5 Functional Earth
The digital input can be used for additional functionality with advanced
configurations and to reset the unit. For more information please refer to the
Anybus Wireless Bolt/Bridge II AT Reference Guide.
If voltage is applied to the digital input for more that 10 seconds the unit
will be reset to factory defaults.
Signal wiring for the digital input must be carried in the same cable as
power and functional earth if wiring length exceeds 3 meters.
LAN Connector (D-coded female M12)
Pin Function Color coding (T568B)
1 Transmit + Orange/White
2 Receive + Green/White
3 Transmit - Orange
4 Receive - Green
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 8 (16)
2.5 LED Indicators
Status Indicators
LED Indication Description
PWR Off No power
Green Normal operation
WLAN
Off WLAN disabled or no power
Blue, blinking Access Point: No clients, awaiting connections
Blue Access Point: Connected to at least one client
Client: Connected to access point
Blue, flickering WLAN data activity (when connected)
Purple, blinking Client: Scanning for access points
Purple Client: Connecting to a detected access point
Red Unrecoverable error
LAN
Off No Ethernet connection
Yellow Ethernet link present
Yellow, flickering Ethernet data activity (when connected)
BT
Off Bluetooth disabled or no power
Blue, blinking NAP: No clients, awaiting connections
Blue NAP: Connected to at least one PANU client
PANU: Connected to NAP
Blue, flickering Bluetooth data activity (when connected)
Purple PANU: Trying to connect to NAP
Red Unrecoverable error
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 9 (16)
Link Quality/Mode Indicators
RSSI (WLAN Client) / Link Quality (Bluetooth PANU)
LED Description
No connection
A RSSI/Link Quality < 25 %
A B RSSI/Link Quality 25–50 %
A B C RSSI/Link Quality 50–75 %
A B C D RSSI/Link Quality > 75 %
These LEDs are also used when selecting an Easy Config mode and to indicate
update status in Recovery Mode.
See Easy Config, p. 11 and Recovery Mode LED Indications, p. 10.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Installation 10 (16)
2.6 MODE Button
The MODE button can be used to restart or reset the unit as well as for selecting
an Easy Config mode.
When the unit is powered on, press and hold MODE for >10 seconds and then
release it to reset to the factory default settings.
Recovery Mode
If the web interface cannot be accessed, the unit can be reset by starting in
Recovery Mode and reinstalling the firmware using Anybus Firmware Manager
II, which can be downloaded from www.anybus.com/support.
To enter Recovery Mode, press and hold RESET during startup.
Firmware updates should normally be carried out through the web
interface. Recovery Mode should only be used if the unit is unresponsive
and the web interface cannot be accessed.
Recovery Mode LED Indications
In Recovery Mode the Status LEDs will indicate firmware update status:
PWR Green Firmware update in progress
Green, blinking Waiting for valid firmware
WLAN +BT Alternating red/blue Firmware update in progress
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Configuration 11 (16)
3 Configuration
Anybus Wireless Bridge II is normally configured via the web interface or using
one of the pre-configured Easy Config modes.
Advanced configuration can be carried out by issuing AT commands via the web
interface or over a Telnet or RAW TCP connection to port 8080.
3.1 Web Interface
The web interface is accessed by pointing a web browser to the IP address of
the unit. The default address is 192.168.0.99.
The configuration settings are described in detail in the User Manual.
3.2 Easy Config
1. Power on the unit and wait for the Link Quality LEDs to light up and go out
again, then immediately press and release the MODE button.
2. Press MODE repeatedly to cycle through the Easy Config modes until the
desired mode is indicated by the A-B-C-D LEDs.
3. Within 20 seconds of step 2, press and hold MODE for 2 seconds. When the
button is released the unit will restart in the selected mode.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Configuration 12 (16)
3.2.1 Easy Config Modes
EC LED Role Description
1A Bluetooth PANU Configure as a client and scan for another
client (PANU to PANU).
2BReset configuration to factory defaults.
3A B Reset IP settings to factory defaults.
4CClient Wait for automatic configuration.
5A C WLAN AP Configure units in mode 4 as clients.
Restart as access point and connect clients.
6B C Bluetooth NAP
7A B C WLAN AP Configure units in mode 4 as clients.
Restart as access point and connect clients.
Apply PROFINET optimization to all units.
8D Bluetooth NAP
9A D Bluetooth PANU
Configure as a client and scan for another
client (PANU to PANU).
Apply PROFINET optimization to both units.
10 B D (any) Apply PROFINET optimization and restart.
11 A B D (any) Enable PROFIsafe mode.
The Easy Config modes are also described in detail when selected in the web
interface.
Anybus
®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Configuration 13 (16)
3.3 Factory Restore
Any one of these actions will restore the factory default settings:
Clicking on Factory Restore on the System Settings page
Executing Easy Config Mode 2
Issuing the AT command AT&F and then restarting the unit
Holding MODE pressed for >10 seconds and then releasing it
Applying voltage to the digital input for >10 seconds
Default Network Settings
IP Assignment Static
IP Address 192.168.0.99
Subnet Mask 255.255.255.0
Default Gateway 192.168.0.99
Internal DHCP Server Disabled
Default WLAN Settings
Operating Mode Client
Channel Bands 2.4 GHz & 5 GHz
Authentication Mode WPA/WPA2–PSK
Channel Auto
Bridge Mode Layer 3 IP forward
MIMO AWB3000: Disabled
AWB3010: Enabled (Disabled before FW version 1.6.3)
Default Bluetooth Settings
Operating Mode PANU (Client)
Local Name [generated from MAC address]
Connectable No
Discoverable No
Security Mode Just works
Bluetooth LE Disabled
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Configuration 14 (16)
3.4 Configuration Examples
More examples can be found at www.anybus.com/support.
3.4.1 Ethernet Bridge via WLAN or Bluetooth®
Configuration with Easy Config
This example describes how to connect two Ethernet network segments via
WLAN or Bluetooth using Easy Config.
Configuration
1. Power on the first unit and wait for the LEDs to light up and go out, then
press MODE and release it immediately.
2. Press MODE repeatedly until only LED Cis lit (Easy Config Mode 4), then
confirm by pressing and holding MODE for 2 seconds.
This unit will now be discoverable and open for automatic configuration.
3. Power on the second unit and wait for the LEDs to light up and go out, then
press MODE and release it immediately..
4. Press MODE repeatedly on the second unit until A+Care lit (Mode 5) for
WLAN, or B+C(Mode 6) for Bluetooth, then confirm by pressing and
holding MODE for 2 seconds.
This unit should now automatically discover and configure unit 1 as a WLAN
or Bluetooth client, and configure itself as an access point.
Unit 1 will automatically be assigned the first free IP address within the
same Ethernet subnet as unit 2.
Adding More Devices
Up to 6 additional clients can be added by repeating the procedure. Each new
client will be assigned the next free IP address within the current subnet.
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
Technical Data 15 (16)
4 Technical Data
4.1 Hardware Specifications
Order code AWB3000 AWB3010
Wired Interface type Ethernet
Antenna 3 internal antennas:
2.4 GHz
2.4 GHz MIMO
5 GHz
1 external antenna:
2.4 GHz + 5 GHz dual band
Maximum range 400 m (WLAN and Bluetooth)
Dimensions (LxWxH) 93 x 68 x 33.2 mm
Weight 120 g
Operating temperature -40 to +65 °C
Storage temperature -40 to +85 °C
Humidity EN 600068-2-78: Damp heat, +40 °C, 93 % humidity for 4 days
Vibration See datasheet
Pressure 850 to 1050 mB
Housing material Plastic (see data sheet for details)
Protection class IPX5
Mounting Screw mount or DIN rail using optional clip
Power connector M12 male A-coded
Ethernet connector M12 female D-coded
Power supply 9–30 VDC (-5 % +20 %)
Cranking 12 V (ISO 7637-2:2011 pulse 4)
Reverse polarity protection
Power consumption 0.7 W (idle), 1.7 W (max)
Anybus®Wireless Bridge IIStartup Guide SCM-1202-013/SP2167 EN 1.9
This page intentionally left blank
Anybus®Wireless Bridge II
Additional certification and compliance information
COMPLIANCE SHEET
This document does not include the complete instructions for the safe use of the described equipment.
Make sure that you have read and understood the safety instructions in the user documentation for the
described equipment before proceeding.
© 2018 HMS Industrial Networks SP2145 1.2 en-US / 2018-10-08 / 9894
EMC Compliance (CE)
This product is in compliance with the Radio Equipment Directive 2014/53/EU through
conformance with the following standards. The Declaration of Conformity can be found
at www.anybus.com/support.
Effective use of
frequency spectrum
EMC Safety
EN 300 328 V2.1.1
EN 301 893 V2.1.1
EN 300 440 V2.1.1
EN 61000-6-2:2005
EN 61000-6-3:2007 + A1:2011
EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
EN 60950-1:2006 + A11:2009 + A1:2010
+ A12:2011 + A2:2013
EN 62311:2008 (Wi-Fi)
EN 62479:2010 (Bluetooth)
Disposal and recycling
You must dispose of this product properly according to local laws and regulations.
Because this product contains electronic components, it must be disposed of
separately from household waste. When this product reaches its end of life, contact
local authorities to learn about disposal and recycling options, or simply drop it off at
your local HMS office or return it to HMS. For more information, see
www.hms-networks.com.
FCC Compliance Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20 cm between the radiator and
your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired
operation.
This product contains FCC ID: PVH0965
Any changes or modifications not explicitly approved by HMS Industrial
Networks AB could cause the module to cease to comply with FCC rules part
15, and thus void the user's authority to operate the equipment.
Industry Canada Statement
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20 cm between
the radiator and your body.
Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired
operation of the device.
Cet équipement est conforme aux limites d'exposition de rayonnement d'IC RSS-102 déterminées pour un
environnement non contrôlé. Cet équipement devrait être installé et actionné avec la distance minimum 20
cm entre le radiateur et votre corps.
Son utilisation est soumise aux deux conditions suivantes:
1. Cet appareil ne doit pas causer d’interférences et
2. il doit accepter toutes interférences reçues, y compris celles susceptibles d’avoir des effets
indésirables sur son fonctionnement.
This product contains IC ID: 5325A-0965
© 2018 HMS Industrial Networks SP2145 1.2 en-US / 2018-10-08 / 9894
Anybus®Wireless Bridge IICompliance Sheet 2 (3)
Other Certifications
Contains MIC ID: R 204-510009 (indoor use only)
IFETEL
Marca: Anybus
Modelo: AWB3
NOM-208-SCF1-2016
La operación de este equipo está sujeta a las
siguientes dos condiciones:
(1) es posible que este equipo o dispositivo no cause
interferencia perjudicial y
(2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su
operación no deseada.
© 2018 HMS Industrial Networks SP2145 1.2 en-US / 2018-10-08 / 9894
Anybus®Wireless Bridge IICompliance Sheet 3 (3)
Anybus®Wireless Bridge II
Additional certification and compliance information
COMPLIANCE SHEET
This document does not include complete instructions for the safe use of the described equipment. Make sure that
you have read and understood the original user documentation for the equipment before proceeding.
© 2018 HMS Industrial Networks AB SCM-1202-064 EN 1.0 / 2017-12-20 / 8544
UL Ordinary Locations (Ord.Loc.)
Anybus Wireless Bridge II modules are certified for use in ordinary locations in compliance with the
following standards:
UL 61010-1 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT,
CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS - Edition 3 - Revision
Date 2015/07/15
UL 61010-2-201 STANDARD FOR SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR
MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-201: PARTICULAR
REQUIREMENTS FOR CONTROL EQUIPMENT - Edition 1 - Issue Date 2014/01/24
CSA C22.2 NO. 61010-1-12 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR
MEASUREMENT, CONTROL, AND LABORATORY USE. PT. 1, GENERAL REQUIREMENTS -
Edition 3 - Revision Date 2015/07/01
CSA C22.2 NO. 61010-2-201:14 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR
MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-201: PARTICULAR
REQUIREMENTS FOR CONTROL EQUIPMENT - Edition 1 - Issue Date 2014/01/01
The certification number of Anybus Wireless Bridge II certified modules according to Ord.Loc. certification
is:
• E214107
According to the standards listed above, Anybus Wireless Bridge II modules are certified with the following
marking:
According to the standards listed above, the Anybus Wireless Bridge II modules shall be supplied by a
CLASS 2 / SELV classified power supply.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

HMS Anybus Wireless Bridge II Startup Manual

Type
Startup Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages