Husqvarna 01935 Owner's manual

Category
Power generators
Type
Owner's manual

This manual is also suitable for

Husqvarna
01935 1365GN
Owner's Manual / Manual del Propietario
_Read this manual carefully and become familiar with your generator.
Know the applications, the limitations and any hazards involved.
_Lea este manual de manera cuidadosa y familiaricese con su generador.
Conozca sus usos, sus limitaciones y cualquier peligro relacionado con el mismo.
0 3 Part Number 531 30 00-69
Safety Rules
TABLE OF CONTENTS
SafetyRules.................................. 2-4
Know Your Generator ........................... 5
Assembly.................................... 6-7
Operation .................................. 8-13
Maintenance.................................. 14
Storage...................................... 15
Notes ....................................... 16
Troubleshooting ............................... 17
Schematic/Wiring Diagram .................... 18-19
Replacement Parts........................... 20-24
Warranty .................................... 25
EQUIPMENT
DESCRIPTION
_Read this manual carefully and become familiar
with your generator. Know the applications, the
limitations and any hazards involved.
This generator isan engine-driven, revolving field,
alternating current (AC) generator. It wasdesignedto
supply electrical power for operating compatible electrical
lighting,appliances,tools andmotor loads.Thegenerator's
revolving field isdriven at about 3,600rpm by a single-
cylinder engine.
CAUTION! DO NOT exceed the generator's
wattage/amperage capacity.See"Don't Overload
Generator" on page 13.
Every effort hasbeen madeto ensure that informationin
this manualisaccurate and current. However, we reserve
the right to change,alter or otherwise improvethe product
and this document at anytime without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency.For warranty information refer to the
engine owner's manual.
the State of California a spark arrester isrequired by law
Section 4442 of the California PublicResourcesCode).
)ther states may havesimilar laws.Federallawsapply on
Federallands.Themuffler isequipped with aspark arrester:
t must be maintained ineffective working order.
Replacementspark arresters may be obtained by calling
1-877-224-0458.
SAFETY RULES
A his is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol (_.) isused with a signalword
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety messageto alert you to hazards.DANGER indicates
a hazard which, if not avoided,will result in death or
serious injury.WARNING indicatesa hazardwhich, ifnot
avoided,could result in death or serious injury.
CAUTION indicatesa hazardwhich, ifnot avoided,might
result in minor or moderate injury.CAUTION, when used
without the alert symbol, indicatesa situation that could
result in equipment damage.Follow safety messagesto
avoid or reduce the risk of injuryor death.
WARNING
The engine exhaust from this product contains I
chemicals known to the State of California to cause
cancer, b rth defects, or other reproduct ve harm.
Hazard Symbols and Meanings
Electrocution Electrical Shock Electrical Shock
Toxic Fumes
Explosive Pressure
Explosion Fire
Chemical Burn Hot Surface
Safety Rules
DANGER
Operate generator ONLY outdoors.
Keepat least 2 feet of clearance on all sidesof generator for
adequate ventilation.
DO NOT operategenerator insideanybuildingor enclosure,
includingthe generatorcompartmentof arecreationalvehicle(RV).
DANGER
National Electric Code requires generator to be properly
grounded to an approved earth ground. Call an electrician for
localgrounding requirements.
DANGER
When usinggenerator for backup power, notify utility
company.Use approved transfer equipment to isolate
generator from electric utility.
Use aground fault circuit interrupter (GFCi) in anydamp or
highly conductive area,such asmetal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn
frayed,bare or otherwise damaged.
DO NOT operate generator in the rain or other forms of
precipitation.
DO NOT handle generator or electrical cords while standing
inwater, while barefoot, or while handsor feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
IKWARNING
Thisgenerator does not meet U. S.Coast Guard Regulation
33CFR-183and should not be used on marine applications.
Failureto use the appropriate U.S.Coast Guard approved
generator could result in bodily injuryand/or property
damage.
DANGER
DO NOT allow any open flame, spark, heat,or lit cigarette
during andfor several minutes after charginga battery.
Wear protective goggles,rubber apron, and rubber gloves.
WARNING
WHEN ADDING FUEL:
Turn generator OFF and let it cool at least 2 minutes before
removing gas cap. Loosen cap slowly to relieve pressure in tank_
Fill fuel tank outdoors.
DO NOT overfill tank.Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
eVHEN OPERATING EQUIPMENT:
DO NOT tip engine or equipment at angle which causes fuel
to spill.
This generator is not for use in mobile equipment or marine
applications.
'HEN TRANSPORTING OR REPAIRING EQUIPMENT:
Transportlrepair with fuel tank EMPTY or with fuel shutoff
valve in the OFF position.
Disconnect spark plug wire.
eVHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK:
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.
Safety Rules
WARNING
;ENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
, WARNING
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
CAUTION
DO NOT tamper with governed speed.Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
CAUTION
See"Don't Overload Generator" on page 13.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
CAUTION
Use generator only for intended uses.
tf you have questions about intended use,askyour Husqvarna
dealer or contact customer service at 1-877-224-0458.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insertany objects through cooling slots.
tf connected devices overheat, turn them off and disconnect
them from generatoc
Shut off generator if.'
-electrical output islost;
-equipment sparks,smokes,or emits flames;
-unit vibrates excessively.
Features and Controls
KNOWYOUR GENERATOR
Read this owner's manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Engine Switch Recoil Starter
OilFill
FuelTank
Choke Lever
12Volt DC,10Amp
Receptacle
Air Cleaner
Idte Control Switch
120Volt AC, 20 Amp GFCI
Duplex Receptacles
Circuit
Breakers (AC)
120/240Volt AC,
30Amp Receptacle
Spark Arrester Muffler
12Volt DC, I0 Amp Receptacle -- Rechargea discharged
12Volt automotive type battery through this receptacle.
120Volt AC, 20 Amp GFCI Duplex Receptacles --
May be usedto supply electrical power for the operation
of 120Volt AC, 20 Amp, single phase,60 Hz electrical,
lighting,appliance,tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle -- May
be usedto supply electrical power for the operation of
120and/or 240VottAC, 30Amp, singlephase,60 Hz
electrical, lighting,appliance,tool and motor loads.
Air Cleaner -- Uses a dry type filter element to limit the
amount of dirt and dust suckedinto the engine.
Choke Lever -- Used when starting a cold engine.
Circuit Breakers (AC) -- Pushto reset circuit breakers
are provided to protect the generator againstelectrical
overload.
Grounding
Fastener
FuelTank -- Capacity of seven(7) U.S.galtons.
Grounding Fastener -- Contact your local electrician
for grounding requirements (see page8).
Hour Meter -- Displaysand records how many hours
your generator hasrun (up to 9,999.9).
Idle Control Switch --The idle control runs the engineat
normal (high) speedswhen there isa load present and runs
the engineat idle (low) speedswhen a load isnot present.
Oil Fill --Add engine oil here.
Recoil Starter-- Used to start the engine.
Engine Switch -- Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch off engine.
Spark Arrester Muffler -- Exhaust muffler lowers
engine noise and isequipped with a spark arrester screen.
Assembly
ASSEMBLY
Your generator requires some assembly and isready for
use after it hasbeen properly serviced with the
recommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-877-224-0458.
Remove Generator From Carton
I. Set carton on a rigid fiat surfacewith "This Side Up"
arrows pointing upward.
2. Carefully open top flapsof shippingcarton.
3. Cut down corners at one end of carton from top to
bottom and laythat side of carton down fiat
4. Removeall packing material, carton fillers, etc.
5. Removegenerator from shippingcarton.
Carton Contents
Check all contents. Ifany parts are missingor damaged,call
the generator helpline at 1-877-224-0458.
The generator
Generator and engine owner's manuals
Locking 30 Amp plug
Battery charge cables
Engineoil
Wheel kit
Install Wheel Kit
The wheel kit isdesignedto greatly improvethe portability
of your generator.
NOTE: Wheel kit is not intendedfor over-the-road use.
You will need a socket wrench with I/2" or 13mm sockets
and a needle-nose pliers to install this kit.
Refer to Figure I and install the wheel kit as follows:
I. Placethe bottom of the generator frame on a fiat, even
surface.Temporarily place unit on blocks to ease
assembly.
Handle Pin
Nylon Washer
45 mm Ca
Flat Washer
Handle
Use existing hardware
to attach left side of
support legto unit
Nut
Vibration Mount
Wheel
FlatWasher
Axle
20 mm Cap Screw
/
E-Ring
3/4" Cap Screw Nut
Assembly
2. Slide axle through both axle mounting brackets on
cradle frame, asshown in Figure I.
3. Slide a wheel over the axle.
BEFORE STARTING THE
ENGINE
NOTE: Be sure to install both wheels with the air
pressure valve on the outboard side.
4. Placethe e-ring onto the groove in the axle.You may
add the fiat washer if desired.
NOTE: Use retaining pins insteadof e-clip, if applicable.
Add Engine Oil and Fuel
Placegenerator on a levelsurface.
Refer to engine owner's manualand follow oil and fuel
recommendations and instructions.
CAUTION
5. Placeone end of the needle nose pliers on the bottom
of the axle and the other end of the pliers on top of
the e-ring.Seatthe e-ring by pressingthe pliers closed.
6. Repeat step 3 through 5 to secure second wheel.
7. Removethe temporary blocks.
8. Attach the vibration mounts to the support leg with
3/4" capscrewsand lock nuts.
9. To aid support legassembly,rest generator on cradle,
engine end down. Removethe existing hardware from
the left unit vibrationmount with 13mmwrench. Use
the samehardware to attach the support leg.
10. Attach the other side of the support legwith a 20 mm
cap screw and lock nut. Restgenerator on wheels and
support leg.
Refer to engine manualfor oil andfuel fill information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
NOTE: Check oil often during engine break-in. Refer to
engine owner's manualfor recommendations.
NOTE:The generator assembly rotates on apretubricated
and sealed baitbearing that requires no additional
lubricationfor the life of the bearing.
I I. Attach handlesto handle brackets on generator frame,
as shown in Figure I,with 45 mm capscrews,flat
washers,nylon washers,and lock nuts.
12. Loop handle pins to generator frame as shown in
Figure I. Raise handles and insert handle pins to move
generator.
13. Check eachfastener to ensure it is secure and the
tires are inflated between 15-40 PSI.
Operation
GROUNDING THE
G EN ERATO R
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes mayalso require proper grounding of the
unit. For that purpose, a GROUNDING FASTENERis
provided on the generator end (Figure 2).
Fastener
Generally,connecting a No. 12AWG (American Wire
Gauge) stranded copper wire to the grounding fastener and
to an earth-driven copper or brassgrounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keepthe grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely.Consult with a localelectrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if aground fault condition exists in the generator or
in connected electrical devices,especiallywhen the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING THE
G EN ERATO R
CAUTION
See"Don't Overload Generator" on page 13.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Starting the Engine
Disconnectall electrical loads from the generator. Use the
following start instructionsteps by numerical order:
I. Make sure unit ison a levelsurface.
IMPORTANT: Failureto start and operate uniton a level
surface will causethe unit not to start or shut down during
operation.
2. Turn fuel valve to "On" position (Figure 3).The fuel
valve handle should be vertical(pointing toward
ground) for fuel to flow.
Fuel Valve is shown
in the "On" position
3. Make sure IdleControl switch isin"Off" position
(Figure 4).
I_ImE_L_Ill [IL_l _"_a
IDLE
Operation
4. Start engine according to instructions given in engine
owner's manual
NOTE: If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, makesure unit is on a
level surface and check for proper oll level in crankcase.
This unit may be equipped with a low oil protection device.
See engine manual.
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes after
starting.
Plugin and turn on the desired 120and/or 240 VottAC,
single phase,60 Hz electrical loads.
DO NOT connect 240Vott loads to the 120Volt duplex
receptacles.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loadsto the generator.
DO NOT OVERLOADTHE GENERATOR. See
"Don't OverloadGenerator" on page 13.
Stopping the Engine
I. Unplug ALL electrical loadsfrom generator panel
receptacles.NEVER start or stop engine with electrical
devices plugged in and turned ON.
2. Move idle control switch to "Off" position.
3. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
4. Turn engine off according to instructions given in the
engine owner's manual.
5. Move fuel valve to "Off" position.
Operating Automatic Idle Control
This switch isdesignedto greatly improvefuel economy.
When this switch is turned ON, the engine will only
run at its normal high governed enginespeed when an
electrical load is connected.When an electrical load is
removed,the enginewill run at a reduced speed.With the
switch off, the engine will run at the normal high engine
speed.Always have the switch off when starting and
stopping the engine.
Charging a Battery
Your generator hasthe capability of recharging a discharged
12Volt automotive or utility style storage battery. DO
NOT use the unit to chargeany 6Volt batteries. DO NOT
usethe unit to crank an engine havinga discharged battery.
DANGER
DO NOT allow anyopen flame, spark, heat,or lit cigarette
during andfor several minutes after charginga battery.
Wear protective goggles,rubber apron, and rubber gloves.
To recharge 12Volt batteries, proceed as follows:
I. Check fluid levelin all battery cells.If necessary,add
ONLY distilled water to cover separators in battery
cells.DO NOT use tap water.
2. If battery isequipped with vent caps,make sure they
are installedand are tight.
3. If necessary,clean battery terminals.
4. Connect battery charge cable connector plug to panel
receptacle identifiedby the words "12-VOLTS D.C".
5. Connect battery charge cable clamp with red handle
to the positive (+) battery terminal (Figure5).
12 VOLT D.C.
RECEPTACLE
+
POS NEG
12 VOLT BA'R'ERY
Operation
6. Connect battery chargecable clamp with black handle
to the negative (-) battery terminal (Figure5).
7. Start engine.Let engine run while battery recharges.
8. When battery hascharged,shut down engine
NOTE: Use an automotive hydrometer to test battery
state of charge andcondition. Follow the hydrometer
manufacturer's instructionscarefully.Generally,a battery is
considered to be at 100%state of chargewhen specific
gravity of itsfluid (as measured by hydrometer) is 1.260or
higher.
COLD WEATH ER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your generator may
experience icingof the carburetor and/or the crankcase
breather system.
Build a structure that wilt enclose three sides and the top
of the generator:
I. Make sure entire muffler-side of generator is exposed.
Note that your generator mayappear different from
that shown in Figure 6.
Wind
2. Ensure a minimum of two feet clearance between open
side of box and nearest object.
3. Face exposed end away from wind and elements.
4. Enclosure should hold enough heat created by
generator to prevent problems.
DANGER
OperategeneratorONLYoutdoors.
Keepat least2 feet of clearanceon all sidesof generatorfor
adequateventilation.
DO NOT operategeneratorinsideanybuildingorenclosure,
includingthegeneratorcompartmentofarecreationalvehicle(RV).
Removegeneratorfrom shelterwhentemperatureisabove
40°F[4°q.
m
Operation
RECEPTACLES
CAUTION
_:I P_tkv_ e* , " , m
NEVERattempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See"Don't Overload
Genera_r'.
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA LI4-30 plug with this receptacle.Connect a
4-wire cord set rated for 250Volt AC loads at 30 Amps (or
greater) (Figure 7).You can usethe same 4-wire cord if you
)lan to run a 120Volt load.
4-WireCord Set
/-
' (Neutral)
IPE_ _ 1[*TA_m
Y (Hot) | X (Hot)
NEMA L14-30 /-_ Ground (Green)
This receptacle powers 1201240Volt AC, 60 Hz,single
phaseloadsrequiring up to 6,500 watts of power (6.5 kW)
at 30 Amps for 120Volts or 240Volts.The outlet is
protected bya push-to-reset circuit breaker.
120 Volt AC, 20 Amp, GFCI Duplex
Receptacles
Eachduplex receptacle (Figure 8) isprotected against
overload by apush-to-reset circuit breaker.
•l I
•l I
Use each receptacle to operate 120Volt AC, single-phase,
60 Hz electrical loadsrequiring up to 2,400 watts (2.4 kW)
at 20Amps of current. Use cord sets that are rated for
125Volt AC loads at 20Amps (or greater).
12Volt DC, I 0 Amp Receptacle
Thisreceptacle (Figure 9) allows you to recharge a 12Volt
automotive or utility style storage battery with the battery
chargecables provided.
Thisreceptacle can not recharge 6Volt batteries and can
not be usedto crank anenginehavingadischarged battery.
See"Charging a Battery" on page9 before attempting to
recharge a battery.This outlet isprotected by a l0 Amp
self-resetting circuit breaker.
I
Operation
Ground Fault Protection
This unit isequipped with a Ground FaultCircuit
Interrupter (GFCI).This device meets applicablefederal,
state and local codes.
The GFCI protects againstelectrical shock that may be
caused if your body becomesa path which electricity
travels to reach the ground.This could happen if you touch
a "Live" applianceor wire, or are touching plumbing or
other materials that connect to the ground.
When protected by a GFCI, one maystill feel a shock, but
the GFCI should cut current off quickly enough so that a
person in normal health should not suffer any serious
electrical injury.
DANGER
The GFCI will not protect you againstthe following situations:
-Line-to-line shocks;
-Current overloads or line-to-line short circuits.
The fuse or circuit breaker at the control panel must provide
such protection.
Testing the GFCI
Testyour GFCI outlet every month and before use,as
follows:
Pushthe black"Test" button.The red "Reset" button
should pop out,which should allow no power to reach
the outlet. Use a test lamp in eachoutlet to test this.
CAUTION
DO NOT useanyoutletson the circuit.
Callaqualifiedelectrician.
If the GFCI tests good, restore power by pressingthe
"Reset" button firmly until it is fully in placeand locks in
that position. If the GFCI outlet does not reset
properly, do not use the outlet. Call a local service
center.
If the GFCI trips by itself at anytime, reset and test the
outlet. If the reset button does pop out when the
test button ispressed, do not use the outlet. Call
a local service center.
m
Operation
DON'T OVERLOAD
G EN ERATO R
Capacity
You must make sure your generator cansupply enough
rated (running) and surge (starting) watts for the items you
will power at the sametime. Follow these simple steps:
I. Selectthe itemsyou wilt power at the sametime.
2. Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your itemsrunning. SeeFigure 10.
3. Estimate how many surge (starting) watts you wilt
need.Surge wattage isthe short burst of power
needed to start electric motor+driven tools or
appliancessuch asa circular saw or refrigerator.
Becausenot all motors start at the sametime, total
surge watts can be estimated by addingonly the
item(s)with the highest additional surge watts to the
total rated watts from step 2.
Example:
Tool or Appliance
Window Air
Conditioner
Refrigerator
Deep Freezer
Television
Light (75 Watts)
Rated (Running)
Watts
1200
800
500
500
75
3075 Total
Running Watts
Total Rated (Running)Watts = 3075
Highest Additional SurgeWatts = 1800
Total Generator Output Required = 4875
Additional Surge
(Starting)Watts
1800
1600
50O
1800 Highest
SurgeWatts
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when addingelectrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safeway to managegenerator power isto sequentially
add loads asfollows:
I. With nothing connected to the generator, start the
engine asdescribed in this manual.
2. Plugin and turn on the first load,preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached deviceoperates properly).
4. Plug in and turn on the next load.
5. Again,permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity.Take
specialcare to consider surgeloads in generator capacity,
asdescribed above.
Tool or Appliance
Essentials
Light Bulb - 75 watt
Deep Freezer
SumpPump
Refrigerator/Freezer - 18Cu. Ft.
Water Well Pump- I/3 HP
Heating/Cooling
Window AC - IO,O00BTU
Window Fan
FurnaceFanBlower - I/2 HP
Kitchen
Microwave Oven - 1000Watt
Coffee Maker
Electric Stove - SingleElement
Hot Plate
Family Room
DVD/CD Player
VCR
Stereo Receiver
Color Television - 27"
Personal Computer w/I 7" monitor
Other
SecuritySystem
AM/FM Clock Radio
GarageDoor Opener - I/2 HP
Electric Water Heater - 40 Gallon
DIY/Job Site
Quartz Halogen Work Light
Airless Sprayer - I/3 HP
Reciprocating Saw
Electric Drill - I/2 HP
Circular Saw- 7 I/4"
Miter Saw- 10"
Table Planer - 6"
Table Saw/RadialArm Saw- 10"
Air Compressor - I-I/2 HP
Rated*
(Running)
Watts
75
5O0
8O0
8O0
1000
12O0
3OO
8O0
1000
1500
1500
25O0
Ioo
Ioo
450
5O0
8O0
Additional
Surge
(Starting)
Watts
5O0
1200
1600
20O0
1800
6O0
1300
180
300
480 520
40O0
1000
600 1200
960 960
1000 1000
1500 1500
1800 1800
1800 1800
2000 2000
2500 2500
*Wattages listed are approximate only. Check toot or
appliance for actual wattage.
m
Maintenance
SPECIFICATIONS
Maximum SurgeWatts ................. 8,125 watts
Continuous Wattage Capacity ........... 6,500 watts
Power Factor .............................. 1.0
Rated Maximum Continuous AC Load Current:
At 120Volts ....................... 54.2Amps
At 240 Volts ....................... 27.I Amps
Phase................................. I-phase
Rated Frequency ....................... 60 Hertz
FuelTank Capacity................... 7 U.S.gallons
ShippingWeight ......................... 205 Ibs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on atimely
basis;that all discrepancies are corrected; andthat the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
Engine Maintenance
See engine owner's manualfor instructions.
CAUTION
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE.CONSERVERESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with dirt,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and causeproblems. In
addition, ifwater enters generator through cooling air slots,
some of the water wilt be retained in voidsand cracks of
the rotor and stator winding insulation.Waterand dirt
buildup on the generator internalwindings will eventually
decreasethe insulationresistance of these windings.
ENERATOR
WARNING
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
Generator Cleaning
Use a damp cloth to wipe exterior surfaces clean.
CAUTION
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
m
Storage
STO RAG E
The generator should be started at least once every seven
claysand allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days,usethe following guidelinesto prepare it for
storage.
Generator Storage
Clean the generator as outlined in "Generator Cleaning".
Check that cooling air slots and openings on generator
are open and unobstructed.
WARNING
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the
cover on the equipment.
Engine Storage
See engine owner's manualfor instructions.
Other Storage Tips
To prevent gum from forming in fuel system or on
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
DO NOT store fuel from one season to another unless
it has been treated as described above.
Replace fuel container if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
Store unit in a clean and dry area.
I
Troubleshooting
TROUBLESHOOTING
Problem
Engine is running, but no AC
output is available.
Cause
I. Circuit breaker isopen.
2. Poor connection or defective
cord set.
3. Connected device isbad.
Solution
I. Resetcircuit breaker.
2. Check and repair.
.
4. Fault in generator. 4.
I. Short circuit in a connected load. I.
Engine runs good but bogs down
when loads are connected. 2. Generator is overloaded. 2.
3. Shorted generator circuit. 3.
I. Out of gasoline. I.
Engine shuts down during 2. Low oil level 2.
operation.
Engine lacks power. Load is too high. See
Connect another devicethat isin
good condition.
Contact localservice facility.
Disconnect shorted electrical
load.
See "Don't Overload Generator".
Contact localservice facility.
Fillfuel tank.
Fill crankcaseto proper level or
placegenerator on a level surface.
"Don't Overload Generator".
m
Schematic
SCHEMATIC
55A
//PI-6 12V DC
HOURMETER
55
12VDC
CB5 10A
13 _ 13A (_ 55
IOA
1P
IDLE CONTROL
CIRCUIT BOARD
IDLE
CONTROL
COIL
J,
11
155
156
IDLE
CONTROL
SWITCH
SCHEMATIC
11
P1-2
o 11
o 22 VOLTAGE
REGULATOR
2 6
FIEL_
POWER
. ._TB-3
CT
IIA
11A
EE
s I20V
GFD!
GR
2OA
1P
WHITE
POWER
;P1-3
TB-122 _TB-2
155
156
P
E2 120V
m S 2OA
GFCI
IP
12O/24OV
3OA
_y 44A
t
P PI-4
CB2
25A
IP
CT
m
Wiring Diagram
WIRING DIAGRAM
CB1 CS£ CB3 CS4
88
@F1
13A
2_
44A
11
13
22
L3 128 IIA
0 A
44A
i 3 155 llC
4
CB s aa
6
NI]rE_ pI]EITIVE BRUEH IS CLDEEET TI] BEARIN@
6
WIRE DIAGRAH
22
2
ETH
33
11
1 1133
STAT[IR
55A
66
13
SW
m
Exploded Views
PARTS LIST - MAIN UNIT
Item Part # Description
I NI92958AGS CRADLE
2 82857GS MOUNT, Vibration
3 N92531GS SUPPORT,Engine
4 190220GS HOUSING, EngineAdapter
5 45771GS NUT
6 NSP ASSY,AIternator (see page 22)
7 N92731GS SUPPORT,Eng/Muffler
8 96796GS WASHER
9 92609GS MOUNT, Vibration
10 190274BGS SCREW
II 187365JGS SCREW
12 189160GS NUT
13 22142GS SCREW
14 193048GS BRACKET,Muffler
15 23762GS WASHER
16 66476GS SCREW,w/Lock Washer
17 192569GS MUFFLER
18 31579GS SPACER
19 83083GS SCREEN,SparkArrest
20 B4986GS DECAL, Ground
21 67989GS NUT, FlangeSerrated
22 192981GS SHIELD,Heat
23 193058GS DECAL, Panel,Control
24 192983GS SHIELD,Heat
25 193157GS HARNESS,Wire, Power
26 74908GS SCREW
27 193049GS ASSY,Control Panel(see page23)
28 191435GS DECAL, FuelShut-off
29 86292GS SCREW
30 2253 IGS SCREW
31 191436GS DECAL, Hot Muffler
32 43107GS SCREW
Item Part # Description
33 22129GS WASHER, Lock
34 186347GS COVER,Bearing Carrier
35 23762GS WASHER
36 86494GS SCREW,Wing
37 192376GS SCREW
38 56893GS SCREW
39 193057GS DECAL, Unit
40 NSP GASKET,Muffler (with Item 900)
41 192980GS KIT,VLV,FUEL,SRV
43 83465GS GROMMET,Tank
44 7883 lAGS SCREW
45 B4363GS CAP,Fuel Gauge
46 85000GS CLIP,Insulation
47 193399GS ASSY,Tank,Fuel (includes Items 41,
50,51 &52)
48 14353621GS WIRE, Ground
49 26850GS WASHER
50 188333GS DECAL, Instruction, Fuel Level
51 92982GS DECAL, Danger
52 189274GS DECAL, Start Instructions
53 85652GS MOUNT, Vibration
54 92665GS INSULATION
55 B2153GS SCREW
900 NSP ENGINE
Parts Not Illustrated
43438GS PLUG,250V 30A, 4 Prong
BB3061BGS OIL, Bottle
65787GP CABLE,Battery Charge
B1464GS MANUAL, Engine
193174GS MANUAL, Owner's
t
Exploded Views
EXPLODED VI EW AND PARTS LIST - ALTERNATOR
5 4
\
\
\
\
\
\
6
7
\\
\
9
\
\
\
\
\
2
8
16
\
\, 1,5
10
Item Part #
I 186059GS
2 192919GS
3 192920AGS
4 193336GS
5 86308HGS
6 66386GS
7 66849GS
8 22694GS
9 81917GS
10 19105lAGS
12 23762GS
13 192403XGS
14 189769GS
15 65795GS
16 66849AGS
Description
ADAPTER, Mounting,Alternator
ROTOR
STATOR
RBC,(with O-Ring, p/n 189197GS)
SCREW
ASSY,Holder, Brush
SCREW
RECEPTACLE,6 pin
PIN,Roll
ASSY,Wire, Ground
WASHER
WIRE, Ground
REGULATOR,Voltage,AVR
RECTIFIER
SCREW
m
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Husqvarna 01935 Owner's manual

Category
Power generators
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages