Mediana YM1000 User manual

Type
User manual
OPERATOR’S MANUAL
For YM1000 Vital Signs Monitor
EURepresentative
TECNOMED2000S.L.
Valencia,25‐28012MadridSpain
Manufacturer
MedianaCo.,Ltd.
WonjuMedicalIndustryPark,16501Donghwari,
Munmakeup,Wonjusi,Gangwondo,Korea
Tel:(82)25423375(82)337425400
Fax:(82)25427447(82)337425483
YM1000OperatorsManual
RevisedDate:0907
PartNumberRevision:A70792
PrintedinKorea
Copyright©20052007MedianaCo.,Ltd.Allrightsreserved.   
Notice
Thisdocumentcontainsproprietaryinformationthatisprotectedbycopyright.AllRightsReserved.
Reproduction,adaptation,ortranslationwithoutpriorwrittenpermissionisprohibited,exceptas
allowedunderthecopyrightlaws.
Warranty
Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.
Medianamakesnowarrantyofanykindwithregardtothismaterial,including,butnotlimitedto,the
impliedwarrantiesormerchantabilityandfitnessforaparticularpurpose.
Medianashallnotbeliableforerrorscontainedhereinorforincidentalorconsequentialdamagesin
connectionwiththefurnishing,performance,oruseofthismaterial.
RevisionHistory
Thedocumentationpartnumberandrevisionnumberindicateitscurrentedition.Therevisionnumber
changeswhenaneweditionisprintedinaccordancewiththerevisionhistoryofthedocumentation.
Minorcorrectionsandupdateswhichareincorporatedatreprintdonotcausetherevisionnumberto
change.Thedocumentpartnumberchangeswhenextensivetechnicalchangesareincorporated.
Contents
Figures
Tables
YM1000 Operators Manual i
SafetyInformation....................................................................................................................................1
GeneralSafetyInformation...............................................................................................................1
Warnings ..............................................................................................................................................1
Cautions...............................................................................................................................................3
Introduction ...............................................................................................................................................5
FeaturesforYM1000 ..........................................................................................................................5
IntendedUseforYM1000..................................................................................................................6
AboutThisManual ............................................................................................................................6
DescriptionofControls,Indicators,SymbolsandDisplays ............................................................7
IdentificationofFrontPanelControlsandSymbols .....................................................................7
IdentificationofRearPanelComponentsandSymbols ...............................................................8
DescriptionofYM1000Symbols/Indicators ...................................................................................9
DescriptionofYM1000Controls ....................................................................................................13
SettinguptheMonitor...........................................................................................................................15
UnpackingandInspection ..............................................................................................................16
ListofComponents..........................................................................................................................16
PowerCableConnections ...............................................................................................................17
MeasurementCableConnections ..................................................................................................18
BatteryOperation....................................................................................................................................21
OperatingYM1000onBatteryPower ............................................................................................21
ChargingaLowBattery ..................................................................................................................22
LowBatteryIndication ....................................................................................................................22
UsingtheMonitor...................................................................................................................................23
TurningontheMonitor ...................................................................................................................23
PerformingPowerOnandSelfTest(POST).................................................................................24
SettingDateandTime .....................................................................................................................26
SettingPatientType .........................................................................................................................27
SettingNIBPUnits ...........................................................................................................................28
SettingTemperatureUnitsandModes..........................................................................................29
SettingPulseToneVolume..............................................................................................................30
SettingAlarmVolume .....................................................................................................................31
ResettingtoFactoryDefaults..........................................................................................................32
NIBPMonitoring ....................................................................................................................................33
General...............................................................................................................................................34
SetupConnections............................................................................................................................35
NIBPMeasurementModes .............................................................................................................36
DescriptionofNIBPOperation ......................................................................................................36
SpO2/PulseRateMonitoring.................................................................................................................43
General...............................................................................................................................................44
SetupConnections............................................................................................................................45
DescriptionofPulseRateOperation .............................................................................................46
DescriptionofSpO2Operation.......................................................................................................46
TemperatureMonitoring .......................................................................................................................49
General...............................................................................................................................................50
SetupConnections............................................................................................................................50
TemperatureMeasurementModes................................................................................................51
Contents YM1000
ii YM1000 Operator’s Manual
DescriptionofTemperatureOperation .........................................................................................51
AlarmsandLimits...................................................................................................................................57
General...............................................................................................................................................57
SettingAlarmLimits ........................................................................................................................58
AlarmSilence ....................................................................................................................................64
ReviewingPatientData .........................................................................................................................65
General...............................................................................................................................................65
DisplayingStoredPatientData ......................................................................................................65
PrintingStoredPatientData(OptionalPrinterInstalled) ..........................................................67
ErasingPatientData.........................................................................................................................67
Printing .....................................................................................................................................................69
General...............................................................................................................................................69
SelectingManualorStreamPrintingtype....................................................................................69
PrintingPatientData(ManualMode) ...........................................................................................70
PrintOutConfiguration ..................................................................................................................71
RS232Interface.......................................................................................................................................73
Overview ...........................................................................................................................................73
CableConnection .............................................................................................................................73
NurseCallInterface .........................................................................................................................74
QuickGuidetoOperation ....................................................................................................................75
Maintenance.............................................................................................................................................81
General...............................................................................................................................................81
ReturningYM1000andSystemComponents ..............................................................................81
Service ................................................................................................................................................81
PeriodicSafetyChecks.....................................................................................................................82
Cleaning.............................................................................................................................................82
Batterymaintenance ........................................................................................................................82
ReplacementofPrinterPaper .........................................................................................................83
Troubleshooting ......................................................................................................................................85
General...............................................................................................................................................85
CorrectiveAction..............................................................................................................................86
EMI(ElectromagneticInterference)...............................................................................................87
ObtainingTechnicalAssistance......................................................................................................88
FactoryDefaults ......................................................................................................................................89
General...............................................................................................................................................89
ParameterRangesandDefaultSettings ........................................................................................89
Specifications...........................................................................................................................................91
Physical..............................................................................................................................................91
Electrical.............................................................................................................................................91
Environmental ..................................................................................................................................91
MeasurementParameters................................................................................................................92
Compliance........................................................................................................................................94
ManufacturersDeclaration ............................................................................................................96
Figures
Figure1.FrontPanelControlsandSymbols.................................................................................................................................... 7
Figure2.RearPanelComponentsandSymbols............................................................................................................................... 8
Figure3.ACPowerConnection..................................................................................................................................................... 17
Figure4.NIBPCableConnections................................................................................................................................................. 18
Figure5.SpO2Sensor/CableConnections...................................................................................................................................... 18
Figure6.TemperatureProbeConnections...................................................................................................................................... 19
Figure7.YM1000PowerOnSelfTest........................................................................................................................................... 24
YM1000 Contents
YM1000 Operators Manual iii
Figure8.YM1000NormalModeBeforeMeasurement ................................................................................................................. 25
Figure9.DateandTimeSetting .................................................................................................................................................... 26
Figure10.PatientTypeSetting...................................................................................................................................................... 27
Figure11.NIBPUnitsSetting....................................................................................................................................................... 28
Figure12.TemperatureUnitsandModesSetting .........................................................................................................................29
Figure13.PulseToneVolumeSetting............................................................................................................................................ 30
Figure14.AlarmVolumeSetting................................................................................................................................................... 31
Figure15.FactoryDefaultsSetting ............................................................................................................................................... 32
Figure16.NIBPSetupConnections .............................................................................................................................................. 35
Figure17.InitialInflationPressure ............................................................................................................................................... 37
Figure18.ManualmodeofNIBPoperation................................................................................................................................... 38
Figure19.IndicationofAutoModeTurnOff................................................................................................................................ 38
Figure20.AutoModeSetting(i.e.)15minutePeriod ................................................................................................................ 39
Figure21.AutoModeofMeasurement.......................................................................................................................................... 39
Figure22.STATModeSetting....................................................................................................................................................... 40
Figure23.SpO2SetupConnections ............................................................................................................................................... 45
Figure24.PulseRateOperation .................................................................................................................................................... 46
Figure25.SpO2Operation............................................................................................................................................................. 46
Figure26.TemperatureSetupConnections.................................................................................................................................... 50
Figure27.TemperaturePredictiveMode..................................................................................................................................... 52
Figure28.TemperatureMonitoredMode.................................................................................................................................... 55
Figure29.Exampledisplayofover43°Corunder26°C................................................................................................................ 55
Figure30.SystolicHighAlarmLimitSetting ............................................................................................................................... 59
Figure31.SystolicLowAlarmLimitSetting................................................................................................................................. 59
Figure32.DiastolicHighAlarmLimitSetting ............................................................................................................................. 60
Figure33.DiastolicLowAlarmLimitSetting............................................................................................................................... 60
Figure34.MAPHighAlarmLimitSetting................................................................................................................................... 61
Figure35.MAPLowAlarmLimitSetting .................................................................................................................................... 61
Figure36.PulseRateHighAlarmLimitSetting........................................................................................................................... 62
Figure37.PulseRateLowAlarmLimitSetting ............................................................................................................................ 62
Figure38.SpO2HighAlarmLimitSetting ................................................................................................................................... 63
Figure39.SpO2LowAlarmLimitSetting..................................................................................................................................... 63
Figure40.StoredPatientDataDisplay ......................................................................................................................................... 66
Figure41.PrintingTypeSetting.................................................................................................................................................... 69
Figure42.RealTimePrinting........................................................................................................................................................ 71
Figure43.StoredDataPrinting(BatchPrinting) ......................................................................................................................... 71
Figure44.StreamPrintingatAlarmCondition ............................................................................................................................ 72
Figure45.SystemInformationPrinting ........................................................................................................................................ 72
Figure46.RS232I/Oconnector.................................................................................................................................................... 73
Figure47.DataPortPinLayout.................................................................................................................................................... 73
Tables
Table1.DisplaySymbols/Indicators................................................................................................................................................. 9
Table2.YM1000Controls.............................................................................................................................................................. 13
Table3.FrontPanelIndicationsinaccordancewithpoweroperation............................................................................................ 21
Table4.Operatingtimeinaccordancewithbatteryconditions...................................................................................................... 22
Table5.CuffSize ............................................................................................................................................................................ 35
Table6.SpO2Sensors ..................................................................................................................................................................... 45
Table7.IndicationofTemperatureMeasurementMode................................................................................................................. 51
Table8.AlarmIndication ............................................................................................................................................................... 57
Table9.RangeofAlarmLimits(Defaults)..................................................................................................................................... 58
Table10.RS232SerialInterfaceConnections............................................................................................................................... 73
Table11.ErrorCodes...................................................................................................................................................................... 85
Table12.ParameterRangesandFactoryDefaults ......................................................................................................................... 89
Table13.ElectromagneticEmissions(IEC6060112) ................................................................................................................... 96
Table14.ElectromagneticImmunity(IEC6060112) ................................................................................................................... 96
Table15.ElectromagneticImmunity(IEC6060112) ................................................................................................................... 97
Table16.RecommendedSeparationDistances ............................................................................................................................... 98
Table17.Cables(IEC6060112) .................................................................................................................................................... 98
Contents YM1000
iv YM1000 Operators Manual
Thispageisintentionallyleftblank.
Safety Information
YM1000 Operators Manual 1
GeneralSafetyInformation
ThissectioncontainsimportantsafetyinformationrelatedtogeneraluseofYM1000vital
signsmonitor.Otherimportantsafetyinformationappearsthroughoutthemanualin
sectionsthatrelatespecificallytotheprecautionaryinformation.Readallprecautionary
information.YM1000vitalsignsmonitorwillbereferredtoasYM1000throughoutthis
manual.
Important!Beforeuse,carefullyreadthismanual,accessorydirectionsforuse,all
precautionaryinformation,andspecifications.
Warnings
WarningsareidentifiedbytheWARNINGsymbolshownabove.
Warningsalertyoutopotentialseriousoutcomes(death,injury,oradverseevents)tothe
patientoruser.
WARNING:Toavoidburns,theprobemustremainintheprobewellwhenturning
YM1000monitoronoroff.

WARNING:IntheUSA,donotconnecttoanelectricaloutletcontrolledbyawall
switchbecausethedevicemaybeaccidentallyturnedoff.

WARNING:Impendingpowerloss,themonitorwillautomaticallyoperateby
internalbattery.IfindoubtabouttheintegrityoftheACpowersource,themonitor
mustbeoperatedfromitsinternalbattery.

WARNING:Donotdisconnectapowercordbeforethesystempowercompletely
shutsdownbecausemonitorsettingsmaybelostatthismoment.

WARNING:Aswithanymedicalequipment,carefullyroutepatientcablingto
reducethepossibilityofpatiententanglementorstrangulation.

WARNING:YM1000isnotdefibrillatorproof.Itmayremainattachedtothepatient
duringdefibrillationorwhileanelectrosurgicalunitisinuse,butthereadingsmay
beinaccurateduringuseandshortlythereafter.

WARNING:Ifthemonitoroccurstobeabnormalshutdown,themonitor’ssettings
arebacktothefactorydefaults.

WARNING:Youmustchecktheequipmentpriortouseandensureitssafeand
properuse.

WARNING:Explosionhazard.DonotuseYM1000monitorinthepresenceof
flammableanestheticsorgases.DonotoperateYM1000inahyperbaricchamber,in
oxygenenrichedenvironments,orinanyotherpotentiallyexplosiveenvironment.
Safety Information YM1000
2 YM1000 Operator’s Manual
WARNING:Donotautoclavethemonitor.

WARNING:Beforeuse,carefullyreadsensororprobedirectionsforuse,including
allwarnings,cautions,andinstructions.

WARNING:Donotusedamagedcuffs,sensorsandothercables.Donotimmerse
cuffs,sensorsandothercablescompletelyinwater,solvents,orcleaningsolutions
becausetheconnectorsarenotwaterproof.Donotsterilizecuffs,sensorsandother
cablesbyirradiation,steam,orethyleneoxide.Refertoeachcleaninginstructionsin
thedirectionsforuse.

WARNING:Ifthebatteryshowsanysignsofdamage,leakage,orcracking,itmustbe
replacedimmediately,byaqualifiedserviceperson,andonlywithabattery
approvedbythemanufacturer.

WARNING:Themonitorisintendedonlyasanadjunctinpatientassessment.Itmust
beusedinconjunctionwithclinicalsignsandsymptoms.

WARNING:ThemeasurementofYM1000vitalsignsmonitorcanbeaffectedby
patientconditions,motions,sensors,environmentalconditionandelectromagnetic
externalcondition.

WARNING:Itispossiblethatanyradiofrequencytransmittingequipmentandother
sourcesofelectricalnoisesuchascellularphones,duetocloseproximityorstrength
ofasource,mayresultindisruptionofperformance.

WARNING:Toensurepatientsafety,donotplacethemonitorinanypositionthat
mightcauseittofallonthepatient.

WARNING:DisconnectYM1000andsensorsduringmagneticresonanceimaging
(MRI)scanning.UseduringMRIcouldcauseburnsoradverselyaffecttheMRI
imageorthemonitor’saccuracy.Also,toavoidburns,removethesensorsfromthe
patientbeforeconductingMRI.

WARNING:DuringprolongedandcontinuousSpO2monitoring,checkthesensor
siteatleastonceevery4hours.Inspectthepatient’sskinintegrityandcirculation,
andrelocatethesensorifnecessary.Tissuedamagecanresultfromimproperor
prolongedsensorattachment.

WARNING:Donotliftthemonitorbyasensorcableorapowercordbecausethe
cablecoulddisconnectfromthemonitor,causingthemonitortodroponthepatient.

WARNING:YM1000maynotoperateeffectivelyonpatientswhoareexperiencing
convulsionsortremors.
YM1000 Safety Information
YM1000 Operators Manual 3
Cautions
CAUTION:U.S.Federallawrestrictsthisdevicetosalebyorontheorderofalicensed
healthcarepractitioner.
CAUTION:AlertyoutoexercisecarenecessaryforthesafeandeffectiveuseofYM1000
monitor.Inaccuratedatamaybemeasuredifoperatedorstoredatconditionsoutsidethe
statedranges,orsubjectedtoexcessiveshockordropping.
CAUTION:Groundingreliabilitycanonlybeachievedwhenequipmentisconnectedtoan
equivalentreceptaclemarkedʹHospitalOnlyʹorʹHospitalGradeʹ.
CAUTION:Theaccuracyofthemonitormaydegradeifthemonitorisconnectedto
secondaryI/Odeviceswhenthemonitorisnotconnectedtoearthreference.
CAUTION:Neverplacefluidsonthemonitor.Incaseoffluidspillingonthemonitor,
disconnectpowercord,wipecleanimmediatelyandhavethemonitorservicedtoensure
thatnohazardexists.
CAUTION:Themonitormayclearlyappropriateerrorcodeswhenoutsideofthe
measurablerangeoccur.
Safety Information YM1000
4 YM1000 Operator’s Manual
Thispageisintentionallyleftblank.
Introduction
Features
Intended Use
About This Manual
YM1000 Operators Manual 5
WARNING:YM1000isintendedonlyasanadjunctinpatientassessment.Itmustbe
usedinconjunctionwithclinicalsignsandsymptoms.
ThismanualcontainsinformationaboutYM1000vitalsignsmonitor.YM1000monitorincludesthe
followingconfiguration:
Config.FeaturesConfig. Features
NStandard(NIBP+PulseRate)NPStandard+Printer
NSStandard+SpO2NSPStandard+SpO2+Printer
NTStandard+TemperatureNTPStandard+Temperature+Printer
NSTStandard+SpO2+TemperatureNSTPStandard+SpO2+Temperature+Printer
Note:YoucanselectLeadAcidbatteriesoroptionalNiMHbatteriesineachconfiguration.For
moreinformationaboutthebatteriesrefertotheSpecificationsection.
Allinformationinthismanual,includingtheillustrations,isbasedonamonitorconfiguredwith
theTemperature,SpO2,andPrinteroptions.Ifyourmonitorconfigurationlacksanyofthese
options,thensomeinformationinthismanualdoesnotapply.

FeaturesforYM1000
Physical
YM1000vitalsignsmonitorisalightweightandcompactvitalsignsmonitormeasuring
130×180×284(mm)(H×D×W)andweighing2.7kg.Itscarryinghandleisdesignedfor
instrumenttransportwhilebatterypoweredmonitoring.
Electrical
YM1000ispoweredbyLeadacidorNiMH(option)typeofinternalbatterypack.The
batteriesarecontinuouslyrechargedwhenACpower(100240VAC,5060Hz)isconnected
tothemonitor.DetailsaredescribedintheBatteryOperationsection.
Display
YM1000hasanFNDdisplaythatshowsnumericpatientinformationaswellasalphanumeric
statusconditionsanderrorcodes.
Auxiliary
Outputs
YM1000monitorprovidesRS232I/Oportforsoftwareupgradeornursecallsystem.Referto
theRS232Interfacesectionforadditionalinformation.
Introduction YM1000
6 YM1000 Operator’s Manual
IntendedUseforYM1000
ThepurposeandfunctionoftheMedianaYM1000vitalsignsmonitoristomonitornon
invasivebloodpressure(systolic,diastolic,andmeanarterialpressures),functionalarterial
oxygensaturation,pulserateforadult,pediatricandneonatepatientsandtemperaturefor
adultandpediatricpatientsinallhospitalareasandhospitaltypefacilities.Itmaybeused
duringhospitaltransportandinmobile,landbasedenvironments,suchasambulances,
withinthespecificationoftheenvironmentalcharacteristics.
Note:Hospitalusetypicallycoverssuchareasasgeneralcarefloors,operatingrooms,
specialprocedureareas,intensiveandcriticalcareareas,withinthehospitalplus
hospitaltypefacilities.Hospitaltypefacilitiesincludephysicianofficebasedfacilities,
sleeplabs,skillednursingfacilities,surgicenters,andsubacutecenters.
Note:Intrahospitaltransportincludestransportofapatientwithinthehospitalorhospital
typefacility.
AboutThisManual
ThismanualexplainshowtosetupanduseYM1000vitalsignsmonitor.Importantsafety
informationrelatingtogeneraluseofYM1000appearsbeforethisintroduction.Other
importantsafetyinformationislocatedthroughoutthetextwhereapplicable.
Allusersshouldreadthismanualthoroughly.MoreexperiencedusersofYM1000willbe
abletogotothetopicsfortheinformationtheyrequire.
ReadtheentiremanualincludingtheSafetyInformationsection,beforeyouoperatethe
monitor.
Description of Controls, Indicators, Symbols and Displays
Identification of Front Panel Controls and Symbols
Identification of Rear Panel Controls and Symbols
Description of YM1000 Symbols/ Indicators
Description of YM1000 Controls
YM1000 Operators Manual 7
IdentificationofFrontPanelControlsandSymbols


1.BloodPressureUnitIndicators15.%SpO2Display
2.SystolicBloodPressureDisplay16.ModeButton
3.PatientTypeIndicators17.PulseAmplitudeIndicator
4.DiastolicBloodPressureDisplay18.AlarmSilenceIndicator
5.PulseRateDisplay19.Up/DownSelectionButton
6.MAP(MeanArterialPressure)Display20.Alarmsilencebutton
7.PrintSettingIndicators21.NIBPstart/stopbutton
8.PrintButton22.TemperatureUnit/ModeIndicators
9.AlarmButton23.TemperatureDisplay
10.AutoIndicator24.PowerButton
11.AutoCycleDisplay25.BatteryIndicator
12.AutoButton26.Charging/ACinIndicator
13.PulseTone/AlarmVolumeSettingIndicators 27.TimeDisplay
14.ReviewButton28.ReviewIndicator
Figure1.FrontPanelControlsandSymbols
Description of Controls, Indicators, Symbols and Displays YM1000
8 YM1000 Operators Manual
IdentificationofRearPanelComponentsandSymbols

1.Handle4.Equipotential(Ground)
2.AirVentilator5.BatteryCover(Replacement)
3.ACPowerConnector6.RS232DataInterface
Figure2.RearPanelComponentsandSymbols
YM1000 Description of Controls, Indicators, Symbols and Displays
YM1000 Operators Manual 9
DescriptionofYM1000Symbols/Indicators
ThesymbolsandIndicatorsofYM1000aredescribedasfollows:
Table1.DisplaySymbols/Indicators
SymbolsDescription
Attention,consultaccompanyingdocuments.
TypeBFappliedpart
TypeBFDefibrillatorproof
Equipotentiality
Datainterface
ReviewIndicator
islitwhentheuserselecttheReviewbuttontoseethepatient
history.
AutoIndicator
isonwheneverNIBPautomatictimedcyclesareenabled.
Description of Controls, Indicators, Symbols and Displays YM1000
10 YM1000 Operators Manual
SymbolsDescription
Charging/ACinIndicator
isonwheneverACpowerispresentfromthewall(evenifthe
monitorisoffandisnotunderbatterycharging).
TheCharging/ACinindicatorflasheswhilethebatteryis
charging,andthenremainsilluminatedoncethebatteryis
maintainedwithatricklecharge.
BatteryIndicator
indicatesthestateofthebattery.Thisindicatorisonwhenthe
monitorusesbatterypower.Thisindicatorwillbeflashingwhen
thebatteryneedscharging.ItisnotresetunlessACpowercord
hasbeenpluggedinforbatterycharging.
AlarmSilenceIndicator
isoncontinuouslywhenevertheunitisinAlarmSilencemode.
TemperatureindegreesFahrenheit
isconfiguredtodisplaytemperatureindegreesFahrenheit.
TemperatureindegreesCelsius
isconfiguredtodisplaytemperatureindegreesCelsius.
TemperatureinMonitormode
isconfiguredtotaketemperatureinthemonitormode.This
indicatorisoffwhenthetemperatureisbeingtakenusingthe
predictivemethod.
Patienttype:Adult
shallbeonwhenthePatienttypeisadult.
Patienttype:Pediatric
isonwhenthePatienttypeispediatric.
YM1000 Description of Controls, Indicators, Symbols and Displays
YM1000 Operators Manual 11
SymbolsDescription
Patienttype:Neonatal
isonwhenthePatienttypeisneonatal.
NIBPunit:mmHg
isonwhentheNIBPunitsettingismmHg.
NIBPunit:kPa
isonwhentheNIBPunitsettingiskPa.
TargetPressureSettingIndicator
isflashingwhentheNIBPtargetinflationpressureisunder
settingforNIBPmeasurement.
TimeIndicator
isonwhentheactualtimeisdisplayedonthetime/datenumeric
displayarea.Itisflashingwhenitisselectedtosetthetimein
theconfigurationmode.
DateIndicator
isonwhentheactualdateisdisplayedonthetime/datenumeric
displayarea.Itisflashingwhenitisselectedtosetthedateinthe
configurationmode.
ManualPrintIndicator
isonwhentheprintsettingistheManualPrint.
StreamPrintIndicator
isonwhentheprintsettingistheStreamPrint.
Description of Controls, Indicators, Symbols and Displays YM1000
12 YM1000 Operators Manual
SymbolsDescription
PulseToneVo l u me Settingindicator
isflashingwhenthepulsetonevolumesettingisselectedinthe
settingmode.
AlarmVol u m e SettingIndicator
isflashingwhenthealarmvolumesettingisselectedinthe
settingmode.
NetworkIndicator
isflashingwhenthemonitorissettosoftwareupgrademode.
YM1000 Description of Controls, Indicators, Symbols and Displays
YM1000 Operators Manual 13
DescriptionofYM1000Controls
Table2.YM1000Controls
ControlsDescription
PowerButton
turnsYM1000monitoronoroffwhenpressed
forover1second.
NIBPstart/stopbutton
initiatesNIBPmeasurementwhenpressed.IftheNIBPstart/stop
buttonispressedagainduringthemeasurement,itwillcancel
thecurrentreading.
AlarmSilenceButton
allowsyoutosilenceapatientalarmtemporarilyandalsois
usedtoacknowledge(cancel)othernonpatientalarms.
Up/DownSelectionButtons
allowsyoutoselectitemswithinaparticularsettablefeaturein
severaldifferentmodes.IftheUporDownselectionbuttonis
pressedandheld,theunitwillscrollthroughtheavailable
selectionsasifthebuttonisbeingpressedrepeatedlywhilethe
buttonisheldin.
PrintButton(Option)
sendsthedatatotheprinterandprintscurrentonscreen
readingsifaprinterisinstalledinthemonitor.PressingthePrint
buttonduringprintoutstopsprinting.
ReviewButton
allowstheusertoreviewortoerasemeasurementdatainthe
memory.Ifpressedandheldformorethan3seconds,the
monitorwillerasethedata.
AutoButton
putsthemonitorinAutointervalselectionmode,allowingthe
usertotakeautomaticbloodpressuresataselectedincrement.
Description of Controls, Indicators, Symbols and Displays YM1000
14 YM1000 Operators Manual
ControlsDescription
AlarmButton
putsthemonitorintoAlarmSetmode,allowingtheusertoset
alarmlimitsforSystolic,Diastolic,MAP,PulserateandSpO2.
ModeButton
putsthemonitorintotheSettingsorConfigurationmode.Once
themonitorisinoneofthesemodes,theModebuttonwillbe
usedtocyclethroughtheconfigurationoptionsofthespecific
menumode.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Mediana YM1000 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI