COM
NC
NO
+
-
+
-
1 1
2 2
3 3
44
55
66
77
88
O
FF
ON
1 1
2 2
3 3
44
55
66
77
88
O
F
F
O
N
E
SB
4W
2W
SB
4W
2W
Chain Black Red Rail
YellowYellow
Open Limit
Moter
Red
Black
Blue
Blue
Close Limit
++
++
ANT
GND
Short Press: Enter Transmier Setup Menu (See )
Long Press (5 sec): Forced Relearn (See )
Installaon- and User Manual
S-Series Garage Door Opener
Control Panel
In Standby: Decrease or Increase Force Offset Values ( )
Press and together: Enter Funcon Setup Menu ( )
In Funcon Setup Menu: Scroll Funcons and Values ( )
In Transmier Setup Menu: Scroll Funcons ( )
G
D
D
C
In Standby: Acts as Run Buon (Open and Close Door)
In Setup Menus: Confirm Chosen Funcon or Value
In any Setup Menu: Exit Menu.In any Setup Menu: Exit Menu.
1
3
4
2
1
2
3
4
11
2
3
Panasonic
C
R2016
3V
+
Panasonic
CR2016
3V
+
Panasonic
CR2016
3V
+
Panasonic
CR2016
3V
+
B
Run Funcon
Venlaon / Holiday
Light / Transmier Coding
Run / Auto Close Override
Alternately Opens, Closes or Stops the Garage Door.
Short Press - Switches Courtesy Light ON and OFF.
Long Press (5 sec) - Refer to for details. Enter Transmier Setup Menu.
C
Short Press - Iniates a Drive into Venlaon Mode
Posion. (Only available if Venlaon Funcon is
enabled.)
Long Press (3 sec) - Iniates Holiday Mode. Places Opener
into a dormant state aer reaching Close posion. Refer to
for details. (Only available if Venlaon Funcon
is disabled.)
If Auto-Close disabled - Funcons same as Buon .
If Auto-Close enabled - Funcons same as Buon , however Door will not
Auto-Close when opened from this buon. Press for 3 sec to acvate.
1
1
How to Change Baeries
Transmier Funcons Ex Factory
D
C
33
1
2
Every Button of a Transmitter can be programmed with a
different Function as Listed below
1.1 Bulk Coding from Control Panel (see Pic 1.1)
1.2 Bulk Coding from coded Transmier (see Pic 1.2)
1) Bulk Coding same as Factory Seng. ( )
2) Assign certain Funcons to certain Transmier Buon.
There are two ways to learn a new transmier:
1 Bulk Coding same as Factory Seng. ( ))
2 Assign certain Funcons to certain Transmier Buon.)
B
Long Press 5 sec
press once
Pic 1.1 Pic 1.2
1. On already coded Transmier Long press Light)
Funcon (Buon 3 on pre - coded Transmier) for 5
sec. Display shows , Courtesy LED Light begins to
flash.
2. Press new Transmier twice unl LED fast flashes. )
Learning Complete.
Bulk Coding - (TX learns Funcons as shown in )
Run Funcon - Open/Stop/Close ( see )
Venlaon / Holiday Mode Funcon ( see )
1. Short press on Opener,)
2. Long press 5 sec unl light starts flashing, Finished.)
B
B
B
1
3
Light Funcon ( see ) -
Run Funcon/Auto Close Override - ( see )
OPEN Funcon - Only OPENS Door
CLOSE Funcon - only CLOSES Door
1. Short press on Opener, )
2. Use and to choose the desired funcon (see List above ). )
Transmier Coding
Delete all TransmiersDelete all Transmiers
press twice
press twice
BB
1.) On Display Press Buon . Display shows ,
Courtesy LED Light begins to flash.
2. Press new Transmier twice unl LED fast flashes. )
Learning Complete.
B
B
2
4
Learn
Learn
Learn
Learn
Confirm
D
Values
Funcon
Descripon
Safety Photo Beam
Automac Close
Funcon
Safety Beams must
be enabled!
8.2 kOhm Safety
Contact Strip
Disable Safety Beam
Enable Safety Beam in
CLOSE Direcon
Enable Safety Beam in CLOSE and OPEN
Direcon.
No Auto-Close
Running Speed of
Opener
Slow Stop Funcon
Full Power Mode
Courtesy Light
Illuminaon me
Paral reverse /
Full reverse
Signal Reverse /
Signal Stop
Venlaon
Mode Time
Venlaon
Re-Opening Height
Door Service Monitor
Car Park Mode
Maximum Run Time
Back Jump
OFF
Opener Stops aer
30 sec Run Time
Aer reaching Close Posion, Motor drives back 3mm
to release pressure from door
Opener Stops aer
60 sec Run Time
Accessories wired to COM/NO Connector (Key-Switch, Card Readers, etc.) will only
trigger OPEN Funcon. Hand Transmiers are NOT effected by this funcon.
If Door is out of Balance, Light will
flash during run to warn user
OFF
OFF
OFF
If door is idling in
VenlaonPosion,
shows in Display.
At press TX in Close
Direcon,Door will: Stop
Aer Hing Obstrucon,
Door will: Fully Reverse
Aer Hing Obstrucon,
Door will: Paral Reverse
At press TX in Close Direcon,
Door will: Reverse
1 min
2 min
3 min
Aer setup, will start.
Follow Steps .
30 sec / 180 sec30 sec / 180 sec
15 sec /
90 sec
05 sec /
30 sec
Low Speed
Tip Up Door
Speed
No Slow
Stop
High Speed
Disable
Safety Strip
Enable Safety Strip
Funcon Setup
Aer setup, will start.
Follow Steps .
Aer setup, will start.
Follow Steps .
Outside Menu Funcons
Factory Reset: Switch off opener first. Iniate Reset by pressing and power on unl Display shows . Previouslycoded TX will not be deleted.
Holiday Mode: Press Holiday Funcon (Buon 2 on Bulk-Coded TX) for 3 seconds. Places Opener in a dormant state AFTER closing. is displayed.
Safety Beam Funcon
not enabled
If Safety Beam is acvated by passing car or person:
Door automacally closes aer 5/15/30 sec.
5
5
5
With acvated Venlaon Mode: Short Press Venlaon
Mode Buon on Transmier (2nd Buon on Bulk Coded
Transmier), Door will close completely, and then re-
open between 2-18 cm for Venlaon Purposes. Aer set
15/30/45/60/75/90 min door will automacally close.
OFF
Funcon not available in this version
Height of
Venlaon Slit
-
If Courtesy Light is switched on by Hand Transmier Light
Funcon, it will not automacally switch off.
Forced Relearn: Drive Door into ANY Posion but CLOSE. Long Press for 5 sec unl Display shows . See for further instrucons.
1.) To Enter Funcon Setup Menu: press at the same me. 3.) Now choose value with and . Confirm
chosen value by pressing .
4.) To Exit Funcon Setup Menu at any me: press .
2.) Use and to scroll up and down through the funcons.
Press to select the desired funcon.
5
If Safety Beam is NOT acvated by passing car or person:
Door automacally closes aer 30/90/180 sec.
Short Slow
Stop
Long Slow
Stop
Blinking Output
3s Delay
Output same as
Courtesy Light
OFF
Steady Output
3s Delay
External Flash Light
Output
Learn
Learn
Safety Photo Beam
Open/Stop/CIose
OnIy"OPEN" Funcon
Transformer
Baery Backup
Door in Door
Coax Antenna
Connecon PIan
If accessories connected
to COM/NO are required
to ONLY trigger the
OPEN direction, Mode
needs to be set to .
This does NOT effect any
Hand Transmitter
Functions.
Run Buon: Open and Close Door. Connuos Press
overrides Safety Beam in Close Direcon.
Warning Light 24V AC
Max. 2A
8.2 kOhm Safety
Contact Strip
++
--
230V AC
NN
LL
Relay
24V AC
Warning Light 230V AC
++
++
LAM P
SB
4W
2W
24V NOCOMSBRS
NC
CO M
C
D
M10
1
1
Assemble Rail, Mount Control Unit and Running Unit, Tension Chain
Mount Brackets and Rail
M12
6
3b
3a
5a
5b
< 50mm
3
4
clickclickclick
clickclickclick
5
OK
G
3 sec
4
Running Unit
2
Control Unit
2
Install Track NOT HIGHER
than 50mm above highest
arcing point of Door Panel!
CLOSE the Door by hand, then slide the Stopper as shown in drawing
into the carriage unl “click” is heard. Then firmly ghten the lock screw.
Connect to Power Supply. Courtesy Light begins to flash. is shown in Display.
Long Press Transmier Buon 1 for 3 seconds unl Light Fast Flashes.
1.) Door will AUTOMATICALLY RUN TWO (2) Complete Cycles ...
... (Close, Open, Close, Open) and then Stop in Open Posion.
Learning Complete when Blinking and exnguishes.
Pull Release Lever and make sure Running Unit is engaged.
OPEN the Door by hand, then slide the Stopper as shown in drawing
into the carriage unl “click” is heard. Then firmly ghten the lock screw.
Fine Tune Safety Offset Value
Safety Offset Value determines how easily the door Safety Reverses/Safety
Stops when hing an obstrucon. In order to prevent “ghosng” on a big,
badly sprung or worn, out door, Safety Value needs to be set to a higher value
(max.= ). In order to achieve a more sensive Safety Reversing, Safety
Offset Value needs to be set to a lower value (min.= ). Safety Offset Values
can be fine tuned at any me.
Fine Tune Safety Offset Value
1.) At any me, Press or . The
current Safety Offset Value is
shown.
2.) Press to increase or to
decrease the Value, being the
most sensive being the least
sensive value.
F
Trouble Shoong
In case of an unusual incident, the Courtesy LED light triple
flashes, and an Error Code is displayed as below:
1.) Safety Photo Beam
obstructed by
Obstacle.
2.) Safety Photo Beam
malfunconing or not
installed correctly.
3.) Safety Photo Beam
not installed, but
Safety Photo Beam
Funcon enabled.
1.) Remove Obstacle.
2.) Replace
Malfunconing Device
or check Installaon.
3.) Install Safety Photo
Beam or disable Safety
Photo Beam Funcon.
1.) Safety Contact Strip
obstructed by Obstacle.
2.) Safety Contact Strip
malfunconing or not
installed correctly.
3.) Safety Contact Strip
not installed, but Safety
Contact Strip Funcon
enabled.
1.) Remove Obstacle.
2.) Replace
Malfunconing Device or
check Installaon.
3.) Install Safety Contact
Strip or disable Safety
Contact Strip Funcon.
1.) Adjust door balance.
2.) Turn off funcon
(be aware of the
Risks involved).
Maximum Run Time
Exceeded.
1.) Check and clear
reason that causes the
opener
exceeding Run Time.
2.) Engage emergency
release.
3.) Adjust run me from
30 sec to 60 sec. by
funcon see .
1. Set Safety Offset )
Values higher ( ).
2. Adjust Door Balance )
and Door Installaon.
3. Choose a more )
powerful Opener Model.
1. Door hit an Obstacle )
during Open or Close
movement.
2. Door in improper shape.)
1. Remove Obstacle. )
same as ( ).
Same as .
Door imbalanced
when Funcon enabled.
G
D
1
During Learn or Re-Learn
of Force Values : Door
Hit an Obstrucon or
Exceeded Set Safety
Offset Values.
Engage Running Unit, Connet to Power Supply
Posion Close/Open Stopper
Learning Travel & Force
Confirm
Learn
3.) To confirm new Safety Offset
Value press .
4.) To leave without changes wait 10
seconds or press .
  • Page 1 1
  • Page 2 2

Avanti S-series Installation and User Manual

Type
Installation and User Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI