Aprilaire ARNALM is a battery-operated radon system alarm that utilizes piezoresistive pressure sensor (PPS) technology to provide audible and visual indication when the radon system's vacuum pressure drops below the preset operating limit. It features selectable alarm and service delay functions (48 hours, 7 days, 30 days), hush and test buttons, and mounts on 2", 3", 4", or 6" pipes or flat surfaces.

Aprilaire ARNALM is a battery-operated radon system alarm that utilizes piezoresistive pressure sensor (PPS) technology to provide audible and visual indication when the radon system's vacuum pressure drops below the preset operating limit. It features selectable alarm and service delay functions (48 hours, 7 days, 30 days), hush and test buttons, and mounts on 2", 3", 4", or 6" pipes or flat surfaces.

FEATURES
• Battery Operated (No Wiring Required)
• Vacuum Sensing
• Visual and Audible Indicators
• Selectable Alarm & Service Delay Functions
(48 Hours / 7 Days / 30 Days)
• Hush and Test Buttons
• Mounts on 2”, 3”, 4” or 6” Pipe, or Flat Surfaces
INSTALLATION INSTRUCTIONS
This alarm is for conditioned* indoor installations
only and should be located in an area where it will
be readily observed by the occupants. Outdoor
installation will void the warranty!
*Conditioned living space that is temperature and
humidity controlled.
TOOLS NEEDED
DIRECT PIPE MOUNTING -
HORIZONTAL & VERTICAL PIPE
1. Choose a location on the suction side of the
radon fan (a minimum of 12 inches from fan)
in an area readily observable by building
occupants.
2. Drill a hole using a 9/16” drill bit. Clean hole of
drill debris and make sure the pipe surrounding
the hole is clean and free of dirt, oils and grease.
3. Without removing the protective lm on the
pipe mount adapter, test the t by placing the
adapter into the hole in the pipe and adjust hole
if necessary.
4. Connect one end of the silicone pipe connector
elbow to the alarm housing port located inside
the battery compartment by pushing it onto the
port barb.
5. Slide the pipe mounting bracket into the back of
the alarm housing, making note of the curvature
and how it relates to the orientation of the pipe
at the place of installation. Connect the open
end of the silicone pipe connector elbow to the
pipe mounting bracket port by pushing it onto
the port barb.
6. Peel back the protective lm on the mounting
tape and insert the assembled alarm/bracket
assembly into the drilled hole, making sure it is
level, and rmly press in place to seat mounting
tap (See ACTIVATION section for alarm activation
instructions). When attaching the pipe adapter
for the alarm, rst make sure the pipe is clean, dry
and free of any debris.
NOTE: ADAPTER MUST BE PRESSED FIRMLY AGAINST
PIPE FOR 30 SECONDS TO ENSURE THAT THE 3M TAPE
BONDS TO THE PIPE AND BRACKET SURFACES.
Alternative Pipe Adapter Mounting: Once the
selected adapter is installed (Note: make sure
that the connector elbow is NOT installed), slide
off alarm body from adapter and attach the
adapter plate using two of the four adapter plate
holes and two screws provided with the ARNALM
(a 1/16” drill bit can be used to drill pilot holes in
the pipe). NOTE: regardless of adapter orientation
(horizontal or vertical in relation to the alarm), use
the two screw holes located at 9 and 3 o’clock so
that the screws do not interfere with sliding the
ARNALM onto the adapter.
REMOTE - WALL MOUNTING
1. Mount the ARNALM Alarm within 50’ of where
the radon system piping will be monitored. Wall
surface must be clean and free of dirt, oils and
grease.
2. Using a liquid level and pencil, mark a line on
the wall surface where the edge of the ARNALM
housing will be located.
3. Mount the pipe adapter (at a minimum
distance of 12 inches from the fan) on the
suction side of the radon fan. Drill a hole using a
9/16” drill bit. Clean hole of drill debris and make
sure the pipe surrounding the hole is clean and
free of dirt, oils and grease.
4. Without removing the protective lm on the
pipe mount adapter, test the t by placing the
adapter into the hole in the pipe and adjust hole
if necessary.
5. Peel back the protective lm on the mounting
tape and insert the pipe mounting bracket onto
the radon system pipe.
6. Connect one end of the tubing (50’ max; sold
separately) to the pipe mount adapter by
pushing the tubing onto the port barb. Route the
tubing to the location where the ARNALM alarm
will be mounted, avoiding pinching or kinking the
tubing along the way.
7. Insert the tubing into the hole located at the
bottom of the alarm housing until it reaches into
the battery compartment.
8. Connect the tubing to the alarm housing by
pushing the tubing onto the port barb. Slide
the wall mounting bracket into the back of the
alarm housing.
9. Peel back the protective lm on the mounting
tape and rmly press the assembled alarm/
bracket assembly onto the wall to seat
mounting tape, making sure it is aligned with the
pencil mark previously placed on the wall.
NOTE: ARNALM uses a permanent tape that may
cause damage if removed. If you must remove
the mounted device, use a piece of dental oss or
wire held tautly between two hands. Pull back and
forth to split the tape, and release the mounted
object. (See ACTIVATION section for alarm
activation instructions)
Model ARNALM
Radon System Alarm
Test Button
Hush Alarm / Delay
Duration Select Button
Sensing Light
Low Battery Light
Service Light
Alarm Light
Battery Cover
[Depth 1.37”]
[HEIGHT 3.75”]
[WIDTH 2.19”]
SystemSystem
AlarAlarmm
with PPS Technology
Radon
PATENT-PENDINGPATENT-PENDING
ABOUT THE ALARM
The Radon System Alarm is a vacuum monitoring
product utilizing piezoresistive pressure sensor
(PPS) technology. This product provides audible
and visual indication when the Radon System’s
vacuum pressure has dropped below the preset
operating limit, resulting in insufcient pressure to
be effective.
BOX CONTENTS
• ARNALM Radon System Alarm
• Wall Mount Adapter (at)
• Pipe Mount Adapter (curved)
• Silicone Alarm/Pipe Connector Elbow
• Battery
• Product Instructions
• Two Adapter Mounting Screws
4 51 2 3
9/16” Drill Bit
FUNCTIONAL MODES
Sensing Mode (Visual Only) - Sensing light blinks
@ 60-second intervals (3 ashes).
Pre-Alarm Mode (Visual Only) - Alarm light blinks
@ 60-second intervals when low or no pressure
is sensed. Pre-alarm ends when the pressure is
restored within the selected delay duration or it
enters Alarm Mode.
Alarm Mode - After selected delay duration, buzzer
beeps and Red alarm light ashes, then no light
or beep for 60 seconds, then repeat until “Hush” is
pressed or system is serviced.
Service Mode - After 3 pre-alarm conditions occur
within the selected delay duration, buzzer beeps
and blue Service light ashes, then no light or
beeps for 60 seconds, then repeat until “Hush” is
pressed or system is serviced.
Hush Mode - Silences audible sound for 7 days but
visual remains as programmed; after 7 days goes
back to sensing mode, alarm mode (with sound)
or service mode (with sound).
Low Battery Mode - 1 “chirp” and simultaneous
ash @ 5-minute intervals.
Test Mode - Audible “beep” sounds and all lights
illuminate when “Test” button pressed.
Step 1: Press and hold “Hush” button for a
minimum of 5 seconds to start the time delay
selection mode.
Step 2: Keep “Hush” button held down until the
desired time delay appears (every 5 seconds) as
shown below:
Step 3: Stop depressing “Hush” button when
desired time delay appears as indicated by the
LEDs. Time delay selection mode will cycle in a
continual loop until the “Hush” button is no longer
depressed. Once the “Hush” button is no longer
depressed the time delay mode will no longer be
activated.
ACTIVATION
Prior to alarm activation, make sure both ends of
the silicone pipe connector are connected and
the radon fan is running. Remove the battery
isolator installed for shipping from the positive
pole end of the battery. The battery may have
been shipped separate from the alarm box and
in that case, the battery must be installed to
activate. Ensure battery is properly seated. Alarm
is now powered on and will begin the activation
sequence automatically.
Battery
Isolator
CALIBRATION
The ARNALM self-calibrates automatically upon
installation of the battery. After the alarm is
powered on, the system will run a 20-second
initialization to measure baseline system
operating pressure. The green sensing LED will
ash during this time. A single beep of the buzzer
will indicate the initialization is complete and the
alarm is now active. No additional calibration is
necessary.
AUDIBLE ALARM DELAY SELECTION
The ARNALM comes equipped with three optional
audible & service alarm delays. To select the
desired alarm delay duration complete the
following steps:
P/N: B2209690A 61002032 • 4.22
© 2022 AprilAire | aprilairepartners.com | 800.334.6011
1015 East Washington Ave, Madison, WI 53703
LED States Descriptions Delay durations Note
Both the “SENSING”
and the “ALARM”
LED’s are lighted up.
48 hours Default
Only the “SENSING”
LED is lighted up. 7 days
Selected by holding
down Hush button for
5 Seconds
Only the “ALARM” LED
is lighted up. 30 days
Selected by holding
“Hush” button down
for 10 seconds
FUNCTIONAL SPECIFICATIONS
Sensing Range: -0.1”WC to -20”WC
Alarm Range: ≥90% reduction of
baseline pressure
Service Condition: 3+ Pre-Alarm Trig.
@ 48 Hrs
After 48 Hours, 7 Days
or 30 Days
Low Battery Condition: <3.35 V
Hush Button: Silences alarm sound
for 7 days
Test Button: Sounds alarm /
activates lights
Dimensions: W x H x D (2.19” x
3.75” x 1.37”)
Overpressure: ±20”WC
Audible Alarm: ≈85 dba
INDICATOR LIGHT EXPLANATION
Sensing, Green Light (Flashing)
= Operating / Sensing
Alarm, Red Light (Flashing)
= Low / No Pressure (Vacuum)
Service, Blue Light (Flashing)
= Service Mode
Battery, Yellow Light (Flashing)
= Low Battery
BATTERY REPLACEMENT
1. Remove existing battery.
2. Be sure fan is operating and alarm tubing is
still connected.
3. Install new battery and make sure it is
properly seated.
4. 20-Second self-calibration operation will
then begin (refer to CALIBRATION section for
additional information).
WARRANTY INFORMATION
Subject to applicable consumer protection
legislation, AprilAire warrants that the Alarm
(model ARNALM) will be free from defective
material and workmanship for a period of (2)
years from the date of purchase. Warranty is
contingent on installation in accordance with the
instructions provided. This warranty does not apply
where repairs or alterations have been made or
attempted by others; or the unit has
been abused or misused. Warranty does not
include damage in shipment unless the damage
is due to the negligence of AprilAire. All other
warranties, expressed or written, are not valid.
To make a claim under these limited warranties,
you must return the defective item to AprilAire
with a copy of the purchase receipt. AprilAire is
not responsible for installation or removal cost
associated with this warranty.
In no case is AprilAire liable beyond the repair or
replacement of the defective product FOB AprilAire.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND
THE DESCRIPTION ON THE FACE HEREOF. THERE IS
NO WARRANTY OF MERCHANTIBILITY. ALL OTHER
WARRANTIES, EXPRESSED OR WRITTEN, ARE NOT
VALID.
For service under these warranties, contact
AprilAire for a Return Material Authorization (RMA)
number and shipping information. No returns can
be accepted without an RMA. If factory return is
required, the customer assumes all shipping costs
to and from factory.
9 10 116 7 8
  • Page 1 1
  • Page 2 2

Aprilaire ARNALM User manual

Type
User manual

Aprilaire ARNALM is a battery-operated radon system alarm that utilizes piezoresistive pressure sensor (PPS) technology to provide audible and visual indication when the radon system's vacuum pressure drops below the preset operating limit. It features selectable alarm and service delay functions (48 hours, 7 days, 30 days), hush and test buttons, and mounts on 2", 3", 4", or 6" pipes or flat surfaces.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI