37113-1-1019Page 2 Empire Comfort Systems Inc. • Belleville, IL
PARTS LIST
PART DESCRIPTION CONVERSION KIT - 35395 CONVERSION KIT - 35397 QUANTITY SUPPLIED
PilotOrice R7659 R10425 1
MainBurnerOrice P244 P244 1
NG Flue Restrictor
34054 34054 1
SITGasValveConversionKit
R7656 R11168 1
GasConversionLabel 2139 2139 1
Tools Needed:StandardScrewdriver,1/4"HexDriver,5/16"HexDriver,3/8"and1/2"Wrenches
Gas input for direct vent replace insert converted to Natural Gas:
• DVCP36(PP,SP)3034,000Btuperhour
• DVCP36(PP,SP)7034,000Btuperhour
ThedirectventgasreplacewhenconvertedtoNaturalGaswillhaveamanifoldpressureapproximately3.5"w.c.
(.871kPa)foramaximuminputor1.7"w.c.(.423kPa)foraminimuminputatthevalveoutletwiththeinletpressuretothe
valvefromaminimumof5.0"w.c.(1.244kPa)forthepurposeofinputadjustmenttoamaximumof10.5"w.c.(2.61kPa).
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceinsertisinstalled,turnOFFgasandelectricsupplytoreplacebeforemakinggasconversion.
2. Removeaccesspanelbelowglass;liftandpullawayfromreplace.
3. Releasethetwoglassframespringclampsbeneathoneofthetwoglassframes.
4. Removetheglassframeandscreenframeasanassembly.
5. Removelogsfromburnerassembly.
6. Removethetenscrewsaroundtheburnerperimeter,andremovethefalseoorfromtheburnerassembly.
7. Removethefourscrewsretainingtheburnertotheburnerbase,andremoveburner.
8. RemovePropaneGasmainburneroricefromoricetting.
9. InstallNaturalGasmainburneroriceintooricetting:
• forDVCP36(PP,SP)30,OriceisMARKED #33
• forDVCP36(PP,SP)70,OriceisMARKED #33
10. Pullupwardonpilothoodtoremoveandgainaccesstopilotinjectororice.
11. RemovePropaneGaspilotinjectororicefrompilotburnerwith5/32"hex(Allen)wrench.
12. InsertIncludedNaturalGaspilotinjectororiceintopilotburnerusinga5/32"hexwrench.
13. Re-installpilothoodtopilotassembly.Pushdownwardtosnapinplace.
14. ForDVCP36(PP,SP)30only,convertgasvalveasinstructedinS.I.T.NaturalGasValveConversionKit.
15.
ForDVCP36(PP,SP)70only,removePropaneGasvalvefrommanifoldpipeandreplacewithincludedNaturalGasvalve.
16. Adjustairshuttersettingto3/16”open(1/8”with40ft.verticalvent).
17. Replacetheburnerassemblyontotheburnerbase.
18. Replacethefalseoortotheburner.
19. Forverticallyventedinstallationsonly,replacetheuerestrictorwithincludedNaturalGasuerestrictor.
20. Replacelogset.
21. Replaceglassandscreenframes,andloweraccesspanel.
22.
Theconvertedreplacemustbeconnectedtoasupplyoftheconversiongasandcheckedforleaksatallconnections.